Universitätspublikationen
Refine
Year of publication
Document Type
- Article (13503)
- Part of Periodical (3462)
- Doctoral Thesis (3298)
- Contribution to a Periodical (2163)
- Book (2062)
- Working Paper (1886)
- Preprint (1551)
- Review (1063)
- Report (909)
- Conference Proceeding (692)
Language
- English (17058)
- German (13855)
- Portuguese (231)
- Spanish (123)
- Italian (66)
- French (64)
- Multiple languages (59)
- Turkish (12)
- Ukrainian (10)
- slo (7)
Keywords
- Deutschland (132)
- COVID-19 (95)
- inflammation (93)
- Financial Institutions (90)
- ECB (67)
- Capital Markets Union (65)
- SARS-CoV-2 (63)
- Financial Markets (61)
- Adorno (58)
- Banking Union (50)
Institute
- Medizin (6586)
- Präsidium (5087)
- Physik (3382)
- Wirtschaftswissenschaften (2284)
- Gesellschaftswissenschaften (2016)
- Biowissenschaften (1750)
- Frankfurt Institute for Advanced Studies (FIAS) (1575)
- Biochemie und Chemie (1394)
- Sustainable Architecture for Finance in Europe (SAFE) (1391)
- Informatik (1380)
This work focuses on the investigation of K+, K- and ϕ-meson production in Ag(1.58 A GeV)+Ag collisions. The energetically cheapest channel for direct K+ production in binary NN-collisions NN→NΛK+ lies at exactly this energy. For the remaining K- and ϕ-mesons, an excess energy of 0.31 GeV and 0.34 GeV in the centre of mass system has to be provided by the system. This makes these particles an excellent probe for effects inside the medium.
K+ and K- mesons can be reconstructed directly as they possess a cτ of approximately 3.7 m. Using the approximately 3 billion recorded Ag(1.58 A GeV)+Ag 0-30% most central collision events, all reconstructed K+ and K- within the detector acceptance are investigated for their kinematic properties and their particle production rates compared to a selection of existing models.
Thrombopoietin (Thpo) signals via its receptor Mpl and regulates megakaryopoiesis, hematopoietic stem cell (HSC) maintenance and post-transplant expansion. Mpl expression is tightly controlled and deregulation of Thpo/Mpl-signaling is linked to hematological disorders. Here, we constructed an intracellular-truncated, signaling-deficient Mpl protein which is presented on the cell surface (dnMpl). The transplantation of bone marrow cells retrovirally transduced to express dnMpl into wildtype mice induced thrombocytopenia, and a progressive loss of HSC. The aplastic BM allowed the engraftment of a second BM transplant without further conditioning. Functional analysis of the truncated Mpl in vitro and in vivo demonstrated no internalization after Thpo binding and the inhibition of Thpo/Mpl-signaling in wildtype cells due to dominant-negative (dn) effects by receptor competition with wildtype Mpl for Thpo binding. Intracellular inhibition of Mpl could be excluded as the major mechanism by the use of a constitutive-dimerized dnMpl. To further elucidate the molecular changes induced by Thpo/Mpl-inhibition on the HSC-enriched cell population in the BM, we performed gene expression analysis of Lin-Sca1+cKit+ (LSK) cells isolated from mice transplanted with dnMpl transduced BM cells. The gene expression profile supported the exhaustion of HSC due to increased cell cycle progression and identified new and known downstream effectors of Thpo/Mpl-signaling in HSC (namely TIE2, ESAM1 and EPCR detected on the HSC-enriched LSK cell population). We further compared gene expression profiles in LSK cells of dnMpl mice with human CD34+ cells of aplastic anemia patients and identified similar deregulations of important stemness genes in both cell populations. In summary, we established a novel way of Thpo/Mpl inhibition in the adult mouse and performed in depth analysis of the phenotype including gene expression profiling.
