Refine
Year of publication
- 2019 (149) (remove)
Language
- English (149)
Has Fulltext
- yes (149)
Is part of the Bibliography
- no (149)
Keywords
Institute
- Physik (144)
- Frankfurt Institute for Advanced Studies (FIAS) (137)
- Informatik (131)
- Medizin (5)
- Biochemie und Chemie (4)
From a global viewpoint, a lot of time is spent within the indoor air compartment of vehicles. A German study on mobility has revealed that, on average, people spend 45 minutes per day inside vehicles. In recent years the number of cars has increased to around 43 million vehicles in private households. This means that more than one car can be used in every household. The ratio has been growing, especially in eastern Germany and rural areas. "Overall and especially outside the cities, the car remains by far number one mode of transport, especially in terms of mileage". Therefore, numerous international studies have addressed different aspects of indoor air hygiene, in the past years. In this paper, meaningful original studies on car indoor air pollution, related to VOCs, COx, PMs, microbials, BFRs, OPFRs, cigarettes, electronic smoking devices, high molecular weight plasticizer, and NOx are summarized in the form of a review. This present review aimed to summarize recently published studies in this important field of environmental medicine and points to the need for further studies with special recommendations for optimizing the interior air hygiene.
Background: Esophageal cancer (EC) is one of the deadliest cancers worldwide. The contemporary strong increase of the adenocarcinomas in Western countries and the high mortality rates require the intensification of prospective multinational studies.
Methods: Therefore, this global health issue has been chosen for the bibliometric review of the global publication output. As source for meta and citation data, the Web of Science has been used and Density Equalizing Maps were applied for visualization.
Results: 17,387 articles on EC could be identified. The years with publication and citation maxima correspond to the appearance of the most prolific articles. China is the most publishing country, followed by Japan and the USA. Germany and the UK ranked 4th and 5th. The analysis of the ratios articles and socio-economic parameters emphasizes the leading position of the Scandinavian countries and Japan. Here, the high-income countries come out on top. The high incidence regions are mainly represented by Chinese and Japanese research. The association of the publication output and the overall research funding could be shown.
Conclusions: A strengthened international network increasingly consisting of the scientifically best positioned countries as well as more of the high incidence countries worldwide is mandatory for future research. The findings deliver scientists, clinicians and decision makers backgrounds for future decisions all over the world.
Selection and prioritization of patients with HCC for LT are based on pretransplant imaging diagnostic, taking the risk of incorrect diagnosis. According to the German waitlist guidelines, imaging has to be reported to the allocation organization (Eurotransplant) and pathology reports have to be submitted thereafter. In order to assess current procedures we performed a retrospective multicenter analysis in all German transplant centers with focus on accuracy of imaging diagnostic and tumor classification. 1168 primary LT for HCC were conducted between 2007 and 2013 in Germany. Patients inside the Milan, UCSF, and up-to-seven criteria were misclassified with definitive histologic results in 18%, 15%, and 11%, respectively. Patients pretransplant outside the Milan, UCSF, and up-to-seven criteria were otherwise misclassified in 34%, 43%, and 41%. Recurrence-free survival correlated with classification by posttransplant histological report, but not pretransplant imaging diagnostic. Univariate analysis revealed tumor size, vascular invasion, and grading as significant parameters for outcome, while tumor grading was the only parameter persisting by multivariate testing. Conclusion. There was a relevant percentage (15-40%) of patients misclassified by imaging diagnosis at a time prior to LI-RADS and guidelines to improve imaging of HCC. Outcome analysis showed a good correlation to histological, in contrast poor correlation to imaging diagnosis, suggesting an adjustment of the LT selection and prioritization criteria.
