Refine
Document Type
- Master's Thesis (12) (remove)
Has Fulltext
- yes (12)
Is part of the Bibliography
- no (12)
Institute
- Physik (12)
The Time Projection Chamber (TPC), a large gaseous detector, is the main particle identification device of the ALICE experiment at the CERN LHC. The desired performance of the TPC defines the requirements for the gas mixture used in the detector. The active volume was filled with either Ne-CO2 (90-10) or Ne-CO2-N2 (90-10-5) during the first LHC running period. For LHC Run 2 the gas mixture is changed to Ar-CO2. Calculations of relevant gas properties are performed for Ar-based gas mixtures and compared to Ne-based gas mixtures to identify the most suitable Ar mixture. The drift velocity of ions in Ar is lower than in Ne. The closing time of the gating grid has to be adjusted accordingly to avoid drift field distortions due to back-drifting ions. The drift times of ions in the TPC readout chambers are calculated for the respective gas mixtures to determine the time to collect all ions from the amplification region. For LHC Run 3 the TPC readout chambers will be upgraded. The Multiwire Proportional Chambers (MWPCs) will be replaced by readout chambers based on Gas Electron Multipliers (GEMs) which are operated in continuous mode. As a consequence an ion backflow of the order of 1% causes significant space-charge distortions in the TPC drift volume. Similar distortions are expected in data taken specifically for the study of space-charge effects at the end of Run 1. The gating grid of the MWPCs is operated in the open state allowing the ions from the amplification region to enter the drift volume. The magnitude of the distortions in this data is measured and compared to the expectations for the TPC upgrade and results from current simulations.
Da in der Run 3 Periode des CERN LHC die Kollisionsrate auf 50 kHz erhöht werden soll, muss die ALICE TPC umgebaut werden. Die Vieldrahtproportionalkammern mit Sperrgitter sollen gegen eine GEM-basierte Auslese ausgetauscht werden, um eine kontinuierliche Auslese zu ermöglichen.
Es wurde eine GEM-Testkammer, die mit drei und vier GEM-Folien betrieben werden kann, entwickelt und gebaut. GEM-Folien wurden unter dem Mikroskop auf Fehler untersucht und auf ihre Spannungsfestigkeit hin getestet sowie gerahmt und in die Kammer eingesetzt. Mit der fertigen kleinen TPC mit GEM-basierter Auslese wurden IBF und Energieauflösung gemessen. Ziel der Messungen war es, einen möglichst geringen IBF von unter 1 % zu erhalten, um so wenig wie möglich Feldverzerrungen im Driftvolumen der TPC zu erhalten, bei gleichzeitig guter Energieauflösung von mindestens 12 %, um eine gute Teilchenidentifikation in der TPC sicherzustellen.
Da standard GEM-Konfigurationen mit nur drei GEM-Folien zwar eine gute Energieauflösung, jedoch zu viel IBF aufweisen, wurden die Messungen hauptsächlich mit vier GEM-Folien durchgeführt. Es wurden zwei verschiedene Arten von GEM-Folien verwendet, Standard (S) und Large-Pitch (LP) GEM-Folien, die bei einem Großteil der Messungen in der S-LP-LP-S-Konfiguration angeordnet waren.
Es wurde festgestellt, dass sich IBF und Energieauflösung gegenläufig verhalten, bei besser werdendem IBF also die Energieauflösung schlechter wird und umgekehrt.
Es wurden zwei verschiedene Gasmischungen, Ne-CO2-N2 (90-10-5) und Ar-CO2 (90-10), untersucht. Mit Neon wurde bei einem Gain von 2000 gemessen, mit Argon nur bei einem Gain von 1000, da bei Argon die Anzahl der produzierten Elektronen pro cm etwa doppelt so groß ist.
Der IBF war mit beiden Gasmischungen etwa gleich groß. Die Energieauflösung war mit Argon jedoch aufgrund des niedrigeren Gains erheblich schlechter. Mit Ne-CO2-N2 (90-10-5) gelang es, einen Arbeitspunkt mit einer Energieauflösung von etwa 12 % und einem IBF von unter 1 % zu finden, mit Ar-CO2 (90-10) war dies jedoch nicht der Fall.
Optimierung der Rekonstruktionsparameter zur Messung von Quarkonia im zentralen ALICE Detektor
(2011)
Seit den ersten Kollisionen im November 2009 läuft der LHC am CERN und dringt in noch nie dagewesene Energiebereiche vor. Die Schwerionenkollisionen innerhalb des ALICE Detektors sollen Aufschluss über die stark wechselwirkende Materie und ihre verschiedenen Phasen geben. Dem liegt die Untersuchung des Quark-Gluon-Plasmas zugrunde. Eine Signatur des Quark-Gluon-Plasmas ist die Rate von produzierten Quarkonia. Diese zerfallen in Leptonenpaare und sind damit zu identifizieren.
