Refine
Year of publication
Has Fulltext
- yes (26)
Is part of the Bibliography
- no (26)
Keywords
- Contact Ion Pairs (2)
- ESR/ENDOR Spectra (2)
- Experimental nuclear physics (2)
- Experimental particle physics (2)
- Acoustics (1)
- CVID (1)
- Cancer detection and diagnosis (1)
- Capnography (1)
- Cyclic Voltammetry (1)
- Cytology (1)
Institute
- Medizin (15)
- Physik (8)
- Frankfurt Institute for Advanced Studies (FIAS) (7)
- Informatik (4)
- Biochemie und Chemie (3)
- Informatik und Mathematik (2)
Standard monitoring of heart rate, blood pressure and arterial oxygen saturation during endoscopy is recommended by current guidelines on procedural sedation. A number of studies indicated a reduction of hypoxic (art. oxygenation < 90% for > 15 s) and severe hypoxic events (art. oxygenation < 85%) by additional use of capnography. Therefore, U.S. and the European guidelines comment that additional capnography monitoring can be considered in long or deep sedation. Integrated Pulmonary Index® (IPI) is an algorithm-based monitoring parameter that combines oxygenation measured by pulse oximetry (art. oxygenation, heart rate) and ventilation measured by capnography (respiratory rate, apnea > 10 s, partial pressure of end-tidal carbon dioxide [PetCO2]). The aim of this paper was to analyze the value of IPI as parameter to monitor the respiratory status in patients receiving propofol sedation during PEG-procedure. Patients reporting for PEG-placement under sedation were randomized 1:1 in either standard monitoring group (SM) or capnography monitoring group including IPI (IM). Heart rate, blood pressure and arterial oxygen saturation were monitored in SM. In IM additional monitoring was performed measuring PetCO2, respiratory rate and IPI. Capnography and IPI values were recorded for all patients but were only visible to the endoscopic team for the IM-group. IPI values range between 1 and 10 (10 = normal; 8–9 = within normal range; 7 = close to normal range, requires attention; 5–6 = requires attention and may require intervention; 3–4 = requires intervention; 1–2 requires immediate intervention). Results on capnography versus standard monitoring of the same study population was published previously. A total of 147 patients (74 in SM and 73 in IM) were included in the present study. Hypoxic events occurred in 62 patients (42%) and severe hypoxic events in 44 patients (29%), respectively. Baseline characteristics were equally distributed in both groups. IPI = 1, IPI < 7 as well as the parameters PetCO2 = 0 mmHg and apnea > 10 s had a high sensitivity for hypoxic and severe hypoxic events, respectively (IPI = 1: 81%/81% [hypoxic/severe hypoxic event], IPI < 7: 82%/88%, PetCO2: 69%/68%, apnea > 10 s: 84%/84%). All four parameters had a low specificity for both hypoxic and severe hypoxic events (IPI = 1: 13%/12%, IPI < 7: 7%/7%, PetCO2: 29%/27%, apnea > 10 s: 7%/7%). In multivariate analysis, only SM and PetCO2 = 0 mmHg were independent risk factors for hypoxia. IPI (IPI = 1 and IPI < 7) as well as the individual parameters PetCO2 = 0 mmHg and apnea > 10 s allow a fast and convenient conclusion on patients’ respiratory status in a morbid patient population. Sensitivity is good for most parameters, but specificity is poor. In conclusion, IPI can be a useful metric to assess respiratory status during propofol-sedation in PEG-placement. However, IPI was not superior to PetCO2 and apnea > 10 s.
Background: The development of robotic systems has provided an alternative to frame-based stereotactic procedures. The aim of this experimental phantom study was to compare the mechanical accuracy of the Robotic Surgery Assistant (ROSA) and the Leksell stereotactic frame by reducing clinical and procedural factors to a minimum.
Methods: To precisely compare mechanical accuracy, a stereotactic system was chosen as reference for both methods. A thin layer CT scan with an acrylic phantom fixed to the frame and a localizer enabling the software to recognize the coordinate system was performed. For each of the five phantom targets, two different trajectories were planned, resulting in 10 trajectories. A series of five repetitions was performed, each time based on a new CT scan. Hence, 50 trajectories were analyzed for each method. X-rays of the final cannula position were fused with the planning data. The coordinates of the target point and the endpoint of the robot- or frame-guided probe were visually determined using the robotic software. The target point error (TPE) was calculated applying the Euclidian distance. The depth deviation along the trajectory and the lateral deviation were separately calculated.
Results: Robotics was significantly more accurate, with an arithmetic TPE mean of 0.53 mm (95% CI 0.41–0.55 mm) compared to 0.72 mm (95% CI 0.63–0.8 mm) in stereotaxy (p < 0.05). In robotics, the mean depth deviation along the trajectory was −0.22 mm (95% CI −0.25 to −0.14 mm). The mean lateral deviation was 0.43 mm (95% CI 0.32–0.49 mm). In frame-based stereotaxy, the mean depth deviation amounted to −0.20 mm (95% CI −0.26 to −0.14 mm), the mean lateral deviation to 0.65 mm (95% CI 0.55–0.74 mm).
Conclusion: Both the robotic and frame-based approach proved accurate. The robotic procedure showed significantly higher accuracy. For both methods, procedural factors occurring during surgery might have a more relevant impact on overall accuracy.
