Use of reflective tape to detect ultrasound transducer movement: a validation study

  • During dynamic ultrasound assessments, unintended transducer movement over the skin needs to be prevented as it may bias the results. The present study investigated the validity of two methods quantifying transducer motion. An ultrasound transducer was moved on a pre-specified 3 cm distance over the semitendinosus muscle of eleven adults (35.8 ± 9.8 years), stopping briefly at intervals of 0.5 cm. Transducer motion was quantified (1) measuring the 2-D displacement of the shadow produced by reflective tape (RT) attached to the skin and (2) using a marker-based, three-dimensional movement analysis system (MAS). Differences between methods were detected with Wilcoxon tests; associations were checked by means of intraclass correlation coefficients (ICC 3.1) and Bland–Altman plots. Values for RT (r = 0.57, p < 0.001) and MAS (r = 0.19, p = 0.002) were significantly higher than true distances (TD). Strong correlations were found between RT and TD (ICC: 0.98, p < 0.001), MAS and TD (ICC: 0.95, p < 0.001), and MAS and RT (ICC: 0.97, p < 0.001). Bland–Altman plots showed narrow limits of agreement for both RT (−0.49 to 0.13 cm) and MAS (−0.49 to 0.34 cm) versus TD. RT and MAS are valid methods to quantify US transducer movement. In view of its low costs and complexity, RT can particularly be recommended for application in research and clinical practice. View Full-Text Keywords: ultrasound; reflective tape; transducer movement

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar
Metadaten
Verfasserangaben:Lisa MohrORCiD, Lutz VogtGND, Jan WilkeORCiDGND
URN:urn:nbn:de:hebis:30:3-576499
DOI:https://doi.org/10.3390/life11020104
ISSN:2075-1729
Titel des übergeordneten Werkes (Deutsch):Life
Verlag:MDPI
Verlagsort:Basel
Dokumentart:Wissenschaftlicher Artikel
Sprache:Englisch
Datum der Veröffentlichung (online):30.01.2021
Datum der Erstveröffentlichung:30.01.2021
Veröffentlichende Institution:Universitätsbibliothek Johann Christian Senckenberg
Datum der Freischaltung:04.02.2021
Freies Schlagwort / Tag:reflective tape; transducer movement; ultrasound
Jahrgang:11
Ausgabe / Heft:Article 104
Seitenzahl:8
HeBIS-PPN:476221633
Institute:Psychologie und Sportwissenschaften / Sportwissenschaften
DDC-Klassifikation:7 Künste und Unterhaltung / 79 Sport, Spiele, Unterhaltung / 790 Freizeitgestaltung, darstellende Künste, Sport
Sammlungen:Universitätspublikationen
Open-Access-Publikationsfonds:Psychologie und Sportwissenschaften
Lizenz (Deutsch):License LogoCreative Commons - Namensnennung 4.0