Refine
Year of publication
Document Type
- Article (733)
- Preprint (682)
- Conference Proceeding (6)
- Working Paper (5)
- Report (3)
- Doctoral Thesis (1)
Has Fulltext
- yes (1430)
Is part of the Bibliography
- no (1430)
Keywords
- Heavy Ion Experiments (20)
- Hadron-Hadron Scattering (11)
- Hadron-Hadron scattering (experiments) (11)
- LHC (9)
- Heavy-ion collision (6)
- immunotherapy (6)
- COVID-19 (5)
- ALICE experiment (4)
- Breast cancer (4)
- Collective Flow (4)
Institute
- Physik (1124)
- Frankfurt Institute for Advanced Studies (FIAS) (957)
- Informatik (924)
- Medizin (189)
- Geowissenschaften (48)
- Biowissenschaften (9)
- ELEMENTS (8)
- Biochemie, Chemie und Pharmazie (7)
- Georg-Speyer-Haus (6)
- Institut für Ökologie, Evolution und Diversität (6)
The design and operation of innovative nuclear systems requires a better knowledge of the capture and fission cross sections of the Pu isotopes. For the case of capture on 242Pu, a reduction of the uncertainty in the fast region down to 8-12% is required. Moreover, aiming at improving the evaluation of the fast energy range in terms of average parameters, the OECD NEA High Priority Request List (HPRL) requests high-resolution capture measurements with improved accuracy below 2 keV. The current uncertainties also affect the thermal point, where previous experiments deviate from each other by 20%. A fruitful collaboration betwen JGU Mainz and HZ Dresden-Rossendorf within the EC CHANDA project resulted in a 242Pu sample consisting of a stack of seven fission-like targets making a total of 95(4) mg of 242Pu electrodeposited on thin (11.5 μm) aluminum backings. This contribution presents the results of a set of measurements of the 242Pu(n, γ) cross section from thermal to 500 keV combining different neutron beams and techniques. The thermal point was determined at the Budapest Research Reactor by means of Neutron Activation Analysis and Prompt Gamma Analysis, and the resolved (1 eV - 4 keV) and unresolved (1 - 500 keV) resonance regions were measured using a set of four Total Energy detectors at the CERN n_TOF-EAR1.
Setup for the measurement of the 235U(n,f) cross section relative to n-p scattering up to 1 GeV
(2020)
The neutron induced fission of 235U is extensively used as a reference for neutron fluence measurements in various applications, ranging from the investigation of the biological effectiveness of high energy neutrons, to the measurement of high energy neutron cross sections of relevance for accelerator driven nuclear systems. Despite its widespread use, no data exist on neutron induced fission of 235U above 200 MeV. The neutron facility n_TOF offers the possibility to improve the situation. The measurement of 235U(n,f) relative to the differential n-p scattering cross-section, was carried out in September 2018 with the aim of providing accurate and precise cross section data in the energy range from 10 MeV up to 1 GeV. In such measurements, Recoil Proton Telescopes (RPTs) are used to measure the neutron flux while the fission events are detected and counted with dedicated detectors. In this paper the measurement campaign and the experimental set-up are illustrated.
The accuracy on neutron capture cross section of fissile isotopes must be improved for the design of future nuclear systems such as Gen-IV reactors and Accelerator Driven Systems. The High Priority Request List of the Nuclear Energy Agency, which lists the most important nuclear data requirements, includes also the neutron capture cross sections of fissile isotopes such as 233,235U and 239,241Pu. A specific experimental setup has been used at the CERN n_TOF facility for the measurement of the neutron capture cross section of 235U by a set of micromegas fission detectors placed inside a segmented BaF2 Total Absorption Calorimeter.
The experimental area 2 (EAR-2) at CERNs neutron time-of-flight facility (n_TOF), which is operational since 2014, is designed and built as a short-distance complement to the experimental area 1 (EAR-1). The Parallel Plate Avalanche Counter (PPAC) monitor experiment was performed to characterize the beam pro↓le and the shape of the neutron 'ux at EAR-2. The prompt γ-flash which is used for calibrating the time-of-flight at EAR-1 is not seen by PPAC at EAR-2, shedding light on the physical origin of this γ-flash.
