Refine
Year of publication
- 2023 (327) (remove)
Document Type
- Preprint (170)
- Article (102)
- Doctoral Thesis (30)
- Conference Proceeding (12)
- Contribution to a Periodical (9)
- Book (3)
- Bachelor Thesis (1)
Has Fulltext
- yes (327)
Is part of the Bibliography
- no (327)
Keywords
Institute
- Physik (327) (remove)
The interaction between Λ baryons and kaons/antikaons is a crucial ingredient for the strangeness S=0 and S=−2 sector of the meson–baryon interaction at low energies. In particular, the ΛK‾ might help in understanding the origin of states such as the Ξ(1620), whose nature and properties are still under debate. Experimental data on Λ–K and Λ–K‾ systems are scarce, leading to large uncertainties and tension between the available theoretical predictions constrained by such data. In this Letter we present the measurements of Λ–K⊕+Λ‾–K− and Λ–K⊕−Λ‾–K+ correlations obtained in the high-multiplicity triggered data sample in pp collisions at s=13 TeV recorded by ALICE at the LHC. The correlation function for both pairs is modeled using the Lednický–Lyuboshits analytical formula and the corresponding scattering parameters are extracted. The Λ–K⊕−Λ‾–K+ correlations show the presence of several structures at relative momenta k⁎ above 200 MeV/c, compatible with the Ω baryon, the Ξ(1690), and Ξ(1820) resonances decaying into Λ–K− pairs. The low k⁎ region in the Λ–K⊕−Λ‾–K+ also exhibits the presence of the Ξ(1620) state, expected to strongly couple to the measured pair. The presented data allow to access the ΛK+ and ΛK− strong interaction with an unprecedented precision and deliver the first experimental observation of the Ξ(1620) decaying into ΛK−.
Quarkyonic or baryquark matter? On the dynamical generation of momentum space shell structure
(2023)
We study the equation of state of a mixture of (quasi-)free constituent quarks and nucleons with hard-core repulsion at zero temperature. Two opposite scenarios for the realization of the Pauli exclusion principle are considered: (i) a Fermi sea of quarks surrounded by a shell of baryons – the quarkyonic matter, and (ii) a Fermi sea of nucleons surrounded by a shell of quarks which we call baryquark matter. In both scenarios, the sizes of the Fermi sea and shell are fixed through energy minimization at fixed baryon number density. While both cases yield a qualitatively similar transition from hadronic to quark matter, we find that baryquark matter is energetically favored in this setup and yields a physically acceptable behavior of the speed of sound without the need to introduce an infrared regulator. In order to retain the theoretically more appealing quarkyonic matter as the preferred form of dense QCD matter will thus require modifications to the existing dynamical generation mechanisms, such as, for example, the introduction of momentum-dependent nuclear interactions.
Cryo-electron tomography (CryoET) resolves individual macromolecules inside living cells. However, the complex composition and high density of cells challenge the faithful identification of features in tomograms. Here, we capitalize on recent advances in electron tomography and demonstrate that 3D template matching (TM) localizes a wide range of structures inside crowded eukaryotic cells with confidence 10 to 100-fold above the noise level. We establish a TM pipeline with systematically tuned parameters for automated, objective and comprehensive feature identification. High-fidelity and high-confidence localizations of nuclear pore complexes, vaults, ribosomes, proteasomes, lipid membranes and microtubules, and individual subunits, demonstrate that TM is generic. We resolve ~100-kDa proteins, connect the functional states of complexes to their cellular localization, and capture vaults carrying ribosomal cargo in situ. By capturing individual molecular events inside living cells with defined statistical confidence, high-confidence TM greatly speeds up the CryoET workflow and sets the stage for visual proteomics.
