Medizin
Refine
Year of publication
Document Type
- Article (60)
- Conference Proceeding (2)
Language
- English (62)
Has Fulltext
- yes (62)
Is part of the Bibliography
- no (62)
Keywords
- Patient blood management (3)
- Transfusion (3)
- anaemia (3)
- cardiac surgery (3)
- patient blood management (3)
- transfusion (3)
- Cell salvage (2)
- Intensive care (2)
- SARS-CoV-2 (2)
- (cardiac) surgery (1)
- ARDS (1)
- Abdominal surgery (1)
- Anaemia (1)
- Anaesthesia (1)
- Anemia (1)
- Anesthesia, Intravenous (1)
- Auto transfusion (1)
- Biomarkers (1)
- Blood (1)
- Blood loss (1)
- Blood transfusion (1)
- COVID-19 (1)
- CRP (1)
- Case report (1)
- Children (1)
- Chlorides (1)
- Clonidine (1)
- Colloids (1)
- Coronary artery disease (CAD) (1)
- Critical haematocrit (1)
- D-dimer (1)
- ECMO (1)
- EZ-IO® needle driver (1)
- Electrolytes (1)
- Emergency medicine (1)
- Extracorporeal life support (1)
- FX06 (1)
- Gene polymorphism (1)
- Glucose Transporter Type 1 (1)
- Hematocrit value (1)
- Hemodilution (1)
- Hemostasis (1)
- IgGAM (1)
- Immunocompromised (1)
- In-line filtration (1)
- Infants (1)
- Inflammation (1)
- Infusion management (1)
- Innate immunity (1)
- Intensive care units (1)
- Intraosseous access (1)
- Ketogenic Diet (1)
- Metabolism, Inborn Errors (1)
- Migrants (1)
- Monosaccharide Transport Proteins (1)
- Mortality (1)
- Nicolaides-Baraitser syndrome (1)
- OPS (1)
- Oncologic surgery (1)
- Organ dysfunction (1)
- Oxygen consumption (1)
- Particles (1)
- Patient Blood Management (1)
- Pediatric patients (1)
- Pentaglobin (1)
- Peritonitis (1)
- Personalized medicine (1)
- Pneumonia (1)
- Rare Diseases (1)
- Red blood cell transfusion (1)
- Renal system (1)
- Restenosis (1)
- Sepsis (1)
- Severe bacterial infection (1)
- Surgery (1)
- Surgical and invasive medical procedures (1)
- Sympathicolysis (1)
- Toll-like receptor (TLR) 6 (1)
- Tracheal Intubation (1)
- Travellers (1)
- Videolaryngoscopy (1)
- acetylcholinesterase (1)
- acute kidney injury (1)
- acute respiratory distress syndrome (1)
- albumin (1)
- anaesthesia in orthopaedics (1)
- anaesthetics (1)
- angiogenesis (1)
- antioxidant defense (1)
- butyrylcholinesterase (1)
- cell salvage (1)
- children (1)
- cholinesterase (1)
- clinical studies (1)
- colloid (1)
- coronavirus disease 2019 (1)
- critical care (1)
- crystalloid (1)
- deep sedation (1)
- detoxification (1)
- elderly patients (1)
- endothelial activation (1)
- fluid (1)
- genetic polymorphisms (1)
- geriatric medicine (1)
- humoral factors (1)
- hypertonic (1)
- infant (1)
- inflammation (1)
- inflammatory cytokines (1)
- intensive care (1)
- iron deficiency (1)
- lung disease (1)
- meningioma (1)
- miRNA (1)
- molecular mechanisms (1)
- neonate (1)
- newborn (1)
- paediatric (1)
- postoperative delirium (1)
- preoperative anaemia management (1)
- primary mouse proximal tubular cells (1)
- propofol anesthesia (1)
- red blood cells (1)
- remote ischemic preconditioning (1)
- renal ischemia reperfusion injury (1)
- resolution (1)
- respiratory failure (1)
- resuscitation (1)
- risk prediction (1)
- sepsis (1)
- severe acute respiratory syndrome coronavirus 2 (1)
- shock (1)
- surgery (1)
- tubular regeneration (1)
- volatile sedation (1)
Institute
Transfusion of red blood cells (RBC) in patients undergoing major elective cranial surgery is associated with increased morbidity, mortality and prolonged hospital length of stay (LOS). This retrospective single center study aims to identify the clinical outcome of RBC transfusions on skull base and non-skull base meningioma patients including the identification of risk factors for RBC transfusion. Between October 2009 and October 2016, 423 patients underwent primary meningioma resection. Of these, 68 (16.1%) received RBC transfusion and 355 (83.9%) did not receive RBC units. Preoperative anaemia rate was significantly higher in transfused patients (17.7%) compared to patients without RBC transfusion (6.2%; p = 0.0015). In transfused patients, postoperative complications as well as hospital LOS was significantly higher (p < 0.0001) compared to non-transfused patients. After multivariate analyses, risk factors for RBC transfusion were preoperative American Society of Anaesthesiologists (ASA) physical status score (p = 0.0247), tumor size (p = 0.0006), surgical time (p = 0.0018) and intraoperative blood loss (p < 0.0001). Kaplan-Meier curves revealed significant influence on overall survival by preoperative anaemia, RBC transfusion, smoking, cardiovascular disease, preoperative KPS ≤ 60% and age (elderly ≥ 75 years). We concluded that blood loss due to large tumors or localization near large vessels are the main triggers for RBC transfusion in meningioma patients paired with a potential preselection that masks the effect of preoperative anaemia in multivariate analysis. Further studies evaluating the impact of preoperative anaemia management for reduction of RBC transfusion are needed to improve the clinical outcome of meningioma patients.
