Differential prognostic accuracy of right ventricular dysfunction, the Seattle heart failure model and the MAGGIC score in patients with severe mitral regurgitation undergoing the MitraClip® procedure

  • Background: MitraClip ® (MC) is an established procedure for severe mitral regurgitation (MR) in patients deemed unsuitable for surgery. Right ventricular dysfunction (RVD) is associated with a higher mortality risk. The prognostic accuracy of heart failure risk scores like the Seattle heart failure model (SHFM) and Meta-Analysis Global Group in Chronic Heart Failure (MAGGIC) score in pts undergoing MC with or without RVD has not been investigated so far. Methods: SHFM and MAGGIC score were calculated retrospectively. RVD was determined as tricuspid annular plane systolic excursion (TAPSE) ≤15 mm. Area under receiver operating curves (AUROC) of SHFM and MAGGIC were performed for one-year all-cause mortality after MC. Results: N = 103 pts with MR III° (73 ± 11 years, LVEF 37 ± 17%) underwent MC with a reduction of at least I° MR. One-year mortality was 28.2%. In Kaplan-Meier analysis, one- year mortality was significantly higher in RVD-pts (34.8% vs 2.8%, p = 0.009). Area under the Receiver Operating Characteristic (AUROC) for SHFM and MAGGIC were comparable for both scores (SHFM: 0.704, MAGGIC: 0.692). In pts without RVD, SHFM displayed a higher AUROC and therefore better diagnostic accuracy (SHFM: 0.776; MAGGIC: 0.551, p < 0.05). In pts with RVD, MAGGIC and SHFM displayed comparable AUROCs. Conclusion: RVD is an important prognostic marker in pts undergoing MC. SHFM and MAGGIC displayed adequate over-all prognostic power in these pts. Accuracy differed in pts with and without RVD, indicating higher predictive power of the SHFM score in pts without RVD.

Volltext Dateien herunterladen

Metadaten exportieren

Metadaten
Verfasserangaben:Andreas Stephan HeylGND, Brigitte Luu, Markus Wieszner, Aria Nikkhoo, Florian Hartmut SeegerGND, Katrin Hemmann, Birgit AßmusORCiDGND, Bernhard Kaess, Andreas M. ZeiherORCiDGND, Claudia Walther, Stephan Fichtlscherer, Jörg Florian Hannes HonoldORCiDGND
URN:urn:nbn:de:hebis:30:3-623599
DOI:https://doi.org/10.1016/j.ijcha.2020.100641
ISSN:2352-9067
Titel des übergeordneten Werkes (Englisch):International journal of cardiology
Verlag:Elsevier
Verlagsort:Amsterdam [u.a.]
Dokumentart:Wissenschaftlicher Artikel
Sprache:Englisch
Datum der Veröffentlichung (online):12.10.2020
Datum der Erstveröffentlichung:12.10.2020
Veröffentlichende Institution:Universitätsbibliothek Johann Christian Senckenberg
Datum der Freischaltung:03.08.2021
Freies Schlagwort / Tag:Functional mitral regurgitation; MAGGIC score; MitraClip; Seattle heart failure model; TAPSE
Jahrgang:31
Ausgabe / Heft:art. 100641
Seitenzahl:8
Erste Seite:1
Letzte Seite:8
HeBIS-PPN:489227686
Institute:Medizin / Medizin
DDC-Klassifikation:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Sammlungen:Universitätspublikationen
Open-Access-Publikationsfonds:Medizin
Lizenz (Deutsch):License LogoCreative Commons - Namensnennung-Nicht kommerziell - Keine Bearbeitung 4.0