Refine
Year of publication
- 2016 (3) (remove)
Language
- English (3)
Has Fulltext
- yes (3)
Is part of the Bibliography
- no (3)
Keywords
- Couch tracking (1)
- Gimbaled tracking (1)
- Hepatitis c (1)
- MLC tracking (1)
- Organ motion (1)
- Robotic tracking (1)
- liver transplantation (1)
Institute
- Medizin (3)
Bipolar disorder (BD) is a genetically complex mental illness characterized by severe oscillations of mood and behavior. Genome-wide association studies (GWAS) have identified several risk loci that together account for a small portion of the heritability. To identify additional risk loci, we performed a two-stage meta-analysis of >9 million genetic variants in 9,784 bipolar disorder patients and 30,471 controls, the largest GWAS of BD to date. In this study, to increase power we used ~2,000 lithium-treated cases with a long-term diagnosis of BD from the Consortium on Lithium Genetics, excess controls, and analytic methods optimized for markers on the Xchromosome. In addition to four known loci, results revealed genome-wide significant associations at two novel loci: an intergenic region on 9p21.3 (rs12553324, p = 5.87×10-9; odds ratio = 1.12) and markers within ERBB2 (rs2517959, p = 4.53×10-9; odds ratio = 1.13). No significant X-chromosome associations were detected and X-linked markers explained very little BD heritability. The results add to a growing list of common autosomal variants involved in BD and illustrate the power of comparing well-characterized cases to an excess of controls in GWAS.
Objective: Chronically HCV-infected orthotopic liver transplantation (OLT) recipients appear to have improved outcomes when their immunosuppressive regimen includes a mammalian target of rapamycin (mTOR) inhibitor. The mechanism underlying this observation is unknown.
Design: We used virological assays to investigate mTOR signalling on the HCV replication cycle. Furthermore, we analysed HCV RNA levels of 42 HCV-positive transplanted patients treated with an mTOR inhibitor as part of their immunosuppressive regimen.
Results: The mTOR inhibitor rapamycin was found to be a potent inhibitor for HCV RNA replication in Huh-7.5 cells as well as primary human hepatocytes. Half-maximal inhibition was observed at 0.01 µg/mL, a concentration that is in the range of serum levels seen in transplant recipients and does not affect cell proliferation. Early replication cycle steps such as cell entry and RNA translation were not affected. Knockdown of raptor, an essential component of mTORC1, but not rictor, an essential component of mTORC2, inhibited viral RNA replication. In addition, overexpression of raptor led to higher viral RNA replication, demonstrating that mTORC1, but not mTORC2, is required for HCV RNA replication. In 42 HCV-infected liver-transplanted or kidney-transplanted patients who were switched to an mTOR inhibitor, we could verify that mTOR inhibition decreased HCV RNA levels in vivo.
Conclusions: Our data identify mTORC1 as a novel HCV replication factor. These findings suggest an underlying mechanism for the observed benefits of mTOR inhibition in HCV-positive OLT recipients and potentiate further investigation of mTOR-containing regimens in HCV-positive recipients of solid organ transplants.
Purpose: A study of real-time adaptive radiotherapy systems was performed to test the hypothesis that, across delivery systems and institutions, the dosimetric accuracy is improved with adaptive treatments over non-adaptive radiotherapy in the presence of patient-measured tumor motion.
Methods and materials: Ten institutions with robotic(2), gimbaled(2), MLC(4) or couch tracking(2) used common materials including CT and structure sets, motion traces and planning protocols to create a lung and a prostate plan. For each motion trace, the plan was delivered twice to a moving dosimeter; with and without real-time adaptation. Each measurement was compared to a static measurement and the percentage of failed points for γ-tests recorded.
Results: For all lung traces all measurement sets show improved dose accuracy with a mean 2%/2 mm γ-fail rate of 1.6% with adaptation and 15.2% without adaptation (p < 0.001). For all prostate the mean 2%/2 mm γ-fail rate was 1.4% with adaptation and 17.3% without adaptation (p < 0.001). The difference between the four systems was small with an average 2%/2 mm γ-fail rate of <3% for all systems with adaptation for lung and prostate.
Conclusions: The investigated systems all accounted for realistic tumor motion accurately and performed to a similar high standard, with real-time adaptation significantly outperforming non-adaptive delivery methods.