Proton-powered c-ring rotation in mitochondrial ATP synthase is crucial to convert the transmembrane protonmotive force into torque to drive the synthesis of ATP. Capitalizing on recent cryo-EM structures, we aim at a structural and energetic understanding of how functional directional rotation is achieved. We performed multi-microsecond atomistic simulations to determine the free energy profiles along the c-ring rotation angle before and after the arrival of a new proton. Our results reveal that rotation proceeds by dynamic sliding of the ring over the a-subunit surface, during which interactions with conserved polar residues stabilize distinct intermediates. Ordered water chains line up for a Grotthuss-type proton transfer in one of these intermediates. After proton transfer, a high barrier prevents backward rotation and an overall drop in free energy favors forward rotation, ensuring the directionality of c-ring rotation required for the thermodynamically disfavored ATP synthesis. The essential arginine of the a-subunit stabilizes the rotated configuration through a salt-bridge with the c-ring. Overall, we describe a complete mechanism for the rotation step of the ATP synthase rotor, thereby illuminating a process critical to all life at atomic resolution.
Proton-powered c-ring rotation in mitochondrial ATP synthase is crucial to convert the transmembrane protonmotive force into torque to drive the synthesis of ATP. Capitalizing on recent cryo-EM structures, we aim at a structural and energetic understanding of how functional directional rotation is achieved. We performed multi-microsecond atomistic simulations to determine the free energy profiles along the c-ring rotation angle before and after the arrival of a new proton. Our results reveal that rotation proceeds by dynamic sliding of the ring over the a-subunit surface, during which interactions with conserved polar residues stabilize distinct intermediates. Ordered water chains line up for a Grotthuss-type proton transfer in one of these intermediates. After proton transfer, a high barrier prevents backward rotation and an overall drop in free energy favors forward rotation, ensuring the directionality of c-ring rotation required for the thermodynamically disfavored ATP synthesis. The essential arginine of the a-subunit stabilizes the rotated configuration through a salt-bridge with the c-ring. Overall, we describe a complete mechanism for the rotation step of the ATP synthase rotor, thereby illuminating a process critical to all life at atomic resolution.
Precise tune determination and split beam emittance reconstruction at the CERN PS synchrotron
(2023)
In accelerator physics, the need to improve the performance and better control the operating point of an accelerator has become, year after year, an increasingly important need in order to achieve higher energies and brightness, as well as point-like particle beams. If this involves increasingly advanced technological developments (in terms, for example, of materials for more intense superconducting magnets), it can not take place in the absence of targeted studies of linear and non-linear beam dynamics. In the context of this Ph.D. thesis in physics, linear and non-linear dynamics of charged particles in circular accelerators is the topic that will be discussed and treated in detail. In particular, the presentation and discussion of the results will be divided in two main topics: the need to know the physical properties of a proton beam; and the development of innovative methods to determine and study the accelerator’s working point. With regard to the first topic, an innovative procedure will be presented to determine the transverse size of the PS beam in the beam extraction phase. Among the different ways the extraction occurs at the PS, the analysed one is based on the transverse splitting of the beam by means of non-linear fields. Thus, the knowledge of the transverse beam size is not trivial since resonant linear and non-linear beam structures (namely, core and islands) arise and, for each of them, the beam size has to be quantified. This parameter is crucial for two main reasons: the accelerator that will receive the beam exiting the upstream accelerator may have restrictions (physical or magnetic) that involve a partial or total loss of the incoming beam; and any experiments located downstream of the considered accelerator may need a beam with a transversal size as constant as possible; consequently, its monitoring and control are essential. The second topic concerns the accurate determination of the working point of an accelerator, defined as the number of transverse oscillations the particle beam travels per unit of accelerator circumference, both horizontally and vertically. This quantity is called horizontal and vertical tune, respectively. Their knowledge is also crucial to understand whether the beam will be stable or unstable. In fact, not all tune values are acceptable, as there are particular values that bring the beam into resonance. In this configuration, the amplitude of the transverse oscillations of the particles increases in an uncontrolled manner and leads to the loss of all or part of the beam. Note that, in particular operating conditions, the resonant conditions are sought and desired to model, in a suitable way, the transversal shape of the beam, such as the above mentioned PS extraction scheme. It is even clearer how much the determination of the machine working point is essential to determine the operating conditions of an accelerator. In this context, several methods (also taken from the field of applied mathematics) to calculate the tune will be demonstrated and tested numerically on different types of synthetic signals. At the end of this description, the use of experimental data will allow to obtain the benchmark of a new method for the direct calculation of some characteristic quantities of non-linear beam dynamics (namely, the amplitude detuning, i.e. the variation of tune as a function of intensity of the perturbation provided to the beam.
