Refine
Year of publication
Language
- English (45)
Has Fulltext
- yes (45)
Is part of the Bibliography
- no (45)
Keywords
- LHC (7)
- ALICE (3)
- ALICE experiment (3)
- pp collisions (3)
- Beauty production (2)
- Single electrons (2)
- 900 GeV (1)
- Biomarker (1)
- CVID (1)
- Comparison with QCD (1)
Institute
- Physik (41)
- Frankfurt Institute for Advanced Studies (FIAS) (33)
- Informatik (33)
- Medizin (3)
The ALICE Zero Degree Calorimeter system (ZDC) is composed of two identical sets of calorimeters, placed at opposite sides with respect to the interaction point, 114 meters away from it, complemented by two small forward electromagnetic calorimeters (ZEM). Each set of detectors consists of a neutron (ZN) and a proton (ZP) ZDC. They are placed at zero degrees with respect to the LHC axis and allow to detect particles emitted close to beam direction, in particular neutrons and protons emerging from hadronic heavy-ion collisions (spectator nucleons) and those emitted from electromagnetic processes. For neutrons emitted by these two processes, the ZN calorimeters have nearly 100% acceptance.
During the √sNN = 2.76 TeV Pb-Pb data-taking, the ALICE Collaboration studied forward neutron emission with a dedicated trigger, requiring a minimum energy deposition in at least one of the two ZN. By exploiting also the information of the two ZEM calorimeters it has been possible to separate the contributions of electromagnetic and hadronic processes and to study single neutron vs. multiple neutron emission.
The measured cross sections of single and mutual electromagnetic dissociation of Pb nuclei at √sNN = 2.76 TeV, with neutron emission, are σsingle EMD = 187:4 ± 0.2 (stat.)−11.2+13.2 (syst.) b and σmutual EMD = 5.7 ± 0.1 (stat.) ±0.4 (syst.) b, respectively [1]. This is the first measurement of electromagnetic dissociation of 208Pb nuclei at the LHC energies, allowing a test of electromagnetic dissociation theory in a new energy regime. The experimental results are compared to the predictions from a relativistic electromagnetic dissociation model.
The ALICE Collaboration has made the first measurement at the LHC of J/ψ photoproduction in ultra-peripheral Pb–Pb collisions at sNN=2.76 TeV. The J/ψ is identified via its dimuon decay in the forward rapidity region with the muon spectrometer for events where the hadronic activity is required to be minimal. The analysis is based on an event sample corresponding to an integrated luminosity of about 55 μb−1. The cross section for coherent J/ψ production in the rapidity interval −3.6<y<−2.6 is measured to be dσJ/ψcoh/dy=1.00±0.18(stat)−0.26+0.24(syst) mb. The result is compared to theoretical models for coherent J/ψ production and found to be in good agreement with those models which include nuclear gluon shadowing.
Comprehensive analysis of tumour sub-volumes for radiomic risk modelling in locally advanced HNSCC
(2020)
Simple Summary: Radiomic risk models are usually based on imaging features, which are extracted from the entire gross tumour volume (GTV entire ). This approach does not explicitly consider the complex biological structure of the tumours. Therefore, in this retrospective study, we investigated the prognostic value of radiomic analyses based on different tumour sub-volumes using computed tomography imaging of patients with locally advanced head and neck squamous cell carcinoma who were treated with primary radio-chemotherapy. The GTV entire was cropped by different margins to define the rim and corresponding core sub-volumes of the tumour. Furthermore, the best performing tumour rim sub-volume was extended into surrounding tissue with different margins. As a result, the models based on the 5 mm tumour rim and on the 3 mm extended rim sub-volume showed an improved performance compared to models based on the corresponding tumour core. This indicates that the consideration of tumour sub-volumes may help to improve radiomic risk models.
