Refine
Year of publication
- 2011 (22) (remove)
Document Type
- Conference Proceeding (22) (remove)
Language
- English (22)
Has Fulltext
- yes (22)
Is part of the Bibliography
- no (22) (remove)
Institute
- Physik (22)
The HITRAP linear decelerator currently being set up at GSI will provide slow, few keV/u highly charged ions for atomic physics experiments. The expected beam intensity is up to 105 ions per shot. To optimize phase and amplitude of the RF systems intensity, bunch length and kinetic energy of the particles need to be monitored. The bunch length that we need to fit is about 2 ns, which is typically measured by capacitive pickups. However, they do not work for the low beam intensities that we face. We investigated the bunch length with a fast CVD diamond detector working in single particle counting mode. Averaging over 8 shots yields a clear, regular picture of the bunched beam. Energy measurements by capacitive pickups are limited by the presence of intense primary and partially decelerated beam and hence make tuning of the IH-structure impossible. The energy of the decelerated fraction of the beam behind the first deceleration cavity was determined to about 10 % accuracy with a permanent dipole magnet combined with a MCP. Better detector calibration should help reaching the required 1%. Design of the detectors as well as the results of the measurements will be presented.
A test stand for optical beam tomography was developed. As a new non-destructive beam-diagnostic system for high current ion beams, the test stand will be installed in the low energy beam transport section (LEBT) of the Frankfurt Neutron Source (FRANZ) behind the chopper system. The test stand consists of a rotatable vacuum chamber with a mounted CCD camera. The maximum rotation angle amounts to 270°. In a first phase the optical beam profile measurement and 3D density reconstruction is tested with a time independent 10 keV He beam. The measurements and performance of data processing algorithms are compared with the beam transport simulations. In a later phase the performance with time dependent beams (120 keV, 200 mA) at a repetition rate of 250 kHz and a duty cycle of 2.5% has to be evaluated. An overview of the first phase results is shown.
Space charge lenses use a confined electron cloud for the focusing of ion beams. The focusing strength is given by the electron density whereas the density distribution influences the mapping quality of the space charge lens and is related to the confinement. The plasma parameters, loss as well as production mechanisms have a strong impact on plasma beam interactions. A scaled up space charge lens was constructed to investigate the properties of a nonneutral plasmas in detail. New non-interceptive diagnostic has been developed to characterize the collective behaviour of the confined nonneutral plasma in terms of an optimized lens design and parameters. Experimental results will be presented in comparison with numerical simulations.
A non-interceptive optical diagnostic system on the basis of beam tomography, was developed for the planned Frankfurt Neutron Source (FRANZ). The proton driver linac of FRANZ will provide energies up to 2.0 MeV. The measurement device will non-interceptively derive required beam parameters at the end of the LEBT at beam energies of 120 keV and a current of 200 mA. On a narrow space of 351.2 mm length a rotatable tomography tank will perform a multi-turn tomography with a high and stable vacuum pressure. The tank allows to plug different measurement equipment additionally to the CCD Camera installed, to perform optical beam tomography. A collection of developed algorithms provides information about the density distribution, shape, size, location and emittance on the basis of CCD images. Simulated, as well as measured data have been applied to the evaluation algorithms to test the reliability of the beam. The actual contribution gives an overview on the current diagnostic possibilities of this diagnostic system.
Space charge lenses using a stable electron cloud for focusing low energy heavy ion beams are an alternative concept to conventional ion optics. Due to external fields electrons are confined inside the lens’ volume. In case of a homogeneously distributed electron cloud the linear electric space charge field enables beam focusing free of aberration. Since the mapping quality of the lens is related to the confinement, non-destructive diagnostics has been developed to determine the plasma parameters and to characterize the collective behavior of the confined nonneutral plasma. Moreover, a scaled up space charge lens was constructed for a detailed investigation of the nonneutral plasma properties as well as beam interactions with a stable confined electron cloud. Experimental results will be presented in comparison with numerical simulations.
As the successor of the EUROTRANS project, the MAX project is aiming to continue the R&D effects for a European Accelerator-Driven System and to bring the conceptual design to reality. The layout of the driver linac for MAX will follow the reference design made for the XT-ADS phase of the EUROTRANS project. For the injector part, new design strategies and approaches, e.g. half resonant frequency, half transition-energy between the RFQ and the CH-DTL, and using the 4-rod RFQ structure instead of the originally proposed 4-vane RFQ, have been conceived and studied to reach a more reliable CW operation at reduced costs. In this paper, the design and simulation results of the MAX injector are presented.
MYRRHA is conceived as an accelerator driven system (ADS) for transmutation of high level nuclear waste. The neutron source is created by coupling a proton accelerator of 600 MeV with a 4 mA proton beam, a spallation source and a sub-critical core. The IAP of Frankfurt University is responsible for the development of the 17 MeV injector operated at 176 MHz. The injector consists of a 1.5 MeV 4-Rod-RFQ and six CH-drifttube-structures. The first two CH-structures will be operated at room temperature and the other CH-structures are superconducting cavities assembled in one cryo-module. To achieve the extremely high reliability required by the ADS application, the design of the 17 MeV injector has been intensively studied, with respect to thermal issues, minimum peak fields and field distribution.
Chromatic, geometric and space charge effects on laser accelerated protons focused by a solenoid
(2011)
We studied numerically emittance and transmission effects by chromatic and geometric aberrations, with and without space charge, for a proton beam behind a solenoid in the laser proton experiment LIGHT at GSI. The TraceWin code was employed using a field map for the solenoid and an initial distribution with exponential energy dependence close to the experiment. The results show a strong effect of chromatic, and a relatively weak one of geometric aberrations as well as dependence of proton transmission on distance from the solenoid. The chromatic effect has an energy filtering property due to the finite radius beam pipe. Furthermore, a relatively modest dependence of transmission on space charge is found for p production intensity below 1011.
Experimental results and theoretical predictions in laser acceleration of protons achieved energies of ten to several tens of MeV. The LIGHT project (Laser Ion Generation, Handling and Transport) is proposed to use the PHELIX laser accelerated protons and to provide transport, focusing and injection into a conventional accelerator. This study demonstrates transport and focusing of laser-accelerated 10 MeV protons by a pulsed 18 T magnetic solenoid. The effect of co-moving electrons on the beam dynamics is investigated. The unique features of the proton distribution like small emittances and high yield of the order of 1013 protons per shot open new research area. The possibility of creating laser based injectors for ion accelerators is addressed. With respect to transit energies, direct matching into DTL's seems adequate. The bunch injection into a proposed CH− structure is under investigation at IAP Frankfurt. Options and simulation tools are presented.
An optimized design of a stellarator-type storage ring for low energy ion beams was numerically investigated. The magnetic field variation along the circumference and therefore magnetic heating is suppressed by using simple circular correction coils. Particle-in-Cell (PIC) simulations in a magnetic flux coordinate system show the ability of high current ion beam accumulation in such a configuration with unique features for clockwise and anticlockwise moving beams. Additionally scaled down experiments with two 30 degree room temperature toroidal segments were performed to demonstrate toroidal transport and to develop optical beam diagnostics. Properties of multi-component beams, redistribution of transversal momenta in the non-adiabatic part of the experimental configuration and investigation of strongly confined beam induced electron clouds will be addressed.