Highlights
• MRI and ultrasound provided significant correlations between findings suggestive of vasculitis and the final diagnosis.
• Careful selection of available imaging techniques is warranted considering the time course, location, and clinical history.
• Considering its moderate diagnostic power to distinguish tracer uptake, a holistic view of PET/CT findings is essential.
Abstract
Purpose: To assess the diagnostic value of different imaging modalities in distinguishing systemic vasculitis from other internal and immunological diseases.
Methods: This retrospective study included 134 patients with suspected vasculitis who underwent ultrasound, magnetic resonance imaging (MRI), or 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) between 01/2010 and 01/2019, finally consisting of 70 individuals with vasculitis. The main study parameter was the confirmation of the diagnosis using one of the three different imaging modalities, with the adjudicated clinical and histopathological diagnosis as the gold standard. A secondary parameter was the morphological appearance of the vessel affected by vasculitis.
Results: Patients with systemic vasculitis had myriad clinical manifestations with joint pain as the most common symptom. We found significant correlations between different imaging findings suggestive of vasculitis and the final adjudicated clinical diagnosis. In this context, on MRI, vessel wall thickening, edema, and diameter differed significantly between vasculitis and non-vasculitis groups (p < 0.05). Ultrasound revealed different findings that may serve as red flags in identifying patients with vasculitis, such as vascular occlusion or halo sign (p = 0.02 vs. non-vasculitis group). Interestingly, comparing maximal standardized uptake values from PET/CT examinations with vessel wall thickening or vessel diameter did not result in significant differences (p > 0.05).
Conclusions: We observed significant correlations between different imaging findings suggestive of vasculitis on ultrasound or MRI and the final adjudicated diagnosis. While ultrasound and MRI were considered suitable imaging methods for detecting and discriminating typical vascular changes, 18F-FDG PET/CT requires careful timing and patient selection given its moderate diagnostic accuracy.
Abnormal venous atrial (VA) connections present a congenital heart disease (CHD) challenge for pediatric cardiologists. Fully anatomical evaluation is very difficult in prenatal and perinatal follow-up, but it has a profound impact on surgical correction and outcome. The echocardiogram is first-line imaging and represents the gold standard tool for simple abnormal VA connection. CT and MRI are mandatory for more complex heart disease and “nightmare cases”. 3D post-processing of volumetric CT and MRI acquisition helps to clarify anatomical relationships and allows for the creation of 3D printing models that can become crucial in customizing surgical strategy.
This prospective study sought to evaluate potential savings of radiation dose to medical staff using real-time dosimetry coupled with visual radiation dose feedback during angiographic interventions. For this purpose, we analyzed a total of 214 angiographic examinations that consisted of chemoembolizations and several other types of therapeutic interventions. The Unfors RaySafe i2 dosimeter was worn by the interventionalist at chest height over the lead protection. A total of 110 interventions were performed with real-time radiation dosimetry allowing the interventionalist to react upon higher x-ray exposure and 104 examinations served as the comparative group without real-time radiation monitoring. By using the real-time display during interventions, the overall mean operator radiation dose decreased from 3.67 (IQR, 0.95–23.01) to 2.36 μSv (IQR, 0.52–12.66) (−36%; p = 0.032) at simultaneously reduced operator exposure time by 4.5 min (p = 0.071). Dividing interventions into chemoembolizations and other types of therapeutic interventions, radiation dose decreased from 1.31 (IQR, 0.46-3.62) to 0.95 μSv (IQR, 0.53-3.11) and from 24.39 (IQR, 12.14-63.0) to 10.37 μSv (IQR, 0.85-36.84), respectively, using live-screen dosimetry (p ≤ 0.005). Radiation dose reductions were also observed for the participating assistants, indicating that they could also benefit from real-time visual feedback dosimetry during interventions (−30%; p = 0.039). Integration of real-time dosimetry into clinical processes might be useful in reducing occupational radiation exposure time during angiographic interventions. The real-time visual feedback raised the awareness of interventionalists and their assistants to the potential danger of prolonged radiation exposure leading to the adoption of radiation-sparing practices. Therefore, it might create a safer environment for the medical staff by keeping the applied radiation exposure as low as possible.