Refine
Year of publication
Document Type
- Preprint (361)
- Article (205)
- Conference Proceeding (2)
- Working Paper (2)
- Doctoral Thesis (1)
- Master's Thesis (1)
Has Fulltext
- yes (572)
Is part of the Bibliography
- no (572)
Keywords
Institute
- Physik (552)
- Frankfurt Institute for Advanced Studies (FIAS) (482)
- Informatik (464)
- Medizin (15)
- Informatik und Mathematik (4)
- Mathematik (3)
- Biowissenschaften (1)
- Center for Financial Studies (CFS) (1)
- House of Finance (HoF) (1)
- Senckenbergische Naturforschende Gesellschaft (1)
Neutron-induced reaction cross sections are important for a wide variety of research fields ranging from the study of nuclear level densities, nucleosynthesis to applications of nuclear technology like design, and criticality and safety assessment of existing and future nuclear reactors, radiation dosimetry, medical applications, nuclear waste transmutation, accelerator-driven systems and fuel cycle investigations. Simulations and calculations of nuclear technology applications largely rely on evaluated nuclear data libraries. The evaluations in these libraries are based both on experimental data and theoretical models. CERN’s neutron time-of-flight facility n_TOF has produced a considerable amount of experimental data since it has become fully operational with the start of its scientific measurement programme in 2001. While for a long period a single measurement station (EAR1) located at 185 m from the neutron production target was available, the construction of a second beam line at 20 m (EAR2) in 2014 has substantially increased the measurement capabilities of the facility. An outline of the experimental nuclear data activities at n_TOF will be presented.
The accurate knowledge of the neutron-induced fission cross-sections of actinides and other isotopes involved in the nuclear fuel cycle is essential for the design of advanced nuclear systems, such as Generation-IV nuclear reactors. Such experimental data can also provide the necessary feedback for the adjustment of nuclear model parameters used in the evaluation process, resulting in the further development of nuclear fission models. In the present work, the 240Pu(n,f) cross-section was measured at CERN's n_TOF facility relative to the well-known 235U(n,f) cross section, over a wide range of neutron energies, from meV to almost MeV, using the time-of-flight technique and a set-up based on Micromegas detectors. This measurement was the first experiment to be performed at n_TOF's new experimental area (EAR-2), which offers a significantly higher neutron flux compared to the already existing experimental area (EAR-1). Preliminary results as well as the experimental procedure, including a description of the facility and the data handling and analysis, are presented.
We have measured the radiative neutron-capture cross section and the total neutron-induced cross section of one of the most important isotopes for the s process, the 25Mg. The measurements have been carried out at the neutron time-of-flight facilities n_TOF at CERN (Switzerland) and GELINA installed at the EC-JRC-IRMM (Belgium). The cross sections as a function of neutron energy have been measured up to approximately 300 keV, covering the energy region of interest to the s process. The data analysis is ongoing and preliminary results show the potential relevance for the s process.
Aim: To compare clinical success and complications of uncovered self-expanding metal stents (SEMS) vs covered SEMS (cSEMS) in obstruction of the small bowel.
Methods: Technical success, complications and outcome of endoscopic SEMS or cSEMS placement in tumor related obstruction of the duodenum or jejunum were retrospectively assessed. The primary end points were rates of stent migration and overgrowth. Secondary end points were the effect of concomitant biliary drainage on migration rate and overall survival. The data was analyzed according to the Strengthening the Reporting of Observational Studies in Epidemiology guidelines.
Results: Thirty-two SEMS were implanted in 20 patients. In all patients, endoscopic stent implantation was successful. Stent migration was observed in 9 of 16 cSEMS (56%) in comparison to 0/16 SEMS (0%) implantations (P = 0.002). Stent overgrowth did not significantly differ between the two stent types (SEMS: 3/16, 19%; cSEMS: 2/16, 13%). One cSEMS dislodged and had to be recovered from the jejunum by way of laparotomy. Time until migration between SEMS and cSEMS in patients with and without concomitant biliary stents did not significantly differ (HR = 1.530, 95%CI 0.731-6.306; P = 0.556). The mean follow-up was 57 ± 71 d (range: 1-275 d).
