Refine
Year of publication
Document Type
- Article (18)
Language
- English (18)
Has Fulltext
- yes (18)
Is part of the Bibliography
- no (18)
Keywords
- Magnetic resonance imaging (4)
- Bone density (2)
- Cancer (2)
- DSM (2)
- Hepatocellular carcinoma (2)
- Neoplasms (2)
- Osteoporosis (2)
- Spine (2)
- Ablation Techniques (1)
- Automated Tube Potential Selection (1)
Institute
- Medizin (18)
Background: To evaluate survival data and local tumor control after transarterial chemoembolization in two groups with different embolization protocols for the treatment of HCC patients.
Methods: Ninty-nine patients (mean age: 63.6 years), 78 male (78.8%) with HCC were repeatedly treated with chemoembolization in 4-week-intervals. Eighty-eight patients had BCLC-Stage-B and in 11 patients, chemoembolization was performed for bridging (BCLC-Stage-A). In total, 667 chemoembolization treatments were performed (mean 6.7 treatments/patient). The administered chemotherapeutic agent included mitomycin. For embolization, lipiodol only (n = 51;51.5%; mean age 63.8 years; 38 male), or lipiodol plus degradable starch microspheres (DSM) (n = 48; 48.5%; mean age 63.4 years; 40 male) were used. The local tumor response was assessed by MRI using Response Evaluation Criteria in Solid Tumors 1.1 (RECIST 1.1). Patient survival times were evaluated using Kaplan-Meier curves and log-rank tests.
Results: The local tumor control in the lipiodol-group was: PR (partial response) in 11 (21.6%), SD (stable disease) in 32 (62.7%) and PD (progressive disease) in 8 cases (15.7%). In the lipiodol-DSM-group, PR was seen in 14 (29.2%), SD in 22 (45.8%), and PD in 12 (25.0%) individuals (p = 0.211). The median survival of patients after chemoembolization with lipiodol was 25 months and in the lipiodol-DSM-group 28 months (p = 0.845).
Conclusion: Our data suggest a slight benefit of the use of lipiodol and DSM in comparison of using lipiodol only for chemoembolization of HCC in terms of local tumor control and survival data, this trend did not reach the level of significance.
Rationale and objectives: The objective of this study was to analyze the role of dynamic magnetic resonance imaging (MRI) in patients who suffered from groin pain and whose physical examination and ultrasound returned inconclusive/indefinite results, as well as in patients receiving an ongoing assessment for a previous herniotomy.
Material and methods: For this study, 25 patients 14 women and 11 men were selected with a mean age of 41.6 years, including clinical complaints, such as groin pain and or a previous herniotomies. These patients underwent dynamic MRI. Reports were created by a radiology resident and a radiology consultant. Clinical and ultrasound documentation were compared to with imaging results from the MRI.
Results: The results of the dynamic MRI were negative for 23 patients (92%) and positive for two patients (8%). One patient suffered from an indirect hernia and one from a femoral hernia. A repeated hernia was an excluding for the preoperated patients with pain and ongoing assessment.
Conclusions: Dynamic MRI shows substantially higher diagnostic performance in exclusion of inguinal hernia, when compared to a physical examination and ultrasound. The examination can also be used in assessments to analyze the operation’s results.
Highlights
• MRI and ultrasound provided significant correlations between findings suggestive of vasculitis and the final diagnosis.
• Careful selection of available imaging techniques is warranted considering the time course, location, and clinical history.
• Considering its moderate diagnostic power to distinguish tracer uptake, a holistic view of PET/CT findings is essential.
Abstract
Purpose: To assess the diagnostic value of different imaging modalities in distinguishing systemic vasculitis from other internal and immunological diseases.
Methods: This retrospective study included 134 patients with suspected vasculitis who underwent ultrasound, magnetic resonance imaging (MRI), or 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) between 01/2010 and 01/2019, finally consisting of 70 individuals with vasculitis. The main study parameter was the confirmation of the diagnosis using one of the three different imaging modalities, with the adjudicated clinical and histopathological diagnosis as the gold standard. A secondary parameter was the morphological appearance of the vessel affected by vasculitis.
