The scope of extracorporeal membrane oxygenation (ECMO) is expanding, nevertheless, pharmacokinetics in patients receiving cardiorespiratory support are fairly unknown leading to unpredictable drug concentrations. Currently, there are no clear guidelines for antibiotic dosing during ECMO. This study aims to evaluate the pharmacokinetics (PK) of cefazolin in patients undergoing ECMO treatment. Total and unbound plasma cefazolin concentration of critically ill patients on veno-arterial ECMO were determined. Observed PK was compared to dose recommendations calculated by an online available, free dosing software. Concentration of cefazolin varied broadly despite same dosage in all patients. The mean total and unbound plasma concentration were high showing significantly (p = 5.8913 E−09) greater unbound fraction compared to a standard patient. Cefazolin clearance was significantly (p = 0.009) higher in patients with preserved renal function compared with CRRT. Based upon the calculated clearance, the use of dosing software would have led to lower but still sufficient concentrations of cefazolin in general. Our study shows that a “one size fits all” dosing regimen leads to excessive unbound cefazolin concentration in these patients. They exhibit high PK variability and decreased cefazolin clearance on ECMO appears to compensate for ECMO- and critical illness-related increases in volume of distribution.
Cholinesterase alterations in delirium after cardiosurgery: a German monocentric prospective study
(2020)
Objectives: Postoperative delirium (POD) is a common complication after elective cardiac surgery. Recent evidence indicates that a disruption in the normal activity of the cholinergic system may be associated with delirium.
Design: Prospective observational study.
Setting: Single-centre at a European academic hospital.
Primary: and secondary outcome measures In our study the enzyme activities of acetylcholinesterase (AChE) and butyrylcholinesterase (BChE) were determined preoperatively as well as on the first and second postoperative day. The confusion assessment method for the intensive care unit was used to screen patients for the presence of POD.
Results: A total of 114 patients were included in the study. POD was associated with a decrease in BChE activity on postoperative day 1 (p=0.03). In addition, patients who developed POD, had significantly lower preoperative AChE activity than patients without POD (p<0.01). Multivariate analysis identified a preoperatively decreased AChE activity (OR 3.1; 95% CI 1.14 to 8.46), anticholinergic treatment (OR 5.09; 95% CI 1.51 to 17.23), elevated European System for Cardiac Operative Risk Evaluation (OR 3.68; 95% CI 1.04 to 12.99) and age (OR 3.02; 95% CI 1.06 to 8.62) to be independently associated with the development of POD.
Conclusions: We conclude that a reduction in the acetylcholine hydrolysing enzyme activity in patients undergoing cardiac surgery may correlate with the development of POD.
Background: Conditions during blood product storage and transportation should maintain quality. The aim of this in vitro study was to investigate the effect of interruption of agitation, temporary cooling (TC), and pneumatic tube system transportation (PTST) on the aggregation ability (AA) and mitochondrial function (MF) of platelet concentrates (PC).
Study Design and Methods: A PC was divided equally into four subunits and then allocated to four test groups. The control group (I) was stored as recommended (continuous agitation, 22 ± 2°C) for 4 days. The test groups were stored without agitation (II), stored as recommended, albeit 4°C for 60 minutes on day (d)2 (III) and PTST (IV). Aggregometry was measured using Multiplate (RocheAG; ADPtest, ASPItest, TRAPtest, COLtest) and MF using Oxygraph‐2k (Oroboros Instruments). The basal and maximum mitochondrial respiratory rate (MMRR) were determined. AA and MF were measured daily in I and II and AA in III and IV on d2 after TC/PTST. Statistical analysis was performed using tests for matched observations.
Results: Eleven PCs were used. TRAP‐6 induced AA was significantly lower in II when compared to I on d4 (P = 0.015*). In III the ASPItest was significantly lower (P = 0.032*). IV showed no significant differences. The basal and MMRR were significantly reduced over 4 days in I and II (for both rates in both groups: P = <0.0001*). No significant differences occurred on d4 (P = 0.495).
Conclusion: Our results indicate that ex vivo AA and MF of PCs are unaffected, even in no‐ideal storage and transport circumstances with respect to agitation, temperature, and force.