Conclusion: SEMS and cSEMS placement is safe in small bowel tumor obstruction. However, cSEMS is accompanied with a high rate of migration in comparison to uncovered SEMS.
Above 1 MeV of incident neutron energy the fission fragment angular distribution (FFAD) has generally a strong anisotropic behavior due to the combination of the incident orbital momentum and the intrinsic spin of the fissioning nucleus. This effect has to be taken into account for the efficiency estimation of devices used for fission cross section measurements. In addition it bears information on the spin deposition mechanism and on the structure of transitional states. We designed and constructed a detection device, based on Parallel Plate Avalanche Counters (PPAC), for measuring the fission fragment angular distributions of several isotopes, in particular 232Th. The measurement has been performed at n_TOF at CERN taking advantage of the very broad energy spectrum of the neutron beam. Fission events were recognized by back to back detection in coincidence in two position-sensitive detectors surrounding the targets. The detection efficiency, depending mostly on the stopping of fission fragments in backings and electrodes, has been computed with a Geant4 simulation and validated by the comparison to the measured case of 235U below 3 keV where the emission is isotropic. In the case of 232Th, the result is in good agreement with previous data below 10 MeV, with a good reproduction of the structures associated to vibrational states and the opening of second chance fission. In the 14 MeV region our data are much more accurate than previous ones which are broadly scattered.
The thesis deals with the analysis and modeling of point processes emerging from different experiments in neuroscience. In particular, the description and detection of different types of variability changes in point processes is of interest.
A non-stationary rate or variance of life times is a well-known problem in the description of point processes like neuronal spike trains and can affect the results of further analyses requiring stationarity. Moreover, non-stationary parameters might also contain important information themselves. The goal of the first part of the thesis is the (further) development of a technique to detect both rate and variance changes that may occur in multiple time scales separately or simultaneously. A two-step procedure building on the multiple filter test (Messer et al., 2014) is used that first tests the null hypothesis of rate homogeneity allowing for an inhomogeneous variance and that estimates change points in the rate if the null hypothesis is rejected. In the second step, the null hypothesis of variance homogeneity is tested and variance change points are estimated. Rate change points are used as input. The main idea is the comparison of estimated variances in adjacent windows of different sizes sliding over the process. To determine the rejection threshold functionals of the Brownian motion are identified as limit processes under the null of variance homogeneity. The non-parametric procedure is not restricted to the case of at most one change point. It is shown in simulation studies that the corresponding test keeps the asymptotic significance level for a wide range of parameters and that the test power is remarkable. The practical applicability of the procedure is underlined by the analysis of neuronal spike trains.
Point processes resulting from experiments on bistable perception are analyzed in the second part of the thesis. Visual illusions allowing for than more possible perception lead to unpredictable changes of perception. In the thesis data from (Schmack et al., 2015) are used. A rotating sphere with switching perceived rotation direction was presented to the participants of the study. The stimulus was presented continuously and intermittently, i.e., with short periods of „blank display“ between the presentation periods. There are remarkable differences in the response patterns between the two types of presentation. During continuous presentation the distribution of dominance times, i.e., the intervals of constant perception, is a right-skewed and unimodal distribution with a mean of about five seconds. In contrast, during intermittent presentation one observes very long, stable dominance times of more than one minute interchanging with very short, unstable dominance times of less than five seconds, i.e., an increase of variability.
The main goal of the second part is to develop a model for the response patterns to bistable perception that builds a bridge between empirical data analysis and mechanistic modeling. Thus, the model should be able to describe both the response patterns to continuous presentation and to intermittent presentation. Moreover, the model should be fittable to typically short experimental data, and the model should allow for neuronal correlates. Current approaches often use detailed assumptions and large parameter sets, which complicate parameter estimation.