Monte Carlo (MC) simulations are an essential tool to determine fundamental features of a neutron beam, such as the neutron flux or the γ-ray background, that sometimes can not be measured or at least not in every position or energy range. Until recently, the most widely used MC codes in this field had been MCNPX and FLUKA. However, the Geant4 toolkit has also become a competitive code for the transport of neutrons after the development of the native Geant4 format for neutron data libraries, G4NDL. In this context, we present the Geant4 simulations of the neutron spallation target of the n_TOF facility at CERN, done with version 10.1.1 of the toolkit. The first goal was the validation of the intra-nuclear cascade models implemented in the code using, as benchmark, the characteristics of the neutron beam measured at the first experimental area (EAR1), especially the neutron flux and energy distribution, and the time distribution of neutrons of equal kinetic energy, the so-called Resolution Function. The second goal was the development of a Monte Carlo tool aimed to provide useful calculations for both the analysis and planning of the upcoming measurements at the new experimental area (EAR2) of the facility.
Purpose: The purpose of this paper was to review the available approaches for bone strength assessment, osteoporosis diagnosis and fracture risk prediction, and to provide insights into radiofrequency echographic multi spectrometry (REMS), a non-ionizing axial skeleton technique.
Methods: A working group convened by the European Society for Clinical and Economic Aspects of Osteoporosis and Osteoarthritis met to review the current image-based methods for bone strength assessment and fracture risk estimation, and to discuss the clinical perspectives of REMS.
Results: Areal bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA) is the consolidated indicator for osteoporosis diagnosis and fracture risk assessment. A more reliable fracture risk estimation would actually require an improved assessment of bone strength, integrating also bone quality information. Several different approaches have been proposed, including additional DXA-based parameters, quantitative computed tomography, and quantitative ultrasound. Although each of them showed a somewhat improved clinical performance, none satisfied all the requirements for a widespread routine employment, which was typically hindered by unclear clinical usefulness, radiation doses, limited accessibility, or inapplicability to spine and hip, therefore leaving several clinical needs still unmet. REMS is a clinically available technology for osteoporosis diagnosis and fracture risk assessment through the estimation of BMD on the axial skeleton reference sites. Its automatic processing of unfiltered ultrasound signals provides accurate BMD values in view of fracture risk assessment.
Conclusions: New approaches for improved bone strength and fracture risk estimations are needed for a better management of osteoporotic patients. In this context, REMS represents a valuable approach for osteoporosis diagnosis and fracture risk prediction.
Objective: Management and outcomes of superficial vein thrombosis (SVT) are highly variable and not well described. Therefore, the INvestigating SIGnificant Health TrendS in the management of SVT (INSIGHTS-SVT) study collected prospective data under real life conditions.
Methods: Prospective observational study of objectively confirmed acute isolated SVT. The primary outcome was a composite of symptomatic deep vein thrombosis (DVT), pulmonary embolism (PE), and extension or recurrence of SVT at three months. The primary safety outcome was clinically relevant bleeding.
Results: A total of 1 150 patients were included (mean age 60.2 ± 14.7 years; 64.9% women; mean BMI 29.4 ± 6.3 kg/m2). SVT was below the knee in 54.5%, above the knee in 26.7%, above and below the knee in 18.8%. At baseline, 93.6% received pharmacological treatment (65.7% fondaparinux, 23.2% heparins, 4.3% direct oral anticoagulants [DOACs], 14.5% analgesics), 77.0% compression treatment, and 1.9% surgery; 6.4% did not receive any anticoagulation. The primary outcome occurred in 5.8%; 4.7% had recurrent or extended SVT, 1.7% DVT, and 0.8% PE. Clinically relevant non-major bleeding occurred in 1.2% and major bleeding in 0.3%. Complete clinical recovery of SVT was reported in 708 patients (62.4%). Primary outcome adjusted by propensity score and for treatment duration was lower with fondaparinux compared with low molecular weight heparin (4.4% vs. 9.6%; hazard ratio [HR] 0.51; 95% confidence interval [CI] 0.3 - 0.9; p = .017). On multivariable analysis, associated factors for primary outcome included another SVT prior to the present SVT event (HR 2.3), age per year (HR 0.97), duration of drug treatment per week (HR 0.92), and thrombus length (HR 1.03).
