790 Freizeitgestaltung, darstellende Künste, Sport
Refine
Year of publication
- 2021 (2) (remove)
Document Type
- Article (2)
Language
- English (2)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Keywords
- coronavirus (1)
- exercise (1)
- guidelines (1)
- health (1)
- reflective tape (1)
- transducer movement (1)
- ultrasound (1)
Institute
Governments have restricted public life during the COVID-19 pandemic, inter alia closing sports facilities and gyms. As regular exercise is essential for health, this study examined the effect of pandemic-related confinements on physical activity (PA) levels. A multinational survey was performed in 14 countries. Times spent in moderate-to-vigorous physical activity (MVPA) as well as in vigorous physical activity only (VPA) were assessed using the Nordic Physical Activity Questionnaire (short form). Data were obtained for leisure and occupational PA pre- and during restrictions. Compliance with PA guidelines was calculated based on the recommendations of the World Health Organization (WHO). In total, n = 13,503 respondents (39 ± 15 years, 59% females) were surveyed. Compared to pre-restrictions, overall self-reported PA declined by 41% (MVPA) and 42.2% (VPA). Reductions were higher for occupational vs. leisure time, young and old vs. middle-aged persons, previously more active vs. less active individuals, but similar between men and women. Compared to pre-pandemic, compliance with WHO guidelines decreased from 80.9% (95% CI: 80.3–81.7) to 62.5% (95% CI: 61.6–63.3). Results suggest PA levels have substantially decreased globally during the COVID-19 pandemic. Key stakeholders should consider strategies to mitigate loss in PA in order to preserve health during the pandemic.
During dynamic ultrasound assessments, unintended transducer movement over the skin needs to be prevented as it may bias the results. The present study investigated the validity of two methods quantifying transducer motion. An ultrasound transducer was moved on a pre-specified 3 cm distance over the semitendinosus muscle of eleven adults (35.8 ± 9.8 years), stopping briefly at intervals of 0.5 cm. Transducer motion was quantified (1) measuring the 2-D displacement of the shadow produced by reflective tape (RT) attached to the skin and (2) using a marker-based, three-dimensional movement analysis system (MAS). Differences between methods were detected with Wilcoxon tests; associations were checked by means of intraclass correlation coefficients (ICC 3.1) and Bland–Altman plots. Values for RT (r = 0.57, p < 0.001) and MAS (r = 0.19, p = 0.002) were significantly higher than true distances (TD). Strong correlations were found between RT and TD (ICC: 0.98, p < 0.001), MAS and TD (ICC: 0.95, p < 0.001), and MAS and RT (ICC: 0.97, p < 0.001). Bland–Altman plots showed narrow limits of agreement for both RT (−0.49 to 0.13 cm) and MAS (−0.49 to 0.34 cm) versus TD. RT and MAS are valid methods to quantify US transducer movement. In view of its low costs and complexity, RT can particularly be recommended for application in research and clinical practice. View Full-Text
Keywords: ultrasound; reflective tape; transducer movement