The HITRAP linear decelerator currently being set up at GSI will provide slow, few keV/u highly charged ions for atomic physics experiments. The expected beam intensity is up to 105 ions per shot. To optimize phase and amplitude of the RF systems intensity, bunch length and kinetic energy of the particles need to be monitored. The bunch length that we need to fit is about 2 ns, which is typically measured by capacitive pickups. However, they do not work for the low beam intensities that we face. We investigated the bunch length with a fast CVD diamond detector working in single particle counting mode. Averaging over 8 shots yields a clear, regular picture of the bunched beam. Energy measurements by capacitive pickups are limited by the presence of intense primary and partially decelerated beam and hence make tuning of the IH-structure impossible. The energy of the decelerated fraction of the beam behind the first deceleration cavity was determined to about 10 % accuracy with a permanent dipole magnet combined with a MCP. Better detector calibration should help reaching the required 1%. Design of the detectors as well as the results of the measurements will be presented.
A test stand for optical beam tomography was developed. As a new non-destructive beam-diagnostic system for high current ion beams, the test stand will be installed in the low energy beam transport section (LEBT) of the Frankfurt Neutron Source (FRANZ) behind the chopper system. The test stand consists of a rotatable vacuum chamber with a mounted CCD camera. The maximum rotation angle amounts to 270°. In a first phase the optical beam profile measurement and 3D density reconstruction is tested with a time independent 10 keV He beam. The measurements and performance of data processing algorithms are compared with the beam transport simulations. In a later phase the performance with time dependent beams (120 keV, 200 mA) at a repetition rate of 250 kHz and a duty cycle of 2.5% has to be evaluated. An overview of the first phase results is shown.
Space charge lenses use a confined electron cloud for the focusing of ion beams. The focusing strength is given by the electron density whereas the density distribution influences the mapping quality of the space charge lens and is related to the confinement. The plasma parameters, loss as well as production mechanisms have a strong impact on plasma beam interactions. A scaled up space charge lens was constructed to investigate the properties of a nonneutral plasmas in detail. New non-interceptive diagnostic has been developed to characterize the collective behaviour of the confined nonneutral plasma in terms of an optimized lens design and parameters. Experimental results will be presented in comparison with numerical simulations.
A non-interceptive optical diagnostic system on the basis of beam tomography, was developed for the planned Frankfurt Neutron Source (FRANZ). The proton driver linac of FRANZ will provide energies up to 2.0 MeV. The measurement device will non-interceptively derive required beam parameters at the end of the LEBT at beam energies of 120 keV and a current of 200 mA. On a narrow space of 351.2 mm length a rotatable tomography tank will perform a multi-turn tomography with a high and stable vacuum pressure. The tank allows to plug different measurement equipment additionally to the CCD Camera installed, to perform optical beam tomography. A collection of developed algorithms provides information about the density distribution, shape, size, location and emittance on the basis of CCD images. Simulated, as well as measured data have been applied to the evaluation algorithms to test the reliability of the beam. The actual contribution gives an overview on the current diagnostic possibilities of this diagnostic system.
Intense ion beams with small phase space occupation (high brilliance) are mandatory to keep beam losses low in high current injector accelerators like those planned for FAIR. The low energy beam transport from the ion source towards the linac has to keep the emittance growth low and has to support the optimization of the ion source tune. The Frankfurt Neutron Source Facility FRANZ is currently under construction. An intense beam of protons (2 MeV, 200 mA) will be used for neutron production using the Li7(p,n)Be7 reaction for studies of the astrophysical s-process. A collimation channel, which can be adjusted to allow the transport of beams with a certain beam emittance, is an ideal tool to optimize the ion source tune in terms of beam brightness. Therefore a collimation channel in the Low Energy Beam Transport section will be used. Through defined apertures and transversal phase space rotation using focusing solenoids the beam halo as well as unwanted H2+ and H3+ fractions will be cut. Theoretical studies which were carried out so far and a first design of the setup will be presented.
Beam test of the direct plasma injection scheme (DPIS) is carried out successfully for the first time in China, by setting up a comprehensive test and research platform of RFQ and laser ion source. The C6+ beam is accelerated successfully, and the peak beam current reaches more than 6mA which is measured by a Faraday cup of unique structure. The RF power coupled into the RFQ cavity is also examined, and results reveal that it is the RF power of about 195kW that can produce the peak beam current.
A CW RFQ prototype
(2011)
A short RFQ prototype was built for RF-tests of high power RFQ structures. We will study thermal effects and determine critical points of the design. HF-simulations with CST Microwave Studio and measurements were done. The cw-tests with 20 kW/m RF-power and simulations of thermal effects with ALGOR were finished successfully. The optimization of some details of the HF design is on focus now. First results and the status of the project will be presented.
Beam measurements with the new RFQ beam matching section at the Frankfurt Funneling Experiment
(2011)
Funneling is a method to increase low energy beam currents in multiple stages. The Frankfurt Funneling Experiment is a model of such a stage. The experiment is built up of two ion sources with electrostatic lens systems, a Two-Beam-RFQ accelerator, a funneling deflector and a beam diagnostic system. The two beams are bunched and accelerated in a Two-Beam RFQ. A funneling deflector combines the bunches to a common beam axis. A new beam transport system between RFQ accelerator and deflector has been constructed and mounted. With these extended RFQ-electrodes the drift between the Two-Beam-RFQ and the rf-deflector will be minimized and therefore unwanted emittance growth reduced. After first rf measurements current work are beam tests with the improved Two-Beam-RFQ. First results will be presented.
Usually 4-ROD Radio Frequency Quadrupoles (RFQ) are built for frequencies up to 216 MHz. For higher frequencies 4-VANE structures are more common. The advantages of 4-Rod structures, the greater flexibility for tuning and being more comfortable for maintenance, are motivating the development of a 4-Rod RFQ for higher frequencies than 216 MHz. In particular a 325 MHz RFQ with an output energy of 3 MeV is needed for the proton linac for the FAIR project of GSI. This paper reports about the design studies and the latest developments of this RFQ.
For the injector upgrade at FNAL a 4-rod Radio Frequency Quadrupole (RFQ) with a resonance frequency of 200 MHz has been build. With this short structure of only 1.3 m a very compact injector design has been realized. Simulations with CST Microwave Studio® were performed for the design. Their results leading to the RF characterizations of the RFQ and the final RF setup which has been accomplished at IAP of the Goethe-University Frankfurt are presented in this paper.