Cytochrome c oxidases (CcOs), members of the heme-copper containing oxidase (HCO) superfamily, are the terminal enzymes of aerobic respiratory chains. The cbb3-type cytochrome c oxidases (cbb3-CcO) form the C-family and have only the central catalytic subunit in common with the A- and B-family HCOs. In Pseudomonas stutzeri, two cbb3 operons are organized in a tandem repeat. The atomic structure of the first cbb3 isoform (Cbb3-1) was determined at 3.2 Å resolution in 2010 (S. Buschmann, E. Warkentin, H. Xie, J. D. Langer, U. Ermler, and H. Michel, Science 329:327-330, 2010, http://dx.doi.org/10.1126/science.1187303). Unexpectedly, the electron density map of Cbb3-1 revealed the presence of an additional transmembrane helix (TMH) which could not be assigned to any known protein. We now identified this TMH as the previously uncharacterized protein PstZoBell_05036, using a customized matrix-assisted laser desorption ionization (MALDI)-tandem mass spectrometry setup. The amino acid sequence matches the electron density of the unassigned TMH. Consequently, the protein was renamed CcoM. In order to identify the function of this new subunit in the cbb3 complex, we generated and analyzed a CcoM knockout strain. The results of the biochemical and biophysical characterization indicate that CcoM may be involved in CcO complex assembly or stabilization. In addition, we found that CcoM plays a role in anaerobic respiration, as the ΔCcoM strain displayed altered growth rates under anaerobic denitrifying conditions.om Pseudomonas stutzeri, a bacterium closely related to the human pathogen Pseudomonas aeruginosa.
Testing for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) by RT-PCR is a vital public health tool in the pandemic. Self-collected samples are increasingly used as an alternative to nasopharyngeal swabs. Several studies suggested that they are sufficiently sensitive to be a useful alternative. However, there are limited data directly comparing several different types of self-collected materials to determine which material is preferable. A total of 102 predominantly symptomatic adults with a confirmed SARS-CoV-2 infection self-collected native saliva, a tongue swab, a mid-turbinate nasal swab, saliva obtained by chewing a cotton pad and gargle lavage, within 48 h of initial diagnosis. Sample collection was unsupervised. Both native saliva and gargling with tap water had high diagnostic sensitivity of 92.8% and 89.1%, respectively. Nasal swabs had a sensitivity of 85.1%, which was not significantly inferior to saliva (p = 0.092), but 16.6% of participants reported they had difficult in self-collection of this sample. A tongue swab and saliva obtained by chewing a cotton pad had a significantly lower sensitivity of 74.2% and 70.2%, respectively. Diagnostic sensitivity was not related to the presence of clinical symptoms or to age. When comparing self-collected specimens from different material, saliva, gargle lavage or mid-turbinate nasal swabs may be considered for most symptomatic patients. However, complementary experiments are required to verify that differences in performance observed among the five sampling modes were not attributed to collection impairment.
Background: To minimize the risk of disease transmission in cornea transplantation, donor screening for blood-derived viral infections is mandatory. Ideally, pre-mortem blood samples are used, but based on availability, cadaveric blood samples of cornea donors may also be used. However, serological and nucleic acid amplification tests (NATs) need to be validated for the use of cadaveric specimens.
Methods: Hepatitis B virus (HBV), hepatitis C virus (HCV), human immunodeficiency virus (HIV), human T-lymphotropic virus (HTLV) 1/2, and Treponema pallidum (syphilis)-specific serological and/or NAT assays were validated on different platforms (Abbott Alinity i, Alinity m, Roche Cobas 6800, and Roche Cobas AmpliPrep/Cobas TaqMan (CAP/CTM)) using (un)spiked paired pre- and post-mortem cornea donor blood samples from the same individual (up to 23.83 h after death) of 28 individuals in accordance with the specifications of the German Federal Institute for Vaccines and Biomedicines (Paul-Ehrlich-Institut [PEI]). In addition, routinely HBV-, HCV- and HIV-PCR-negative tested post-mortem blood samples of 24 individuals were used to assess NAT specificity.
Results: For the majority of serological parameters on the Abbott Alinity i (HBsAg, anti-HBc, anti-HBs, anti-HCV, anti-HIV, anti-HTLV 1/2, and anti-Treponema pallidum), ratios of generated test results of (un)spiked paired pre- and post-mortem blood samples differed ≤25%, with an agreement of qualitative pre- and post-mortem test results ranging from 91.2 to 100%. For NAT parameters (HBV, HCV, and HIV) on the Cobas 6800, Alinity m, and CAP/CTM, no significant deviation in virus concentrations (factor >5) of spiked pre- and post-mortem blood samples could be observed. Ct-values of corresponding internal controls did also not differ significantly (>1.5 Ct-values). In addition, no false-positive test results were generated when specificity was assessed.