Conclusion: At three month follow up, patients with isolated SVT are at risk of thromboembolic complications (mainly recurrent or extended SVT), despite anticoagulation. In this real life study, about one third had received either heparins, oral anticoagulants, or no anticoagulation.
Background: The development of robotic systems has provided an alternative to frame-based stereotactic procedures. The aim of this experimental phantom study was to compare the mechanical accuracy of the Robotic Surgery Assistant (ROSA) and the Leksell stereotactic frame by reducing clinical and procedural factors to a minimum.
Methods: To precisely compare mechanical accuracy, a stereotactic system was chosen as reference for both methods. A thin layer CT scan with an acrylic phantom fixed to the frame and a localizer enabling the software to recognize the coordinate system was performed. For each of the five phantom targets, two different trajectories were planned, resulting in 10 trajectories. A series of five repetitions was performed, each time based on a new CT scan. Hence, 50 trajectories were analyzed for each method. X-rays of the final cannula position were fused with the planning data. The coordinates of the target point and the endpoint of the robot- or frame-guided probe were visually determined using the robotic software. The target point error (TPE) was calculated applying the Euclidian distance. The depth deviation along the trajectory and the lateral deviation were separately calculated.
Results: Robotics was significantly more accurate, with an arithmetic TPE mean of 0.53 mm (95% CI 0.41–0.55 mm) compared to 0.72 mm (95% CI 0.63–0.8 mm) in stereotaxy (p < 0.05). In robotics, the mean depth deviation along the trajectory was −0.22 mm (95% CI −0.25 to −0.14 mm). The mean lateral deviation was 0.43 mm (95% CI 0.32–0.49 mm). In frame-based stereotaxy, the mean depth deviation amounted to −0.20 mm (95% CI −0.26 to −0.14 mm), the mean lateral deviation to 0.65 mm (95% CI 0.55–0.74 mm).
Conclusion: Both the robotic and frame-based approach proved accurate. The robotic procedure showed significantly higher accuracy. For both methods, procedural factors occurring during surgery might have a more relevant impact on overall accuracy.
Meeting Abstract : 82. Jahresversammlung der Deutschen Gesellschaft für Hals-Nasen-Ohren-Heilkunde, Kopf- und Hals-Chirurgie. Freiburg i. Br., 01.-05.06.2011.
Ca. 3 Millionen Erwachsene in der Bundesrepublik Deutschland leiden unter Tinnitus, wobei eine bei jedem dieser Patienten zur Heilung führende Therapie bisher noch nicht existiert. Ansatzpunkt einer neuartigen Therapie ist die Wiederherstellung des normalen elektrischen Entladungsmusters im Hörnerv mittels elektrischer Stimulation. Hiermit berichten wir über unsere ersten Erfahrungen mit dem Tinnelec, einem Implantat mit einer einzelnen Stimulations-Elektrode die in der Rundfensternische platziert wird.
Zurzeit haben wir 4 einseitig ertaubten Patienten mit Tinnitus auf dem betroffenen Ohr jeweils ein Tinnelec-System implantiert. Die Dauer des Tinnitus betrug mindestens ein Jahr und gängige Tinnitus-Therapien wie z.B. Infusionstherapie waren erfolglos geblieben. Ein psychogener Tinnitus wurde ausgeschlossen. Der durch den Tinnitus verursachte Leidensdruck wurde anhand einer VAS Scala (Visuelle Analog Scala) und eines Tinnitus-Handicap-Inventory (THI) Fragebogens beurteilt. Die Reizapplikation betrug mind. 4 Stunden täglich. Als Stimulationsparameter wurde eine Reizmusterannäherung an den Tinnitus angestrebt.
