Refine
Year of publication
Document Type
- Article (35)
- Preprint (6)
- Contribution to a Periodical (1)
Has Fulltext
- yes (42)
Is part of the Bibliography
- no (42)
Keywords
- LHC (6)
- ALICE (3)
- Computed tomography (3)
- ALICE experiment (2)
- Bone density (2)
- Osteoporosis (2)
- pp collisions (2)
- 900 GeV (1)
- Anterior cruciate ligament (1)
- Beauty production (1)
Institute
- Informatik (35)
- Physik (31)
- Frankfurt Institute for Advanced Studies (FIAS) (30)
- Medizin (8)
- Exzellenzcluster Makromolekulare Komplexe (1)
- Präsidium (1)
The ALICE Zero Degree Calorimeter system (ZDC) is composed of two identical sets of calorimeters, placed at opposite sides with respect to the interaction point, 114 meters away from it, complemented by two small forward electromagnetic calorimeters (ZEM). Each set of detectors consists of a neutron (ZN) and a proton (ZP) ZDC. They are placed at zero degrees with respect to the LHC axis and allow to detect particles emitted close to beam direction, in particular neutrons and protons emerging from hadronic heavy-ion collisions (spectator nucleons) and those emitted from electromagnetic processes. For neutrons emitted by these two processes, the ZN calorimeters have nearly 100% acceptance.
During the √sNN = 2.76 TeV Pb-Pb data-taking, the ALICE Collaboration studied forward neutron emission with a dedicated trigger, requiring a minimum energy deposition in at least one of the two ZN. By exploiting also the information of the two ZEM calorimeters it has been possible to separate the contributions of electromagnetic and hadronic processes and to study single neutron vs. multiple neutron emission.
The measured cross sections of single and mutual electromagnetic dissociation of Pb nuclei at √sNN = 2.76 TeV, with neutron emission, are σsingle EMD = 187:4 ± 0.2 (stat.)−11.2+13.2 (syst.) b and σmutual EMD = 5.7 ± 0.1 (stat.) ±0.4 (syst.) b, respectively [1]. This is the first measurement of electromagnetic dissociation of 208Pb nuclei at the LHC energies, allowing a test of electromagnetic dissociation theory in a new energy regime. The experimental results are compared to the predictions from a relativistic electromagnetic dissociation model.
Mathematical modeling of the molecular switch of TNFR1-mediated signaling pathways using Petri nets
(2021)
The paper describes a mathematical model of the molecular switch of cell survival, apoptosis, and necroptosis in cellular signaling pathways initiated by tumor necrosis factor 1. Based on experimental findings in the current literature, we constructed a Petri net model in terms of detailed molecular reactions for the molecular players, protein complexes, post-translational modifications, and cross talk. The model comprises 118 biochemical entities, 130 reactions, and 299 connecting edges. Applying Petri net analysis techniques, we found 279 pathways describing complete signal flows from receptor activation to cellular response, representing the combinatorial diversity of functional pathways.120 pathways steered the cell to survival, whereas 58 and 35 pathways led to apoptosis and necroptosis, respectively. For 65 pathways, the triggered response was not deterministic, leading to multiple possible outcomes. Based on the Petri net, we investigated the detailed in silico knockout behavior and identified important checkpoints of the TNFR1 signaling pathway in terms of ubiquitination within complex I and the gene expression dependent on NF-κB, which controls the caspase activity in complex II and apoptosis induction.
Bioinformatics analysis quantifies neighborhood preferences of cancer cells in Hodgkin lymphoma
(2017)
Motivation Hodgkin lymphoma is a tumor of the lymphatic system and represents one of the most frequent lymphoma in the Western world. It is characterized by Hodgkin cells and Reed-Sternberg cells, which exhibit a broad morphological spectrum. The cells are visualized by immunohistochemical staining of tissue sections. In pathology, tissue images are mainly manually evaluated, relying on the expertise and experience of pathologists. Computational quantification methods become more and more essential to evaluate tissue images. In particular, the distribution of cancer cells is of great interest.