Conclusion: Overall, fluctuations of test results for serological and NAT parameters in pre- and post-mortem blood samples examined in this study, were only limited and within the range of what is also observed when routinely testing fresh patient specimens. We conclude that all examined assays are eligible for the screening of blood samples taken up to about 24 h after the occurrence of death.
The plaque reduction neutralization test (PRNT) is a preferred method for the detection of functional, SARS-CoV-2 specific neutralizing antibodies from serum samples. Alternatively, surrogate enzyme-linked immunosorbent assays (ELISAs) using ACE2 as the target structure for the detection of neutralization-competent antibodies have been developed. They are capable of high throughput, have a short turnaround time, and can be performed under standard laboratory safety conditions. However, there are very limited data on their clinical performance and how they compare to the PRNT. We evaluated three surrogate immunoassays (GenScript SARS-CoV-2 Surrogate Virus Neutralization Test Kit (GenScript Biotech, Piscataway Township, NJ, USA), the TECO® SARS-CoV-2 Neutralization Antibody Assay (TECOmedical AG, Sissach, Switzerland), and the Leinco COVID-19 ImmunoRank™ Neutralization MICRO-ELISA (Leinco Technologies, Fenton, MO, USA)) and one automated quantitative SARS-CoV-2 Spike protein-based IgG antibody assay (Abbott GmbH, Wiesbaden, Germany) by testing 78 clinical samples, including several follow-up samples of six BNT162b2 (BioNTech/Pfizer, Mainz, Germany/New York, NY, USA) vaccinated individuals. Using the PRNT as a reference method, the overall sensitivity of the examined assays ranged from 93.8 to 100% and specificity ranged from 73.9 to 91.3%. Weighted kappa demonstrated a substantial to almost perfect agreement. The findings of our study allow these assays to be considered when a PRNT is not available. However, the latter still should be the preferred choice. For optimal clinical performance, the cut-off value of the TECO assay should be individually adapted.
Objectives: Regarding reactogenicity and immunogenicity, heterologous COVID-19 vaccination regimens are considered as an alternative to conventional immunization schemes.
Methods: Individuals receiving either heterologous (ChAdOx1-S [AstraZeneca, Cambridge, UK]/BNT162b2 [Pfizer-BioNTech, Mainz, Germany]; n = 306) or homologous (messenger RNA [mRNA]-1273 [Moderna, Cambridge, Massachusetts, USA]; n = 139) vaccination were asked to participate when receiving their second dose. Reactogenicity was assessed after 1 month, immunogenicity after 1, 3, and/or 6 months, including a third dose, through SARS-CoV-2 antispike immunoglobulin G, surrogate virus neutralization test, and a plaque reduction neutralization test against the Delta (B.1.167.2) and Omicron (B.1.1.529; BA.1) variants of concern.
Results: The overall reactogenicity was lower after heterologous vaccination. In both cohorts, SARS-CoV-2 antispike immunoglobulin G concentrations waned over time with the heterologous vaccination demonstrating higher neutralizing activity than homologous mRNA vaccination after 3 months to low neutralizing levels in the Delta plaque reduction neutralization test after 6 months. At this point, 3.2% of the heterologous and 11.4% of the homologous cohort yielded low neutralizing activity against Omicron. After a third dose of an mRNA vaccine, ≥99% of vaccinees demonstrated positive neutralizing activity against Delta. Depending on the vaccination scheme and against Omicron, 60% to 87.5% of vaccinees demonstrated positive neutralizing activity.
Conclusion: ChAdOx1-S/BNT162b2 vaccination demonstrated an acceptable reactogenicity and immunogenicity profile. A third dose of an mRNA vaccine is necessary to maintain neutralizing activity against SARS-CoV-2. However, variants of concern-adapted versions of the vaccines would be desirable.