Bei drei Patienten wurde unter der Stimulation der Tinnitus erträglicher, eine zeitweise komplette Unterdrückung des Tinnitus schon innerhalb der ersten Therapie-Wochen wurde jedoch nur in einem der Fälle berichtet. Diese Ergebnisse wurden auch durch das THI und VAS unterstützt.
Die Tinnelec-Implantation erscheint für Tinnitus Erfolg versprechend zu sein. Weitere Studien bei Tinnitus-Patienten ohne zusätzliche Hörbeeinträchtigung sind jedoch notwendig bis endgültige Schlussfolgerungen betreffend dieses Implantats gezogen werden können. In jedem Fall bleibt die Option einer Cochlea-Implantation im selben Ohr, nach Explantation des Tinnelec, bestehen.
Background: Vitamin D insufficiency has been associated with the occurrence of various types of cancer, but causal relationships remain elusive. We therefore aimed to determine the relationship between genetic determinants of vitamin D serum levels and the risk of developing hepatitis C virus (HCV)-related hepatocellular carcinoma (HCC).
Methodology/Principal Findings: Associations between CYP2R1, GC, and DHCR7 genotypes that are determinants of reduced 25-hydroxyvitamin D (25[OH]D3) serum levels and the risk of HCV-related HCC development were investigated for 1279 chronic hepatitis C patients with HCC and 4325 without HCC, respectively. The well-known associations between CYP2R1 (rs1993116, rs10741657), GC (rs2282679), and DHCR7 (rs7944926, rs12785878) genotypes and 25(OH)D3 serum levels were also apparent in patients with chronic hepatitis C. The same genotypes of these single nucleotide polymorphisms (SNPs) that are associated with reduced 25(OH)D3 serum levels were found to be associated with HCV-related HCC (P = 0.07 [OR = 1.13, 95% CI = 0.99–1.28] for CYP2R1, P = 0.007 [OR = 1.56, 95% CI = 1.12–2.15] for GC, P = 0.003 [OR = 1.42, 95% CI = 1.13–1.78] for DHCR7; ORs for risk genotypes). In contrast, no association between these genetic variations and liver fibrosis progression rate (P>0.2 for each SNP) or outcome of standard therapy with pegylated interferon-α and ribavirin (P>0.2 for each SNP) was observed, suggesting a specific influence of the genetic determinants of 25(OH)D3 serum levels on hepatocarcinogenesis.
Conclusions/Significance: Our data suggest a relatively weak but functionally relevant role for vitamin D in the prevention of HCV-related hepatocarcinogenesis.
