Refine
Year of publication
Language
- English (79)
Has Fulltext
- yes (79)
Is part of the Bibliography
- no (79)
Keywords
- LHC (6)
- ALICE (3)
- ALICE experiment (2)
- pp collisions (2)
- 900 GeV (1)
- Allergen immunotherapy (1)
- Allergoid (1)
- Beauty production (1)
- Comparison with QCD (1)
- Cumulative dose (1)
- Curvilinear dose response (1)
- Electron-pion identification (1)
- Femtoscopy (1)
- Fibre/foam sandwich radiator (1)
- Genetics research (1)
- Grass pollen (1)
- HBT (1)
- Hadron production (1)
- Hadronization (1)
- Heavy Ions (1)
- Heavy flavor production (1)
- Heavy flavour production (1)
- Heavy ion collisions (1)
- Heavy-ion collisions (1)
- Inclusive spectra (1)
- Intensity interferometry (1)
- Ionisation energy loss (1)
- Jets (1)
- Mid-rapidity (1)
- Multi-strange baryons (1)
- Multi-wire proportional drift chamber (1)
- Net-charge correlations (1)
- Net-charge fluctuations (1)
- Neural network (1)
- Nuclear modification factor (1)
- PYTHIA (1)
- Pb–Pb (1)
- Predictive markers (1)
- Proton–proton (1)
- Radiotherapy (1)
- Single electrons (1)
- Single muons (1)
- Surgical oncology (1)
- TR (1)
- Tracking (1)
- Transition radiation detector (1)
- Transverse momentum (1)
- Trigger (1)
- Xenon-based gas mixture (1)
- allergen immunotherapy (1)
- birch pollen allergoid (1)
- cumulative dose (1)
- dE/dx (1)
- dose response curve (1)
- ectosomes (1)
- exosomes (1)
- extracellular vesicles (1)
- guidelines (1)
- microparticles (1)
- microvesicles (1)
- minimal information requirements (1)
- reproducibility (1)
- rigor (1)
- spectra (1)
- standardization (1)
- √sN N = 2.76 TeV (1)
Institute
- Physik (70)
- Frankfurt Institute for Advanced Studies (FIAS) (23)
- Informatik (21)
- Medizin (4)
- Georg-Speyer-Haus (1)
- Geowissenschaften (1)
We report results on the ratio of midrapidity antiproton-to-proton yields in Au+Au collisions at sqrt[sNN] = 130 GeV per nucleon pair as measured by the STAR experiment at RHIC. Within the rapidity and transverse momentum range of | y|<0.5 and 0.4<pt<1.0 GeV/c, the ratio is essentially independent of either transverse momentum or rapidity, with an average of 0.65±0.01(stat)±0.07(syst) for minimum bias collisions. Within errors, no strong centrality dependence is observed. The results indicate that at this RHIC energy, although the p-p-bar pair production becomes important at midrapidity, a significant excess of baryons over antibaryons is still present.
Mapping cortical brain asymmetry in 17,141 healthy individuals worldwide via the ENIGMA Consortium
(2017)
Purpose: Preoperative (neoadjuvant) chemoradiotherapy (CRT) and total mesorectal excision is the standard treatment for rectal cancer patients (UICC stage II/III). Up to one-third of patients treated with CRT achieve a pathological complete response (pCR). These patients could be spared from surgery and its associated morbidity and mortality, and assigned to a “watch and wait” strategy. However, reliably identifying pCR based on clinical or imaging parameters remains challenging.
Experimental design: We generated gene-expression profiles of 175 patients with locally advanced rectal cancer enrolled in the CAO/ARO/AIO-94 and -04 trials. One hundred and sixty-one samples were used for building, training and validating a predictor of pCR using a machine learning algorithm. The performance of the classifier was validated in three independent cohorts, comprising 76 patients from (i) the CAO/ARO/AIO-94 and -04 trials (n = 14), (ii) a publicly available dataset (n = 38) and (iii) in 24 prospectively collected samples from the TransValid A trial.
Results: A 21-transcript signature yielded the best classification of pCR in 161 patients (Sensitivity: 0.31; AUC: 0.81), when not allowing misclassification of non-complete-responders (False-positive rate = 0). The classifier remained robust when applied to three independent datasets (n = 76).
Conclusion: The classifier can identify >1/3 of rectal cancer patients with a pCR while never classifying patients with an incomplete response as having pCR. Importantly, we could validate this finding in three independent datasets, including a prospectively collected cohort. Therefore, this classifier could help select rectal cancer patients for a “watch and wait” strategy.
Translational relevance: Forgoing surgery with its associated side effects could be an option for rectal cancer patients if the prediction of a pathological complete response (pCR) after preoperative chemoradiotherapy would be possible. Based on gene-expression profiles of 161 patients a classifier was developed and validated in three independent datasets (n = 76), identifying over 1/3 of patients with pCR, while never misclassifying a non-complete-responder. Therefore, the classifier can identify patients suited for “watch and wait”.
