ALICE (A Large Ion Collider Experiment), is the dedicated heavy-ion experiment at the Large Hadron Collider (LHC) at CERN. It is optimised to reconstruct and identify the particles created in a lead-lead collision with a centre of mass energy of 5.5TeV. The main tracking detector is a large-volume time-projection chamber (TPC). With an active volume of about 88m^3 and a total readout area of 32.5m^2 it is the most challenging TPC ever build. A central electrode divides the 5m long detector into two drift regions. Each readout side is subdivided into 18 inner and 18 outer multi-wire proportional read-out chambers. The readout area is subdivide into 557568 pads, where each pad is read out by and electronics chanin. A complex calibration is needed in order to reach the design position-resolution of the reconstructed particle tracks of about 200um. One part of the calibration lies in understanding the electronic-response. The work at hand presents results of the pedestal and noise behaviour of the front-end electronics (FEE), measurements of the pulse-shaping properties of the FEE using results obtained with a calibration pulser and measurements performed with the laser-calibration system. The data concerned were taken during two phases of the TPC commissioning. First measurements were performed in the clean room where the TPC was built. After the TPC was moved underground and built into the experiment, a second round of commissioning took place. Noise measurements in the clean room revealed a very large fraction of pads with noise values larger than the design specifications. The unexpected high noise values could be explained by the 'ground bounce' effect. Two modifications helped to reduce this effect: A desynchronisation in the the start of the readout of groups of channels and a modification in the grounding scheme of the FEE. Further noise measurements were carried out after the TPC has been moved to the experimental area underground. Here even a larger fraction of channels showed too large noise values. This could be traced back to a common mode current injected by the electronics power supplies. To study the shaping properties of the FEE a calibration pulser was used. To generate signals in the FEE a pulse is injected to the cathode wires of the read-out chambers. Due to manufacturing tolerances slight channel-by-channel variations of the shaping properties are expected. This effects the determination of the arrival time as well as the measured integral signal of the induced charge and has to be corrected. The measured arrival time variations follow a Gaussian distribution with a width (sigma) of 6.2ns. This corresponds to an error of the cluster position of about 170um. The charge variations are on the level of 2.8%. In order to reach the intrinsic resolution on the measurement of the specific energy loss of the particles (6%) those variations have to be taken into account. The photons of the laser-calibration system are energetic enough to emit photo electrons off metallic surfaces. Most interesting for the detector calibration are photo electrons from the central electrode. The laser light is intense enough to get a signal in all readout channels of the TPC. Since the central electrode is a smooth surface, differences in the arrival time between sectors reveal mechanical displacements of the readout sectors and can be used to correct for this effect. In addition the measurements can be used to determine the electron drift velocity in the TPC gas. The drift velocity measurements have shown a vertical as well as a radial gradient. The first can be explained by the temperature gradient, which naturally builds up in the 5m high detector. The second gradient is most probably caused by a relative conical deformation of the readout plane and the central electrode.
The ALICE Time Projection Chamber (TPC) is the main tracking detector of ALICE which was designed to perform well at multiplicities of up to 20000 charged primary and secondary tracks emerging from Pb-Pb collisions. Successful operation of such a large and complex detector requires an elaborate calibration and commissioning. The main goal for the calibration procedures is to provide the information needed for the offline software for the reconstruction of the particle tracks with sufficient precision so that the design performance can be achieved. For a precise reconstruction of particle tracks in the TPC, the calibration of the drift velocity, which in conjunction with the drift time provides the z position of the traversing particles, is essential. In this thesis, an online method for the calibration of the drift velocity is presented. It uses the TPC Laser System which generates 336 straight tracks within the active volume of the TPC. A subset of these tracks, showing sufficiently small distortions, is used in the analysis. The resulting time dependent drift velocity correction parameters are entered into a database and provide start values for the offline reconstruction chain of ALICE. Even though no particle tracking information is used, the online drift velocity calibration is in agreement with the full offline calibration including tracking on the level of about 2 x 10 exp (-4). In chapter 2, a short overview of the ALICE detector, as well as the data taking model of the ALICE, is given. In chapter 3, the TPC detector is described in detail. Lastly in chapter 4, the online drift velocity calibration method is presented, together with a detailed description of the TPC laser system.