Due to globally rising numbers of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections, resources for real-time reverse-transcription polymerase chain reaction (rRT-PCR)-based testing have been exhausted. In order to meet the demands of testing and reduce transmission, SARS-CoV-2 antigen-detecting rapid diagnostic tests (Ag-RDTs) are being considered. These tests are fast, inexpensive, and simple to use, but whether they detect potentially infectious cases has not been well studied. We evaluated three lateral flow assays (RIDA®QUICK SARS-CoV-2 Antigen (R-Biopharm), SARS-CoV-2 Rapid Antigen Test (Roche)), and NADAL® COVID-19 Ag Test (Nal von Minden GmbH, Regensburg, Germany) and one microfluidic immunofluorescence assay (SARS-CoV-2 Ag Test (LumiraDx GmbH, Cologne, Germany)) using 100 clinical samples. Diagnostic rRT-PCR and cell culture testing as a marker for infectivity were performed in parallel. The overall Ag-RDT sensitivity for rRT-PCR-positive samples ranged from 24.3% to 50%. However, for samples with a viral load of more than 6 log10 RNA copies/mL (22/100), typically seen in infectious individuals, Ag-RDT positivity was between 81.8% and 100%. Only 51.6% (33/64) of the rRT-PCR-positive samples were infectious in cell culture. In contrast, three Ag-RDTs demonstrated a more significant correlation with cell culture infectivity (61.8–82.4%). Our findings suggest that large-scale SARS-CoV-2 Ag-RDT-based testing can be considered for detecting potentially infective individuals and reducing the virus spread.
As the current SARS-CoV-2 pandemic continues, serological assays are urgently needed for rapid diagnosis, contact tracing and for epidemiological studies. So far, there is little data on how commercially available tests perform with real patient samples and if detected IgG antibodies provide protective immunity. Focusing on IgG antibodies, we demonstrate the performance of two ELISA assays (Euroimmun SARS-CoV-2 IgG & Vircell COVID-19 ELISA IgG) in comparison to one lateral flow assay ((LFA) FaStep COVID-19 IgG/IgM Rapid Test Device) and two in-house developed assays (immunofluorescence assay (IFA) and plaque reduction neutralization test (PRNT)). We tested follow up serum/plasma samples of individuals PCR-diagnosed with COVID-19. Most of the SARS-CoV-2 samples were from individuals with moderate to severe clinical course, who required an in-patient hospital stay.
For all examined assays, the sensitivity ranged from 58.8 to 76.5% for the early phase of infection (days 5-9) and from 93.8 to 100% for the later period (days 10-18) after PCR-diagnosed with COVID-19. With exception of one sample, all positive tested samples in the analysed cohort, using the commercially available assays examined (including the in-house developed IFA), demonstrated neutralizing (protective) properties in the PRNT, indicating a potential protective immunity to SARS-CoV-2. Regarding specificity, there was evidence that samples of endemic coronavirus (HCoV-OC43, HCoV-229E) and Epstein Barr virus (EBV) infected individuals cross-reacted in the ELISA assays and IFA, in one case generating a false positive result (may giving a false sense of security). This need to be further investigated.
Severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) serological assays are urgently needed for rapid diagnosis, contact tracing, and for epidemiological studies. So far, there is limited data on how commercially available tests perform with real patient samples, and if positive tested samples show neutralizing abilities. Focusing on IgG antibodies, we demonstrate the performance of two enzyme‐linked immunosorbent assay (ELISA) assays (Euroimmun SARS‐CoV‐2 IgG and Vircell COVID‐19 ELISA IgG) in comparison to one lateral flow assay (FaStep COVID‐19 IgG/IgM Rapid Test Device) and two in‐house developed assays (immunofluorescence assay [IFA] and plaque reduction neutralization test [PRNT]). We tested follow up serum/plasma samples of individuals polymerase chain reaction‐diagnosed with COVID‐19. Most of the SARS‐CoV‐2 samples were from individuals with moderate to the severe clinical course, who required an in‐patient hospital stay. For all examined assays, the sensitivity ranged from 58.8 to 76.5% for the early phase of infection (days 5‐9) and from 93.8% to 100% for the later period (days 10‐18).
