Refine
Year of publication
- 2011 (42) (remove)
Document Type
- Conference Proceeding (42) (remove)
Language
- English (42)
Has Fulltext
- yes (42)
Is part of the Bibliography
- no (42)
Institute
- Physik (42) (remove)
The LANSCE linear accelerator at Los Alamos National Laboratory provides H− and H+ beams to several user facilities that support Isotope Production, NNSA Stockpile Stewardship, and Basic Energy Science programs. These beams are initially accelerated to 750 keV using Cockcroft-Walton (CW) based injectors that have been in operation for over 37 years. They have failure modes which can result in prolonged operational downtime due to the unavailability of replacement parts. To reduce long-term operational risks and to realize future beam performance goals in support of the Materials Test Station (MTS) and the Matter-Radiation Interactions in Extremes (MaRIE) Facility, plans are underway to develop a Radio-Frequency Quadrupole (RFQ) based front end as a modern injector replacement for the existing CW injectors. Our progress to date will be discussed.
n order to reach the desired intensities of heavy ion beams for the experiments at FAIR, SIS18 and SIS100 have to be operated with intermediate charge states. Operation with intermediate charge state heavy ions at the intensity level of about 1011 ions per cycle has never been demonstrated elsewhere and requires a dedicated upgrade program for SIS18 and a dedicated machine design for SIS100. The specific problems coming along with the intermediate charge state operation in terms of charge exchange processes at collisions with residual gas atoms, pressure bumps by ion induced desorption and corresponding beam loss appears far below the typical space charge limits. Thus, new design concepts and new technical equipment addressing these issues are developed and realized with highest priority. The upgrade program of SIS18 addressing the goal of minimum ionization beam loss and stable residual gas pressure conditions has been defined in 2005. A major part of this upgrade program has been successfully realized, with the result of a world record in accelerated number of intermediate charge state heavy ions.
Accelerator Driven Systems (ADS) are promising tools for the efficient transmutation of nuclear waste products in dedicated industrial installations, called transmuters. The Myrrha project at Mol, Belgium, placed itself on the path towards these applications with a multipurpose and versatile system based on a liquid PbBi (LBE) cooled fast reactor (80 MWth) which may be operated in both critical and subcritical modes. In the latter case the core is fed by spallation neutrons obtained from a 600 MeV proton beam hitting the LBE coolant/target. The accelerator providing this beam is a high intensity CW superconducting linac which is laid out for the highest achievable reliability. The combination of a parallel redundant and of a fault tolerant scheme should allow obtaining an MTBF value in excess of 250 hours that is required for optimal integrity and successful operation of the ADS. Myrrha is expected to be operational in 2023. The forthcoming 4-year period is fully dedicated to R&D activities, and in the field of the accelerator they are strongly focused on the reliability aspects and on the proper shaping of the beam trip spectrum.
Development of fragmented low-Z ion beams for the NA61 fixed-target experiment at the CERN SPS
(2011)
The NA61 experiment, aims to study the properties of the onset of deconfinement at low SPS energies and to find signatures of the critical point of strongly interacting matter. A broad range in T-μB phase diagram will be covered by performing an energy (13A-158A GeV/c) and system size (p+p, Be+Be, Ar+Ca, Xe+La) scan. In a first phase, fragmented ion beams of 7Be or 11C produced as secondaries with the same momentum per nucleon when the incident primary Pb-ion beam hits a thin Be target will be used. The H2 beam line that transports the beam to the experiment acts as a double spectrometer which combined with a new thin target (degrader) where fragments loose energy proportional to the square of their charge allows the separation of the wanted A/Z fragments. Thin scintillators and TOF measurement for the low energy points are used as particle identification devices. In this paper results from the first test of the fragmented ion beam done in 2010 will be presented showing that a pure Be beam can be obtained satisfying the needs of the experiment.
