Physik
Refine
Document Type
- Conference Proceeding (22)
- Article (6)
Language
- English (28)
Has Fulltext
- yes (28)
Is part of the Bibliography
- no (28)
Institute
- Physik (28)
Superconducting, energy variable heavy ion linac with constant
β, multicell cavities of CH-type
(2009)
An energy variable ion linac consisting of multigap, constant-β cavities was developed. The effect of phase sliding, unavoidable in any constant-β section, is leading to a coherent rf phase motion, which fits well to the H-type structures with their long π-mode sections and separated lenses. The exact periodicity of the cell lengths within each cavity results in technical advantages, such as higher calculation accuracy when only one single period can be simulated, simpler manufacturing, and tuning. This is most important in the case of superconducting cavities. By using this concept, an improved design for a 217 MHz cw superconducting heavy ion linac with energy variation has been worked out. The small output energy spread of ± 3 AkeV is provided over the whole range of energy variation from 3.5 to 7.3 AMeV. These capabilities would allow for a competitive research in the field of radiochemistry and for a production of super heavy elements (SHE), especially. A first 19-cell cavity of that type was designed, built, and rf tested successfully at the Institute for Applied Physics (IAP) Frankfurt. A 325.224 MHz, seven-cell cavity with constant β = 0.16 is under development and will be operated in a frequency controlled mode. It will be equipped with a power coupler and beam tests with Unilac beams at GSI are foreseen.
Motivated by the necessary replacement of the GSI UNILAC poststripper linac, a compact and efficient linac design based on IH-type cavities has been developed. Using KONUS beam dynamics, it was possible to design a linac consisting of only five cavities that can be operated by the existing UNILAC RF amplifier structure. The transversal focusing scheme is based on magnetic quadrupole triplet lenses. The optimized design provides full transmission and low emittance growth for the design current of 15 emA U28+, accelerating the beam from 1.4 MeV/u to 11.4 MeV/u. Extensive error studies were performed to define tolerances and verify the stability of the design with respect to misalignment and injection parameters. The design provides a compact and cost effective alternative to a new Alvarez linac. With a total length of just 22.8 meters it will leave room for future energy upgrades in the UNILAC tunnel.
The crossbar H-mode (CH) cavity is an accelerating structure operated in the H21(0) mode. The robustness of the crossbar geometry allows one to realize room temperature as well as superconducting linac cavities. The shunt impedance characteristics of this structure are attractive to develop proton and heavy ion linacs in the low and medium beta range. A first room temperature eight-cell prototype has proven the feasibility of the crossbar design in terms of mechanical construction, copper plating, and cooling. An innovative rf coupling concept has been developed where two CH cavities are connected by a two gap E010-mode resonator which, at the same time, provides transverse focusing by a quadrupole triplet. The concept has been applied in the design of the new FAIR proton linac and a scaled model of the second cavity of this injector has been built and tested too. The full scale prototype is now under construction at the University of Frankfurt. In this paper, the room temperature CH cavity development as well as the general layout of the FAIR proton injector (70 MeV, 325 MHz, 70 mA) is presented and discussed.
The crossbar-H-mode (CH) structure is the first superconducting multicell drift tube cavity for the low and medium energy range operated in the H21 mode. Because of the large energy gain per cavity, which leads to high real estate gradients, it is an excellent candidate for the efficient acceleration in high power proton and ion accelerators with fixed velocity profile. A prototype cavity has been developed and tested successfully with a gradient of 7MV/m. A few new superconducting CH cavities with improved geometries for different high power applications are under development at present. One cavity (f=325 MHz, β=0.16, seven cells) is currently under construction and studied with respect to a possible upgrade option for the GSI UNILAC. Another cavity (f=217 MHz, β=0.059, 15 cells) is designed for a cw operated energy variable heavy ion linac application. Furthermore, the EUROTRANS project (European research program for the transmutation of high level nuclear waste in an accelerator driven system, 600 MeV protons, 352 MHz) is one of many possible applications for this kind of superconducting rf cavity. In this context a layout of the 17 MeV EUROTRANS injector containing four superconducting CH cavities was proposed by the Institute for Applied Physics (IAP) Frankfurt. The status of the cavity development related to the EUROTRANS injector is presented.