Die exakte Positionierung von Intraokularlinsen in den Kapselsack ist von entscheidender Bedeutung für das postoperative visuelle Ergebnis nach Kataraktoperation oder refraktivem Linsenaustausch. Schon leichte Dezentrierungen können optische Aberrationen hervorrufen welche das Sehen der Patienten negativ beeinflussen. Besonders kommt dieses Phänomen bei sog. Premium Intraokularlinsen mit speziellen Optiken (asphärisch, torisch oder multifokal, sowie Kombinationen dieser) zum Tragen. Diese Optiken können Ihre gewünschte Wirkung nur bei exakter Positionierung entfalten. Eine postoperative Feinpositionierung ist nicht möglich, was die Ansprüche an den Operateur bei Implantation der Linsen erhöht. Minimalinvasive microinzisionelle Operationstechniken bieten heute gute Möglichkeiten, die Implantate exakt zu positionieren. Neben den Dezentrierungen können Intraokularlinsen auch dislozieren, beispielweise durch intra- oder postoperative Kapselrupturen, Linsenverziehungen oder auch Rotation der Implantate. Hier ist ein weiterer chirurgischer Eingriff von Nöten. Der Vortrag stellt dementsprechend verschiedene Videos und praktische Hinweise zur Handhabung postoperativer Linsendislokationen vor.
Im Rahmen des Vortrags wird zunächst ein Überblick über die aktuell angewandten Linsensysteme in der (refraktiven) Kataraktchirurgie sowie im Rahmen des RLA gesprochen. Hierzu zählen die monofokalen sphärischen Standardlinsen, aber auch asphärische, torische und multifokale Implantate.
Speziell wird auf die Ergebnisse einer Studie zu einem neuen multifokalen-torischen Implantat eingegangen. Der Schwerpunkt des Vortrages liegt dann weiterhin auf den trifokalen Korrektionsmöglichkeiten. Zum einen wird die sog. binokulare Trifokalität, bei der zwei multifokale Intraokularlinsen unterschiedlicher Addition implantiert werden, besprochen. Durch die Anpassung jeweils eines Auges an den Intermediär- bzw. Nahbereich soll so bei verringerten optischen Phänomenen ein deutliches Sehen in drei Hauptdistanzen ermöglicht werden. Weiterhin befasst sich der Vortrag aber auch mit den neuen echten trifokalen Optiksystemen, welche ebenfalls deutliches Sehen in verschiedenen Entfernungen gewährleisten können.
Im dritten Teil des Vortrages werden aktuelle Langzeitergebnisse aus einer FDA Studie zur Evaluation einer kammerwinkelgestützten phaken Intraokularlinse, mit speziellem Augenmerk auf den cornealen Endothelzellverlust, sowie eine neuartige sulcusgestütze phake Intraokularlinse mit zentralem Loch zur Glaukomvermeidung vorgestellt.
Fragestellung: Beurteilung der Korrektur des Astigmatismus mit der multifokalen torischen Intraokularlinsen (IOL) ReSTOR Toric (Alcon, Ft. Worth, USA) bei Kataraktoperation.
Methodik: Die Multicenterstudie umfasste Kataraktepatienten mit präoperativem Astigmatismus von ≥0,75 bis ≤2,5 dpt. die Patienten wurden einer bilateralen Implantation einer torischen multifokalen IOL zur Korrektur der Hornhautverkrümmung unterzogen. Die OP erfolgte ohne relaxierende limbale Inzisionen durch eine clear-cornea Inzision <3,0 mm. Prä- und postoperativ wurden für diese Subanalyse Autokeratometrie sowie subjektiver Astigmatismus von 39 Augen von 40 Patienten im Alter von 59,8±7,0 Jahren analysiert.
Ergebnisse: Präoperativ betrug der mittlere keratometrische Astigmatismus 1,43±0,57 dpt. Die mittlere Inzisionsgröße betrug 2,59±0,41 mm. 1 Monat postoperativ betrug der mittlere keratometrische Astigmatismus 1,51±0,95 dpt (25 Augen). Der Unterschied im keratometrischen Astigmatismus zwischen präoperativ und 1-Monat-postop betrug 0,57±0,96 dpt. Der präoperative subjektive Astigmatismus wurde signifikant von 0,32±0,33 dpt (25 Augen) auf 0,99±0,70 dpt reduziert. (39 Augen, p <0,0001).
Schlussfolgerung: Die Implantation der multifokale torischen IOL zeigt vorhersehbare postoperative Ergebnisse bei der Korrektur des Astigmatismus nach kataraktoperation.
