Institutes
Refine
Document Type
- Article (11)
Language
- English (11) (remove)
Has Fulltext
- yes (11)
Is part of the Bibliography
- no (11)
Keywords
- Cochlear implant (3)
- COVID-19 (2)
- SARS-CoV-2 (2)
- speech perception (2)
- Clinical practice guidelines (1)
- Cochlear implantation (1)
- Cohort studies (1)
- Complications (1)
- Cone-beam computed tomography (1)
- Elderly (1)
Institute
- Medizin (11)
Purpose: To stratify differences in visual semantic and quantitative imaging features in intensive care patients with nonspecific mastoid effusions versus patients with acute mastoiditis (AM) requiring surgical treatment. Methods: We included 48 patients (male, 28; female, 20; mean age, 59.5 ± 18.1 years) with mastoid opacification (AM, n = 24; control, n = 24) who underwent clinically indicated cerebral CT between 12/2007 and 07/2018 in this retrospective study. Semantic features described the extend and asymmetry of mastoid and middle-ear cavity opacification and complications like erosive changes. Minimum, maximum and mean Hounsfield unit (HU) values were obtained as quantitative features. We analyzed the features employing univariate testing. Results: Compared to intensive care patients, AM patients revealed asymmetric mastoid or middle-ear cavity opacification (likelihood-ratio (LR) < 0.001). Applying a dedicated threshold of the extent of opacification, AM patients reached significance levels of LR = 0.042 and 0.002 for mastoid and middle-ear cavity opacification. AM cases showed higher maximum and mean HU values (p = 0.009, p = 0.024). Conclusions: We revealed that the extent and asymmetry of mastoid and middle-ear cavity opacification differs significantly between AM patients and intensive care patients. Multicenter research is needed to expand our cohort and possibly pave the way to build a non-invasive predictive model for AM in the future.
Objectives: To correlate the radiological assessment of the mastoid facial canal in postoperative cochlear implant (CI) cone-beam CT (CBCT) and other possible contributing clinical or implant-related factors with postoperative facial nerve stimulation (FNS) occurrence. Methods: Two experienced radiologists evaluated retrospectively 215 postoperative post-CI CBCT examinations. The mastoid facial canal diameter, wall thickness, distance between the electrode cable and mastoid facial canal, and facial-chorda tympani angle were assessed. Additionally, the intracochlear position and the insertion angle and depth of electrodes were evaluated. Clinical data were analyzed for postoperative FNS within 1.5-year follow-up, CI type, onset, and causes for hearing loss such as otosclerosis, meningitis, and history of previous ear surgeries. Postoperative FNS was correlated with the measurements and clinical data using logistic regression. Results: Within the study population (mean age: 56 ± 18 years), ten patients presented with FNS. The correlations between FNS and facial canal diameter (p = 0.09), wall thickness (p = 0.27), distance to CI cable (p = 0.44), and angle with chorda tympani (p = 0.75) were statistically non-significant. There were statistical significances for previous history of meningitis/encephalitis (p = 0.001), extracochlear-electrode-contacts (p = 0.002), scala-vestibuli position (p = 0.02), younger patients’ age (p = 0.03), lateral-wall-electrode type (p = 0.04), and early/childhood onset hearing loss (p = 0.04). Histories of meningitis/encephalitis and extracochlear-electrode-contacts were included in the first two steps of the multivariate logistic regression. Conclusion: The mastoid-facial canal radiological assessment and the positional relationship with the CI electrode provide no predictor of postoperative FNS. Histories of meningitis/encephalitis and extracochlear-electrode-contacts are important risk factors.
Clinical speech perception tests with simple presentation conditions often overestimate the impact of signal preprocessing on speech perception in complex listening environments. A new procedure was developed to assess speech perception in interleaved acoustic environments of different complexity that allows investigation of the impact of an automatic scene classification (ASC) algorithm on speech perception. The procedure was applied in cohorts of normal hearing (NH) controls and uni- and bilateral cochlear implant (CI) users. Speech reception thresholds (SRTs) were measured by means of a matrix sentence test in five acoustic environments that included different noise conditions (amplitude modulated and continuous), two spatial configurations, and reverberation. The acoustic environments were encapsulated in a randomized, mixed order single experimental run. Acoustic room simulation was played back with a loudspeaker auralization setup with 128 loudspeakers. 18 NH, 16 unilateral, and 16 bilateral CI users participated. SRTs were evaluated for each individual acoustic environment and as mean-SRT. Mean-SRTs improved by 2.4 dB signal-to-noise ratio for unilateral and 1.3 dB signal-to-noise ratio for bilateral CI users with activated ASC. Without ASC, the mean-SRT of bilateral CI users was 3.7 dB better than the SRT of unilateral CI users. The mean-SRT indicated significant differences, with NH group performing best and unilateral CI users performing worse with a difference of up to 13 dB compared to NH. The proposed speech test procedure successfully demonstrated that speech perception and benefit with ASC depend on the acoustic environment.