The inhalation of particulate matter (PM) in second-hand smoke (SHS) is hazardous to health of smokers and non-smokers. Tobacco strength (amount of tar, nicotine, and carbon monoxide) and different additives might have an effect on the amount of PM. This study aimed to investigate the influence of tobacco strength or additives on PM. Four cigarette types of the brand Marlboro with different strengths and with or without additives were analyzed in comparison to the 3R4F reference cigarette. SHS was generated by an automatic environmental tobacco smoke emitter (AETSE) in an enclosed space with a volume of 2.88 m³. PM concentrations (PM10, PM2.5, PM1) were measured with a laser aerosol spectrometer followed by statistical analysis. The two strongest Marlboro brands (Red and Red without additives) showed the highest PM concentrations of all tested cigarettes. The measured mean concentrations Cmean of PM10 increased up to 1458 µg/m³ for the Marlboro Red without additives (PM2.5: 1452 µg/m³, PM1: 1263 µg/m³). The similarly strong Marlboro Red showed very similar PM values. The second strongest type Marlboro Gold showed 36% (PM10, PM2.5) and 32% (PM1) lower values, respectively. The “lightest” type Marlboro Silver Blue showed 54% (PM10, PM2.5) or 50% (PM1) lower PM values. The results indicate that the lower the tar, nicotine, and carbon monoxide amounts, as well as the longer the cigarette filter, the lower are the PM levels. An influence of additives could not be determined.
Objective: Inhaled particulate matter (PM) in secondhand smoke (SHS) is deleterious for smokers and non-smokers. Different additives in cigarettes might effect the amount of PM. This study aimed to assess the influence of additives on the PM emissions from different cigarette types in SHS.
Design: An experimental study of PM measuring in SHS of cigarettes without exposition of any person.
Method: The concentrations of PM (PM10, PM2.5 and PM1) in SHS of four different types of cigarettes of the brand Lucky Strike, two types with additives (Original Red, Original Blue) and two types without additives (Straight Red, Straight Blue), in comparison to the reference cigarette 3R4F were analysed. An automatic environmental tobacco smoke emitter generated SHS in an enclosed space with a volume of 2.88 m3. PM was measured with a laser aerosol spectrometer (Grimm model 1.109). Afterwards, the measuring values of the four Lucky Strike brands and the reference cigarette were statistically evaluated and visualised.
Results: Lucky Strike Straight Blue, a cigarette type without additives and lower tar amount, showed 10% to 25% lower PM mean values compared with the other tested Lucky Strike products, but 21% (PM1) respectively 27% (PM2.5,PM10) higher mean values than the reference cigarette. The PM mean of all measured smoke-free baseline values (clean air) was 1.6 µg/m³. It increased up to about 1800 µg/m³ for the reference cigarette and up to about 3070 µg/m³ for the Lucky Strike Original Blue.
Conclusions: The findings of this study show the massive increase of PM amount by smoking cigarettes in enclosed spaces and suggest that additives in tobacco products increase the PM amount in SHS. For validation, further comparative studies are necessary focusing on the comparison of the PM concentration of cigarettes with and without additives.
Implications: Due to the exposure to SHS, 890 000 people die each year worldwide. PM in SHS endangers the health of both non-smokers and smokers. This study considers the effect of additives like aromatics and humectant agents in cigarettes on PM in SHS. Do additives in tobacco products increase the amount of PM?
We have identified a mistake in how Fig. 1 is referenced in the text of the article Eur. Phys. J. C 77 (2017) no. 8, 569 which affected three paragraphs of the results section. The corrected three paragraphs as well as the unmodified accompanying figure are reproduced in this document with the correct labeling.
In addition, an editing issue led to a missing acknowledgements section. The missing section is reproduced at the end of this document in the manner in which it should have appeared in the published article.