First, a Hidden Markov Model is applied. Second, to allow for neuronal correlates, a Hierarchical Brownian Model (HBM) is introduced, where perception is modeled by the competition of two neuronal populations. The activity difference between these two populations is described by a Brownian motion with drift fluctuating between two borders, where each first hitting time causes a perceptual change. To model the response patterns to intermittent presentation a second layer with competing neuronal populations (coding a stable and an unstable state) is assumed. Again, the data are described very well, and the hypothesis that the relative time in the stable state is identical in a group of patients with schizophrenia and a control group is rejected. To sum up, the HBM intends to link empirical data analysis and mechanistic modeling and provides interesting new hypotheses on potential neuronal mechanisms of cognitive phenomena.
Background: To investigate the occupational risk of tuberculosis (TB) infection in a low-incidence setting, data from a prospective study of patients with culture-confirmed TB conducted in Hamburg, Germany, from 1997 to 2002 were evaluated. Methods: M. tuberculosis isolates were genotyped by IS6110 RFLP analysis. Results of contact tracing and additional patient interviews were used for further epidemiological analyses. Results: Out of 848 cases included in the cluster analysis, 286 (33.7%) were classified into 76 clusters comprising 2 to 39 patients. In total, two patients in the non-cluster and eight patients in the cluster group were health-care workers. Logistic regression analysis confirmed work in the health-care sector as the strongest predictor for clustering (OR 17.9). However, only two of the eight transmission links among the eight clusters involving health-care workers had been detected previously. Overall, conventional contact tracing performed before genotyping had identified only 26 (25.2%) of the 103 contact persons with the disease among the clustered cases whose transmission links were epidemiologically verified. Conclusion: Recent transmission was found to be strongly associated with health-care work in a setting with low incidence of TB. Conventional contact tracing alone was shown to be insufficient to discover recent transmission chains. The data presented also indicate the need for establishing improved TB control strategies in health-care settings.
The neutron sensitivity of the C6D6 detector setup used at n_TOF facility for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n_TOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has been implemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with a natC sample, showing an excellent agreement above 1 keV. At lower energies, an additional component in the measured natC yield has been discovered, which prevents the use of natC data for neutron background estimates at neutron energies below a few hundred eV. The origin and time structure of the neutron background have been derived from the simulations. Examples of the neutron background for two different samples are demonstrating the important role of accurate simulations of the neutron background in capture cross-section measurements.
Aim: To evaluate the ability of PillCamColon2 to visualize colonic segments missed by incomplete optical colonoscopy (OC) and to assess the diagnostic yield.
Methods: This prospective multicentre study included 81 patients from nine centres who underwent second-generation colon capsule endoscopy (CCE) following incomplete OC performed by an experienced gastroenterologist (> 1000 colonoscopies). Patients with stenosis were excluded. According to patient preferences, CCE was performed the following day (protocol A) after staying on clear liquids and 0.75 L Moviprep in the morning or within 30 d after new split-dose Moviprep (protocol B). Boosts consisted of 0.75 L and 0.25 L Moviprep, and phospho-soda was given as a rescue if the capsule was not excreted after seven hours.
Results: Seventy-four patients were analysed (51% of them in group A; 49% in group B). Bowel cleansing was adequate in 67% of cases, and CCE could visualize colonic segments missed by incomplete colonoscopy in 90% of patients under protocol A and 97% of patients under protocol B (P = 0.35, n.s.). Significant polyps including adenocarcinoma were detected in 24% of cases. Detection rates for all polyps and significant polyps per patient were similar in both protocols. Polyps were found predominantly in the right colon (86%) in segments that were not reached by OC. Extracolonic findings - such as reflux esophagitis, suspected Barrett esophagus, upper GI-bleeding, gastric polyps, gastric erosions and angiectasia - were detected in eight patients. PillCamColon2 capsule was retained in the ileum of one patient (1.4%) without symptoms and removed during an uneventful resection for unknown Crohn’s disease that was diagnosed as the cause of anemia, which was the indication for colonoscopy. CCE was well tolerated. One patient suffered from self-limiting vomiting after consuming the phospho-soda.
