Universitätspublikationen
Refine
Document Type
- Article (2)
Language
- English (2) (remove)
Has Fulltext
- yes (2) (remove)
Is part of the Bibliography
- no (2)
Keywords
- Blood loss (2) (remove)
Institute
- Medizin (2)
Background: Trauma may be associated with significant to life-threatening blood loss, which in turn may increase the risk of complications and death, particularly in the absence of adequate treatment. Hydroxyethyl starch (HES) solutions are used for volume therapy to treat hypovolemia due to acute blood loss to maintain or re-establish hemodynamic stability with the ultimate goal to avoid organ hypoperfusion and cardiovascular collapse. The current study compares a 6% HES 130 solution (Volulyte 6%) versus an electrolyte solution (Ionolyte) for volume replacement therapy in adult patients with traumatic injuries, as requested by the European Medicines Agency to gain more insights into the safety and efficacy of HES in the setting of trauma care.
Methods: TETHYS is a pragmatic, prospective, randomized, controlled, double-blind, multicenter, multinational trial performed in two parallel groups. Eligible consenting adults ≥ 18 years, with an estimated blood loss of ≥ 500 ml, and in whom initial surgery is deemed necessary within 24 h after blunt or penetrating trauma, will be randomized to receive intravenous treatment at an individualized dose with either a 6% HES 130, or an electrolyte solution, for a maximum of 24 h or until reaching the maximum daily dose of 30 ml/kg body weight, whatever occurs first. Sample size is estimated as 175 patients per group, 350 patients total (α = 0.025 one-tailed, power 1–β = 0.8). Composite primary endpoint evaluated in an exploratory manner will be 90-day mortality and 90-day renal failure, defined as AKIN stage ≥ 2, RIFLE injury/failure stage, or use of renal replacement therapy (RRT) during the first 3 months. Secondary efficacy and safety endpoints are fluid administration and balance, changes in vital signs and hemodynamic status, changes in laboratory parameters including renal function, coagulation, and inflammation biomarkers, incidence of adverse events during treatment period, hospital, and intensive care unit (ICU) length of stay, fitness for ICU or hospital discharge, and duration of mechanical ventilation and/or RRT.
Discussion: This pragmatic study will increase the evidence on safety and efficacy of 6% HES 130 for treatment of hypovolemia secondary to acute blood loss in trauma patients.
Trial registration:Registered in EudraCT, No.: 2016-002176-27 (21 April 2017) and ClinicalTrials.gov, ID: NCT03338218 (09 November 2017).
More than 30% of the world's population are anemic with serious economic consequences including reduced work capacity and other obstacles to national welfare and development. Red blood cell transfusion is the mainstay to correct anemia, but it is also 1 of the top 5 overused procedures. Patient blood management (PBM) is a proactive, patient-centered, and multidisciplinary approach to manage anemia, optimize hemostasis, minimize iatrogenic blood loss, and harness tolerance to anemia. Although the World Health Organization has endorsed PBM in 2010, many hospitals still seek guidance with the implementation of PBM in clinical routine. Given the use of proven change management principles, we propose simple, cost-effective measures enabling any hospital to reduce both anemia and red blood cell transfusions in surgical and medical patients. This article provides comprehensive bundles of PBM components encompassing 107 different PBM measures, divided into 6 bundle blocks acting as a working template to develop institutions' individual PBM practices for hospitals beginning a program or trying to improve an already existing program. A stepwise selection of the most feasible measures will facilitate the implementation of PBM. In this manner, PBM represents a new quality and safety standard.