This study explores how ‘gatherings’ turn into ‘encounters’ in a virtual world (VW) context. Most communication technologies enable only focused encounters between distributed participants, but in VWs both gatherings and encounters can occur. We present close sequential analysis of moments when after a silent gathering, interaction among participants in a VW is gradually resumed, and also investigate the social actions in the verbal (re-)opening turns. Our findings show that like in face-to-face situations, also in VWs participants often use different types of embodied resources to achieve the transition, rather than rely on verbal means only. However, the transition process in VWs has distinctive characteristics compared to the one in face-to-face situations. We discuss how participants in a VW use virtually embodied pre-beginnings to display what we call encounter-readiness, instead of displaying lack of presence by avatar stillness. The data comprise 40 episodes of video-recorded team interactions in a VW.
MiR144/451 expression is repressed by RUNX1 during megakaryopoiesis and disturbed by RUNX1/ETO
(2016)
Abstract: A network of lineage-specific transcription factors and microRNAs tightly regulates differentiation of hematopoietic stem cells along the distinct lineages. Deregulation of this regulatory network contributes to impaired lineage fidelity and leukemogenesis. We found that the hematopoietic master regulator RUNX1 controls the expression of certain microRNAs, of importance during erythroid/megakaryocytic differentiation. In particular, we show that the erythorid miR144/451 cluster is epigenetically repressed by RUNX1 during megakaryopoiesis. Furthermore, the leukemogenic RUNX1/ETO fusion protein transcriptionally represses the miR144/451 pre-microRNA. Thus RUNX1/ETO contributes to increased expression of miR451 target genes and interferes with normal gene expression during differentiation. Furthermore, we observed that inhibition of RUNX1/ETO in Kasumi1 cells and in RUNX1/ETO positive primary acute myeloid leukemia patient samples leads to up-regulation of miR144/451. RUNX1 thus emerges as a key regulator of a microRNA network, driving differentiation at the megakaryocytic/erythroid branching point. The network is disturbed by the leukemogenic RUNX1/ETO fusion product.
Author Summary: The regulatory network between transcription factors, epigenetic cofactors and microRNAs is decisive for normal hematopoiesis. The transcription factor RUNX1 is important for the establishment of a megakaryocytic gene expression program and the concomitant repression of erythroid genes during megakaryocytic differentiation. Gene regulation by RUNX1 is frequently disturbed by mutations and chromosomal translocations, such as the t(8;21) translocation, which gives rise to the leukemogenic RUNX1/ETO fusion protein. We found that RUNX1 regulates microRNAs, which are of importance at the megakaryocytic/erythroid branching point. Specifically, RUNX1 down-regulates expression of the microRNA cluster miR144/451 during megakaryocytic differentiation by changing the epigenetic histone modification pattern at the locus. We could show that miR451, one of the micorRNAs of the miR144/451 cluster, supports erythroid differentiation. We found that expression of miR451 is repressed by the RUNX1/ETO fusion protein, resulting in up regulation of miR451 target genes. Our data support the notion that RUNX1 suppresses the erythroid gene expression program including the erythroid microRNA miR451 and that the RUNX1/ETO fusion protein interferes with normal gene regulation by RUNX1.
People know surprisingly little about their own visual behavior, which can be problematic when learning or executing complex visual tasks such as search of medical images. We investigated whether providing observers with online information about their eye position during search would help them recall their own fixations immediately afterwards. Seventeen observers searched for various objects in “Where's Waldo” images for 3 s. On two-thirds of trials, observers made target present/absent responses. On the other third (critical trials), they were asked to click twelve locations in the scene where they thought they had just fixated. On half of the trials, a gaze-contingent window showed observers their current eye position as a 7.5° diameter “spotlight.” The spotlight “illuminated” everything fixated, while the rest of the display was still visible but dimmer. Performance was quantified as the overlap of circles centered on the actual fixations and centered on the reported fixations. Replicating prior work, this overlap was quite low (26%), far from ceiling (66%) and quite close to chance performance (21%). Performance was only slightly better in the spotlight condition (28%, p = 0.03). Giving observers information about their fixation locations by dimming the periphery improved memory for those fixations modestly, at best.