Conclusion: Second-generation CCE using a low-volume preparation is useful after incomplete OC, and it allows for the detection of additional relevant findings, but cleansing efficiency could be improved.
Needlestick injuries: a density-equalizing mapping and socioeconomic analysis of the global research
(2020)
Background: Needlestick injuries have caused a deleterious effect on the physical and mental health of millions of health-care workers over the past decades, being responsible for occupational infections with viruses such as HIV or hepatis C. Despite this heavy burden of disease, no concise studies have been published on the global research landscape so far.
Methods: We used the New Quality and Quantity Indices in Science platform to analyze global NSI research (n = 2987 articles) over the past 115 years using the Web of Science and parameters such as global versus country-specific research activities, semi-qualitative issues, and socioeconomic figures.
Results: Density-equalizing mapping showed that although a total of n = 106 countries participated in NSI research, large parts of Africa and South America were almost invisible regarding global participation in NSI research. Average citation rate (cr) analysis indicated a high rate for Switzerland (cr = 25.1), Italy (cr = 23.5), and Japan (cr = 19.2). Socioeconomic analysis revealed that the UK had the highest quotient QGDP of 0.13 NSI-specific publications per bill. US-$ gross domestic product (GDP), followed by South Africa (QGDP = 0.12). Temporal analysis of HIV versus hepatitis research indicated that NSI-HIV research culminated in the early 1990s, whereas NSI-hepatitis research increased over the observed period from the 1980s until the last decade.
Conclusion: Albeit NSI research activity is generally increasing, the growth is asymmetrical from a global viewpoint. International strategies should be followed that put a focus on NSI in non-industrialized areas of the world.
The energy dependence of multiplicity fluctuations was studied for the most central Pb+Pb collisions at 20A, 30A, 40A, 80A and 158A GeV by the NA49 experiment at the CERN SPS. The multiplicity distribution for negatively and positively charged hadrons is significantly narrower than Poisson one for all energies. No significant structure in energy dependence of the scaled variance of multiplicity fluctuations is observed. The measured scaled variance is lower than the one predicted by the grand-canonical formulation of the hadron-resonance gas model. The results for scaled variance are in approximate agreement with the string-hadronic model UrQMD.
New neutron cross section measurements of minor actinides have been performed recently in order to reduce the uncertainties in the evaluated data, which is important for the design of advanced nuclear reactors and, in particular, for determining their performance in the transmutation of nuclear waste. We have measured the 241Am(n,γ) cross section at the n_TOF facility between 0.2 eV and 10 keV with a BaF2 Total Absorption Calorimeter, and the analysis of the measurement has been recently concluded. Our results are in reasonable agreement below 20 eV with the ones published by C. Lampoudis et al. in 2013, who reported a 22% larger capture cross section up to 110 eV compared to experimental and evaluated data published before. Our results also indicate that the 241Am(n,γ) cross section is underestimated in the present evaluated libraries between 20 eV and 2 keV by 25%, on average, and up to 35% for certain evaluations and energy ranges.
The design and operation of innovative nuclear systems requires a better knowledge of the capture and fission cross sections of the Pu isotopes. For the case of capture on 242Pu, a reduction of the uncertainty in the fast region down to 8-12% is required. Moreover, aiming at improving the evaluation of the fast energy range in terms of average parameters, the OECD NEA High Priority Request List (HPRL) requests high-resolution capture measurements with improved accuracy below 2 keV. The current uncertainties also affect the thermal point, where previous experiments deviate from each other by 20%. A fruitful collaboration betwen JGU Mainz and HZ Dresden-Rossendorf within the EC CHANDA project resulted in a 242Pu sample consisting of a stack of seven fission-like targets making a total of 95(4) mg of 242Pu electrodeposited on thin (11.5 μm) aluminum backings. This contribution presents the results of a set of measurements of the 242Pu(n, γ) cross section from thermal to 500 keV combining different neutron beams and techniques. The thermal point was determined at the Budapest Research Reactor by means of Neutron Activation Analysis and Prompt Gamma Analysis, and the resolved (1 eV - 4 keV) and unresolved (1 - 500 keV) resonance regions were measured using a set of four Total Energy detectors at the CERN n_TOF-EAR1.
