Corneal topometric, aberrometric and biomechanical parameters in mucopolysaccharidosis patients
(2019)
Aims: To report corneal topometric and aberrometric values in mucopolysaccharidosis (MPS) and to investigate their correlation with biomechanical corneal parameters.
Methods: One randomly chosen eye of 20 MPS patients with no to moderate corneal clouding and one eye of 23 healthy controls with comparable age were prospectively included into this study. Corneal surface regularity was assessed by index of surface variance (ISV), -vertical asymmetry (IVA), -height asymmetry (IHA), -height decentration (IHD); keratoconus index (KI), central keratoconus index (CKI) and Zernike indices of anterior and posterior corneal surface using Scheimpflug imaging (Pentacam). Corneal resistance factor (CRF) and corneal hysteresis (CH) were assessed by Ocular Response Analyzer. Statistical analyses were performed using Mann-Whitney-Test and Spearman Correlation Coefficients.
Results: IVA, ISV, IHD, IHA, but not KI and CKI were significantly higher in MPS patients compared to age matched healthy controls. Spherical aberration and asphericity coefficients either at the anterior or at the posterior corneal surface differed significantly between both groups. The grade of the MPS-associated corneal opacity correlated significantly with ISV (rho = 0.52), IVA (rho = 0.54), IHA (rho = 0.57) and IHD (rho = 0.48). Density of the MPS-affected corneas correlated significantly with ISV (rho = 0.52), IVA (rho = 0.72), IHA (rho = 0.57), IHD (rho = 0.69), 3rd order horizontal trefoil aberration at the posterior (rho = 0.62) and anterior surface (rho = 0.48) as well as with CH (rho = 0.55) and CRF (rho = 0.57). Spherical aberration at the back surface correlated with CRF and CH in MPS and in healthy controls.
Conclusions: This is the first study analyzing shape of the corneal surface in MPS patients. Topometric indices of corneal asymmetry are significantly increased and correlate with MPS-related corneal opacity and density. Spherical aberration and asphericity coefficient at the front and at the back corneal surface differ significantly between MPS and healthy controls.
Purpose: There is some controversy whether or not saccades change with age. This cross-sectional study aims to clarify the characteristics of reflexive saccades at various ages to establish a normative cohort in a standardized set-up. Second objective is to investigate the feasibility of saccadometry in daily ophthalmological practice.
Methods: One hundred healthy participants aged between 6 and 76 years underwent an ophthalmologic examination and saccadometry, using an infrared video-oculography device, sampling at 220 Hz. The reflexive saccades were evoked in four directions and three target displacements each (5°/15°/30° horizontally and of 5°/10°/20° vertically). Saccadic peak velocity, gain (amplitude/target displacement) and latency were measured.
Results: Mean peak velocity of saccades was 213°/s (± 29°/s), 352°/s (± 50°/s) and 455°/s (± 67°/s) to a target position 5°, 15°and 30° horizontally, respectively, and 208°/s (± 36°/s), 303°/s (± 50°/s) and 391°/s (± 71°/s) to a target position 5°, 10° and 20° vertically. The association between peak velocity and eccentricity proved to be present at any age in all four directions. We found no relevant effect of age on peak velocity, gain and latency in a fitted linear mixed model. However, latency becomes shorter during childhood and adolescence, while in adulthood it is relatively stable with a slight trend to increase in the elderly. Saccades are more precise when the target displacement is small. Isometric saccades are most common, followed by hypometric ones. All children and elderly were able to perform good quality saccadometry in a recording time of approximately 10 minutes.
Conclusion: The presented data may serve as normative control for further studies using such a video-oculography device for saccadometry. The means of peak velocity and the gain can be used independently from age respecting the target displacement. Latency is susceptible to age.