Refine
Year of publication
Language
- English (260)
Has Fulltext
- yes (260)
Is part of the Bibliography
- no (260)
Keywords
- BESIII (16)
- e +-e − Experiments (11)
- Branching fraction (10)
- Hadronic decays (5)
- Particle and Resonance Production (5)
- Quarkonium (5)
- Charm Physics (4)
- Exotics (4)
- Lepton colliders (4)
- Spectroscopy (4)
We report the first observation of the decay Λ+c→Σ−π+π+π0, based on data obtained in e+e− annihilations with an integrated luminosity of 567~pb−1 at s√=4.6~GeV. The data were collected with the BESIII detector at the BEPCII storage rings. The absolute branching fraction B(Λ+c→Σ−π+π+π0) is determined to be (2.11±0.33(stat.)±0.14(syst.))%. In addition, an improved measurement of B(Λ+c→Σ−π+π+) is determined as (1.81±0.17(stat.)±0.09(syst.))%.
We study the decays of J/ψ and ψ(3686) to the final states Σ(1385)0Σ¯(1385)0 and Ξ0Ξ¯0 based on a single baryon tag method using data samples of (1310.6±7.0)×106 J/ψ and (447.9±2.9)×106 ψ(3686) events collected with the BESIII detector at the BEPCII collider. The decays to Σ(1385)0Σ¯(1385)0 are observed for the first time. The measured branching fractions of J/ψ and ψ(3686)→Ξ0Ξ¯0 are in good agreement with, and much more precise, than the previously published results. The angular parameters for these decays are also measured for the first time. The measured angular decay parameter for J/ψ→Σ(1385)0Σ¯(1385)0, α=−0.64±0.03±0.10, is found to be negative, different to the other decay processes in this measurement. In addition, the "12\% rule" and isospin symmetry in the J/ψ and ψ(3686)→ΞΞ¯ and Σ(1385)Σ¯(1385) systems are tested.
By analyzing 2.93 fb−1 of data taken at the ψ(3770) resonance peak with the BESIII detector, we measure the branching fractions for the hadronic decays D+ → K0S K0S K +, D+ → K0S K0Sπ+, D0 → K0S K0S and D0 → K0S K0S K0S . They are determined to be B(D+ → K0S K0S K +) = (2.54 ± 0.05stat. ± 0.12sys.) × 10−3, B(D+ → K0S K0Sπ+) = (2.70 ± 0.05stat. ± 0.12sys.) × 10−3, B(D0 → K0S K0S ) = (1.67 ± 0.11stat. ± 0.11sys.) × 10−4 and B(D0 → K0S K0S K0S ) = (7.21 ± 0.33stat. ± 0.44sys.) × 10−4, where the second one is measured for the first time and the others are measured with significantly improved precision over the previous measurements.
There has recently been a dramatic renewal of interest in hadron spectroscopy and charm physics. This renaissance has been driven in part by the discovery of a plethora of charmonium-like XYZ states at BESIII and B factories, and the observation of an intriguing proton-antiproton threshold enhancement and the possibly related X(1835) meson state at BESIII, as well as the threshold measurements of charm mesons and charm baryons.
We present a detailed survey of the important topics in tau-charm physics and hadron physics that can be further explored at BESIII during the remaining operation period of BEPCII. This survey will help in the optimization of the data-taking plan over the coming years, and provides physics motivation for the possible upgrade of BEPCII to higher luminosity.
Cross sections of the process 𝑒+𝑒−→𝜋0𝜋0𝐽/𝜓 at center-of-mass energies between 3.808 and 4.600 GeV are measured with high precision by using 12.4 fb−1 of data samples collected with the BESIII detector operating at the BEPCII collider facility. A fit to the measured energy-dependent cross sections confirms the existence of the charmoniumlike state 𝑌(4220). The mass and width of the 𝑌(4220) are determined to be (4220.4±2.4±2.3) MeV/𝑐2 and (46.2±4.7±2.1) MeV, respectively, where the first uncertainties are statistical and the second systematic. The mass and width are consistent with those measured in the process 𝑒+𝑒−→𝜋+𝜋−𝐽/𝜓. The neutral charmonium-like state 𝑍𝑐(3900)0 is observed prominently in the 𝜋0𝐽/𝜓 invariant-mass spectrum, and, for the first time, an amplitude analysis is performed to study its properties. The spin-parity of 𝑍𝑐(3900)0 is determined to be 𝐽𝑃=1+, and the pole position is (3893.1±2.2±3.0)−𝑖(22.2±2.6±7.0) MeV/𝑐2, which is consistent with previous studies of electrically charged 𝑍𝑐(3900)±. In addition, cross sections of 𝑒+𝑒− → 𝜋0𝑍𝑐(3900)0 → 𝜋0𝜋0𝐽/𝜓 are extracted, and the corresponding line shape is found to agree with that of the 𝑌(4220).
Background: Bone age (BA) assessment performed by artificial intelligence (AI) is of growing interest due to improved accuracy, precision and time efficiency in daily routine. The aim of this study was to investigate the accuracy and efficiency of a novel AI software version for automated BA assessment in comparison to the Greulich-Pyle method.
Methods: Radiographs of 514 patients were analysed in this retrospective study. Total BA was assessed independently by three blinded radiologists applying the GP method and by the AI software. Overall and gender-specific BA assessment results, as well as reading times of both approaches, were compared, while the reference BA was defined by two blinded experienced paediatric radiologists in consensus by application of the Greulich-Pyle method.
