Refine
Year of publication
- 2020 (5) (remove)
Document Type
- Article (5)
Language
- English (5)
Has Fulltext
- yes (5)
Is part of the Bibliography
- no (5)
Keywords
- TAVI (2)
- aortic stenosis (2)
- Aortic stenosis (1)
- Functional mitral regurgitation (1)
- Inflammation (1)
- MAGGIC score (1)
- MitraClip (1)
- Monocytes (1)
- NIRS (1)
- Seattle heart failure model (1)
Institute
- Medizin (5)
Background: MitraClip ® (MC) is an established procedure for severe mitral regurgitation (MR) in patients deemed unsuitable for surgery. Right ventricular dysfunction (RVD) is associated with a higher mortality risk. The prognostic accuracy of heart failure risk scores like the Seattle heart failure model (SHFM) and Meta-Analysis Global Group in Chronic Heart Failure (MAGGIC) score in pts undergoing MC with or without RVD has not been investigated so far. Methods: SHFM and MAGGIC score were calculated retrospectively. RVD was determined as tricuspid annular plane systolic excursion (TAPSE) ≤15 mm. Area under receiver operating curves (AUROC) of SHFM and MAGGIC were performed for one-year all-cause mortality after MC. Results: N = 103 pts with MR III° (73 ± 11 years, LVEF 37 ± 17%) underwent MC with a reduction of at least I° MR. One-year mortality was 28.2%. In Kaplan-Meier analysis, one- year mortality was significantly higher in RVD-pts (34.8% vs 2.8%, p = 0.009). Area under the Receiver Operating Characteristic (AUROC) for SHFM and MAGGIC were comparable for both scores (SHFM: 0.704, MAGGIC: 0.692). In pts without RVD, SHFM displayed a higher AUROC and therefore better diagnostic accuracy (SHFM: 0.776; MAGGIC: 0.551, p < 0.05). In pts with RVD, MAGGIC and SHFM displayed comparable AUROCs. Conclusion: RVD is an important prognostic marker in pts undergoing MC. SHFM and MAGGIC displayed adequate over-all prognostic power in these pts. Accuracy differed in pts with and without RVD, indicating higher predictive power of the SHFM score in pts without RVD.
Aortic stenosis is the most common valvular disease worldwide. With transcatheter aortic valve replacement (TAVR) being increasingly expanded to lower-risk populations, several challenging issues remain to be solved. The present review aims at discussing modern approaches to such issues as well as the current status of TAVR. TAVR has undergone several developments in the recent years: an increased use of transfemoral access, the development of prostheses in order to adapt to challenging anatomies, improved delivery systems with repositioning features, and outer skirts aiming at reducing paravalvular leak. The indication of TAVR is increasingly being expanded to patients with lower surgical risk. The main clinical trials supporting such expansion are reviewed and the latest data on low-risk patients are discussed. A number of challenges need still to be addressed and are also reviewed in this paper: the need for updated international guidelines including the latest evidence; a reduction of main complications such as permanent pacemaker implantation, paravalvular leak, and stroke (and its potential prevention by using anti-embolic protection devices); the appropriate role of TAVR in patients with concomitant cardiac ischemic disease; and durability of bio-prosthetic implanted valves. Finally, the future perspectives for TAVR use and next device developments are discussed.
Background: Both EPO levels and anemia have shown prognostic value in several cardiac disorders. An observational study with a prospective follow-up was performed to investigate their independent prognostic roles in severe aortic stenosis. Methods: An up to 36-month follow-up of consecutive patients with severe aortic stenosis undergoing TAVR in a high-volume center was performed. Patients with eGRF <30 mL/min/1.73 m2 were excluded. EPO levels and/or anemia status and its association with mid-term mortality were assessed. Results: Out of 407, 360 met eligibility criteria. Median age was 83 years, with 71.4% having a NYHA class III/IV. Anemia was present in 51.9%, and iron deficiency in 52.8%. Median (IQR) EPO levels were 14.4 (9.30–24.30) mIU/mL. Median follow-up was 566 days. Anemia was associated with overall mortality (HR 2.40, 95% CI 1.51–3.80, p < 0.001). Higher logEPO levels were associated with mid-term mortality (HR 4.05, 95% CI 2.29–7.16, p < 0.001), even after adjusting for clinically and/or statistically relevant factors (multivariate HR 2.25, 95 CI 1.09–4.66, p = 0.029). Kaplan-Meier analyses showed early diverging curves for anemia vs. non-anemia, whereas curves for patients in various EPO level quartiles started to diverge at about 100 days, with differences consistently increasing during the subsequent entire follow-up period. Conclusions: Differently from anemia, which was a strong predictor for both early and late mortality in severe aortic stenosis after TAVR, independent prognostic value of EPO only emerged after post-TAVR recovery. EPO prognostic value was independent from anemia and mild-to-moderate renal dysfunction. High EPO levels could be useful to identify patients with severe aortic stenosis showing a compromised mid-term survival in spite of TAVR use and independently from early TAVR results.