Space charge lenses using a stable electron cloud for focusing low energy heavy ion beams are an alternative concept to conventional ion optics. Due to external fields electrons are confined inside the lens’ volume. In case of a homogeneously distributed electron cloud the linear electric space charge field enables beam focusing free of aberration. Since the mapping quality of the lens is related to the confinement, non-destructive diagnostics has been developed to determine the plasma parameters and to characterize the collective behavior of the confined nonneutral plasma. Moreover, a scaled up space charge lens was constructed for a detailed investigation of the nonneutral plasma properties as well as beam interactions with a stable confined electron cloud. Experimental results will be presented in comparison with numerical simulations.
As the successor of the EUROTRANS project, the MAX project is aiming to continue the R&D effects for a European Accelerator-Driven System and to bring the conceptual design to reality. The layout of the driver linac for MAX will follow the reference design made for the XT-ADS phase of the EUROTRANS project. For the injector part, new design strategies and approaches, e.g. half resonant frequency, half transition-energy between the RFQ and the CH-DTL, and using the 4-rod RFQ structure instead of the originally proposed 4-vane RFQ, have been conceived and studied to reach a more reliable CW operation at reduced costs. In this paper, the design and simulation results of the MAX injector are presented.
MYRRHA is conceived as an accelerator driven system (ADS) for transmutation of high level nuclear waste. The neutron source is created by coupling a proton accelerator of 600 MeV with a 4 mA proton beam, a spallation source and a sub-critical core. The IAP of Frankfurt University is responsible for the development of the 17 MeV injector operated at 176 MHz. The injector consists of a 1.5 MeV 4-Rod-RFQ and six CH-drifttube-structures. The first two CH-structures will be operated at room temperature and the other CH-structures are superconducting cavities assembled in one cryo-module. To achieve the extremely high reliability required by the ADS application, the design of the 17 MeV injector has been intensively studied, with respect to thermal issues, minimum peak fields and field distribution.
Chromatic, geometric and space charge effects on laser accelerated protons focused by a solenoid
(2011)
We studied numerically emittance and transmission effects by chromatic and geometric aberrations, with and without space charge, for a proton beam behind a solenoid in the laser proton experiment LIGHT at GSI. The TraceWin code was employed using a field map for the solenoid and an initial distribution with exponential energy dependence close to the experiment. The results show a strong effect of chromatic, and a relatively weak one of geometric aberrations as well as dependence of proton transmission on distance from the solenoid. The chromatic effect has an energy filtering property due to the finite radius beam pipe. Furthermore, a relatively modest dependence of transmission on space charge is found for p production intensity below 1011.
Experimental results and theoretical predictions in laser acceleration of protons achieved energies of ten to several tens of MeV. The LIGHT project (Laser Ion Generation, Handling and Transport) is proposed to use the PHELIX laser accelerated protons and to provide transport, focusing and injection into a conventional accelerator. This study demonstrates transport and focusing of laser-accelerated 10 MeV protons by a pulsed 18 T magnetic solenoid. The effect of co-moving electrons on the beam dynamics is investigated. The unique features of the proton distribution like small emittances and high yield of the order of 1013 protons per shot open new research area. The possibility of creating laser based injectors for ion accelerators is addressed. With respect to transit energies, direct matching into DTL's seems adequate. The bunch injection into a proposed CH− structure is under investigation at IAP Frankfurt. Options and simulation tools are presented.
An optimized design of a stellarator-type storage ring for low energy ion beams was numerically investigated. The magnetic field variation along the circumference and therefore magnetic heating is suppressed by using simple circular correction coils. Particle-in-Cell (PIC) simulations in a magnetic flux coordinate system show the ability of high current ion beam accumulation in such a configuration with unique features for clockwise and anticlockwise moving beams. Additionally scaled down experiments with two 30 degree room temperature toroidal segments were performed to demonstrate toroidal transport and to develop optical beam diagnostics. Properties of multi-component beams, redistribution of transversal momenta in the non-adiabatic part of the experimental configuration and investigation of strongly confined beam induced electron clouds will be addressed.