In our Galaxy, light antinuclei composed of antiprotons and antineutrons can be produced through high-energy cosmic-ray collisions with the interstellar medium or could also originate from the annihilation of dark-matter particles that have not yet been discovered. On Earth, the only way to produce and study antinuclei with high precision is to create them at high-energy particle accelerators. Although the properties of elementary antiparticles have been studied in detail, the knowledge of the interaction of light antinuclei with matter is limited. We determine the disappearance probability of 3He¯¯¯¯¯¯ when it encounters matter particles and annihilates or disintegrates within the ALICE detector at the Large Hadron Collider. We extract the inelastic interaction cross section, which is then used as input to calculations of the transparency of our Galaxy to the propagation of 3He¯¯¯¯¯¯ stemming from dark-matter annihilation and cosmic-ray interactions within the interstellar medium. For a specific dark-matter profile, we estimate a transparency of about 50%, whereas it varies with increasing 3He¯¯¯¯¯¯ momentum from 25% to 90% for cosmic-ray sources. The results indicate that 3He¯¯¯¯¯¯ nuclei can travel long distances in the Galaxy, and can be used to study cosmic-ray interactions and dark-matter annihilation.
Antimatter particles such as positrons and antiprotons abound in the cosmos. Much less common are light antinuclei, composed of antiprotons and antineutrons, which can be produced in our galaxy via high-energy cosmic-ray collisions with the interstellar medium or could also originate from the annihilation of the still undiscovered dark-matter particles. On Earth, the only way to produce and study antinuclei with high precision is to create them at high-energy particle accelerators like the Large Hadron Collider (LHC). Though the properties of elementary antiparticles have been studied in detail, knowledge of the interaction of light antinuclei with matter is rather limited. This work focuses on the determination of the disappearance probability of \ahe\ when it encounters matter particles and annihilates or disintegrates. The material of the ALICE detector at the LHC serves as a target to extract the inelastic cross section for \ahe\ in the momentum range of 1.17≤p<10 GeV/c. This inelastic cross section is measured for the first time and is used as an essential input to calculations of the transparency of our galaxy to the propagation of 3He¯¯¯¯¯¯ stemming from dark-matter decays and cosmic-ray interactions within the interstellar medium. A transparency of about 50% is estimated using the GALPROP program for a specific dark-matter profile and a standard set of propagation parameters. For cosmic-ray sources, the obtained transparency with the same propagation scheme varies with increasing 3He¯¯¯¯¯¯ momentum from 25% to 90%. The absolute uncertainties associated to the 3He¯¯¯¯¯¯ inelastic cross section measurements are of the order of 10%−15%. The reported results indicate that 3He¯¯¯¯¯¯ nuclei can travel long distances in the galaxy, and can be used to study cosmic-ray interactions and dark-matter decays.
The structurally different radical anions M⊖ of peralkylated 1-sila-2,5-diazacyclopentane-3,4-dithione and of tetrakis(isopropylthio)-p-benzoquinone are generated by reduction with potassium/2.2.2-cryptand under aprotic conditions in THF solution. On addition of Li⊕B(C6H5)4⊖, both form hitherto elusive sulfur-containing contact ion pairs, which are characterized by their ESR/ENDOR spectra.
Background and Aims: In patients with advanced liver cirrhosis due to chronic hepatitis C virus (HCV) infection antiviral therapy with peginterferon and ribavirin is feasible in selected cases only due to potentially life-threatening side effects. However, predictive factors associated with hepatic decompensation during antiviral therapy are poorly defined.
Methods: In a retrospective cohort study, 68 patients with HCV-associated liver cirrhosis (mean MELD score 9.18±2.72) were treated with peginterferon and ribavirin. Clinical events indicating hepatic decompensation (onset of ascites, hepatic encephalopathy, upper gastrointestinal bleeding, hospitalization) as well as laboratory data were recorded at baseline and during a follow up period of 72 weeks after initiation of antiviral therapy. To monitor long term sequelae of end stage liver disease an extended follow up for HCC development, transplantation and death was applied (240weeks, ±SD 136weeks).
Results: Eighteen patients (26.5%) achieved a sustained virologic response. During the observational period a hepatic decompensation was observed in 36.8%. Patients with hepatic decompensation had higher MELD scores (10.84 vs. 8.23, p<0.001) and higher mean bilirubin levels (26.74 vs. 14.63 µmol/l, p<0.001), as well as lower serum albumin levels (38.2 vs. 41.1 g/l, p = 0.015), mean platelets (102.64 vs. 138.95/nl, p = 0.014) and mean leukocytes (4.02 vs. 5.68/nl, p = 0.002) at baseline as compared to those without decompensation. In the multivariate analysis the MELD score remained independently associated with hepatic decompensation (OR 1.56, 1.18–2.07; p = 0.002). When the patients were grouped according to their baseline MELD scores, hepatic decompensation occurred in 22%, 59%, and 83% of patients with MELD scores of 6–9, 10–13, and >14, respectively. Baseline MELD score was significantly associated with the risk for transplantation/death (p<0.001).
Conclusions: Our data suggest that the baseline MELD score predicts the risk of hepatic decompensation during antiviral therapy and thus contributes to decision making when antiviral therapy is discussed in HCV patients with advanced liver cirrhosis.