Refine
Year of publication
Document Type
- Doctoral Thesis (22)
- Master's Thesis (1)
Has Fulltext
- yes (23)
Is part of the Bibliography
- no (23)
Keywords
- Nukleosynthese (2)
- Activation (1)
- Beschleuniger (1)
- Chopper (1)
- Coulombdissoziation (1)
- Fluka (1)
- Gabor lens (1)
- Gammakalorimeter (1)
- Ion Beam (1)
- Kupfer-63 (1)
Institute
- Physik (23)
In der nuklearen Astrophysik sind Experimente mit hochgeladenen Radionukliden von großer Bedeutung. Diese exotischen Nuklide können in Schwerionenbeschleunigeranlagen hergestellt und in Speicherringen gespeichert werden. Momentan existieren weltweit zwei Anlagen, die solche Experimente ermöglichen: das GSI Helmholtzzentrum für Schwerionenforschung GmbH in Darmstadt und das Institut für moderne Physik (IMP) in Lanzhou, China. Da die Ausbeute dieser Nuklide gering ist, werden zerstörungsfreie Nachweismethoden in den Speicherringen verwendet. Diese machen von den Methoden der Spektralanalyse Gebrauch. Nicht nur die geringe Ausbeute, sondern auch die kurze Lebensdauer dieser Nuklide stellen hohe Anforderungen an die Sensitivität und Geschwindigkeit dieser Detektoren.
Eine übliche Methode ist die Verwendung kapazitiver Schottky-Sonden. Eine solche Sonde ist seit 1991 an der GSI im Speicherring ESR im Einsatz. Um die Empfindlichkeit zu erhöhen, kann man Mikrowellenkavitäten als resonante Pickups verwenden. Die von den Teilchen induzierten elektromagnetischen Felder können resonante Moden im Resonator anregen. Die Geometrie des Pickups und das verwendete Material spielen eine wesentliche Rolle in der Gestaltung der Feldbilder. Die resultierenden Signale, auch Schottky Signale genannt, werden mittels einer Antenne ausgekoppelt und anschliessend an einen Spektrumanalysator angeschlossen. Für die Analyse der gespeicherten Daten können verschiedene Methoden der Spektralschätzung wie z.B. das Multi-Taper angewendet werden. Nachdem eine externe Kalibrierung durchgeführt worden ist, kann das Pickup auch als ein Stromsensor verwendet werden.
Diese Arbeit befasst sich mit der Theorie, dem Aufbau und ersten Anwendungen eines neuen resonanten Pickups, das im Jahr 2010 in den Speicherring ESR eingebaut und in mehreren Experimenten erfolgreich eingesetzt wurde. Ein ähnliches Pickup wurde im Jahr 2011 in den CSRe im IMP Lanzhou eingebaut. Einzelne Schwerionen mit 400 MeV pro Nukleon wurden erfolgreich mit dem GSI-Pickup nachgewiesen. Das Pickup wird regelmässig in Speicherringexperimenten eingesetzt. Ähnliche Experimente sind für CSRe in Lanzhou geplant.
The planned Facility for Antiproton and Ion Research (FAIR) at GSI has to cope with a wide range of beam intensities in its high-energy beam transport systems and in the storage rings. To meet the requirements of a non-intercepting intensity measurement down to nA range, it is planned to install a number of Cryogenic Current Comparator (CCC) units at different locations in the FAIR beamlines. In this work, the first CCC system for intensity measurement of heavy ion beams, which was developed at GSI, was re-commissioned and upgraded to be used as a 'GSI - CCC prototype' for extensive optimization and development of an improved CCC for FAIR. After installation of a new SQUID sensor and related electronics, as well as implementation of improved data acquisition components, successful beam current measurements were performed at a SIS18 extraction line. The measured intensity values were compared with those of a Secondary Electron Monitor (SEM). Furthermore, the spill-structure of a slowly extracted beam was measured and analyzed, investigating its improvement due to bunching during the slow-extraction process. Due to the extreme sensitivity of the superconducting sensor, the determined intensity values as well as the adjustment of the system for optimal performance are strongly influenced by the numerous noise sources of the accelerators environment. For this reason, detailed studies of different effects caused by noise have been carried out, which are presented together with proposals to reduce them. Similarly, studies were performed to increase the dynamic range and overcome slew rate limitations, the results of which are illustrated and discussed as well. By combining the various optimizations and characterizations of the GSI CCC prototype with the experiences made during beam operation, criteria for a more efficient CCC System could be worked out, which are presented in this work. The details of this new design are worked out with respect to the corresponding boundary conditions at FAIR. Larger beam tube diameters, higher radiation resistivity and UHV requirements are of particular importance for the cryostat. At the same time these parameters affect the CCC superconducting magnetic shielding, which again has significant influence on the current resolution of the system. In order to investigate the influence of the geometry of the superconducting magnetic shield on different magnetic field components and to optimize the attenuation, FEM simulations have been performed. Based on the results of these calculations, modifications of the shield geometry for optimum damping behavior are proposed and discussed in the thesis.
