MPI für Biophysik
Refine
Year of publication
- 2023 (3) (remove)
Language
- English (3) (remove)
Has Fulltext
- yes (3)
Is part of the Bibliography
- no (3)
Institute
- MPI für Biophysik (3)
- Physik (2)
- Biochemie und Chemie (1)
- MPI für Hirnforschung (1)
Cryo-electron tomography (CryoET) resolves individual macromolecules inside living cells. However, the complex composition and high density of cells challenge the faithful identification of features in tomograms. Here, we capitalize on recent advances in electron tomography and demonstrate that 3D template matching (TM) localizes a wide range of structures inside crowded eukaryotic cells with confidence 10 to 100-fold above the noise level. We establish a TM pipeline with systematically tuned parameters for automated, objective and comprehensive feature identification. High-fidelity and high-confidence localizations of nuclear pore complexes, vaults, ribosomes, proteasomes, lipid membranes and microtubules, and individual subunits, demonstrate that TM is generic. We resolve ~100-kDa proteins, connect the functional states of complexes to their cellular localization, and capture vaults carrying ribosomal cargo in situ. By capturing individual molecular events inside living cells with defined statistical confidence, high-confidence TM greatly speeds up the CryoET workflow and sets the stage for visual proteomics.
Cryo-electron tomography (cryo-ET) is a powerful method to elucidate subcellular architecture and to structurally analyse biomolecules in situ by subtomogram averaging (STA). Specimen thickness is a key factor affecting cryo-ET data quality. Cells that are too thick for transmission imaging can be thinned by cryo-focused-ion-beam (cryo-FIB) milling. However, optimal specimen thickness for cryo-ET on lamellae has not been systematically investigated. Furthermore, the ions used to ablate material can cause damage in the lamellae, thereby reducing STA resolution. Here, we systematically benchmark the resolution depending on lamella thickness and the depth of the particles within the sample. Up to ca. 180 nm, lamella thickness does not negatively impact resolution. This shows that there is no need to generate very thin lamellae and thickness can be chosen such that it captures major cellular features. Furthermore, we show that gallium-ion-induced damage extends to depths of up to 30 nm from either lamella surface.
Ribosomes translate the genetic code into proteins. Recent technical advances have facilitated in situ structural analyses of ribosome functional states inside eukaryotic cells and the minimal bacterium Mycoplasma. However, such analyses of Gram-negative bacteria are lacking, despite their ribosomes being major antimicrobial drug targets. Here we compare two E. coli strains, a lab E. coli K-12 and human gut isolate E. coli ED1a, for which tetracycline exhibits bacteriostatic and bactericidal action, respectively. The in situ ribosome structures upon tetracycline treatment show a virtually identical drug binding-site in both strains, yet the distribution of ribosomal complexes clearly differs. While K-12 retains ribosomes in a translation competent state, tRNAs are lost in the vast majority of ED1a ribosomes. A differential response is also reflected in proteome-wide abundance and thermal stability assessment. Our study underlines the need to include molecular analyses and to consider gut bacteria when addressing antibiotic mode of action.