A new implant device to prevent edema-associated underdosage in high-dose-rate interstitial brachytherapy of mobile tongue cancer

  • Purpose: Tongue edema is a potential cause of treatment target underdosage in high-dose-rate interstitial brachytherapy (HDR-ISBT) of mobile tongue cancer. To prevent such edema-associated alteration of dosimetry, we developed a special silicon device. In this report we communicate our initial experience with two mobile tongue cancer patients whom we treated using this new device. Material and methods: The device consists of silicone tubes with a fixed width and scalable length depending on tongue size. These tubes are lined and fixed like a palisade, allowing the device to be used also as a template. The device is placed next to the lateral border of the tongue and on the floor of the mouth. In addition, a vinyl template can be placed on the dorsal tongue surface with both devices combined for implantation guidance. Between June and August 2012, two patients with locally confined tongue cancer were treated. Results: Between June and August 2012, two mobile tongue cancer patients classified as cT2N0M0 were treated with HDR-ISBT using the silicone device. They underwent ISBT as monotherapy with fractional doses of 6.0 Gy up to a total physical dose of 54.0 Gy. The D90 (CTV) values of both patients were 6.3 Gy and 6.6 Gy and the D2cc (mandible) values were 3.4 Gy and 2.6 Gy, respectively. At present, both patients remain without local disease recurrence at 60 and 56 months after ISBT, respectively. Conclusions: The described silicone device has the potential to prevent underdosage to the treatment target related to tongue edema. It has been shown to be safe and easy to implement.

Volltext Dateien herunterladen

Metadaten exportieren

Metadaten
Verfasserangaben:Ken Yoshida, Tadayuki Kotsuma, Hironori Akiyama, Hideya Yamazaki, Tadashi Takenaka, Koji Masui, Yutaka Tsujimoto, Naoya Murakami, Yasuo Uesugi, Taiju Shimbo, Nobuhiko Yoshikawa, Hiroto Yoshioka, Mio Nakata, Takumi Arika, Yuji Takaoka, Eiichi Tanaka, Nikolaos TselisGND
URN:urn:nbn:de:hebis:30:3-530646
DOI:https://doi.org/10.5114/jcb.2019.91225
ISSN:2081-2841
ISSN:1689-832X
Pubmed-Id:https://pubmed.ncbi.nlm.nih.gov/31969916
Titel des übergeordneten Werkes (Englisch):Journal of contemporary brachytherapy
Verlag:Termedia
Verlagsort:Poznań
Dokumentart:Wissenschaftlicher Artikel
Sprache:Englisch
Jahr der Fertigstellung:2019
Datum der Erstveröffentlichung:25.12.2019
Veröffentlichende Institution:Universitätsbibliothek Johann Christian Senckenberg
Datum der Freischaltung:04.03.2020
Freies Schlagwort / Tag:high-dose-rate interstitial brachytherapy; mobile tongue cancer; silicone device; tongue edema
Jahrgang:11
Ausgabe / Heft:6
Seitenzahl:6
Erste Seite:573
Letzte Seite:578
Bemerkung:
Copyright: © 2019 Termedia Sp. z o. o. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
HeBIS-PPN:461422719
Institute:Medizin / Medizin
DDC-Klassifikation:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Sammlungen:Universitätspublikationen
Lizenz (Deutsch):License LogoCreative Commons - Namensnennung-Keine kommerzielle Nutzung-Weitergabe unter gleichen Bedingungen