Background: Cerebral O2 saturation (ScO2) reflects cerebral perfusion and can be measured noninvasively by near-infrared spectroscopy (NIRS). Objectives: In this pilot study, we describe the dynamics of ScO2 during TAVI in nonventilated patients and its impact on procedural outcome. Methods and Results: We measured ScO2 of both frontal lobes continuously by NIRS in 50 consecutive analgo-sedated patients undergoing transfemoral TAVI (female 58%, mean age 80.8 years). Compared to baseline ScO2 dropped significantly during RVP (59.3% vs. 53.9%, p < .01). Five minutes after RVP ScO2 values normalized (post RVP 62.6% vs. 53.9% during RVP, p < .01; pre 61.6% vs. post RVP 62.6%, p = .53). Patients with an intraprocedural pathological ScO2 decline of >20% (n = 13) had higher EuroSCORE II (3.42% vs. 5.7%, p = .020) and experienced more often delirium (24% vs. 62%, p = .015) and stroke (0% vs. 23%, p < .01) after TAVI. Multivariable logistic regression revealed higher age and large ScO2 drops as independent risk factors for delirium. Conclusions: During RVP ScO2 significantly declined compared to baseline. A ScO2 decline of >20% is associated with a higher incidence of delirium and stroke and a valid cut-off value to screen for these complications. NIRS measurement during TAVI procedure may be an easy to implement diagnostic tool to detect patients at high risks for cerebrovascular complications and delirium.
Aims: Systemic inflammatory response, identified by increased total leucocyte counts, was shown to be a strong predictor of mortality after transcatheter aortic valve implantation (TAVI). Yet the mechanisms of inflammation-associated poor outcome after TAVI are unclear. Therefore, the present study aimed at investigating individual inflammatory signatures and functional heterogeneity of circulating myeloid and T-lymphocyte subsets and their impact on 1 year survival in a single-centre cohort of patients with severe aortic stenosis undergoing TAVI. Methods and results: One hundred twenty-nine consecutive patients with severe symptomatic aortic stenosis admitted for transfemoral TAVI were included. Blood samples were obtained at baseline, immediately after, and 24 h and 3 days after TAVI, and these were analysed for inflammatory and cardiac biomarkers. Myeloid and T-lymphocyte subsets were measured using flow cytometry. The inflammatory parameters were first analysed as continuous variables; and in case of association with outcome and area under receiver operating characteristic (ROC) curve (AUC) ≥ 0.6, the values were dichotomized using optimal cut-off points. Several baseline inflammatory parameters, including high-sensitivity C-reactive protein (hsCRP; HR = 1.37, 95% CI: 1.15–1.63; P < 0.0001) and IL-6 (HR = 1.02, 95% CI: 1.01–1.03; P = 0.003), lower counts of Th2 (HR = 0.95, 95% CI: 0.91–0.99; P = 0.009), and increased percentages of Th17 cells (HR = 1.19, 95% CI: 1.02–1.38; P = 0.024) were associated with 12 month all-cause mortality. Among postprocedural parameters, only increased post-TAVI counts of non-classical monocytes immediately after TAVI were predictive of outcome (HR = 1.03, 95% CI: 1.01–1.05; P = 0.003). The occurrence of SIRS criteria within 48 h post-TAVI showed no significant association with 12 month mortality (HR = 0.57, 95% CI: 0.13–2.43, P = 0.45). In multivariate analysis of discrete or dichotomized clinical and inflammatory variables, the presence of diabetes mellitus (HR = 3.50; 95% CI: 1.42–8.62; P = 0.006), low left ventricular (LV) ejection fraction (HR = 3.16; 95% CI: 1.35–7.39; P = 0.008), increased baseline hsCRP (HR = 5.22; 95% CI: 2.09–13.01; P < 0.0001), and low baseline Th2 cell counts (HR = 8.83; 95% CI: 3.02–25.80) were significant predictors of death. The prognostic value of the linear prediction score calculated of these parameters was superior to the Society of Thoracic Surgeons score (AUC: 0.88; 95% CI: 0.78–0.99 vs. 0.75; 95% CI: 0.64–0.86, respectively; P = 0.036). Finally, when analysing LV remodelling outcomes, ROC curve analysis revealed that low numbers of Tregs (P = 0.017; AUC: 0.69) and increased Th17/Treg ratio (P = 0.012; AUC: 0.70) were predictive of adverse remodelling after TAVI. Conclusions: Our findings demonstrate an association of specific pre-existing inflammatory phenotypes with increased mortality and adverse LV remodelling after TAVI. Distinct monocyte and T-cell signatures might provide additive biomarkers to improve pre-procedural risk stratification in patients referred to TAVI for severe aortic stenosis.