In der vorliegenden Arbeit wird diese Rate zur Messung von Quarkonia aufgegriffen und untersucht. Bei der Untersuchung der Simulation durch die Selektion der e++e--Paare, die ausschließlich aus einem J/y stammen, lässt sich ein Massenspektrum produzieren, das im Rahmen dieser Arbeit genauer betrachtet wurde. Durch die genaue Untersuchung der Bremsstrahlung und deren Lokalisierung lässt sich zeigen, dass besonders der ITS ein hohes Maß an Bremsstrahlungsprozessen mit sich bringt, was auf die große Materialanhäufung zurückzuführen ist. Um dies näher zu untersuchen, wurde das Augenmerk auf den ITS gelegt. Eines der wichtigsten Merkmale, die den Bremsstrahlungsprozess beschreiben, ist der Energieverlust. Durch die Bethe-Heitler-Funktion lässt sich der gesamte Detektor nur bedingt beschreiben. Erst die Betrachtung, die sich mit einer Einschränkung auf den ITS und den Azimutwinkel beschäftigt, zeigt eine genaue Beschreibung durch die Parameter der Funktion.
Nach der genauen Beschreibung der Bremsstrahlung wurden verschiedene Methoden entwickelt, in denen die Bremsstrahlungsprozesse innerhalb des invarianten Massenspektums der e++e--Paare ausgeschnitten werden können. Die Methoden der Selektion durch die Anzahl der Spurpunkte sowie die Selektion durch die Position der Spurpunkte zeigen, dass bereits minimale Selektionen ein sehr gutes Signal ergeben. Durch den Vergleich mit den herkömmlichen Selektionen SPDany und SPDfirst, zeigt sich, dass hierbei viel Signal verloren geht und diese Methode für bestimmte Analysen optimiert werden kann.
Durch die Anwendung auf die Datensätze, die während einer Strahlzeit im Jahr 2010 genommen wurden, bestätigte sich die Vermutung. Durch die Selektion von SPDany wird das Signal reduziert. Vergleicht man die Anzahl der Einträge im Signalbereich durch die Reduktion der Teilchen ohne Spurpunkte im ITS (NITSpunkten>0) zu der Anzahl der Einträge durch SPDany, ergibt dies eine Verminderung von bis zu 40%. Die Ursache für den großen Verlust innerhalb des Signalbereichs wird zusätzlich verstärkt, indem der SPD durch Kühlungsprobleme ausgeschaltet ist.
Eine weitere Methode, die untersucht wurde, war die Reduktion der Auswirkungen von Bremsstrahlung mit Hilfe der Kinkanalyse. Diese Methode ließ keine qualitativen Rückschlüsse auf die Analyse der Bremsstrahlung zu.
Dennoch zeigt das Ergebnis, dass das Signal von J/y’s in Proton-Proton Kollisionen um mehr als 40% mehr Einträge verbessert werden kann und sich dieses Prinzip nicht nur theoretisch in den simulierten Daten niederschlägt sondern auch in den untersuchten Datensätzen. Nun gilt es, diese Methode auch in anderen Studien einzubauen, um so eine alltagstaugliche Überprüfung der Erkenntnisse zu gewährleisten.
During RUN3 (2021-2023) of the Large Hadron Collider, the Time Projection Chamber (TPC) of ALICE will be operated with quadruple stacks of Gas Electron Multipliers (GEMs). This technology will allow to overcome the rate limitation due to the gated operation of the Multi-Wire Proportional Chambers (MWPCs) used in RUN1 (2009-2013) and RUN2 (2015-2018).
As part of the Upgrade project, long-term irradiation tests, so called "ageing tests", have been carried out. A test setup with a detector using a quadruple stack of 10x10cm2 GEMs was built and operated in Ar-CO2 and Ne-CO2-N2 gas mixtures. The detector performance such as gas gain and energy resolution were monitored continuously. In addition, outgassing tests of materials used for the assembly process of the upgraded TPC were performed. To reach the expected dose of the GEM-based TPC, the detector was operated at much higher gains than the TPC. It was found, that the GEMs could keep their performance within the projected lifetime of the TPC. Most of the tested materials showed no negative impact on the detector. For the tested epoxy adhesive no certain conclusion could be drawn.
At much higher doses than expected for the upgraded TPC, a new phenomenon was observed, which changed the hole geometry of the GEMs and led to a degradation of the energy resolution. Even though its occurrence is not expected during the lifetime of the GEM-based TPC, simulations were carried out to study this effect more systematically. The simulations confirmed, that a change of the hole geometries of the GEMs, lead to an increase of the local gain variation, which results in a decrease of the energy resolution.