Results: Patients with systemic vasculitis had myriad clinical manifestations with joint pain as the most common symptom. We found significant correlations between different imaging findings suggestive of vasculitis and the final adjudicated clinical diagnosis. In this context, on MRI, vessel wall thickening, edema, and diameter differed significantly between vasculitis and non-vasculitis groups (p < 0.05). Ultrasound revealed different findings that may serve as red flags in identifying patients with vasculitis, such as vascular occlusion or halo sign (p = 0.02 vs. non-vasculitis group). Interestingly, comparing maximal standardized uptake values from PET/CT examinations with vessel wall thickening or vessel diameter did not result in significant differences (p > 0.05).
Conclusions: We observed significant correlations between different imaging findings suggestive of vasculitis on ultrasound or MRI and the final adjudicated diagnosis. While ultrasound and MRI were considered suitable imaging methods for detecting and discriminating typical vascular changes, 18F-FDG PET/CT requires careful timing and patient selection given its moderate diagnostic accuracy.
BACKGROUND: Evaluation of latest generation automated attenuation-based tube potential selection (ATPS) impact on image quality and radiation dose in contrast-enhanced chest-abdomen-pelvis computed tomography examinations for gynaecologic cancer staging.
METHODS: This IRB approved single-centre, observer-blinded retrospective study with a waiver for informed consent included a total of 100 patients with contrast-enhanced chest-abdomen-pelvis CT for gynaecologic cancer staging. All patients were examined with activated ATPS for adaption of tube voltage to body habitus. 50 patients were scanned on a third-generation dual-source CT (DSCT), and another 50 patients on a second-generation DSCT. Predefined image quality setting remained stable between both groups at 120 kV and a current of 210 Reference mAs. Subjective image quality assessment was performed by two blinded readers independently. Attenuation and image noise were measured in several anatomic structures. Signal-to-noise ratio (SNR) was calculated. For the evaluation of radiation exposure, CT dose index (CTDIvol) values were compared.
RESULTS: Diagnostic image quality was obtained in all patients. The median CTDIvol (6.1 mGy, range 3.9-22 mGy) was 40 % lower when using the algorithm compared with the previous ATCM protocol (median 10.2 mGy · cm, range 5.8-22.8 mGy). A reduction in potential to 90 kV occurred in 19 cases, a reduction to 100 kV in 23 patients and a reduction to 110 kV in 3 patients of our experimental cohort. These patients received significantly lower radiation exposure compared to the former used protocol.
CONCLUSION: Latest generation automated ATPS on third-generation DSCT provides good diagnostic image quality in chest-abdomen-pelvis CT while average radiation dose is reduced by 40 % compared to former ATPS protocol on second-generation DSCT.
Background: Computed tomography (CT) low-dose (LD) imaging is used to lower radiation exposure, especially in vascular imaging; in current literature, this is mostly on latest generation high-end CT systems.
Purpose: To evaluate the effects of reduced tube current on objective and subjective image quality of a 15-year-old 16-slice CT system for pulmonary angiography (CTPA).
Material and Methods: CTPA scans from 60 prospectively randomized patients (28 men, 32 women) were examined in this study on a 15-year-old 16-slice CT scanner system. Standard CT (SD) settings were 100 kV and 150 mAs, LD settings were 100 kV and 50 mAs. Attenuation of the pulmonary trunk, various anatomic landmarks, and image noise were quantitatively measured; contrast-to-noise ratios (CNR) and signal-to-noise ratios (SNR) were calculated. Three independent blinded radiologists subjectively rated each image series using a 5-point grading scale.
Results: CT dose index (CTDI) in the LD series was 66.46% lower compared to the SD settings (2.49 ± 0.55 mGy versus 7.42 ± 1.17 mGy). Attenuation of the pulmonary trunk showed similar results for both series (SD 409.55 ± 91.04 HU; LD 380.43 HU ± 93.11 HU; P = 0.768). Subjective image analysis showed no significant differences between SD and LD settings regarding the suitability for detection of central and peripheral PE (central SD/LD, 4.88; intra-class correlation coefficients [ICC], 0.894/4.83; ICC, 0.745; peripheral SD/LD, 4.70; ICC, 0.943/4.57; ICC, 0.919; all P > 0.4).