Results Here, we systematically quantified and investigated cancer cell properties and their spatial neighborhood relations by applying statistical analyses to whole slide images of Hodgkin lymphoma and lymphadenitis, which describes a non-cancerous inflammation of the lymph node. We differentiated cells by their morphology and studied the spatial neighborhood relation of more than 400,000 immunohistochemically stained cells. We found that, according to their morphological features, the cells exhibited significant preferences for and aversions to cells of specific profiles as nearest neighbor. We quantified differences between Hodgkin lymphoma and lymphadenitis concerning the neighborhood relations of cells and the sizes of cells. The approach can easily be applied to other cancer types.
isiKnock is a new software that automatically conducts in silico knockouts for mathematical models of biochemical pathways. The software allows for the prediction of the behavior of biological systems after single or multiple knockout. The implemented algorithm applies transition invariants and the novel concept of Manatee invariants. A knockout matrix visualizes the results. The tool enables the analysis of dependencies, for example, in signal flows from the receptor activation to the cell response at steady state.
Rationale and Objectives: Lumbar disk degeneration is a common condition contributing significantly to back pain. The objective of the study was to evaluate the potential of dual-energy CT (DECT)-derived collagen maps for the assessment of lumbar disk degeneration.
Patients and Methods: We conducted a retrospective analysis of 127 patients who underwent dual-source DECT and MRI of the lumbar spine between 07/2019 and 10/2022. The level of lumbar disk degeneration was categorized by three radiologists as follows: no/mild (Pfirrmann 1&2), moderate (Pfirrmann 3&4), and severe (Pfirrmann 5). Recall (sensitivity) and accuracy of DECT collagen maps were calculated. Intraclass correlation coefficient (ICC) was used to evaluate inter-reader reliability. Subjective evaluations were performed using 5-point Likert scales for diagnostic confidence and image quality.
Results: We evaluated a total of 762 intervertebral disks from 127 patients (median age, 69.7 (range, 23.0–93.7), female, 56). MRI identified 230 non/mildly degenerated disks (30.2%), 484 moderately degenerated disks (63.5%), and 48 severely degenerated disks (6.3%). DECT collagen maps yielded an overall accuracy of 85.5% (1955/2286). Recall (sensitivity) was 79.3% (547/690) for the detection of no/mild lumbar disk degeneration, 88.7% (1288/1452) for the detection of moderate disk degeneration, and 83.3% (120/144) for the detection of severe disk degeneration (ICC = 0.9). Subjective evaluations of DECT collagen maps showed high diagnostic confidence (median 4) and good image quality (median 4).
Conclusion: The use of DECT collagen maps to distinguish different stages of lumbar disk degeneration may have clinical significance in the early diagnosis of disk-related pathologies in patients with contraindications for MRI or in cases of unavailability of MRI.
Rationale and Objectives: Bone non-union is a serious complication of distal radius fractures (DRF) that can result in functional limitations and persistent pain. However, no accepted method has been established to identify patients at risk of developing bone non-union yet. This study aimed to compare various CT-derived metrics for bone mineral density (BMD) assessment to identify predictive values for the development of bone non-union.
Materials and Methods: CT images of 192 patients with DRFs who underwent unenhanced dual-energy CT (DECT) of the distal radius between 03/2016 and 12/2020 were retrospectively identified. Available follow-up imaging and medical health records were evaluated to determine the occurrence of bone non-union. DECT-based BMD, trabecular Hounsfield unit (HU), cortical HU and cortical thickness ratio were measured in normalized non-fractured segments of the distal radius.
Results: Patients who developed bone non-union were significantly older (median age 72 years vs. 54 years) and had a significantly lower DECT-based BMD (median 68.1 mg/cm3 vs. 94.6 mg/cm3, p < 0.001). Other metrics (cortical thickness ratio, cortical HU, trabecular HU) showed no significant differences. ROC and PR curve analyses confirmed the highest diagnostic accuracy for DECT-based BMD with an area under the curve (AUC) of 0.83 for the ROC curve and an AUC of 0.46 for the PR curve. In logistic regression models, DECT-based BMD was the sole metric significantly associated with bone non-union.
Conclusion: DECT-derived metrics can accurately predict bone non-union in patients who sustained DRF. The diagnostic performance of DECT-based BMD is superior to that of HU-based metrics and cortical thickness ratio.
Highlights
• Early reconstruction of injured cruciate ligaments improves functional outcomes.
• Modern CT imaging can be used to rapidly identify patients with injury to the cruciate ligaments and streamline therapeutic pathways.
• Dual-energy CT demonstrates superior diagnostic accuracy compared to single-energy CT.
Abstract
Background: This study aimed to evaluate the clinical utility of modern single and dual-energy computed tomography (CT) for assessing the integrity of the cruciate ligaments in patients that sustained acute trauma.