Furthermore the effect of methane as quench gas on GEMs was studied, even though this gas is not foreseen to be used in the TPC. From ageing tests with single-wire proportional counters it is well known that hydrocarbons are produced in the plasma of the avalanches, which cover the electrodes and lead to a degradation of the detector performance. Even though GEMs have a quite different geometry, the ageing tests showed, that also this technology tends to methane-induced ageing. A loss of gas gain as well as a degradation of the energy resolution due to deposits on the electrodes was monitored. A qualitative and quantitative comparison between ageing in GEMs and proportional counters was performed.
The measurement of dielectrons (electron-positron pairs) allows to investigate the properties of strongly interacting matter, in particular the Quark-Gluon Plasma (QGP), which is created in relativistic heavy-ion collisions at the LHC. The evolution of the collision can be probed via dielectrons since electrons do not interact strongly and are created during all stages of the collision. One of the interests in dielectron measurements is motivated by possible modifications of the electromagnetic emission spectrum in the QGP, where pp collisions are used as a medium-free reference. The dielectron spectrum consists of contributions from various processes. In order to estimate contributions of known dielectron sources, simulations of the so-called dielectron cocktail are performed. In this thesis, dielectron cocktails in minimum bias pp collisions at p s = 7 TeV, p–Pb collisions at p sNN = 5.02 TeV and in central (0-10%) and semi-central (20-50%) Pb–Pb collisions at p sNN = 2.76 TeV at the LHC are presented.
Das CBM-Experiment konzentriert sich auf die Untersuchung der Eigenschaften des Quark-Gluon-Plasmas bei hohen Netto-Baryonendichten und moderaten Temperaturen. An der zukünftigen Beschleunigeranlage FAIR an der GSI findet das Experiment, neben vielen anderen Experimenten, ihren Platz. Der TRD ist, neben dem RICH, STS und TOF, einer der zentralen Detektoren im CBM-Experiment. Der TRD nutzt dabei den physikalischen Effekt der Übergangsstrahlung, die durch ein geladenes Teilchen beim Durchqueren einer Grenze zweier Medien mit unterschiedlichen Dielektrizitätskonstanten mit einer gewissen Wahrscheinlichkeit entsteht, um Elektronen von Pionen trennen zu können. Im Jahr 2017 wurde an der DESY 4 TRD-Prototypen in einer Teststrahlzeit getestet. Dabei handelt es sich um große TRD-Module mit den Maßen 95 · 95 cm2 , was dem finalen Design sehr nahe kommt. Die Untersuchung der DESY-Daten in Kapitel 5 brachte große Problematiken in den Daten zum Vorschein. Die Hauptprobleme der DESY-Daten sind: 1) Bug des SPADIC-Chips 2.0, bei der FN-Trigger zeitlich verschoben wurden; 2) schwache und suboptimale Trigger-Bedingung, wodurch sehr viel Rauschen aufgenommen wurde. Die Daten müssen für weitere Auswertung aufbereitet werden, wobei sehr viel Information und Statistik verloren geht, da einige Daten durch diverse Probleme nicht mehr rekonstruierbar sind. Kapitel 6 beschäftigt sich mit der Simulation der Detektorantwort und geht genauer auf die einzelnen Schritte, die zur Simulation des vom SPADIC erzeugten Pulses benötigt werden, ein. Am Ende werden Ergebnisse aus beiden Datensätzen miteinander verglichen. Um einen optimalen Vergleich zu gewähren, wird die Simulation bestmöglich an die Einstellungen in der Teststrahlzeit angepasst. Hauptsächlich geht es um die Erhöhung des Gasgains und der Verschiebung der Peaking-Zeit des Pulses. Im Allgemeinen können wir in der Simulation einige Effekte, die auch in den DESY-Daten vorkommen, nachsimulieren. Wir erhalten zum Teil sehr unterschiedliche Ergebnisse in der Simulation, deren Richtigkeit nicht verifiziert werden kann, da die Daten aufgrund der Probleme unzuverlässig werden. Durch die Analyse der DESY-Daten konnten wir die Problematik in den Daten besser verstehen. Eine sinnvolle Anpassung der Simulation wird durch die Unzuverlässigkeit der DESY-Daten unmöglich. Für die Optimierung der Simulation müsste man einen Vergleich mit neueren, zuverlässigeren Daten aus zukünftigen Teststrahlzeiten nehmen.
Im Rahmen dieser Arbeit wurde die Messung von ψ(2S) Mesonen mit dem ALICE-Experiment am LHC untersucht. Das ψ(2S) gehört zur Familie der Charmonia und kann sowohl in Proton-Proton- als auch in Nukleon-Nukleon-Kollisionen erzeugt werden und ist daher ein wichiger Parameter in den Studien dieser. Die Rate, mit der ψ(2S) durch verschiedene Mechanismen erzeugt werden, liefert Informationen über den Ablauf der Kollision und ist ein hilfreicher Faktor bei der Suche nach dem Quark-Gluon Plasma. Da es sich beim ψ(2S) um ein Charmonium handelt, das in niedrigere Charmoniumzustände zerfallen kann, ist das Verständis des ψ(2S) ebenso für Studien anderer Charmonia, wie dem J/ψ(1S), relevant.