The accuracy on neutron capture cross section of fissile isotopes must be improved for the design of future nuclear systems such as Gen-IV reactors and Accelerator Driven Systems. The High Priority Request List of the Nuclear Energy Agency, which lists the most important nuclear data requirements, includes also the neutron capture cross sections of fissile isotopes such as 233,235U and 239,241Pu. A specific experimental setup has been used at the CERN n_TOF facility for the measurement of the neutron capture cross section of 235U by a set of micromegas fission detectors placed inside a segmented BaF2 Total Absorption Calorimeter.
The experimental area 2 (EAR-2) at CERNs neutron time-of-flight facility (n_TOF), which is operational since 2014, is designed and built as a short-distance complement to the experimental area 1 (EAR-1). The Parallel Plate Avalanche Counter (PPAC) monitor experiment was performed to characterize the beam pro↓le and the shape of the neutron 'ux at EAR-2. The prompt γ-flash which is used for calibrating the time-of-flight at EAR-1 is not seen by PPAC at EAR-2, shedding light on the physical origin of this γ-flash.
Anorexia nervosa (AN) is a complex neuropsychiatric disorder presenting with dangerously low body weight, and a deep and persistent fear of gaining weight. To date, only one genome-wide significant locus associated with AN has been identified. We performed an exome-chip based genome-wide association studies (GWAS) in 2158 cases from nine populations of European origin and 15 485 ancestrally matched controls. Unlike previous studies, this GWAS also probed association in low-frequency and rare variants. Sixteen independent variants were taken forward for in silico and de novo replication (11 common and 5 rare). No findings reached genome-wide significance. Two notable common variants were identified: rs10791286, an intronic variant in OPCML (P=9.89 × 10−6), and rs7700147, an intergenic variant (P=2.93 × 10−5). No low-frequency variant associations were identified at genome-wide significance, although the study was well-powered to detect low-frequency variants with large effect sizes, suggesting that there may be no AN loci in this genomic search space with large effect sizes.
Electric charge correlations were studied for p+p, C+C, Si+Si, and centrality selected Pb+Pb collisions at sqrt[sNN]=17.2 GeV with the NA49 large acceptance detector at the CERN SPS. In particular, long-range pseudorapidity correlations of oppositely charged particles were measured using the balance function method. The width of the balance function decreases with increasing system size and centrality of the reactions. This decrease could be related to an increasing delay of hadronization in central Pb+Pb collisions.
Evidence for an exotic S=-2, Q=-2 baryon resonance in proton-proton collisions at the CERN SPS
(2004)
Results of resonance searches in the Xi - pi -, Xi - pi +, Xi -bar+ pi -, and Xi -bar+ pi + invariant mass spectra in proton-proton collisions at sqrt[s]=17.2 GeV are presented. Evidence is shown for the existence of a narrow Xi - pi - baryon resonance with mass of 1.862±0.002 GeV/c2 and width below the detector resolution of about 0.018 GeV/c2. The significance is estimated to be above 4.2 sigma . This state is a candidate for the hypothetical exotic Xi --3/2 baryon with S=-2, I=3 / 2, and a quark content of (dsdsu-bar). At the same mass, a peak is observed in the Xi - pi + spectrum which is a candidate for the Xi 03/2 member of this isospin quartet with a quark content of (dsusd-bar). The corresponding antibaryon spectra also show enhancements at the same invariant mass.