Purpose: Monocentric, prospective study to investigate whether concomitant support of cochlear implant (CI) patients by CI-trained otolaryngologists and application of a standardized head bandage can minimize potential complications during magnetic resonance imaging (MRI).
Methods: Thirty-seven patients with 46 CIs underwent MRI with a prophylactic head bandage. All participants and the otolaryngologist at the CI center completed pre- and post-MRI questionnaires documenting body region scanned, duration of MRI and bandage wear, field strength during the scan, and any complications. If pain was experienced, it was assessed using a visual analog scale (1–10).
Results: MRI was performed without adverse events in 37.8% of cases. Magnet dislocation requiring surgical revision occurred in 2% of cases. Pain was reported in 86% of cases, often due to the tightness of the dressing. Patients with rotating, MRI-compatible magnets reported significantly less pain than participants with older-generation implants. In 11% of cases, the MRI was discontinued.
Conclusion: Serious complications during MRI in cochlear implant patients are rare. Pain is the most common adverse event, probably mainly due to the tight bandage required by most implant types. With newer generations of magnets, these patients experience less pain, no dislocation of the magnets, and no need for bandaging. Although magnet dislocation cannot be completely prevented in older generations of implants, it appears to be reduced by good patient management, which recommends examination under the guidance of physicians trained in the use of hearing implants.
The aim of the study was to obtain volumetric data of the components of the inner ear using three-dimensional reconstruction of high-resolution cone-beam computed tomography (CBCT) images. Two hundred three CBCT image series of the temporal bone from 118 anatomically normal patients (55 women and 63 men; mean age: 49.4 ± 20.4 years) with different suspected disorders were included in this study. Normative volumetric measurements of the inner ear, the cochlea, the semicircular canals (SSC), and the vestibule were determined using a semi-automated reconstruction method of the Workstation. Volumetric measurements were successfully completed in all 118 patients. Mean inner ear, cochlear, and vestibule volumes were statistically significantly larger in males than in females on both sides (p < 0.001). Regarding the semicircular canals, no statistically significant (p = 0.053) volume difference was found. The difference between the volumes on both sides was not significant. No correlation between the patient’s age and the volume of the compartments was seen (p > 0.05). There was no significant difference between mean bony inner ear volumes when the clinical diagnoses were compared (p > 0.05 for all clinical diagnoses and volumes). Our study concluded that three-dimensional reconstruction and assessment of the volumetric measurements of the inner ear can be obtained using high-resolution CBCT imaging.
Long-term effects on the quality of life following cochlear implant treatment in older patients
(2022)
Purpose: Even in older patients, hearing rehabilitation with a cochlear implant has become an established method for deafened or severely hearing-impaired patients. In addition to the hearing improvement, numerous other effects of CI treatment can be observed in clinical routine. In the literature, there is multiple evidence for a rapid and significant improvement in quality of life with CI treatment. The aim of this study was to evaluate the long-term effects of hearing rehabilitation using CI on the quality of life in older patients (≥ 65 years).
Methods: This prospective cross-sectional study examined 84 patients between the age of 65 and 101 years who received unilateral CI treatment for the first time between one and 10 years ago. The World Health Organization Quality-of-Life Scale-Old (WHOQL-OLD) was used to determine the quality of life. The study cohort was divided into three groups to compare the quality of life over time: group I (1–3 years after CI treatment), group II (4–6 years after CI treatment), and group III (7–10 years after CI treatment). In addition, the data from this study were compared with the results of our previous study (Issing et al. 2020) in which we focused on the first 6 months after CI treatment.
Results: In all three groups, there was a significant improvement in monosyllabic discrimination within 1 year after CI fitting (p > 0.001). No significant differences were found between the three groups. There were no significant differences between the three groups in the WHOQOL-OLD total score (p = 0.487) or any of the other six facets. Moreover, no significant differences were found compared to the study group of our previous study 6 months after CI treatment.
Conclusion: This study demonstrates the long-term stability of the improved quality of life following unilateral CI treatment in patients aged 65 years or older.
Purpose: The treatment with a cochlear implant (CI) is the gold standard in therapy of patients with profound hearing loss or deafness. Successful hearing rehabilitation with a CI is a complex, multi-stage process. In medicine, “Clinical Practice Guidelines” (CPG) are widely accepted for the standardization of such processes. These are supplemented by medical registries in which data regarding the treatment can be collected and evaluated. The aim of this paper is to identify currently existing CI-related CPGs and registries in Europe.
Methods: Between 01/2021 and 06/2021, 42 countries on the European continent, including the United Kingdom, Russia and Turkey, were screened using an internet search (search engine: Google) and a key word search in the Pubmed database. Search terms were the respective country name combined with the following terms: “Cochlear Implant”, “CI”, “Cochlear implant clinical practice guideline”, “CI Guideline”, “Cochlear Implant Registry”, “CI Registry”, “Ear nose throat society”. The internet search was conducted in English as well as in the corresponding national language. The objective was to identify a CI-related CPG or registry.