The Compressed Baryonic Matter (CBM) is one of the core experiments at the future Facility for Anti-proton and Ion Research (FAIR), Darmstadt, Germany. Its goal is to investigate nuclear matter characteristics at high net-baryon densities and moderate temperatures. The Silicon Tracking System (STS) is a central detector system of CBM.
It is placed inside a 1Tm magnet and operated at a temperature of about −10 °C to keep radiation-induced bulk current in the 300μm double-sided microstrip silicon sensors low. The design of the STS aims to minimize the material budget in the detector acceptance (2.5° < θ < 25°). In order to do so, the readout electronics is placed outside the active area, and the analog signals are transported via ultra-thin micro-cables. The STS comprises eight tracking stations with 876 modules. Each module is assembled on a carbon fiber ladder, which is subsequently mounted in the C-shaped aluminum frame.
The scope of the thesis focused on developing a modular control system framework that can be implemented for different sizes of experimental setups. The developed framework was used for setups that required a remote operation, like the irradiation of the powering modules for the front-end electronics (FEE), but also in laboratory-based setups where the automation and archiving were needed (thermal cycling of the STS electronics).
The low voltage powering modules will be placed in the vicinity of the experiment, therefore they will experience a total dose of up to 40mGy over the 10 years of STS lifetime.
To estimate the effects of the radiation on the low-voltage module performance, a dedicated irradiation campaign took place. It aimed at estimating the rate of radiation induced soft errors, that lead to the switch off of the FEE.
Regular power cycles of multiple front-end boards (FEBs) pose a risk to the experiment operation. Firstly, such behavior could negatively influence the physics performance but also have deteriorating effects on the hardware. It was further assessed what are the limitations of the FEBs with respect to the thermal cycling and the mechanical stress. The results served as an indication of possible failure modes of the FEB at the end of STS lifetime. Failure modes after repeated cycles and potential reasons were determined (e.g., Coefficient of Thermal Expansion (CTE) difference between the materials).
Due to the conditions inside the STS efficient temperature and humidity monitoring and control are required to avoid icing or water condensation on the electronics or silicon sensors. The most important properties of a suitable sensor candidate are resilience to the magnetic field, ionizing radiation tolerance, and fairly small size.
A general strategy for ambient parameters monitoring inside the STS was developed, and potential sensor candidates were chosen. To characterize the chosen relative humidity sensors the developed control framework was introduced. A sampling system with a ceramic sensor and Fiber Optic Sensors (FOS) were identified as reliable solutions for the distributed sensing system. Additionally, the industrial capacitive sensors will be used as a reference during the commissioning.
Two different designs of FOS were tested: a hygrometer and 5 sensors multiplexed in an array. The FOS hygrometer turned out to be a more reliable solution. One of the possible reasons for a worse performance is a relatively low distance between the subsequent sensors (15 cm) and a thicker coating. The results obtained from the time response study pointed out that the thinner coating of about 15μm should be a good compromise between the humidity sensitivity and the time response.
The implementation of the containerized-based control system framework for the mSTS is described in detail. The deployed EPICS-based framework proved to be a reliable solution and ensured the safety of the detector for almost 1.5 years. Moreover, the data related to the performance of the detector modules were analyzed and significant progress in the quality of modules was noted. Obtained data was also used to estimate the total fluence, which was based on the leakage current changes.
The developed framework provided a unique opportunity to automate and control different experimental setups which provided crucial data for the STS. Furthermore, the work underlines the importance of such a system and outlines the next steps toward the realization of a reliable Detector Control System for STS.