Refine
Year of publication
- 2020 (3) (remove)
Document Type
- Article (3)
Language
- English (3)
Has Fulltext
- yes (3)
Is part of the Bibliography
- no (3) (remove)
Keywords
- Acute HIV infection (1)
- Acute lymphocytic leukaemia (1)
- COVID-19 (1)
- Chemotherapy (1)
- HIV (1)
- PCR (1)
- Rapid diagnostic test (1)
- SARS-CoV-2 (1)
- Seroconverter (1)
- diagnostic test (1)
Institute
- Medizin (3)
In resource-limited or point-of-care settings, rapid diagnostic tests (RDTs), that aim to simultaneously detect HIV antibodies and p24 capsid (p24CA) antigen with high sensitivity, can pose important alternatives to screen for early infections. We evaluated the performance of the antibody and antigen components of the old and novel version of the Determine™ HIV-1/2 Ag/Ab Combo RDTs in parallel to quantifications in a fourth-generation antigen/antibody immunoassay (4G-EIA), p24CA antigen immunoassay (p24CA-EIA), immunoblots, and nucleic acid quantification. We included plasma samples of acute, treatment-naïve HIV-1 infections (Fiebig stages I–VI, subtypes A1, B, C, F, CRF02_AG, CRF02_AE, URF) or chronic HIV-1 and HIV-2 infections. The tests’ antigen component was evaluated also for a panel of subtype B HIV-1 transmitted/founder (T/F) viruses, HIV-2 strains and HIV-2 primary isolates. Furthermore, we assessed the analytical sensitivity of the RDTs to detect p24CA using a highly purified HIV-1NL4-3 p24CA standard. We found that 77% of plasma samples from acutely infected, immunoblot-negative HIV-1 patients in Fiebig stages II–III were identified by the new RDT, while only 25% scored positive in the old RDT. Both RDTs reacted to all samples from chronically HIV-1-infected and acutely HIV-1-infected patients with positive immunoblots. All specimens from chronically infected HIV-2 patients scored positive in the new RDT. Of note, the sensitivity of the RDTs to detect recombinant p24CA from a subtype B virus ranged between 50 and 200 pg/mL, mirrored also by the detection of HIV-1 T/F viruses only at antigen concentrations tenfold higher than suggested by the manufacturer. The RTD failed to recognize any of the HIV-2 viruses tested. Our results indicate that the new version of the Determine™ HIV-1/2 Ag/Ab Combo displays an increased sensitivity to detect HIV-1 p24CA-positive, immunoblot-negative plasma samples compared to the precursor version. The sensitivity of 4G-EIA and p24CA-EIA to detect the major structural HIV antigen, and thus to diagnose acute infections prior to seroconversion, is still superior.
The nucleoside analogue nelarabine, the prodrug of arabinosylguanine (AraG), is effective against T-cell acute lymphoblastic leukaemia (T-ALL) but not against B-cell ALL (B-ALL). The underlying mechanisms have remained elusive. Here, data from pharmacogenomics studies and a panel of ALL cell lines reveal an inverse correlation between nelarabine sensitivity and the expression of SAMHD1, which can hydrolyse and inactivate triphosphorylated nucleoside analogues. Lower SAMHD1 abundance is detected in T-ALL than in B-ALL in cell lines and patient-derived leukaemic blasts. Mechanistically, T-ALL cells display increased SAMHD1 promoter methylation without increased global DNA methylation. SAMHD1 depletion sensitises B-ALL cells to AraG, while ectopic SAMHD1 expression in SAMHD1-null T-ALL cells induces AraG resistance. SAMHD1 has a larger impact on nelarabine/AraG than on cytarabine in ALL cells. Opposite effects are observed in acute myeloid leukaemia cells, indicating entity-specific differences. In conclusion, SAMHD1 promoter methylation and, in turn, SAMHD1 expression levels determine ALL cell response to nelarabine.
Multicentre comparison of quantitative PCR-based assays to detect SARS-CoV-2, Germany, March 2020
(2020)
Containment strategies and clinical management of coronavirus disease (COVID-19) patients during the current pandemic depend on reliable diagnostic PCR assays for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Here, we compare 11 different RT-PCR test systems used in seven diagnostic laboratories in Germany in March 2020. While most assays performed well, we identified detection problems in a commonly used assay that may have resulted in false-negative test results during the first weeks of the pandemic.