Buchmann Institut für Molekulare Lebenswissenschaften (BMLS)
Refine
Document Type
- Article (6) (remove)
Language
- English (6)
Has Fulltext
- yes (6)
Is part of the Bibliography
- no (6)
Keywords
Cryo-electron tomography provides a snapshot of the cellular proteome. With template matching, the spatial positions of various macromolecular complexes within their native cellular context can be detected. However, the growing awareness of the reference bias introduced by the cross-correlation based approaches, and more importantly the lack of a reliable confidence measurement in the selection of these macromolecular complexes, has restricted the use of these applications. Here we propose a heuristic, in which the reference bias is measured in real space in an analogous way to the R-free value in X-ray crystallography. We measure the reference bias within the mask used to outline the area of the template, and do not modify the template itself. The heuristic works by splitting the mask into a working and a testing area in a volume ratio of 9:1. While the working area is used during the calculation of the cross-correlation function, the information from both areas is explored to calculate the M-free score. We show using artificial data, that the M-free score gives a reliable measure for the reference bias. The heuristic can be applied in template matching and in sub-tomogram averaging. We further test the applicability of the heuristic in tomograms of purified macromolecules, and tomograms of whole Mycoplasma cells.
A key event in cellular physiology is the decision between membrane biogenesis and fat storage. Phosphatidic acid (PA) is an important intermediate at the branch point of these pathways and is continuously monitored by the transcriptional repressor Opi1 to orchestrate lipid metabolism. In this study, we report on the mechanism of membrane recognition by Opi1 and identify an amphipathic helix (AH) for selective binding of PA over phosphatidylserine (PS). The insertion of the AH into the membrane core renders Opi1 sensitive to the lipid acyl chain composition and provides a means to adjust membrane biogenesis. By rational design of the AH, we tune the membrane-binding properties of Opi1 and control its responsiveness in vivo. Using extensive molecular dynamics simulations, we identify two PA-selective three-finger grips that tightly bind the PA phosphate headgroup while interacting less intimately with PS. This work establishes lipid headgroup selectivity as a new feature in the family of AH-containing membrane property sensors.
The direct study of transcription or DNA–protein-binding events, requires imaging of individual genes at molecular resolution. Electron microscopy (EM) can show local detail of the genome. However, direct visualization and analysis of specific individual genes is currently not feasible as they cannot be unambiguously localized in the crowded, landmark-free environment of the nucleus. Here, we present a method for the genomic insertion of gene clusters that can be localized and imaged together with their associated protein complexes in the EM. The method uses CRISPR/Cas9 technology to incorporate several genes of interest near the 35S rRNA gene, which is a frequently occurring, easy-to-identify genomic locus within the nucleolus that can be used as a landmark in micrographs. As a proof of principle, we demonstrate the incorporation of the locus-native gene RDN5 and the locus-foreign gene HSX1. This led to a greater than 7-fold enrichment of RNA polymerase III (Pol III) complexes associated with the genes within the field of view, allowing for a significant increase in the analysis yield. This method thereby allows for the insertion and direct visualization of gene clusters for a range of analyses, such as changes in gene activity upon alteration of cellular or external factors.
Upon antibiotic stress Gram-negative pathogens deploy resistance-nodulation-cell division-type tripartite efflux pumps. These include a H+/drug antiporter module that recognizes structurally diverse substances, including antibiotics. Here, we show the 3.5 Å structure of subunit AdeB from the Acinetobacter baumannii AdeABC efflux pump solved by single-particle cryo-electron microscopy. The AdeB trimer adopts mainly a resting state with all protomers in a conformation devoid of transport channels or antibiotic binding sites. However, 10% of the protomers adopt a state where three transport channels lead to the closed substrate (deep) binding pocket. A comparison between drug binding of AdeB and Escherichia coli AcrB is made via activity analysis of 20 AdeB variants, selected on basis of side chain interactions with antibiotics observed in the AcrB periplasmic domain X-ray co-structures with fusidic acid (2.3 Å), doxycycline (2.1 Å) and levofloxacin (2.7 Å). AdeABC, compared to AcrAB-TolC, confers higher resistance to E. coli towards polyaromatic compounds and lower resistance towards antibiotic compounds.
Cryo-electron tomography is the only technique that can provide sub-nanometer resolved images of cell regions or even whole cells, without the need of labeling or staining methods. Technological advances over the past decade in electron microscope stability, cameras, stage precision and software have resulted in faster acquisition speeds and considerably improved resolution. In pursuit of even better image resolution, researchers seek to reduce noise – a crucial factor affecting the reliability of the tomogram interpretation and ultimately limiting the achieved resolution. Sub-tomogram averaging is the method of choice for reducing noise in repetitive objects. However, when averaging is not applicable, a trade-off between reducing noise and conserving genuine image details must be achieved. Thus, denoising is an important process that improves the interpretability of the tomogram not only directly but also by facilitating other downstream tasks, such as segmentation and 3D visualization. Here, I review contemporary denoising techniques for cryo-electron tomography by taking into account noise-specific properties of both reconstruction and detector noise. The outcomes of different techniques are compared, in order to help researchers select the most appropriate for each dataset and to achieve better and more reliable interpretation of the tomograms.
A widespread application of 3D bioprinting in basic and translational research requires accessibility to affordable printers able to produce physiologically relevant tissue models. To facilitate the use of bioprinting as a standard technique in biology, an open-source device based on a consumer-grade 3D stereolithography apparatus (SLA) printer is developed. This SLA bioprinter can produce complex constructs that preserve cell viability and recapitulate the physiology of tissues. The detailed documentation of the modifications apported to the printer as well as a throughout performance analysis allow for a straightforward adoption of the device in other labs and its customization for specific applications. Given the low cost, several modified bioprinters could be simultaneously operated for a parallelized tissue production. To showcase the capability of the bioprinter, constructs consisting of patient-derived cholangiocarcinoma organoids encapsulated in a gelatin methacrylate (GelMA)/polyethylene glycol diacrylate (PEGDA) hydrogel are produced. A thorough characterization of different GelMA/PEGDA ratios reveals that the mechanical properties of the bioprinted tumor model can be accurately fine-tuned to mimic a specific tumor micro-environment. Immunofluorescence and gene expression analyses of tumor markers confirm that the bioprinted synthetic hydrogel provides a flexible and adequate replacement of animal-derived reconstituted extracellular matrix.