Background. Tracheal intubation still represents the "gold standard" in securing the airway of unconscious patients in the prehospital setting. Especially in cases of restricted access to the patient, video laryngoscopy became more and more relevant.
Objectives. The aim of the study was to evaluate the performance and intubation success of four different video laryngoscopes, one optical laryngoscope, and a Macintosh blade while intubating from two different positions in a mannequin trial with difficult access to the patient.
Methods. A mannequin with a cervical collar was placed on the driver’s seat. Intubation was performed with six different laryngoscopes either through the driver’s window or from the backseat. Success, C/L score, time to best view (TTBV), time to intubation (TTI), and number of attempts were measured. All participants were asked to rate their favored device.
Results. Forty-two physicians participated. 100% of all intubations performed from the backseat were successful. Intubation success through the driver’s window was less successful. Only with the Airtraq® optical laryngoscope, 100% success was achieved. Best visualization (window C/L 2a; backseat C/L 2a) and shortest TTBV (window 4.7 s; backseat 4.1 s) were obtained when using the D-Blade video laryngoscope, but this was not associated with a higher success through the driver’s window. Fastest TTI was achieved through the window (14.2 s) when using the C-MAC video laryngoscope and from the backseat (7.3 s) when using a Macintosh blade.
Conclusions. Video laryngoscopy revealed better results in visualization but was not associated with a higher success. Success depended on the approach and familiarity with the device. We believe that video laryngoscopy is suitable for securing airways in trapped accident victims. The decision for an optimal device is complicated and should be based upon experience and regular training with the device.
Objective: Videolaryngoscopy has mainly been developed to facilitate difficult airway intubation. However, there is a lack of studies demonstrating this method's efficacy in pediatric patients. The aim of the present study was to compare the TruView infant EVO2 and the C-MAC videolaryngoscope with conventional direct Macintosh laryngoscopy in children with a bodyweight ≤10 kg in terms of intubation conditions and the time to intubation.
Methods: In total, 65 children with a bodyweight ≤10 kg (0-22 months) who had undergone elective surgery requiring endotracheal intubation were retrospectively analyzed. Our database was screened for intubations with the TruView infant EVO2, the C-MAC videolaryngoscope, and conventional direct Macintosh laryngoscopy. The intubation conditions, the time to intubation, and the oxygen saturation before and after intubation were monitored, and demographic data were recorded. Only children with a bodyweight ≤10 kg were included in the analysis.
Results: A total of 23 children were intubated using the C-MAC videolaryngoscope, and 22 children were intubated using the TruView EVO2. Additionally, 20 children were intubated using a standard Macintosh blade. The time required for tracheal intubation was significantly longer using the TruView EVO2 (52 sec vs. 28 sec for C-MAC vs. 26 sec for direct LG). However, no significant difference in oxygen saturation was found after intubation.
Conclusion: All devices allowed excellent visualization of the vocal cords, but the time to intubation was prolonged when the TruView EVO2 was used. The absence of a decline in oxygen saturation may be due to apneic oxygenation via the TruView scope and may provide a margin of safety. In sum, the use of the TruView by a well-trained anesthetist may be an alternative for difficult airway management in pediatric patients.