The dependence of the Escherichia coli Na+H+ antiporter A (EcNhaA) pH sensor mutant E241C on H+ and Na+ concentrations was tested using a solid supported membrane (SSM) based electrophysiological approach. Proteoliposome preparations with right side out (RSO) oriented carriers were used to investigate the passive downhill uptake mode (physiologically the reverse transport mode) at zero membrane potential. Na+ concentration gradients established with a rapid solution exchange acted as the driving force. When a Na+ concentration gradient was established at symmetrical pH, the transport activity of the E241C EcNhaA variant was similar to that of the wildtype EcNhaA, with no shift of the bell-shaped pH dependence, an increase of the KmNa at acidic pH and a decrease of the KmNa at alkaline pH, supporting the model of a competitive binding of Na+ and H+ to a common binding site.
This report was written by the organizers of the workshop "Accounting for Combat-Related Killings," which took place at the Goethe University Frankfurt in July 2014. Scholars from Israel, the United Kingdom, the United States,, Canada, and Germany came together to present and discuss case studies on the discourse practices involved in accounting for combat-related killings in different national and transnational contexts. Intending to reflect on the methodological skills needed to analyze newly available process data, the workshop brought together scholars using different methodological approaches (here mainly ethnomethodology and critical discourse analysis). In regard to the global trend towards increasing numbers of so called permanent, asymmetric, small, and permanent wars, the report turns to concepts, methods, and empirical findings that foster understandings of the difficulties war generates at social, cultural and political levels as well as the manner in which these predicaments are negotiated, denied, or deflected. The report summarizes the workshop by presenting the papers in a specific order, beginning with accounting in combat, followed by tribunals of accounting, and finally the sedimentation of accounting in cultural representations.
Ziel aller medizinischen und naturwissenschaftlichen Forschung seit Beginn der Ära der Operationen am offenen Herzen unter Einbeziehung der Herz-Lungen-Maschine ist die Untersuchung ihrer Pathogenität auf den menschlichen Körper. Den schädigenden Einfluss der extrakorporalen Zirkulation zu limitieren und damit die Induktion gerinnungsaktiver Substanzen so gering wie möglich zu halten ist eine der vordringlichen Ziele im Rahmen dieser Forschung. Die vorliegende Studie mit sechsundsiebzig eingeschlossenen Patienten hatte das Ziel, unter doppelblind - randomisierten - Bedingungen zu klären, ob beschichtete extrakorporale Kreisläufe wie das SMA - System der Firma COBE® insbesondere im Hinblick auf Drainageblutverlust, Substitutionsparameter und spezielle Gerinnungsparameter fiir den herzchirurgischen Patienten Vorteile bieten. Durchgängig ist bei den analysierten Parametern wie Blutverlust, Substitution von Erythrozytenkonzentraten und FFP' s, Nachbeatmungszeit, Intensivaufenthalt, Thrombozyten, Thrombozytenfunktion, Prothrombinfragmente F1+2, D - Dimer, und Antithrombin III ein Trend pro SMA zu erkennen, welcher allerdings insgesamt nicht signifikant ausflUlt. Positiv ist dabei zu erwähnen, dass das hier untersuchte SMA - System für den Patienten ein sicher eiuzusetzender extrakorporaler Kreislauf ist, welcher im Vergleich zum Standardsystem keinerlei Nachteile bietet. Die Gesamtheit der Werte gibt aber keine Veranlassung unter Routinebedingungen Kreisläufe mit SMA - Kopolymerbeschichtung herkömmlichen Standardsystemen vorzuziehen, da sie filr den Patienten mit keinem spürbaren klinischen Vorteil verbunden, derzeit aber noch ungleich teurer als das sonst verwendete vergleichbaren Standardsystem sind. Es ist somit noch ein weiter Weg zu wirklich biokompatiblen Oberflächen, welcher über verschiedenste Ansatzpunkte beschritten werden kann und noch sehr viel Forschung, Arbeit und Mühen fordern wird. Die Kopolymerbeschichtung extrakorporaler Oberflächen wie bei SMA kann in dieser Forschung entweder mit Verbesserungen weiterentwickelt und kombiniert werden, oder zugunsten vielversprechender anderweitiger Methoden wieder verlassen werden.