Neutral pion and η meson production in the transverse momentum range 1 < pT < 20 GeV/c have been measured at mid-rapidity by the ALICE experiment at the Large Hadron Collider (LHC) in central and semi-central Pb-Pb collisions at sNN−−−−√ = 2.76 TeV. These results were obtained using the photon conversion method as well as the PHOS and EMCal detectors. The results extend the upper pT reach of the previous ALICE π0 measurements from 12 GeV/c to 20 GeV/c and present the first measurement of η meson production in heavy-ion collisions at the LHC. The η/π0 ratio is similar for the two centralities and reaches at high pT a plateau value of 0.457 ± 0.013stat ± 0.018syst. A suppression of similar magnitude for π0 and η meson production is observed in Pb-Pb collisions with respect to their production in pp collisions scaled by the number of binary nucleon-nucleon collisions. We discuss the results in terms of NLO pQCD predictions and hydrodynamic models. The measurements show a stronger suppression with respect to what was observed at lower center-of-mass energies in the pT range 6 < pT < 10 GeV/c. At pT < 3 GeV/c, hadronization models describe the π0 results while for the η some tension is observed.
ϕ meson measurements provide insight into strangeness production, which is one of the key observables for the hot medium formed in high-energy heavy-ion collisions. ALICE measured ϕ production through its decay in muon pairs in Pb-Pb collisions at sNN−−−√ = 2.76 TeV in the intermediate transverse momentum range 2<pT<5 GeV/c and in the rapidity interval 2.5<y<4. The ϕ yield was measured as a function of the transverse momentum and collision centrality. The nuclear modification factor was obtained as a function of the average number of participating nucleons. Results were compared with the ones obtained via the kaon decay channel in the same pT range at midrapidity. The values of the nuclear modification factor in the two rapidity regions are in agreement within uncertainties.
Measurements of inclusive and direct photon production at mid-rapidity in pp collisions at s√=2.76 and 8 TeV are presented by the ALICE experiment at the LHC. The results are reported in transverse momentum ranges of 0.4<pT<10 GeV/c and 0.3<pT<16 GeV/c, respectively. Photons are detected with the electromagnetic calorimeter~(EMCal) and via reconstruction of e+e− pairs from conversions in the ALICE detector material using the central tracking system. For the final measurement of the inclusive photon spectra the results are combined in the overlapping pT interval of both methods. Direct photon spectra, or their upper limits at 90% C.L. are extracted using the direct photon excess ratio Rγ, which quantifies the ratio of inclusive photons over decay photons generated with a decay-photon simulation. An additional hybrid method, combining photons reconstructed from conversions with those identified in the EMCal, is used for the combination of the direct photon excess ratio Rγ, as well as the extraction of direct photon spectra or their upper limits. While no significant signal of direct photons is seen over the full pT range, Rγ for pT>7 GeV/c is at least one σ above unity and consistent with expectations from next-to-leading order pQCD calculations.
Measurements of anisotropic flow coefficients with two- and multi-particle cumulants for inclusive charged particles in Pb-Pb collisions at sNN−−−√=5.02 and 2.76 TeV are reported in the pseudorapidity range |η|<0.8 and transverse momentum 0.2<pT<50 GeV/c. The full data sample collected by the ALICE detector in 2015 (2010), corresponding to an integrated luminosity of 12.7 (2.0) μb−1 in the centrality range 0-80%, is analysed. Flow coefficients up to the sixth flow harmonic (v6) are reported and a detailed comparison among results at the two energies is carried out. The pT dependence of anisotropic flow coefficients and its evolution with respect to centrality and harmonic number n are investigated. An approximate power-law scaling of the form vn(pT)∼pn/3T is observed for all flow harmonics at low pT (0.2<pT<3 GeV/c). At the same time, the ratios vn/vn/mm are observed to be essentially independent of pT for most centralities up to about pT=10 GeV/c. Analysing the differences among higher-order cumulants of elliptic flow (v2), which have different sensitivities to flow fluctuations, a measurement of the standardised skewness of the event-by-event v2 distribution P(v2) is reported and constraints on its higher moments are provided. The Elliptic Power distribution is used to parametrise P(v2), extracting its parameters from fits to cumulants. The measurements are compared to different model predictions in order to discriminate among initial-state models and to constrain the temperature dependence of the shear viscosity to entropy-density ratio.