Background: Clinical practice guidelines for patients with primary biliary cholangitis (PBC) have been recently revised and implemented for well-established response criteria to standard first-line ursodeoxycholic acid (UDCA) therapy at 12 months after treatment initiation for the early identification of high-risk patients with inadequate treatment responses who may require treatment modification. However, there are only very limited data concerning the real-world clinical management of patients with PBC in Germany. Objective: The aim of this retrospective multicenter study was to evaluate response rates to standard first-line UDCA therapy and subsequent Second-line treatment regimens in a large cohort of well-characterized patients with PBC from 10 independent hepatological referral centers in Germany prior to the introduction of obeticholic acid as a licensed second-line treatment option. Methods: Diagnostic confirmation of PBC, standard first-line UDCA treatment regimens and response rates at 12 months according to Paris-I, Paris-II, and Barcelona criteria, the follow-up cut-off alkaline phosphatase (ALP) ≤ 1.67 × upper limit of normal (ULN) and the normalization of bilirubin (bilirubin ≤ 1 × ULN) were retrospectively examined between June 1986 and March 2017. The management and hitherto applied second-line treatment regimens in patients with an inadequate response to UDCA and subsequent response rates at 12 months were also evaluated. Results: Overall, 480 PBC patients were included in this study. The median UDCA dosage was 13.2 mg UDCA/kg bodyweight (BW)/d. Adequate UDCA treatment response rates according to Paris-I, Paris-II, and Barcelona criteria were observed in 91, 71.3, and 61.3% of patients, respectively. In 83.8% of patients, ALP ≤ 1.67 × ULN were achieved. A total of 116 patients (24.2%) showed an inadequate response to UDCA according to at least one criterion. The diverse second-line treatment regimens applied led to significantly higher response rates according to Paris-II (35 vs. 60%, p = 0.005), Barcelona (13 vs. 34%, p = 0.0005), ALP ≤ 1.67 × ULN and bilirubin ≤ 1 × ULN (52.1 vs. 75%, p = 0.002). The addition of bezafibrates appeared to induce the strongest beneficial effect in this cohort (Paris II: 24 vs. 74%, p = 0.004; Barcelona: 50 vs. 84%, p = 0.046; ALP < 1.67 × ULN and bilirubin ≤ 1 × ULN: 33 vs. 86%, p = 0.001). Conclusion: Our large retrospective multicenter study confirms high response rates following UDCA first-line standard treatment in patients with PBC and highlights the need for close monitoring and early treatment modification in high-risk patients with an insufficient response to UDCA since early treatment modification significantly increases subsequent response rates of these patients.
A wide variety of enzymatic pathways that produce specialized metabolites in bacteria, fungi and plants are known to be encoded in biosynthetic gene clusters. Information about these clusters, pathways and metabolites is currently dispersed throughout the literature, making it difficult to exploit. To facilitate consistent and systematic deposition and retrieval of data on biosynthetic gene clusters, we propose the Minimum Information about a Biosynthetic Gene cluster (MIBiG) data standard.
Background: Malaria remains one of the most serious infections for travellers to tropical countries. Due to the lack of harmonized guidelines a large variety of treatment regimens is used in Europe to treat severe malaria.
Methods: The European Network for Tropical Medicine and Travel Health (TropNet) conducted an 8-year, multicentre, observational study to analyse epidemiology, treatment practices and outcomes of severe malaria in its member sites across Europe. Physicians at participating TropNet centres were asked to report pseudonymized retrospective data from all patients treated at their centre for microscopically confirmed severe Plasmodium falciparum malaria according to the 2006 WHO criteria.
Results: From 2006 to 2014 a total of 185 patients with severe malaria treated in 12 European countries were included. Three patients died, resulting in a 28-day survival rate of 98.4%. The majority of infections were acquired in West Africa (109/185, 59%). The proportion of patients treated with intravenous artesunate increased from 27% in 2006 to 60% in 2013. Altogether, 56 different combinations of intravenous and oral drugs were used across 28 study centres. The risk of acute renal failure (36 vs 17% p = 0.04) or cerebral malaria (54 vs 20%, p = 0.001) was significantly higher in patients ≥60 years than in younger patients. Respiratory distress with the need for mechanical ventilation was significantly associated with the risk of death in the study population (13 vs 0%, p = 0.001). Post-artemisinin delayed haemolysis was reported in 19/70 (27%) patients treated with intravenous artesunate.
Conclusion: The majority of patients with severe malaria in this study were tourists or migrants acquiring the infection in West Africa. Intravenous artesunate is increasingly used for treatment of severe malaria in many European treatment centres and can be given safely to European patients with severe malaria. Patients treated with intravenous artesunate should be followed up to detect and manage late haemolytic events.