Im Rahmen des FAIR Projektes wurde ein neuartiger Prototyp eines nicht strahlzerstörenden Bunch Struktur Monitors (BSM) am GSI UNILAC entwickelt. Ziel ist es, ein zuverlässiges Diagnosegerät zu entwickeln, welches die longitudinale Struktur der Ionenbunche innerhalb des LINACs untersuchen kann. Notwendig ist hierbei eine effektive Zeitauflösung deutlich unter 100 ps, bei möglichst wenigen Makropuls Mittelungen. Nach der erfolgreichen Inbetriebnahme soll der BSM Prototyp dazu dienen, die Umsetzbarkeit eines weiteren nichtinvasiven Geräts für den geplanten Proton-LINAC bei FAIR mit einer notwendigen Zeitauflösung von 10 ps zu beurteilen.
Die numerische Simulation von Materialien, welche dem Hochstrom-Ionenstrahl ausgesetzt sind, zeigten einen sehr hohen thermischen Stress. Daher wurde der Ansatz eines nicht strahlzerstörenden Diagnosegerätes verfolgt. Das Design beruht auf der Erzeugung von Sekundärelektronen durch Strahl-Restgas Kollisionen im Strahlrohr. Durch das Anlegen eines homogenen Hochspannungspotentials von bis zu -31 kV, wird ein Elektronenstrahl erzeugt, welcher die zeitliche Struktur des Ionenbunches trägt. Die zeitliche Information des Elektronenstrahles wird beim Durchfliegen eines HF-Ablenkers, welcher resonant an die 36 MHz des Beschleunigers gekoppelt ist, in eine räumliche Intensitätsverteilung umgewandelt. Anschließend wird die Elektronenverteilung auf einem bildgebenden MCP-Phosphor-Detektor durch eine CCD-Kamera detektiert und in die Bunch Struktur überführt.
Intensive Untersuchungen der BSM Eigenschaften ergaben eine höchste Auflösung von 37 ±6.3 ps bei gleichzeitig akzeptabler Intensität auf dem MCP-Detektor. Unter anderem wurden auch stabile Einzelschussmessungen durchgeführt, welche für die Profilmessung nur einen einzelnen Makropuls benötigten, statt über typischerweise 8-32 Pulse zu mitteln.
Durch die systematische Manipulation der Bunchlänge durch einen Rebuncher sind nicht gaußförmige Profile von 280 ps bis 650 ps detektiert worden, welche als Studie für eine Emittanzbestimmung genutzt worden sind. In Abhängigkeit des Analyseverfahrens sind Werte von εGauss = 1.42 ±0.14 keV/u ns bis εSD = 3.03 ±0.33 keV/u ns für die Emittanz bestimmt worden.
Des Weiteren ist ein Finite-Elemente Modell erstellt worden, um die Zeitstruktur der Sekundärelektronen innerhalb des elektronenoptischen Systems zu bestimmen. Für das Setup mit der höchsten Auflösung von 37 ps ergab sich eine zusätzliche Zeitverbreiterung von 5.6 ps, welche nur geringfügig die experimentell bestimmte Auflösung verschlechtert.
Der nicht strahlzerstörende BSM liefert eine ausreichend hohe zeitliche Auflösung für detailreiche Untersuchung der longitudinalen Bunchstruktur, ohne negative Einflüsse auf den Ionenstrahl auszuüben. Fortgeschrittene Messungen, wie longitudinale Emittanzbestimmung und Makropulsanalysen, sind möglich und werden dazu beitragen, die LINAC Strukturen besser zu verstehen und weiter zu optimieren.
Obwohl bei der Umsetzung des Arbeitsprinzips für den geplanten Proton-LINAC die veränderten Strahlparameter berücksichtigt werden müssen, zeigen die Ergebnisse, wie die Zeitstrukturuntersuchung und die erreichte Phasenauflösung von 0.5° bei 36 MHz, dass zeitliche Auflösungen bei Aufrechterhaltung der Phasenauflösung von bis zu 10 ps für einen neuen BSM Prototypen möglich sind.