Refine
Year of publication
Document Type
- Article (36)
- Conference Proceeding (3)
- Part of a Book (1)
- Doctoral Thesis (1)
- Preprint (1)
- Working Paper (1)
Has Fulltext
- yes (43)
Is part of the Bibliography
- no (43) (remove)
Keywords
- Access (1)
- Autorensysteme (1)
- COVID-19 (1)
- Europe (1)
- Intensive care (1)
- Medienproduktion (1)
- TGF-beta (1)
- Technologie Enhanced Learning (1)
- Web-based Training (1)
- cholestasis (1)
Institute
Purpose: The coronavirus disease 2019 (COVID-19) poses major challenges to health-care systems worldwide. This pandemic demonstrates the importance of timely access to intensive care and, therefore, this study aims to explore the accessibility of intensive care beds in 14 European countries and its impact on the COVID-19 case fatality ratio (CFR).
Methods: We examined access to intensive care beds by deriving (1) a regional ratio of intensive care beds to 100,000 population capita (accessibility index, AI) and (2) the distance to the closest intensive care unit. The cross-sectional analysis was performed at a 5-by-5 km spatial resolution and results were summarized nationally for 14 European countries. The relationship between AI and CFR was analyzed at the regional level.
Results: We found national-level differences in the levels of access to intensive care beds. The AI was highest in Germany (AI = 35.3), followed by Estonia (AI = 33.5) and Austria (AI = 26.4), and lowest in Sweden (AI = 5) and Denmark (AI = 6.4). The average travel distance to the closest hospital was highest in Croatia (25.3 min by car) and lowest in Luxembourg (9.1 min). Subnational results illustrate that capacity was associated with population density and national-level inventories. The correlation analysis revealed a negative correlation of ICU accessibility and COVID-19 CFR (r = − 0.57; p < 0.001).
Conclusion: Geographical access to intensive care beds varies significantly across European countries and low ICU accessibility was associated with a higher proportion of COVID-19 deaths to cases (CFR). Important differences in access are due to the sizes of national resource inventories and the distribution of health-care facilities relative to the human population. Our findings provide a resource for officials planning public health responses beyond the current COVID-19 pandemic, such as identifying potential locations suitable for temporary facilities or establishing logistical plans for moving severely ill patients to facilities with available beds.
The study of neutron-induced reactions is of high relevance in a wide variety of fields, ranging from stellar nucleosynthesis and fundamental nuclear physics to applications of nuclear technology. In nuclear energy, high accuracy neutron data are needed for the development of Generation IV fast reactors and accelerator driven systems, these last aimed specifically at nuclear waste incineration, as well as for research on innovative fuel cycles. In this context, a high luminosity Neutron Time Of Flight facility, n_TOF, is operating at CERN since more than a decade, with the aim of providing new, high accuracy and high resolution neutron cross-sections. Thanks to the features of the neutron beam, a rich experimental program relevant to nuclear technology has been carried out so far. The program will be further expanded in the near future, thanks in particular to a new high-flux experimental area, now under construction.
High precision measurement of the radiative capture cross section of 238U at the n_TOF CERN facility
(2017)
The importance of improving the accuracy on the capture cross-section of 238U has been addressed by the Nuclear Energy Agency, since its uncertainty significantly affects the uncertainties of key design parameters for both fast and thermal nuclear reactors. Within the 7th framework programme ANDES of the European Commission three different measurements have been carried out with the aim of providing the 238U(n,γ) cross-section with an accuracy which varies from 1 to 5%, depending on the energy range. Hereby the final results of the measurement performed at the n_TOF CERN facility in a wide energy range from 1 eV to 700 keV will be presented.
Neutron-induced fission cross sections of 238U and 235U are used as standards in the fast neutron region up to 200 MeV. A high accuracy of the standards is relevant to experimentally determine other neutron reaction cross sections. Therefore, the detection effciency should be corrected by using the angular distribution of the fission fragments (FFAD), which are barely known above 20 MeV. In addition, the angular distribution of the fragments produced in the fission of highly excited and deformed nuclei is an important observable to investigate the nuclear fission process.
In order to measure the FFAD of neutron-induced reactions, a fission detection setup based on parallel-plate avalanche counters (PPACs) has been developed and successfully used at the CERN-n_TOF facility. In this work, we present the preliminary results on the analysis of new 235U(n,f) and 238U(n,f) data in the extended energy range up to 200 MeV compared to the existing experimental data.