Introduction Patients undergoing heart valve surgery are predominantly transferred postoperatively to the intensive care unit (ICU) under continuous sedation. Volatile anaesthetics are an increasingly used treatment alternative to intravenous substances in the ICU. As subject to inhalational uptake and elimination, the resulting pharmacological benefits have been repeatedly demonstrated. Therefore, volatile anaesthetics appear suitable to meet the growing demands of fast-track cardiac surgery. However, their use requires special preparation at the bedside and trained medical and nursing staff, which might limit the pharmacological benefits. The aim of our work is to assess whether the temporal advantages of recovery under volatile sedation outweigh the higher effort of special preparation.
Methods and analysis The study is designed to evaluate the differences between intravenous sedatives (n=48) and volatile sedatives (n=48) in continued intensive care sedation. This study will be conducted as a prospective, randomised, controlled, single-blinded, monocentre trial at a German university hospital in consenting adult patients undergoing heart valve surgery at a university hospital. This observational study will examine the necessary preparation time, staff consultation and overall feasibility of the chosen sedation method. For this purpose, the continuation of sedation in the ICU with volatile sedatives is considered as one study arm and with intravenous sedatives as the comparison group. Due to rapid elimination and quick awakening after the termination of sedation, closer consultation between the attending physician and the ICU nursing staff is required, in addition to a prolonged setup time. Study analysis will include the required setup time, time from admission to extubation as primary outcome and neurocognitive assessability. In addition, possible operation-specific (blood loss, complications), treatment parameters (catecholamine dosages, lung function) and laboratory results (acute kidney injury, acid base balance (lactataemia), liver failure) as influencing factors will be collected. The study-relevant data will be extracted from the continuous digital records of the patient data management system after the patient has been discharged from the ICU. For statistical evaluation, 95% CIs will be calculated for the median time to extubation and neurocognitive assessability, and the association will be assessed with a Cox regression model. In addition, secondary binary outcome measures will be evaluated using Fisher’s exact tests. Further descriptive and exploratory statistical analyses are also planned.
Ethics and dissemination The study was approved by the Institutional Ethics Board of the University of Frankfurt, Germany (#20-1050). Informed consent of all individual patients will be obtained before randomisation. Results will be disseminated via publication in peer-reviewed journals.
The coronavirus pandemic continues to challenge global healthcare. Severely affected patients are often in need of high doses of analgesics and sedatives. The latter was studied in critically ill coronavirus disease 2019 (COVID-19) patients in this prospective monocentric analysis. COVID-19 acute respiratory distress syndrome (ARDS) patients admitted between 1 April and 1 December 2020 were enrolled in the study. A statistical analysis of impeded sedation using mixed-effect linear regression models was performed. Overall, 114 patients were enrolled, requiring unusual high levels of sedatives. During 67.9% of the observation period, a combination of sedatives was required in addition to continuous analgesia. During ARDS therapy, 85.1% (n = 97) underwent prone positioning. Veno-venous extracorporeal membrane oxygenation (vv-ECMO) was required in 20.2% (n = 23) of all patients. vv-ECMO patients showed significantly higher sedation needs (p < 0.001). Patients with hepatic (p = 0.01) or renal (p = 0.01) dysfunction showed significantly lower sedation requirements. Except for patient age (p = 0.01), we could not find any significant influence of pre-existing conditions. Age, vv-ECMO therapy and additional organ failure could be demonstrated as factors influencing sedation needs. Young patients and those receiving vv-ECMO usually require increased sedation for intensive care therapy. However, further studies are needed to elucidate the causes and mechanisms of impeded sedation.
High sedation needs of critically ill COVID-19 ARDS patients - a monocentric observational study
(2021)
Background: Therapy of severely affected coronavirus patient, requiring intubation and sedation is still challenging. Recently, difficulties in sedating these patients have been discussed. This study aims to describe sedation practices in patients with 2019 coronavirus disease (COVID-19)-induced acute respiratory distress syndrome (ARDS). Methods: We performed a retrospective monocentric analysis of sedation regimens in critically ill intubated patients with respiratory failure who required sedation in our mixed 32-bed university intensive care unit. All mechanically ventilated adults with COVID-19-induced ARDS requiring continuously infused sedative therapy admitted between April 4, 2020, and June 30, 2020 were included. We recorded demographic data, sedative dosages, prone positioning, sedation levels and duration. Descriptive data analysis was performed; for additional analysis, a logistic regression with mixed effect was used. Results: In total, 56 patients (mean age 67 (±14) years) were included. The mean observed sedation period was 224 (±139) hours. To achieve the prescribed sedation level, we observed the need for two or three sedatives in 48.7% and 12.8% of the cases, respectively. In cases with a triple sedation regimen, the combination of clonidine, esketamine and midazolam was observed in most cases (75.7%). Analgesia was achieved using sufentanil in 98.6% of the cases. The analysis showed that the majority of COVID-19 patients required an unusually high sedation dose compared to those available in the literature. Conclusion: The global pandemic continues to affect patients severely requiring ventilation and sedation, but optimal sedation strategies are still lacking. The findings of our observation suggest unusual high dosages of sedatives in mechanically ventilated patients with COVID-19. Prescribed sedation levels appear to be achievable only with several combinations of sedatives in most critically ill patients suffering from COVID-19-induced ARDS and a potential association to the often required sophisticated critical care including prone positioning and ECMO treatment seems conceivable.