The HITRAP linear decelerator currently being set up at GSI will provide slow, few keV/u highly charged ions for atomic physics experiments. The expected beam intensity is up to 105 ions per shot. To optimize phase and amplitude of the RF systems intensity, bunch length and kinetic energy of the particles need to be monitored. The bunch length that we need to fit is about 2 ns, which is typically measured by capacitive pickups. However, they do not work for the low beam intensities that we face. We investigated the bunch length with a fast CVD diamond detector working in single particle counting mode. Averaging over 8 shots yields a clear, regular picture of the bunched beam. Energy measurements by capacitive pickups are limited by the presence of intense primary and partially decelerated beam and hence make tuning of the IH-structure impossible. The energy of the decelerated fraction of the beam behind the first deceleration cavity was determined to about 10 % accuracy with a permanent dipole magnet combined with a MCP. Better detector calibration should help reaching the required 1%. Design of the detectors as well as the results of the measurements will be presented.
A test stand for optical beam tomography was developed. As a new non-destructive beam-diagnostic system for high current ion beams, the test stand will be installed in the low energy beam transport section (LEBT) of the Frankfurt Neutron Source (FRANZ) behind the chopper system. The test stand consists of a rotatable vacuum chamber with a mounted CCD camera. The maximum rotation angle amounts to 270°. In a first phase the optical beam profile measurement and 3D density reconstruction is tested with a time independent 10 keV He beam. The measurements and performance of data processing algorithms are compared with the beam transport simulations. In a later phase the performance with time dependent beams (120 keV, 200 mA) at a repetition rate of 250 kHz and a duty cycle of 2.5% has to be evaluated. An overview of the first phase results is shown.
Space charge lenses use a confined electron cloud for the focusing of ion beams. The focusing strength is given by the electron density whereas the density distribution influences the mapping quality of the space charge lens and is related to the confinement. The plasma parameters, loss as well as production mechanisms have a strong impact on plasma beam interactions. A scaled up space charge lens was constructed to investigate the properties of a nonneutral plasmas in detail. New non-interceptive diagnostic has been developed to characterize the collective behaviour of the confined nonneutral plasma in terms of an optimized lens design and parameters. Experimental results will be presented in comparison with numerical simulations.
A non-interceptive optical diagnostic system on the basis of beam tomography, was developed for the planned Frankfurt Neutron Source (FRANZ). The proton driver linac of FRANZ will provide energies up to 2.0 MeV. The measurement device will non-interceptively derive required beam parameters at the end of the LEBT at beam energies of 120 keV and a current of 200 mA. On a narrow space of 351.2 mm length a rotatable tomography tank will perform a multi-turn tomography with a high and stable vacuum pressure. The tank allows to plug different measurement equipment additionally to the CCD Camera installed, to perform optical beam tomography. A collection of developed algorithms provides information about the density distribution, shape, size, location and emittance on the basis of CCD images. Simulated, as well as measured data have been applied to the evaluation algorithms to test the reliability of the beam. The actual contribution gives an overview on the current diagnostic possibilities of this diagnostic system.
Space charge lenses using a stable electron cloud for focusing low energy heavy ion beams are an alternative concept to conventional ion optics. Due to external fields electrons are confined inside the lens’ volume. In case of a homogeneously distributed electron cloud the linear electric space charge field enables beam focusing free of aberration. Since the mapping quality of the lens is related to the confinement, non-destructive diagnostics has been developed to determine the plasma parameters and to characterize the collective behavior of the confined nonneutral plasma. Moreover, a scaled up space charge lens was constructed for a detailed investigation of the nonneutral plasma properties as well as beam interactions with a stable confined electron cloud. Experimental results will be presented in comparison with numerical simulations.
As the successor of the EUROTRANS project, the MAX project is aiming to continue the R&D effects for a European Accelerator-Driven System and to bring the conceptual design to reality. The layout of the driver linac for MAX will follow the reference design made for the XT-ADS phase of the EUROTRANS project. For the injector part, new design strategies and approaches, e.g. half resonant frequency, half transition-energy between the RFQ and the CH-DTL, and using the 4-rod RFQ structure instead of the originally proposed 4-vane RFQ, have been conceived and studied to reach a more reliable CW operation at reduced costs. In this paper, the design and simulation results of the MAX injector are presented.