Background Bacterial DNA containing motifs of unmethylated CpG dinucleotides (CpG-ODN) initiate an innate immune response mediated by the pattern recognition receptor Toll-like receptor 9 (TLR9). This leads in particular to the expression of proinflammatory mediators such as tumor necrosis factor (TNF-alpha) and interleukin-1beta (IL-1beta). TLR9 is expressed in human and murine pulmonary tissue and induction of proinflammatory mediators has been linked to the development of acute lung injury. Therefore, the hypothesis was tested whether CpG-ODN administration induces an inflammatory response in the lung via TLR9 in vivo. Methods Wild-type (WT) and TLR9-deficient (TLR9-D) mice received CpG-ODN intraperitoneally (1668-Thioat, 1 nmol/g BW) and were observed for up to 6 hrs. Lung tissue and plasma samples were taken and various inflammatory markers were measured. Results In WT mice, CpG-ODN induced a strong activation of pulmonary NFKB as well as a significant increase in pulmonary TNF-alpha and IL-1beta mRNA/protein. In addition, cytokine serum levels were significantly elevated in WT mice. Increased pulmonary content of lung myeloperoxidase (MPO) was documented in WT mice following application of CpG-ODN. Bronchoalveolar lavage (BAL) revealed that CpG-ODN stimulation significantly increased total cell number as well as neutrophil count in WT animals. In contrast, the CpG-ODN-induced inflammatory response was abolished in TLR9-D mice. Conclusion This study suggests that bacterial CpG-ODN causes lung inflammation via TLR9.
The main goal of adequate organ preservation is to avoid further cellular metabolism during the phase of ischemia. However, modern preservation solutions do rarely achieve this target. In donor organs hypoxia and ischemia induce a broad spectrum of pathologic molecular mechanisms favoring primary graft dysfunction (PGD) after transplantation. Increased hypoxia-induced transcriptional activity leads to increased vascular permeability which in turn is the soil of a reperfusion edema and the enhancement of a pro-inflammatory response in the graft after reperfusion. We hypothesize that inhibition of the respiration chain in mitochondria and thus inhibition of the hypoxia induced mechanisms might reduce reperfusion edema and consecutively improve survival in vivo. In this study we demonstrate that the rotenoid Deguelin reduces the expression of hypoxia induced target genes, and especially VEGF-A, dose-dependently in hypoxic human lung derived cells. Furthermore, Deguelin significantly suppresses the mRNA expression of the HIF target genes VEGF-A, the pro-inflammatory CXCR4 and ICAM-1 in ischemic lungs vs. control lungs. After lung transplantation, the VEGF-A induced reperfusion-edema is significantly lower in Deguelin-treated animals than in controls. Deguelin-treated rats exhibit a significantly increased survival-rate after transplantation. Additionally, a downregulation of the pro-inflammatory molecules ICAM-1 and CXCR4 and an increase in the recruitment of immunomodulatory monocytes (CD163+ and CD68+) to the transplanted organ involving the IL4 pathway was observed. Therefore, we conclude that ischemic periods preceding reperfusion are mainly responsible for the increased vascular permeability via upregulation of VEGF. Together with this, the resulting endothelial dysfunction also enhances inflammation and consequently lung dysfunction. Deguelin significantly decreases a VEGF-A induced reperfusion edema, induces the recruitment of immunomodulatory monocytes and thus improves organ function and survival after lung transplantation by interfering with hypoxia induced signaling.
Introduction: Acute kidney injury (AKI) can evolve quickly and clinical measures of function often fail to detect AKI at a time when interventions are likely to provide benefit. Identifying early markers of kidney damage has been difficult due to the complex nature of human AKI, in which multiple etiologies exist. The objective of this study was to identify and validate novel biomarkers of AKI.
Methods: We performed two multicenter observational studies in critically ill patients at risk for AKI - discovery and validation. The top two markers from discovery were validated in a second study (Sapphire) and compared to a number of previously described biomarkers. In the discovery phase, we enrolled 522 adults in three distinct cohorts including patients with sepsis, shock, major surgery, and trauma and examined over 300 markers. In the Sapphire validation study, we enrolled 744 adult subjects with critical illness and without evidence of AKI at enrollment; the final analysis cohort was a heterogeneous sample of 728 critically ill patients. The primary endpoint was moderate to severe AKI (KDIGO stage 2 to 3) within 12 hours of sample collection.
Results: Moderate to severe AKI occurred in 14% of Sapphire subjects. The two top biomarkers from discovery were validated. Urine insulin-like growth factor-binding protein 7 (IGFBP7) and tissue inhibitor of metalloproteinases-2 (TIMP-2), both inducers of G1 cell cycle arrest, a key mechanism implicated in AKI, together demonstrated an AUC of 0.80 (0.76 and 0.79 alone). Urine [TIMP-2].[IGFBP7] was significantly superior to all previously described markers of AKI (P <0.002), none of which achieved an AUC >0.72. Furthermore, [TIMP-2].[IGFBP7] significantly improved risk stratification when added to a nine-variable clinical model when analyzed using Cox proportional hazards model, generalized estimating equation, integrated discrimination improvement or net reclassification improvement. Finally, in sensitivity analyses [TIMP-2].[IGFBP7] remained significant and superior to all other markers regardless of changes in reference creatinine method.