Conclusion: The LD protocol, on a 15-year-old CT scanner system without current high-end hardware or post-processing tools, led to a dose reduction of approximately 67% with similar subjective image quality and delineation of central and peripheral pulmonary arteries.
Purpose: The purpose of the study is to retrospectively evaluate the development and technological progress in local oncological treatments of hepatocellular carcinoma (HCC) by means of ablation techniques like laser interstitial thermal therapy (LITT), microwave ablation (MWA) and transarterial chemoembolization (TACE) in a multimodal application.
Method: This retrospective single-center study uses data generated between 1993 and 2020 (1,045 patients). Therapy results are evaluated using survival rates of Kaplan-Meier estimator, Cox proportional hazard regression and log-rank test.
Results: Median survival times in group LITT (25 patients) are 1.6 years, and, 2.6 years for LITT + TACE (67 patients). For LITT only treatments 1-/3-/5-year survival rates scored 64%, 24% and 20%. Results for combined LITT + TACE treatments were 84%, 37% and 14%. Median survival time in group MWA (227 patients) is 4.5 years. Estimated median survival time for MWA + TACE (108 patients) leads to a median survival time of 2.7 years. In group MWA the 1-/3-/5-year survival rates are 85%, 54%, 45%. Group MWA + TACE shows values of 79%, 41% and 25%. A separate group of 618 patients has been analyzed with TACE as monotherapy. Median survival time of 1 year was estimated in this group. 1-/3-/5-year survival rates are 48%, 15% and 8%. - Cox regression analysis showed that the different treatment methods are statistically significant predictors for survival of patients.
Conclusions: Treatments with MWA resulted in best median survival rates, followed by MWA + TACE in combination. Survival rates of MWA only are significantly higher vs. LITT, vs. LITT + TACE and vs. TACE monotherapy.
Objective: To investigate the accuracy, efficiency and radiation dose of a novel laser navigation system (LNS) compared to those of free-handed punctures on computed tomography (CT).
Materials and methods: Sixty punctures were performed using a phantom body to compare accuracy, timely effort, and radiation dose of the conventional free-handed procedure to those of the LNS-guided method. An additional 20 LNS-guided interventions were performed on another phantom to confirm accuracy. Ten patients subsequently underwent LNS-guided punctures.
Results: The phantom 1-LNS group showed a target point accuracy of 4.0 ± 2.7 mm (freehand, 6.3 ± 3.6 mm; p = 0.008), entrance point accuracy of 0.8 ± 0.6 mm (freehand, 6.1 ± 4.7 mm), needle angulation accuracy of 1.3 ± 0.9° (freehand, 3.4 ± 3.1°; p < 0.001), intervention time of 7.03 ± 5.18 minutes (freehand, 8.38 ± 4.09 minutes; p = 0.006), and 4.2 ± 3.6 CT images (freehand, 7.9 ± 5.1; p < 0.001). These results show significant improvement in 60 punctures compared to freehand. The phantom 2-LNS group showed a target point accuracy of 3.6 ± 2.5 mm, entrance point accuracy of 1.4 ± 2.0 mm, needle angulation accuracy of 1.0 ± 1.2°, intervention time of 1.44 ± 0.22 minutes, and 3.4 ± 1.7 CT images. The LNS group achieved target point accuracy of 5.0 ± 1.2 mm, entrance point accuracy of 2.0 ± 1.5 mm, needle angulation accuracy of 1.5 ± 0.3°, intervention time of 12.08 ± 3.07 minutes, and used 5.7 ± 1.6 CT-images for the first experience with patients.
Conclusion: Laser navigation system improved accuracy, duration of intervention, and radiation dose of CT-guided interventions.
Rationale and objectives: To provide a detailed analysis of injury patterns of the spine following blunt trauma and establish the role of supplementary MRI by evaluating discrepancies in the detection rates of damaged structures in CT and MRI.
Method: 216 patients with blunt trauma to the spine who underwent CT followed by supplementary MRI were included in this study. Two board-certified radiologists blinded to clinical symptoms and injury mechanisms independently interpreted all acquired CT and MRI images. The interpretation was performed using a dedicated catalogue of typical findings associated with spinal trauma and assessed for spinal stability using the AO classification systems.