In situ measurements of ice crystal size distributions in tropical upper troposphere/lower stratosphere (UT/LS) clouds were performed during the SCOUT-AMMA campaign over West Africa in August 2006. The cloud properties were measured with a Forward Scattering Spectrometer Probe (FSSP-100) and a Cloud Imaging Probe (CIP) operated aboard the Russian high altitude research aircraft M-55 Geophysica with the mission base in Ouagadougou, Burkina Faso. A total of 117 ice particle size distributions were obtained from the measurements in the vicinity of Mesoscale Convective Systems (MCS). Two to four modal lognormal size distributions were fitted to the average size distributions for different potential temperature bins. The measurements showed proportionately more large ice particles compared to former measurements above maritime regions. With the help of trace gas measurements of NO, NOy, CO2, CO, and O3 and satellite images, clouds in young and aged MCS outflow were identified. These events were observed at altitudes of 11.0 km to 14.2 km corresponding to potential temperature levels of 346 K to 356 K. In a young outflow from a developing MCS ice crystal number concentrations of up to (8.3 ± 1.6) cm−3 and rimed ice particles with maximum dimensions exceeding 1.5 mm were found. A maximum ice water content of 0.05 g m−3 was observed and an effective radius of about 90 μm. In contrast the aged outflow events were more diluted and showed a maximum number concentration of 0.03 cm−3, an ice water content of 2.3 × 10−4 g m−3, an effective radius of about 18 μm, while the largest particles had a maximum dimension of 61 μm.
Close to the tropopause subvisual cirrus were encountered four times at altitudes of 15 km to 16.4 km. The mean ice particle number concentration of these encounters was 0.01 cm−3 with maximum particle sizes of 130 μm, and the mean ice water content was about 1.4 × 10−4 g m−3. All known in situ measurements of subvisual tropopause cirrus are compared and an exponential fit on the size distributions is established for modelling purposes.
A comparison of aerosol to ice crystal number concentrations, in order to obtain an estimate on how many ice particles may result from activation of the present aerosol, yielded low ratios for the subvisual cirrus cases of roughly one cloud particle per 30 000 aerosol particles, while for the MCS outflow cases this resulted in a high ratio of one cloud particle per 300 aerosol particles.
Background: The Birch Allergoid, Tyrosine Adsorbate, Monophosphoryl Lipid A (POLLINEX® Quattro Plus 1.0 ml Birch 100%) is an effective, well‐tolerated short course subcutaneous immunotherapy. We performed 2 phase II studies to determine its optimal cumulative dose.
Methods: The studies were conducted in Germany, Austria and Poland (EudraCT numbers: 2012‐004336‐28 PQBirch203 and 2015‐000984‐15 PQBirch204) using a wide range of cumulative doses. In both studies, subjects were administered 6 therapy injections weekly outside the pollen season. Conjunctival Provocation Tests were performed at screening, baseline and 3‐4 weeks after completing treatment, to quantify the reduction in Total Symptom Scores (as the primary endpoint) with each cumulative dose. Multiple Comparison Procedure and Modeling analysis was used to test for the dose response, shape of the curve and estimation of the median effective dose (ED50), a measure of potency.
Results: Statistically significant dose responses (P < .01 & .001) were seen, respectively. The highest cumulative dose in PQBirch204 (27 300 standardized units [SU]) approached a plateau. Potency of the PQBirch was demonstrated by an ED50 2723 SU, just over half the current dose. Prevalence of treatment‐emergent adverse events was similar for active doses, most being short‐lived and mild. Compliance was over 85% in all groups.
Conclusion: Increasing the cumulative dose of PQBirch 5.5‐fold from 5100 to 27 300 SU achieved an absolute point difference from placebo of 1.91, a relative difference 32.3% and an increase in efficacy of 50%, without compromising safety. The cumulative dose response was confirmed to be curvilinear in shape.
Strong dose response after immunotherapy with PQ grass using conjunctival provocation testing
(2019)
Background: Pollinex Quattro Grass (PQ Grass) is an effective, well-tolerated, short pre-seasonal subcutaneous immunotherapy to treat seasonal allergic rhinoconjunctivitis (SAR) due to grass pollen. In this Phase II study, 4 cumulative doses of PQ Grass and placebo were evaluated to determine its optimal cumulative dose.
Methods: Patients with grass pollen-induced SAR were randomised to either a cumulative dose of PQ Grass (5100, 14400, 27600 and 35600 SU) or placebo, administered as 6 weekly subcutaneous injections over 31–41 days (EudraCT number 2017-000333-31). Standardized conjunctival provocation tests (CPT) using grass pollen allergen extract were performed at screening, baseline and post-treatment to determine the total symptom score (TSS) assessed approximately 4 weeks after dosing. Three models were pre-defined (Emax, logistic, and linear in log-dose model) to evaluate a dose response relationship.
Results: In total, 95.5% of the 447 randomized patients received all 6 injections. A highly statistically significant (p < 0.0001), monotonic dose response was observed for all three pre-specified models. All treatment groups showed a statistically significant decrease from baseline in TSS compared to placebo, with the largest decrease observed after 27600 SU (p < 0.0001). The full course of 6 injections was completed by 95.5% of patients. Treatment-emergent adverse events were similar across PQ Grass groups, and mostly mild and transient in nature.
Conclusions: PQ Grass demonstrated a strong curvilinear dose response in TSS following CPT without compromising its safety profile.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p–Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.