Conclusions: Two novel markers for AKI have been identified and validated in independent multicenter cohorts. Both markers are superior to existing markers, provide additional information over clinical variables and add mechanistic insight into AKI. Trial registration: ClinicalTrials.gov number NCT01209169.
Background: The intraoperative blood loss is estimated daily in the operating room and is mainly done by visual techniques. Due to local standards, the surgical sponge colours can vary (e.g. white in US, green in Germany). The influence of sponge colour on accuracy of estimation has not been in the focus of research yet. Material and methods: A blood loss simulation study containing four “bleeding” scenarios each per sponge colour were created by using expired whole blood donation samples. The blood donations were applied to white and green surgical sponges after dilution with full electrolyte solution. Study participants had to estimate the absorbed blood loss in sponges in all scenarios. The difference to the reference blood loss was analysed. Multivariate linear regression analysis was performed to investigate other influence factors such as staff experience and sponge colour. Results: A total of 53 anaesthesists participated in the study. Visual estimation correlated moderately with reference blood loss in white (Spearman's rho: 0.521; p = 3.748*10−16) and green sponges (Spearman's rho: 0.452; p = 4.683*10−12). The median visually estimated blood loss was higher in white sponges (250ml IRQ 150–412.5ml) than in green sponges (150ml IQR 100-300ml), compared to reference blood loss (103ml IQR 86–162.8). For both colour types of sponges, major under- and overestimation was observed. The multivariate statistics demonstrates that fabric colours have a significant influence on estimation (p = 3.04*10−10), as well as clinician’s qualification level (p = 2.20*10−10, p = 1.54*10−08) and amount of RBL to be estimated (p < 2*10−16). Conclusion: The deviation of correct blood loss estimation was smaller with white surgical sponges compared to green sponges. In general, deviations were so severe for both types of sponges, that it appears to be advisable to refrain from visually estimating blood loss whenever possible and instead to use other techniques such as e.g. colorimetric estimation.
Background: Intraosseous (IO) access represents a reliable alternative to intravenous vascular access and is explicitly recommended in the current guidelines of the European Resuscitation Council when intravenous access is difficult or impossible. We therefore aimed to study the efficacy of the intraosseous needle driver EZ-IO(R) in the prehospital setting.
Methods: During a 24-month period, all cases of prehospital IO access using the EZ-IO(R) needle driver within three operational areas of emergency medical services were prospectively recorded by a standardized questionnaire that needed to be filled out by the rescuer immediately after the mission and sent to the primary investigator. We determined the rate of successful insertion of the IO needle, the time required, immediate procedure-related complications, the level of previous experience with IO access, and operator's subjective satisfaction with the device.
Results: 77 IO needle insertions were performed in 69 adults and five infants and children by emergency physicians (n=72 applications) and paramedics (n=5 applications). Needle placement was successful at the first attempt in all but 2 adults (one patient with unrecognized total knee arthroplasty, one case of needle obstruction after placement). The majority of users (92%) were relative novices with less than five previous IO needle placements. Of 22 responsive patients, 18 reported pain upon fluid administration via the needle. The rescuers' subjective rating regarding handling of the device and ease of needle insertion, as described by means of an analogue scale (0 = entirely unsatisfied, 10 = most satisfied), provided a median score of 10 (range 1-10).
Conclusions: The EZ-IO(R) needle driver was an efficient alternative to establish immediate out-of-hospital vascular access. However, significant pain upon intramedullary infusion was observed in the majority of responsive patients.