Results: Lesions to structures associated with spinal instability were present in 31.0% in the cervical spine, 12.3% in the thoracic spine, and 29.9% in the lumbar spine. In all spinal segments, MRI provided additional information regarding potentially unstable injuries. Novel information derived from supplementary MRI changed clinical management in 3.6% of patients with injury to the cervical spine. No change in clinical management resulted from novel information on the thoracolumbar spine. Patients with injuries to the vertebral body, intervertebral disc, or spinous process were significantly more likely to benefit from supplementary MRI.
Conclusion: In patients that sustained blunt spinal trauma, supplementary MRI of the cervical spine should routinely be performed to detect injuries that require surgical treatment, whereas CT is the superior imaging modality for the detection of unstable injuries in the thoracolumbar spine.
The objective of this pilot clinical study was to assess the safety, technical feasibility, pharmacokinetic (PK) profile and tumour response of DC Bead™ with irinotecan (DEBIRI™) delivered by intra-arterial embolisation for the treatment of metastatic colorectal cancer. Eleven patients with unresectable liver metastases from CRC, tumour burden <30% of liver volume, adequate haematological, liver and renal function, performance status of <2 were included in this study. Patients received up to 4 sessions of TACE with DEBIRI at 3-week intervals. Feasibility of the procedure, safety and tumour response were assessed after each cycle. PK was measured after the first cycle. Patients were followed up to 24 weeks. Only mild to moderate adverse events were observed. DEBIRI is a technically feasibile procedure; no technical complications were observed. Average Cmax for irinotecan and SN-38 was 194 ng/ml and 16.7 ng/ml, respectively, with average t½ of 4.6 h and 12.4 h following administration of DEBIRI. Best overall response during the study showed disease control in 9 patients (2 patients with partial response and 7 with stable disease, overall response rate of 18%). Our study shows that transarterial chemoembolisation with irinotecan-loaded DC beads (DEBIRI) is safe, technically feasible and effective with a good PK profile.
Background: This prospective randomized trial is designed to compare the performance of conventional transarterial chemoembolization (cTACE) using Lipiodol-only with additional use of degradable starch microspheres (DSM) for hepatocellular carcinoma (HCC) in BCLC-stage-B based on metric tumor response. Methods: Sixty-one patients (44 men; 17 women; range 44–85) with HCC were evaluated in this IRB-approved HIPPA compliant study. The treatment protocol included three TACE-sessions in 4-week intervals, in all cases with Mitomycin C as a chemotherapeutic agent. Multiparametric magnetic resonance imaging (MRI) was performed prior to the first and 4 weeks after the last TACE. Two treatment groups were determined using a randomization sheet: In 30 patients, TACE was performed using Lipiodol only (group 1). In 31 cases Lipiodol was combined with DSMs (group 2). Response according to tumor volume, diameter, mRECIST criteria, and the development of necrotic areas were analyzed and compared using the Mann–Whitney-U, Kruskal–Wallis-H-test, and Spearman-Rho. Survival data were analyzed using the Kaplan–Meier estimator. Results: A mean overall tumor volume reduction of 21.45% (± 62.34%) was observed with an average tumor volume reduction of 19.95% in group 1 vs. 22.95% in group 2 (p = 0.653). Mean diameter reduction was measured with 6.26% (± 34.75%), for group 1 with 11.86% vs. 4.06% in group 2 (p = 0.678). Regarding mRECIST criteria, group 1 versus group 2 showed complete response in 0 versus 3 cases, partial response in 2 versus 7 cases, stable disease in 21 versus 17 cases, and progressive disease in 3 versus 1 cases (p = 0.010). Estimated overall survival was in mean 33.4 months (95% CI 25.5–41.4) for cTACE with Lipiosol plus DSM, and 32.5 months (95% CI 26.6–38.4), for cTACE with Lipiodol-only (p = 0.844), respectively. Conclusions: The additional application of DSM during cTACE showed a significant benefit in tumor response according to mRECIST compared to cTACE with Lipiodol-only. No benefit in survival time was observed.