Results: Mean absolute deviation (MAD) and root mean square deviation (RSMD) were significantly lower between AI-derived BA and reference BA (MAD 0.34 years, RSMD 0.38 years) than between reader-calculated BA and reference BA (MAD 0.79 years, RSMD 0.89 years; p < 0.001). The correlation between AI-derived BA and reference BA (r = 0.99) was significantly higher than between reader-calculated BA and reference BA (r = 0.90; p < 0.001). No statistical difference was found in reader agreement and correlation analyses regarding gender (p = 0.241). Mean reading times were reduced by 87% using the AI system.
Conclusions: A novel AI software enabled highly accurate automated BA assessment. It may improve efficiency in clinical routine by reducing reading times without compromising the accuracy compared with the Greulich-Pyle method.
BACKGROUND: The analysis of microarray time series promises a deeper insight into the dynamics of the cellular response following stimulation. A common observation in this type of data is that some genes respond with quick, transient dynamics, while other genes change their expression slowly over time. The existing methods for detecting significant expression dynamics often fail when the expression dynamics show a large heterogeneity. Moreover, these methods often cannot cope with irregular and sparse measurements.
RESULTS: The method proposed here is specifically designed for the analysis of perturbation responses. It combines different scores to capture fast and transient dynamics as well as slow expression changes, and performs well in the presence of low replicate numbers and irregular sampling times. The results are given in the form of tables including links to figures showing the expression dynamics of the respective transcript. These allow to quickly recognise the relevance of detection, to identify possible false positives and to discriminate early and late changes in gene expression. An extension of the method allows the analysis of the expression dynamics of functional groups of genes, providing a quick overview of the cellular response. The performance of this package was tested on microarray data derived from lung cancer cells stimulated with epidermal growth factor (EGF).
CONCLUSION: Here we describe a new, efficient method for the analysis of sparse and heterogeneous time course data with high detection sensitivity and transparency. It is implemented as R package TTCA (transcript time course analysis) and can be installed from the Comprehensive R Archive Network, CRAN. The source code is provided with the Additional file 1.
Species’ functional traits set the blueprint for pair-wise interactions in ecological networks. Yet, it is unknown to what extent the functional diversity of plant and animal communities controls network assembly along environmental gradients in real-world ecosystems. Here we address this question with a unique dataset of mutualistic bird–fruit, bird–flower and insect–flower interaction networks and associated functional traits of 200 plant and 282 animal species sampled along broad climate and land-use gradients on Mt. Kilimanjaro. We show that plant functional diversity is mainly limited by precipitation, while animal functional diversity is primarily limited by temperature. Furthermore, shifts in plant and animal functional diversity along the elevational gradient control the niche breadth and partitioning of the respective other trophic level. These findings reveal that climatic constraints on the functional diversity of either plants or animals determine the relative importance of bottom-up and top-down control in plant–animal interaction networks.
Aim: The identification of the mechanisms determining spatial variation in biological diversity along elevational gradients is a central objective in ecology and biogeography. Here, we disentangle the direct and indirect effects of abiotic drivers (climatic conditions, and land use) and biotic drivers (vegetation structure and food resources) on functional diversity and composition of bird and bat assemblages along a tropical elevational gradient. Location: Southern slopes of Mt. Kilimanjaro, Tanzania, East Africa. Methods: We counted birds and recorded bat sonotypes on 58 plots distributed in near-natural and anthropogenically modified habitats from 700 to 4,600 m above sea level. For the recorded taxa, we compiled functional traits related to movement, foraging and body size from museum specimens and databases. Further, we recorded mean annual temperature, precipitation, vegetation complexity as well as the number of fruits, flowers, and insect biomass as measures of resource availability on each study site. Results: Using path analyses, we found similar responses of bird and bat functional diversity to the variation in abiotic and biotic drivers along the elevational gradient. In contrast, the functional composition of both taxa showed distinct responses to abiotic and biotic drivers. For both groups, direct temperature effects were most important, followed by resource availability, precipitation and vegetation complexity. Main Conclusions: Our findings indicate that physiological and metabolic constraints imposed by temperature and resource availability determine the functional diversity of bird and bat assemblages, whereas the composition of individual functional traits is driven by taxon-specific processes. Our study illustrates that distinct filtering mechanisms can result in similar patterns of functional diversity along broad environmental gradients. Such differences need to be taken into account when it comes to conserving the functional diversity of flying vertebrates on tropical mountains.
Objectives: To compare dual-energy CT (DECT) and MRI for assessing presence and extent of traumatic bone marrow edema (BME) and fracture line depiction in acute vertebral fractures. Methods: Eighty-eight consecutive patients who underwent dual-source DECT and 3-T MRI of the spine were retrospectively analyzed. Five radiologists assessed all vertebrae for presence and extent of BME and for identification of acute fracture lines on MRI and, after 12 weeks, on DECT series. Additionally, image quality, image noise, and diagnostic confidence for overall diagnosis of acute vertebral fracture were assessed. Quantitative analysis of CT numbers was performed by a sixth radiologist. Two radiologists analyzed MRI and grayscale DECT series to define the reference standard. Results: For assessing BME presence and extent, DECT showed high sensitivity (89% and 84%, respectively) and specificity (98% in both), and similarly high diagnostic confidence compared to MRI (2.30 vs. 2.32; range 0–3) for the detection of BME (p = .72). For evaluating acute fracture lines, MRI achieved high specificity (95%), moderate sensitivity (76%), and a significantly lower diagnostic confidence compared to DECT (2.42 vs. 2.62, range 0–3) (p < .001). A cutoff value of − 0.43 HU provided a sensitivity of 89% and a specificity of 90% for diagnosing BME, with an overall AUC of 0.96. Conclusions: DECT and MRI provide high diagnostic confidence and image quality for assessing acute vertebral fractures. While DECT achieved high overall diagnostic accuracy in the analysis of BME presence and extent, MRI provided moderate sensitivity and lower confidence for evaluating fracture lines.