Background: Anemia is the most important complication during major surgery and transfusion of red blood cells is the mainstay to compensate for life threating blood loss. Therefore, accurate measurement of hemoglobin (Hb) concentration should be provided in real-time. Blood Gas Analysis (BGA) provides rapid point-of-care assessment using smaller sampling tubes compared to central laboratory (CL) services. Objective: This study aimed to investigate the accuracy of BGA hemoglobin testing as compared to CL services. Methods: Data of the ongoing LIBERAL-Trial (Liberal transfusion strategy to prevent mortality and anemia-associated ischemic events in elderly non-cardiac surgical patients, LIBERAL) was used to assess the bias for Hb level measured by BGA devices (ABL800 Flex analyzer®, GEM series® and RapidPoint 500®) and CL as the reference method. For that, we analyzed pairs of Hb level measured by CL and BGA within two hours. Furthermore, the impact of various confounding factors including age, gender, BMI, smoker status, transfusion of RBC, intraoperative hemodilution, and co-medication was elucidated. In order to ensure adequate statistical analysis, only data of participating centers providing more than 200 Hb pairs were used. Results: In total, three centers including 963 patients with 1,814 pairs of Hb measurements were analyzed. Mean bias was comparable between ABL800 Flex analyzer® and GEM series®: - 0.38 ± 0.15 g/dl whereas RapidPoint 500® showed a smaller bias (-0.09 g/dl) but greater median absolute deviation (± 0.45 g/dl). In order to avoid interference with different standard deviations caused by the different analytic devices, we focused on two centers using the same BGA technique (309 patients and 1,570 Hb pairs). A Bland-Altman analysis and LOWESS curve showed that bias decreased with smaller Hb values in absolute numbers but increased relatively. The smoker status showed the greatest reduction in bias (0.1 g/dl, p<0.001) whereas BMI (0.07 g/dl, p = 0.0178), RBC transfusion (0.06 g/dl, p<0.001), statins (0.04 g/dl, p<0.05) and beta blocker (0.03 g/dl, p = 0.02) showed a slight effect on bias. Intraoperative substitution of volume and other co-medications did not influence the bias significantly. Conclusion: Many interventions like substitution of fluids, coagulating factors or RBC units rely on the accuracy of laboratory measurement devices. Although BGA Hb testing showed a consistently stable difference to CL, our data confirm that BGA devices are associated with different bias. Therefore, we suggest that hospitals assess their individual bias before implementing BGA as valid and stable supplement to CL. However, based on the finding that bias decreased with smaller Hb values, which in turn are used for transfusion decision, we expect no unnecessary or delayed RBC transfusion, and no major impact on the LIBERAL trial performance.
Introduction: Systemic inflammation (e.g. following surgery) involves Toll-like receptor (TLR) signaling and leads to an endocrine stress response. This study aims to investigate a possible influence of TLR2 and TLR4 single nucleotide polymorphisms (SNPs) on perioperative adrenocorticotropic hormone (ACTH) and cortisol regulation in serum of cardiac surgical patients. To investigate the link to systemic inflammation in this context, we additionally measured 10 different cytokines in the serum. Methods: 338 patients admitted for elective cardiac surgery were included in this prospective observational clinical cohort study. Genomic DNA of patients was screened for TLR2 and TLR4 SNPs. Serum concentrations of ACTH, cortisol, interferon (IFN)-, interleukin (IL)-1, IL-2, IL-4, IL-5, IL-6, IL-8, IL-10, tumor necrosis factor (TNF)- and granulocyte macro-phage-colony stimulating factor (GM-CSF) were determined before surgery, immediately post surgery and on the first postoperative day. Results: 13 patients were identified as TLR2 SNP carrier, 51 as TLR4 SNP carrier and 274 pa-tients as non-carrier. Basal levels of ACTH, cortisol and cytokines did not differ between groups. In all three groups a significant, transient perioperative rise of cortisol could be ob-served. However, only in the non-carrier group this was accompanied by a significant ACTH rise, TLR4 SNP carriers had significant lower ACTH levels compared to non-carriers ((mean[95% confidence intervals]) non-carriers: 201.9[187.7 to 216.1]pg/ml; TLR4 SNP car-riers: 149.9[118.4 to 181.5]pg/ml; TLR2 SNP carriers: 176.4[110.5 to 242.3]pg/ml). Compared to non-carriers, TLR4 SNP carriers showed significant lower serum IL-8, IL-10 and GM-CSF peaks ((mean[95% confidence intervals]): IL-8: non-carriers: 42.6[36.7 to 48.5]pg/ml, TLR4 SNP carriers: 23.7[10.7 to 36.8]pg/ml; IL-10: non-carriers: 83.8[70.3 to 97.4]pg/ml, TLR4 SNP carriers: 54.2[24.1 to 84.2]pg/ml; GM-CSF: non-carriers: 33.0[27.8 to 38.3]pg/ml, TLR4 SNP carriers: 20.2[8.6 to 31.8]pg/ml). No significant changes over time or between the groups were found for the other cytokines. Conclusions: Regulation of the immunoendocrine stress response during systemic inflamma-tion is influenced by the presence of a TLR4 SNP. Cardiac surgical patients carrying this ge-notype showed decreased serum concentrations of ACTH, IL-8, IL-10 and GM-CSF. This finding might have impact on interpreting previous and designing future trials on diagnosing and modulating immunoendocrine dysregulation (e.g. adrenal insufficiency) during systemic inflammation and sepsis.