Investigators in the cognitive neurosciences have turned to Big Data to address persistent replication and reliability issues by increasing sample sizes, statistical power, and representativeness of data. While there is tremendous potential to advance science through open data sharing, these efforts unveil a host of new questions about how to integrate data arising from distinct sources and instruments. We focus on the most frequently assessed area of cognition - memory testing - and demonstrate a process for reliable data harmonization across three common measures. We aggregated raw data from 53 studies from around the world which measured at least one of three distinct verbal learning tasks, totaling N = 10,505 healthy and brain-injured individuals. A mega analysis was conducted using empirical bayes harmonization to isolate and remove site effects, followed by linear models which adjusted for common covariates. After corrections, a continuous item response theory (IRT) model estimated each individual subject’s latent verbal learning ability while accounting for item difficulties. Harmonization significantly reduced inter-site variance by 37% while preserving covariate effects. The effects of age, sex, and education on scores were found to be highly consistent across memory tests. IRT methods for equating scores across AVLTs agreed with held-out data of dually-administered tests, and these tools are made available for free online. This work demonstrates that large-scale data sharing and harmonization initiatives can offer opportunities to address reproducibility and integration challenges across the behavioral sciences.
A central motivation for the development of x-ray free-electron lasers has been the prospect of time-resolved single-molecule imaging with atomic resolution. Here, we show that x-ray photoelectron diffraction—where a photoelectron emitted after x-ray absorption illuminates the molecular structure from within—can be used to image the increase of the internuclear distance during the x-ray-induced fragmentation of an O2 molecule. By measuring the molecular-frame photoelectron emission patterns for a two-photon sequential K-shell ionization in coincidence with the fragment ions, and by sorting the data as a function of the measured kinetic energy release, we can resolve the elongation of the molecular bond by approximately 1.2 a.u. within the duration of the x-ray pulse. The experiment paves the road toward time-resolved pump-probe photoelectron diffraction imaging at high-repetition-rate x-ray free-electron lasers.
Pathogenic variants in PRRT2, encoding the proline-rich transmembrane protein 2, have been associated with an evolving spectrum of paroxysmal neurologic disorders. Based on a cohort of children with PRRT2-related infantile epilepsy, this study aimed at delineating the broad clinical spectrum of PRRT2-associated phenotypes in these children and their relatives. Only a few recent larger cohort studies are on record and findings from single reports were not confirmed so far. We collected detailed genetic and phenotypic data of 40 previously unreported patients from 36 families. All patients had benign infantile epilepsy and harbored pathogenic variants in PRRT2 (core cohort). Clinical data of 62 family members were included, comprising a cohort of 102 individuals (extended cohort) with PRRT2-associated neurological disease. Additional phenotypes in the cohort of patients with benign sporadic and familial infantile epilepsy consist of movement disorders with paroxysmal kinesigenic dyskinesia in six patients, infantile-onset movement disorders in 2 of 40 individuals, and episodic ataxia after mild head trauma in one girl with bi-allelic variants in PRRT2. The same girl displayed a focal cortical dysplasia upon brain imaging. Familial hemiplegic migraine and migraine with aura were reported in nine families. A single individual developed epilepsy with continuous spikes and waves during sleep. In addition to known variants, we report the novel variant c.843G>T, p.(Trp281Cys) that co-segregated with benign infantile epilepsy and migraine in one family. Our study highlights the variability of clinical presentations of patients harboring pathogenic PRRT2 variants and expands the associated phenotypic spectrum.
Background: Biliary rhabdomyosarcoma (RMS) is the most common biliary tumor in children. The management of affected patients contains unique challenges because of the rarity of this tumor entity and its critical location at the porta hepatis, which can make achievement of a radical resection very difficult.
Methods: In a retrospective chart analysis we analysed children suffering from biliary RMS who were registered in three different CWS trials (CWS-96, CWS-2002P, and SoTiSaR registry).
Results: Seventeen patients (12 female, 5 male) with a median age of 4.3 years were assessed. The median follow-up was 42.2 months (10.7–202.5). The 5-year overall (OS) and event free survival (EFS) rates were 58% (45–71) and 47% (34–50), respectively. Patients > 10 years of age and those with alveolar histology had the worst prognosis (OS 0%). Patients with botryoid histology had an excellent survival (OS 100%) compared to those with non-botryoid histology (OS 38%, 22–54, p = 0.047). Microscopic complete tumor resection was achieved in almost all patients who received initial tumor biopsy followed by chemotherapy and delayed surgery.