Abstract: Imaging features for radiomic analyses are commonly calculated from the entire gross tumour volume (GTVentire). However, tumours are biologically complex and the consideration of different tumour regions in radiomic models may lead to an improved outcome prediction. Therefore, we investigated the prognostic value of radiomic analyses based on different tumour sub-volumes using computed tomography imaging of patients with locally advanced head and neck squamous cell carcinoma. The GTVentire was cropped by different margins to define the rim and the corresponding core sub-volumes of the tumour. Subsequently, the best performing tumour rim sub-volume was extended into surrounding tissue with different margins. Radiomic risk models were developed and validated using a retrospective cohort consisting of 291 patients in one of the six Partner Sites of the German Cancer Consortium Radiation Oncology Group treated between 2005 and 2013. The validation concordance index (C-index) averaged over all applied learning algorithms and feature selection methods using the GTVentire achieved a moderate prognostic performance for loco-regional tumour control (C-index: 0.61 ± 0.04 (mean ± std)). The models based on the 5 mm tumour rim and on the 3 mm extended rim sub-volume showed higher median performances (C-index: 0.65 ± 0.02 and 0.64 ± 0.05, respectively), while models based on the corresponding tumour core volumes performed less (C-index: 0.59 ± 0.01). The difference in C-index between the 5 mm tumour rim and the corresponding core volume showed a statistical trend (p = 0.10). After additional prospective validation, the consideration of tumour sub-volumes may be a promising way to improve prognostic radiomic risk models.
Purpose: To develop and validate a CT-based radiomics signature for the prognosis of loco-regional tumour control (LRC) in patients with locally advanced head and neck squamous cell carcinoma (HNSCC) treated by primary radiochemotherapy (RCTx) based on retrospective data from 6 partner sites of the German Cancer Consortium - Radiation Oncology Group (DKTK-ROG).
Material and methods: Pre-treatment CT images of 318 patients with locally advanced HNSCC were collected. Four-hundred forty-six features were extracted from each primary tumour volume and then filtered through stability analysis and clustering. First, a baseline signature was developed from demographic and tumour-associated clinical parameters. This signature was then supplemented by CT imaging features. A final signature was derived using repeated 3-fold cross-validation on the discovery cohort. Performance in external validation was assessed by the concordance index (C-Index). Furthermore, calibration and patient stratification in groups with low and high risk for loco-regional recurrence were analysed.
Results: For the clinical baseline signature, only the primary tumour volume was selected. The final signature combined the tumour volume with two independent radiomics features. It achieved moderately good discriminatory performance (C-Index [95% confidence interval]: 0.66 [0.55–0.75]) on the validation cohort along with significant patient stratification (p = 0.005) and good calibration.
Conclusion: We identified and validated a clinical-radiomics signature for LRC of locally advanced HNSCC using a multi-centric retrospective dataset. Prospective validation will be performed on the primary cohort of the HNprädBio trial of the DKTK-ROG once follow-up is completed.
Long-range angular correlations on the near and away side in p–Pb collisions at √sNN=5.02 TeV
(2013)
Angular correlations between charged trigger and associated particles are measured by the ALICE detector in p–Pb collisions at a nucleon–nucleon centre-of-mass energy of 5.02 TeV for transverse momentum ranges within 0.5<pT,assoc<pT,trig<4 GeV/c. The correlations are measured over two units of pseudorapidity and full azimuthal angle in different intervals of event multiplicity, and expressed as associated yield per trigger particle. Two long-range ridge-like structures, one on the near side and one on the away side, are observed when the per-trigger yield obtained in low-multiplicity events is subtracted from the one in high-multiplicity events. The excess on the near-side is qualitatively similar to that recently reported by the CMS Collaboration, while the excess on the away-side is reported for the first time. The two-ridge structure projected onto azimuthal angle is quantified with the second and third Fourier coefficients as well as by near-side and away-side yields and widths. The yields on the near side and on the away side are equal within the uncertainties for all studied event multiplicity and pT bins, and the widths show no significant evolution with event multiplicity or pT. These findings suggest that the near-side ridge is accompanied by an essentially identical away-side ridge.