Methods: Patients who underwent single- or dual-energy CT followed by 3 Tesla magnetic resonance imaging (MRI) or knee joint arthroscopy between 01/2016 and 12/2022 were included in this retrospective, monocentric study. Three radiologists specialized in musculoskeletal imaging independently evaluated all CT images for the presence of injury to the cruciate ligaments. An MRI consensus reading of two experienced readers and arthroscopy provided the reference standard. Diagnostic accuracy parameters and area under the receiver operator characteristic curve (AUC) were the primary metrics for diagnostic performance.
Results: CT images of 204 patients (median age, 49 years; IQR 36 – 64; 113 males) were evaluated. Dual-energy CT yielded significantly higher diagnostic accuracy and AUC for the detection of injury to the anterior (94% [240/255] vs 75% [266/357] and 0.89 vs 0.66) and posterior cruciate ligaments (95% [243/255] vs 87% [311/357] and 0.90 vs 0.61) compared to single-energy CT (all parameters, p <.005). Diagnostic confidence and image quality were significantly higher in dual-energy CT compared to single-energy CT (all parameters, p <.005).
Conclusions: Modern dual-energy CT is readily available and can serve as a screening tool for detecting or excluding cruciate ligament injuries in patients with acute trauma. Accurate diagnosis of cruciate ligament injuries is crucial to prevent adverse outcomes, including delayed treatment, chronic instability, or long-term functional limitations.
Background: Dual-energy CT (DECT)-derived bone mineral density (BMD) of the distal radius and other CT-derived metrics related to bone health have been suggested for opportunistic osteoporosis screening and risk evaluation for sustaining distal radius fractures (DRFs).
Methods: The distal radius of patients who underwent DECT between 01/2016 and 08/2021 was retrospectively analyzed. Cortical Hounsfield Unit (HU), trabecular HU, cortical thickness, and DECT-based BMD were acquired from a non-fractured, metaphyseal area in all examinations. Receiver-operating characteristic (ROC) analysis was conducted to determine the area under the curve (AUC) values for predicting DRFs based on DECT-derived BMD, HU values, and cortical thickness. Logistic regression models were then employed to assess the associations of these parameters with the occurrence of DRFs.
Results: In this study, 263 patients (median age: 52 years; interquartile range: 36–64; 132 women; 192 fractures) were included. ROC curve analysis revealed a higher area under the curve (AUC) value for DECT-derived BMD compared to cortical HU, trabecular HU, and cortical thickness (0.91 vs. 0.61, 0.64, and 0.69, respectively; p <.001). Logistic regression models confirmed the association between lower DECT-derived BMD and the occurrence of DRFs (Odds Ratio, 0.83; p <.001); however, no influence was observed for cortical HU, trabecular HU, or cortical thickness.
Conclusions: DECT can be used to assess the BMD of the distal radius without dedicated equipment such as calibration phantoms to increase the detection rates of osteoporosis and stratify the individual risk to sustain DRFs. In contrast, assessing HU-based values and cortical thickness does not provide clinical benefit.
The ALICE Collaboration reports the measurement of the relative J/ψ yield as a function of charged particle pseudorapidity density dNch/dη in pp collisions at √s=7 TeV at the LHC. J/ψ particles are detected for pt>0, in the rapidity interval |y|<0.9 via decay into e+e−, and in the interval 2.5<y<4.0 via decay into μ+μ− pairs. An approximately linear increase of the J/ψ yields normalized to their event average (dNJ/ψ/dy)/〈dNJ/ψ/dy〉 with (dNch/dη)/〈dNch/dη〉 is observed in both rapidity ranges, where dNch/dη is measured within |η|<1 and pt>0. In the highest multiplicity interval with 〈dNch/dη(bin)〉=24.1, corresponding to four times the minimum bias multiplicity density, an enhancement relative to the minimum bias J/ψ yield by a factor of about 5 at 2.5<y<4 (8 at |y|<0.9) is observed.
The ALICE experiment has measured the inclusive J/ψ production in Pb-Pb collisions at sNN−−−√=2.76 TeV down to zero transverse momentum in the rapidity range 2.5<y<4. A suppression of the inclusive J/ψ yield in Pb-Pb is observed with respect to the one measured in pp collisions scaled by the number of binary nucleon-nucleon collisions. The nuclear modification factor, integrated over the 0-80% most central collisions, is 0.545±0.032(stat.)±0.083(syst.) and does not exhibit a significant dependence on the collision centrality. These features appear significantly different from measurements at lower collision energies. Models including J/ψ production from charm quarks in a deconfined partonic phase can describe our data.