Refine
Year of publication
Document Type
- Article (15) (remove)
Has Fulltext
- yes (15)
Is part of the Bibliography
- no (15)
Keywords
Institute
- Physik (12)
- Medizin (2)
- Sportwissenschaften (2)
The toolbox for imaging molecules is well-equipped today. Some techniques visualize the geometrical structure, others the electron density or electron orbitals. Molecules are many-body systems for which the correlation between the constituents is decisive and the spatial and the momentum distribution of one electron depends on those of the other electrons and the nuclei. Such correlations have escaped direct observation by imaging techniques so far. Here, we implement an imaging scheme which visualizes correlations between electrons by coincident detection of the reaction fragments after high energy photofragmentation. With this technique, we examine the H2 two-electron wave function in which electron–electron correlation beyond the mean-field level is prominent. We visualize the dependence of the wave function on the internuclear distance. High energy photoelectrons are shown to be a powerful tool for molecular imaging. Our study paves the way for future time resolved correlation imaging at FELs and laser based X-ray sources.
When a very strong light field is applied to a molecule an electron can be ejected by tunneling. In order to quantify the time-resolved dynamics of this ionization process, the concept of the Wigner time delay can be used. The properties of this process can depend on the tunneling direction relative to the molecular axis. Here, we show experimental and theoretical data on the Wigner time delay for tunnel ionization of H2 molecules and demonstrate its dependence on the emission direction of the electron with respect to the molecular axis. We find, that the observed changes in the Wigner time delay can be quantitatively explained by elongated/shortened travel paths of the emitted electrons, which occur due to spatial shifts of the electrons’ birth positions after tunneling. Our work provides therefore an intuitive perspective towards the Wigner time delay in strong-field ionization.
Time resolved measurements of the biased disk effect at an Electron Cyclotron Resonance Ion Source
(1999)
First results are reported from time resolved measurements of ion currents extracted from the Frankfurt 14 GHz Electron Cyclotron Resonance Ion Source with pulsed biased-disk voltage. It was found that the ion currents react promptly to changes of the bias. From the experimental results it is concluded that the biased disk effect is mainly due to improvements of the extraction conditions for the source and/or an enhanced transport of ions into the extraction area. By pulsing the disk voltage, short current pulses of highly charged ions can be generated with amplitudes significantly higher than the currents obtained in continuous mode.
How long does it take to emit an electron from an atom? This question has intrigued scientists for decades. As such emission times are in the attosecond regime, the advent of attosecond metrology using ultrashort and intense lasers has re-triggered strong interest on the topic from an experimental standpoint. Here, we present an approach to measure such emission delays, which does not require attosecond light pulses, and works without the presence of superimposed infrared laser fields. We instead extract the emission delay from the interference pattern generated as the emitted photoelectron is diffracted by the parent ion’s potential. Targeting core electrons in CO, we measured a 2d map of photoelectron emission delays in the molecular frame over a wide range of electron energies. The emission times depend drastically on the photoelectrons’ emission directions in the molecular frame and exhibit characteristic changes along the shape resonance of the molecule.
n this paper we report on the investigation of baryonic resonance production in proton-proton collisions at the kinetic energies of 1.25 GeV and 3.5 GeV, based on data measured with HADES. Exclusive channels npπ+ and ppπ0 as well as ppe+e− were studied simultaneously in the framework of a one-boson exchange model. The resonance cross sections were determined from the one-pion channels for Δ(1232) and N(1440) (1.25 GeV) as well as further Δ and N* resonances up to 2 GeV/c2 for the 3.5 GeV data. The data at 1.25 GeV energy were also analysed within the framework of the partial wave analysis together with the set of several other measurements at lower energies. The obtained solutions provided the evolution of resonance production with the beam energy, showing a sizeable non-resonant contribution but with still dominating contribution of Δ(1232)P33. In the case of 3.5 GeV data, the study of the ppe+e− channel gave the insight on the Dalitz decays of the baryon resonances and, in particular, on the electromagnetic transition form-factors in the time-like region. We show that the assumption of a constant electromagnetic transition form-factors leads to underestimation of the yield in the dielectron invariant mass spectrum below the vector mesons pole. On the other hand, a comparison with various transport models shows the important role of intermediate ρ production, though with a large model dependency. The exclusive channels analysis done by the HADES collaboration provides new stringent restrictions on the parameterizations used in the models.
The KER for electron capture of vibrational cooled HeH+ and H3 + ions at 20 keV from residual gas atoms has been measured in the Frankfurt Low Energy Storage Ring (FLSR). At a vacuum in the order of few 10-11 mbar, this residual gas consists to 99% of H2 molecules. For the identification of the recoil products of this reaction, a recoil spectrometer (with an MCP-detector with position and time sensitive read out) was installed at one of the focus points (IP) in the FLSR. The planned extension of this set up by a gas target to a full COLTRIMS reaction microscope will be discussed.
A central motivation for the development of x-ray free-electron lasers has been the prospect of time-resolved single-molecule imaging with atomic resolution. Here, we show that x-ray photoelectron diffraction—where a photoelectron emitted after x-ray absorption illuminates the molecular structure from within—can be used to image the increase of the internuclear distance during the x-ray-induced fragmentation of an O2 molecule. By measuring the molecular-frame photoelectron emission patterns for a two-photon sequential K-shell ionization in coincidence with the fragment ions, and by sorting the data as a function of the measured kinetic energy release, we can resolve the elongation of the molecular bond by approximately 1.2 a.u. within the duration of the x-ray pulse. The experiment paves the road toward time-resolved pump-probe photoelectron diffraction imaging at high-repetition-rate x-ray free-electron lasers.
Purpose: The PELICAN trial evaluates for the first time efficacy and safety of pegylated liposomal doxorubicin (PLD) versus capecitabine as first-line treatment of metastatic breast cancer (MBC).
Methods: This randomized, phase III, open-label, multicenter trial enrolled first-line MBC patients who were ineligible for endocrine or trastuzumab therapy. Cumulative adjuvant anthracyclines of 360 mg/m2 doxorubicin or equivalent were allowed. Left ventricular ejection fraction of >50 % was required. Patients received PLD 50 mg/m2 every 28 days or capecitabine 1250 mg/m2 twice daily for 14 days every 21 days. The primary endpoint was time-to-disease progression (TTP).
Results: 210 patients were randomized (n = 105, PLD and n = 105, capecitabine). Adjuvant anthracyclines were given to 37 % (PLD) and 36 % (capecitabine) of patients. No significant difference was observed in TTP [HR = 1.21 (95 % confidence interval, 0.838–1.750)]. Median TTP was 6.0 months for both PLD and capecitabine. Comparing patients with or without prior anthracyclines, no significant difference in TTP was observed in the PLD arm (log-rank P = 0.64). For PLD versus capecitabine, respectively, overall survival (median, 23.3 months vs. 26.8 months) and time-to-treatment failure (median, 4.6 months vs. 3.7 months) were not statistically significantly different. Compared to PLD, patients on capecitabine experienced more serious adverse events (P = 0.015) and more cardiac events among patients who had prior anthracycline exposure (18 vs. 8 %; P = 0.31).
Conclusion: Both PLD and capecitabine are effective first-line agents for MBC.