Objectives: The ongoing coronavirus pandemic is challenging, especially in severely affected patients who require intubation and sedation. Although the potential benefits of sedation with volatile anesthetics in coronavirus disease 2019 patients are currently being discussed, the use of isoflurane in patients with coronavirus disease 2019–induced acute respiratory distress syndrome has not yet been reported. Design: We performed a retrospective analysis of critically ill patients with hypoxemic respiratory failure requiring mechanical ventilation. Setting: The study was conducted with patients admitted between April 4 and May 15, 2020 to our ICU. Patients: We included five patients who were previously diagnosed with severe acute respiratory syndrome coronavirus 2 infection. Intervention: Even with high doses of several IV sedatives, the targeted level of sedation could not be achieved. Therefore, the sedation regimen was switched to inhalational isoflurane. Clinical data were recorded using a patient data management system. We recorded demographical data, laboratory results, ventilation variables, sedative dosages, sedation level, prone positioning, duration of volatile sedation and outcomes. Measurements & Main Results: Mean age (four men, one women) was 53.0 (± 12.7) years. The mean duration of isoflurane sedation was 103.2 (± 66.2) hours. Our data demonstrate a substantial improvement in the oxygenation ratio when using isoflurane sedation. Deep sedation as assessed by the Richmond Agitation and Sedation Scale was rapidly and closely controlled in all patients, and the subsequent discontinuation of IV sedation was possible within the first 30 minutes. No adverse events were detected. Conclusions: Our findings demonstrate the feasibility of isoflurane sedation in five patients suffering from severe coronavirus disease 2019 infection. Volatile isoflurane was able to achieve the required deep sedation and reduced the need for IV sedation.
Background: Point of care devices for performing targeted coagulation substitution in patients who are bleeding have become increasingly important in recent years. New on the market is the Quantra. It is a device that uses sonorheometry, a sonic estimation of elasticity via resonance, which is a novel ultrasound-based technology that measures viscoelastic properties of whole blood. Several studies have already shown the comparability of the Quantra with devices already established on the market, such as the rotational thromboelastometry (ROTEM) device.
Objective: In contrast to existing studies, this study is the first prospective interventional study using this new system in a cardiac surgical patient cohort. We will investigate the noninferiority between an already existing coagulation algorithm based on the ROTEM/Multiplate system and a new algorithm based on the Quantra system for the treatment of coagulopathic cardiac surgical patients.
Methods: The study is divided into two phases. In an initial observation phase, whole blood samples of 20 patients obtained at three defined time points (prior to surgery, after completion of cardiopulmonary bypass, and on arrival in the intensive care unit) will be analyzed using both the ROTEM/Multiplate and Quantra systems. The obtained threshold values will be used to develop a novel algorithm for hemotherapy. In a second intervention phase, the new algorithm will be tested for noninferiority against an algorithm used routinely for years in our department.
Results: The main objective of the examination is the cumulative loss of blood within 24 hours after surgery. Statistical calculations based on the literature and in-house data suggest that the new algorithm is not inferior if the difference in cumulative blood loss is <150 mL/24 hours.
Conclusions: Because of the comparability of the Quantra sonorheometry system with the ROTEM measurement methods, the existing hemotherapy treatment algorithm can be adapted to the Quantra device with proof of noninferiority.
Trial Registration: ClinicalTrials.gov NCT03902275; https://clinicaltrials.gov/ct2/show/NCT03902275
International Registered Report Identifier (IRRID): DERR1-10.2196/17206