Cryo-electron tomography (cryo-ET) is a powerful method to elucidate subcellular architecture and to structurally analyse biomolecules in situ by subtomogram averaging (STA). Specimen thickness is a key factor affecting cryo-ET data quality. Cells that are too thick for transmission imaging can be thinned by cryo-focused-ion-beam (cryo-FIB) milling. However, optimal specimen thickness for cryo-ET on lamellae has not been systematically investigated. Furthermore, the ions used to ablate material can cause damage in the lamellae, thereby reducing STA resolution. Here, we systematically benchmark the resolution depending on lamella thickness and the depth of the particles within the sample. Up to ca. 180 nm, lamella thickness does not negatively impact resolution. This shows that there is no need to generate very thin lamellae and thickness can be chosen such that it captures major cellular features. Furthermore, we show that gallium-ion-induced damage extends to depths of up to 30 nm from either lamella surface.
Precise intensity monitoring at CRYRING@ESR: on designing a Cryogenic Current Comparator for FAIR
(2023)
In the field of today’s beam intensity diagnostic there is a significant gap in the non-interceptive, calibrated measurement of the absolute intensity of continuous (unbunched) dc beams with current amplitudes below 1 μA. At the Facility for Antiproton and Ion Research (FAIR) low-intensity DC beams will occur during slow extraction from the synchrotrons as well as for coasting beams of highly-charged or exotic nuclei in the storage rings. The lack of adequate beam instrumentation limits the experimental program as well as the accuracy of experimental results.
The Cryogenic Current Comparator (CCC) can close the diagnostic gap with a high-precision dc current reading independent of ion-species and of beam parameters. However, the established detector design based on a core with high magnetic permeability and on a radial shield geometry has well-known weaknesses concerning magnetic shielding efficiency and intrinsic current noise. To eliminate these weaknesses, a novel coreless CCC with a co-axial shield was constructed and combined with a high-performance SQUID contributed by the Leibniz-Institute of Photonic Technology (Leibniz-IPHT Jena). The new axial CCC model was compared to a radial CCC with the established design provided by the Friedrich-Schiller-University Jena. According to numerical simulations prepared at TU Darmstadt and test measurements of the detectors in the laboratory, the new design offered a significant improvement of the shielding factor – from 75dB to 207dB at the required dimensions – and eliminated all noise contributions from the core material, promising an improved current resolution. Although the lower inductance of the pickup coil reduced the coupling to the beam significantly, the noise properties of the new CCC type were comparable to the classical version with a high-permeability core. However, the expected decrease of the low-frequency noise and thus an increase of the current resolution could not be observed at this stage of development.
Consequently, the classical CCC based on the radial shielding and high-permeability core had to be installed in CRYRING@ESR to provide best possible intensity measurements for the upcoming experimental campaign. In CRYRING the CCC was operated with beam currents between 1nA and 20μA and with different ion species (H, Ne, O, Pb, U). It was shown that the CCC provides a noise-limited current resolution of better than 3.2 nArms at a bandwidth of 200 kHz as well as a noise level below 40 pA/√Hz above 1 kHz. During the operation, the main noise sources of the accelerator environment had to be identified and suitable mitigation strategies were developed. Temperature and pressure fluctuations were suppressed with a newly-designed cryogenic support system based on a 70 l helium bath cryostat, developed and built in collaboration with the Institut für Luft- und Kältetechnik Dresden, in combination with a helium re-liquefier. The cryogenic operating time was restricted to around 7 days, which must be expanded significantly in the future. Digital filters were developed to remove the perturbations of the helium liquefier and of the neighboring dipole magnets. Given the promising results the CCC system can be considered as a prototype for future CCCs at FAIR.