The n_TOF facility operates at CERN with the aim of addressing the request of high accuracy nuclear data for advanced nuclear energy systems as well as for nuclear astrophysics. Thanks to the features of the neutron beam, important results have been obtained on neutron induced fission and capture cross sections of U, Pu and minor actinides. Recently the construction of another beam line has started; the new line will be complementary to the first one, allowing to further extend the experimental program foreseen for next measurement campaigns.
The aim of this work is to provide a precise and accurate measurement of the 238U(n,γ) reaction cross section in the energy region from 1 eV to 700 keV. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behavior of the reactor core. In particular, fast reactors, which are experiencing a growing interest for their ability to burn radioactive waste, operate in the high energy region of the neutron spectrum. In this energy region most recent evaluations disagree due to inconsistencies in the existing measurements of up to 15%. In addition, the assessment of nuclear data uncertainty performed for innovative reactor systems shows that the uncertainty in the radiative capture cross section of 238U should be further reduced to 1–3% in the energy region from 20 eV to 25 keV. To this purpose, addressed by the Nuclear Energy Agency as a priority nuclear data need, complementary experiments, one at the GELINA and two at the n_TOF facility, were proposed and carried out within the 7th Framework Project ANDES of the European Commission. The results of one of these 238U(n,γ) measurements performed at the n_TOF CERN facility are presented in this work. The γ-ray cascade following the radiative neutron capture has been detected exploiting a setup of two C6D6 liquid scintillators. Resonance parameters obtained from this work are on average in excellent agreement with the ones reported in evaluated libraries. In the unresolved resonance region, this work yields a cross section in agreement with evaluated libraries up to 80 keV, while for higher energies our results are significantly higher.
We have measured the capture cross section of the 155Gd and 157Gd isotopes between 0.025 eV and 1 keV. The capture events were recorded by an array of 4 C6D6 detectors, and the capture yield was deduced exploiting the total energy detection system in combination with the Pulse Height Weighting Techniques. Because of the large cross section around thermal neutron energy, 4 metallic samples of different thickness were used to prevent problems related to self-shielding. The samples were isotopically enriched, with a cross contamination of the other isotope of less than 1.14%. The capture yield was analyzed with an R-Matrix code to describe the cross section in terms of resonance parameters. Near thermal energies, the results are significantly different from evaluations and from previous time-of-flight experiments. The data from the present measurement at n_TOF are publicly available in the experimental nuclear reaction database EXFOR.
New results are presented of the 234U neutron-induced fission cross section, obtained with high accuracy in the resonance region by means of two methods using the 235U(n,f) as reference. The recent evaluation of the 235U(n,f) obtained with SAMMY by L. C. Leal et al. (these Proceedings), based on previous n_TOF data [1], has been used to calculate the 234U(n,f) cross section through the 234U/235U ratio, being here compared with the results obtained by using the n_TOF neutron flux.
Accurate measurement of the standard 235U(n,f) cross section from thermal to 170 keV neutron energy
(2020)
An accurate measurement of the 235U(n,f) cross section from thermal to 170 keV of neutron energy has recently been performed at n_TOF facility at CERN using 6Li(n,t)4He and 10B(n,α)7Li as references. This measurement has been carried out in order to investigate a possible overestimation of the 235U fission cross section evaluation provided by most recent libraries between 10 and 30 keV. A custom experimental apparatus based on in-beam silicon detectors has been used, and a Monte Carlo simulation in GEANT4 has been employed to characterize the setup and calculate detectors efficiency. The results evidenced the presence of an overestimation in the interval between 9 and 18 keV and the new data may be used to decrease the uncertainty of 235U(n,f) cross section in the keV region.
The 236U isotope plays an important role in nuclear systems, both for future and currently operating ones. The actual knowledge of the capture reaction of this isotope is satisfactory in the thermal region, but it is considered insufficient for Fast Reactor and ADS applications. For this reason the 236U(n, γ) reaction cross-section has been measured for the first time in the whole energy region from thermal energy up to 1 MeV at the n_TOF facility with two different detection systems: an array of C6D6 detectors, employing the total energy deposited method, and a FX1 total absorption calorimeter (TAC), made of 40 BaF2 crystals. The two n_TOF data sets agree with each other within the statistical uncertainty in the Resolved Resonance Region up to 800 eV, while sizable differences (up to ≃ 20%) are found relative to the current evaluated data libraries. Moreover two new resonances have been found in the n_TOF data. In the Unresolved Resonance Region up to 200 keV, the n_TOF results show a reasonable agreement with previous measurements and evaluated data.