Results: A CPG was found in 16 of 42 (38%) countries. In terms of population, this accounts for 645 million out of 838 million people (77%). A registry existed in 4 of the 42 (10%) countries assessed. This corresponds to 102 million out of 838 million (12%) people. In total, 4 out of 42 countries (10%) had both a CPG and a registry.
Conclusion: Our work shows numerous efforts in Europe to standardize CI care at the national level. While most people in Europe already live in countries with a CPG, this is not the case for CI registries. European-wide consensus on CPGs or registries does not yet exist. The present study thus provides a first assessment of the distribution of CI-related CPGs and registries.
Objective: Vertigo is a common side effect of cochlear implant (CI) treatment. This prospective study examines the incidence of postoperative vertigo over time and aims to analyze influencing factors such as electrode design and insertion angle (IA).
Study Design and Setting: This is a prospective study which has been conducted at a tertiary referral center (academic hospital).
Patients: A total of 29 adults were enrolled and received a unilateral CI using one of six different electrode carriers, which were categorized into “structure-preserving” (I), “potentially structure-preserving” (II), and “not structure-preserving” (III).
Intervention: Subjective vertigo was assessed by questionnaires at five different time-points before up to 6 months after surgery. The participants were divided into four groups depending on the time of the presence of vertigo before and after surgery. Preoperatively and at 6 months postoperatively, a comprehensive vertigo diagnosis consisting of Romberg test, Unterberger test, subjective visual vertical, optokinetic test, video head impulse test, and caloric irrigation test was performed. In addition, the IA was determined, and the patients were divided in two groups (<430°; ≥430°).
Main Outcome Measures: The incidence of vertigo after CI surgery (group 1) was reported, as well as the correlation of subjective vertigo with electrode array categories (I–III) and IA.
Results: Among the participants, 45.8% experienced new vertigo after implantation. Based on the questionnaire data, a vestibular origin was suspected in 72.7%. The results did not show a significant correlation with subjective vertigo for any of the performed tests. In group 1 with postoperative vertigo, 18% of patients showed conspicuous results in a quantitative analysis of caloric irrigation test despite the fact that the category I or II electrodes were implanted, which are suitable for structure preservation. Average IA was 404° for the overall group and 409° for group 1. There was no statistically significant correlation between IA and perceived vertigo.
Conclusions: Though vertigo after CI surgery seems to be a common complication, the test battery used here could not objectify the symptoms. Further studies should clarify whether this is due to the multifactorial cause of vertigo or to the lack of sensitivity of the tests currently in use. The proof of reduced probability for vertigo when using atraumatic electrode carrier was not successful, nor was the proof of a negative influence of the insertion depth.
Purpose: Severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) replicates predominantly in the upper respiratory tract and is primarily transmitted by droplets and aerosols. Taking the medical history for typical COVID-19 symptoms and PCR-based SARS-CoV-2 testing have become established as screening procedures. The aim of this work was to describe the clinical appearance of SARS-CoV-2-PCR positive patients and to determine the SARS-CoV-2 contact risk for health care workers (HCW).
Methods: The retrospective study included n = 2283 SARS-CoV-2 PCR tests from n = 1725 patients with otorhinolaryngological (ORL) diseases performed from March to November 2020 prior to inpatient treatment. In addition, demographic data and medical history were assessed.
Results: n = 13 PCR tests (0.6%) were positive for SARS-CoV-2 RNA. The positive rate showed a significant increase during the observation period (p < 0.01). None of the patients had clinical symptoms that led to a suspected diagnosis of COVID-19 before PCR testing. The patients were either asymptomatic (n = 4) or had symptoms that were interpreted as symptoms typical of the ORL disease or secondary diagnoses (n = 9).
Conclusion: The identification of SARS-CoV-2-positive patients is a considerable challenge in clinical practice. Our findings illustrate that taking a medical history alone is of limited value and cannot replace molecular SARS-CoV-2 testing, especially for patients with ORL diseases. Our data also demonstrate that there is a high probability of contact with SARS-CoV-2-positive patients in everyday clinical practice, so that the use of personal protective equipment, even in apparently “routine cases”, is highly recommended.
Background: Due to the coronavirus disease 2019 (COVID-19) pandemic, interventions in the upper airways are considered high-risk procedures for otolaryngologists and their colleagues. The purpose of this study was to evaluate limitations in hearing and communication when using a powered air-purifying respirator (PAPR) system to protect against severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) transmission and to assess the benefit of a headset. Methods: Acoustic properties of the PAPR system were measured using a head and torso simulator. Audiological tests (tone audiometry, Freiburg speech test, Oldenburg sentence test (OLSA)) were performed in normal-hearing subjects (n = 10) to assess hearing with PAPR. The audiological test setup also included simulation of conditions in which the target speaker used either a PAPR, a filtering face piece (FFP) 3 respirator, or a surgical face mask. Results: Audiological measurements revealed that sound insulation by the PAPR headtop and noise, generated by the blower-assisted respiratory protection system, resulted in significantly deteriorated hearing thresholds (4.0 ± 7.2 dB hearing level (HL) vs. 49.2 ± 11.0