Conclusion: Positive predictive factors for survival of children with biliary RMS are age ≤ 10 years and botryoid tumor histology. Primary surgery with intention of tumor resection should be avoided.
The Heidelberg Ion-Beam Therapy Centre (HIT) provides proton, helium, and carbon-ion beams with different energies and intensities for cancer treatment and oxygen-ion beams for experiments. For several experiments and possible future applications, such as helium ion beam radiography, a low-intensity ion beam monitor integrated into the dose delivery feedback system for the accelerator control is a necessary pre-requisite. The updated 2D prototype for this purpose consists of scintillating fibres with enhanced radiation hardness, silicon photomultipliers (SiPMs) to amplify the emitted light, and a dedicated front-end readout system (FERS) to process and record the generated signals. This setup was tested successfully on monitoring ion-beam position and profile horizontally and vertically, as well as the beam intensity, for all four ion types with energies from 50 to 430 MeV/u and intensities from 1E2 to 1E7 ions/s. Additionally, time-of-arrival (ToA) measurements on single ions have been successfully performed for a limited intensity range, allowing for ion tracking in a further update. This will reduce noise, and will also improve the accuracy and usability of ion radiography.
Calibration of TCCON column-averaged CO₂: the first aircraft campaign over European TCCON sites
(2011)
The Total Carbon Column Observing Network (TCCON) is a ground-based network of Fourier Transform Spectrometer (FTS) sites around the globe, where the column abundances of CO2, CH4, N2O, CO and O2 are measured. CO2 is constrained with a precision better than 0.25% (1-σ). To achieve a similarly high accuracy, calibration to World Meteorological Organization (WMO) standards is required. This paper introduces the first aircraft calibration campaign of five European TCCON sites and a mobile FTS instrument. A series of WMO standards in-situ profiles were obtained over European TCCON sites via aircraft and compared with retrievals of CO2 column amounts from the TCCON instruments. The results of the campaign show that the FTS measurements are consistently biased 1.1% ± 0.2% low with respect to WMO standards, in agreement with previous TCCON calibration campaigns. The standard a priori profile for the TCCON FTS retrievals is shown to not add a bias. The same calibration factor is generated using aircraft profiles as a priori and with the TCCON standard a priori. With a calibration to WMO standards, the highly precise TCCON CO2 measurements of total column concentrations provide a suitable database for the calibration and validation of nadir-viewing satellites
The seasonality of transport and mixing of air into the lowermost stratosphere (LMS) is studied using distributions of mean age of air and a~mass balance approach, based on in-situ observations of SF6 and CO2 during the SPURT (Spurenstofftransport in der Tropopausenregion, trace gas transport in the tropopause region) aircraft campaigns. Combining the information of the mean age of air and the water vapour distributions we demonstrate that the tropospheric air transported into the LMS above the extratropical tropopause layer (ExTL) originates predominantly from the tropical tropopause layer (TTL). The concept of our mass balance is based on simultaneous measurements of the two passive tracers and the assumption that transport into the LMS can be described by age spectra which are superposition of two different modes. Based on this concept we conclude that the stratospheric influence on LMS composition is strongest in April with tropospheric fractions (α1) below 20% and that the strongest tropospheric signatures are found in October with (α1 greater than 80%. Beyond the fractions, our mass balance concept allows to calculate the associated transit times for transport of tropospheric air from the tropics into the LMS. The shortest transit times (<0.3 years) are derived for the summer, continuously increasing up to 0.8 years by the end of spring. These findings suggest that strong quasi-horizontal mixing across the weak subtropical jet from summer to mid of autumn and the considerably shorter residual transport time-scales within the lower branch of the Brewer-Dobson circulation in summer than in winter dominates the tropospheric influence in the LMS until the beginning of next year's summer.