ω(782) und ϕ(1020) Mesonenproduktion durch Dielektronen in pp-Kollisionen bei √s = 7 TeV mit ALICE
(2013)
Die Niedrigmassendielektronen (Elektron-Positron Paare mit kleiner invarianten Masse) sind wichtige experimentelle Sonden, um die Eigenschaften des in ultra-relativistischen Schwerionenkollisionen erzeugten heißen und dichten Mediums zu untersuchen. Elektronen koppeln nicht an die starke Wechselwirkung, weshalb sie wichtige Informationen über die gesamten Kollisionsphasen geben. Die Zerfälle von ω(782) und ϕ(1020)-Mesonen in Dielektronen ermöglichen es, besonders wichtige Informationen über ihre In-Medium-Eigenschaften zu erhalten, da Proton-Proton (pp)-Kollisionen als mediumfreie Referenz angenommen werden. Außerdem sind pp-Kollisionen auch für sich genommen interessant, um die Teilchenproduktion im Energiebereich des LHC (Large Hadron Collider) zu untersuchen.
In dieser Analyse werden die Elektronen im mittleren Rapiditätsbereich von |η| < 0.8 mit ITS (Inner Tracking System), TPC (Time Projection Chamber) und TOF (Time of Flight) gemessen.
Die transversalen Impulsspektren der ω(782) und ϕ(1020)-Mesonen im e+e--Zerfallskanal in pp-Kollisionen bei p √s = 7 TeV werden gezeigt. Das transversale Impulsspektrum des ω(782)-Mesons im e+e--Zerfallskanal wird mit den pT-Spektren in den µ+µ--und in den π0π+π--Zerfallskanälen verglichen, während das pT-Spektrum vom ϕ(1020)-Meson im e+e--Zerfallskanal mit den pT-Spektren in µ+µ-- und K+K--Zerfallskanälen verglichen wird.
Anisotropic collective flow of protons resulting from non-central heavy ion collisions is a unique hadronic observable providing information about the early stage of the nuclear collision. The analysis of collective flow in the energy regime between 1-2 AGeV enables the study of the phase diagram of hadronic matter at a high baryochemical potential µb, as well as the analysis of the equation of state at densities up to the threefold of the ground state density ρ0.
The algorithms of the standard event plane method and the scalar product method are used to analyse directed and elliptic flow of protons in a centrality range of 0-40 % most central events.
Prior to the analysis of experimental data, the respective influence of the reconstruction procedure on the algorithms is examined using Monte Carlo simulations based on the Ultra relativistic Quantum Molecular Dynamics (UrQMD) model.
Subsequently, experimental data measured in April 2012 with the High Acceptance DiElectron Spectrometer (HADES) is analysed using both methods. About 7.3 · 109 Au+Au events at a kinetic beam energy of 1.23 AGeV, equivalent to a centre of mass energy of √sNN = 2.42 GeV were recorded. A multi-differential analysis is feasible as the HADES detector provides a good transverse momentum and rapidity coverage.
Both algorithms result in identical values for directed and elliptic flow across all centrality classes within the observable phase space of protons. The calculated integrated value of v2 at mid rapidity is in good agreement with world data.
Electron identification with a likelihood method and measurements of di-electrons for the CBM-TRD
(2017)
In this work a likelihood method has been implemented and investigated as particle identification algorithm for the CBM-TRD.
The creation of the probability distributions for the likelihood method via V0-topologies seems to be feasible and the purity of the obtained samples is sufficient for the usage in the likelihood method.
The comparison between the ANN and the likelihood method shows no differences in the identification performance. The pion suppression factor reaches the same values for the same electron identification efficiencies and the yields of the resulting di-lepton signals are comparable. The signal-to-background ratios for both methods have the same values and show a value of about 10−2 in the invariant mass range of minv = 1.5 - 2.5 GeV/c2, which is expected to be sufficient to provide access to the thermal in-medium and QGP radiation.
The investigation of a detector system without a TRD shows no pion suppression for a momentum above p = 6 GeV/c. Therefore, the background contributions increase drastically and the signal-to-background ratio decreases at all invariant masses, but especially in the invariant mass range of minv = 1.5 - 2.5 GeV/c2.
The background contributions in the invariant mass range of minv = 1.5 - 2.5 GeV/c 2 are also influenced by the selected electron identification efficiency of the TRD, which significantly shifts the fraction of the eπ contributions relative to the total number of pairs.