Refine
Year of publication
Document Type
- Preprint (718)
- Article (702)
- Working Paper (6)
- Conference Proceeding (3)
- Doctoral Thesis (3)
- Report (2)
Has Fulltext
- yes (1434)
Is part of the Bibliography
- no (1434)
Keywords
- Heavy Ion Experiments (21)
- Hadron-Hadron Scattering (11)
- Hadron-Hadron scattering (experiments) (11)
- LHC (9)
- Heavy-ion collision (6)
- ALICE experiment (4)
- COVID-19 (4)
- Cancer (4)
- Collective Flow (4)
- Depression (4)
Institute
- Physik (1124)
- Frankfurt Institute for Advanced Studies (FIAS) (994)
- Informatik (925)
- Medizin (166)
- Geowissenschaften (39)
- Institut für Ökologie, Evolution und Diversität (14)
- Biowissenschaften (13)
- Biodiversität und Klima Forschungszentrum (BiK-F) (10)
- Senckenbergische Naturforschende Gesellschaft (8)
- ELEMENTS (7)
Background: Intestinal perforation or leakage increases morbidity and mortality of surgical and endoscopic interventions. We identified criteria for use of full-covered, extractable self-expanding metal stents (cSEMS) vs. "Over the scope"-clips (OTSC) for leak closure.
Methods: Patients who underwent endoscopic treatment for postoperative leakage, endoscopic perforation, or spontaneous rupture of the upper gastrointestinal tract between 2006 and 2013 were identified at four tertiary endoscopic centers. Technical success, outcome (e.g. duration of hospitalization, in-hospital mortality), and complications were assessed and analyzed with respect to etiology, size and location of leakage.
Results: Of 106 patients (male: 75 (71%), female: 31 (29%); age (mean ± SD): 62.5 ± 1.3 years, 72 (69%) were treated by cSEMS and 34 (31%) by OTSC. For cSEMS vs. OTSC, mean treatment duration was 41.1 vs. 25 days, p<0.001, leakage size 10 (1-50) vs. 5 (1-30) mm (median (range)), and complications were observed in 68% vs. 8.8%, p<0.001, respectively. Clinical success for primary interventional treatment was observed in 29/72 (40%) vs. 24/34 (70%, p = 0.006), and clinical success at the end of follow-up was 46/72 (64%) vs. 29/34 (85%) for patients treated by cSEMS vs. OTSC; p = 0.04.
Conclusion: OTSC is preferred in small-sized lesions and in perforation caused by endoscopic interventions, cSEMS in patients with concomitant local infection or abscess. cSEMS is associated with a higher frequency of complications. Therefore, OTSC might be preferred if technically feasible. Indication criteria for cSEMS vs. OTSC vary and might impede design of randomized studies.
Whereas the lack of biomarkers in penile cancer (PeCa) impedes the development of efficacious treatment protocols, preliminary evidence suggests that c-MET and associated signaling elements may be dysregulated in this disorder. In the following study, we investigated whether c-MET and associated key molecular elements may have prognostic and therapeutic utility in PeCa. Formalin-fixed, paraffin-embedded tumor tissue from therapy-naïve patients with invasive PeCa was used for tissue microarray (TMA) analysis. Immunohistochemical staining was performed to determine the expression of the proteins c-MET, PPARg, β-catenin, snail, survivin, and n-MYC. In total, 94 PeCa patients with available tumor tissue were included. The median age was 64.9 years. High-grade tumors were present in 23.4%, and high-risk HPV was detected in 25.5%. The median follow-up was 32.5 months. High expression of snail was associated with HPV-positive tumors. Expression of β-catenin was inversely associated with grading. In both univariate COX regression analysis and the log-rank test, an increased expression of PPARg and c-MET was predictive of inferior disease-specific survival (DSS). Moreover, in multivariate analysis, a higher expression of c-MET was independently associated with worse DSS. Blocking c-MET with cabozantinib and tivantinib induced a significant decrease in viability in the primary PeCa cell line UKF-PeC3 isolated from the tumor tissue as well as in cisplatin- and osimertinib-resistant sublines. Strikingly, a higher sensitivity to tivantinib could be detected in the latter, pointing to the promising option of utilizing this agent in the second-line treatment setting.
Purpose: To evaluate intermediate and long-term visual outcomes and safety of a phakic intraocular posterior chamber lens with a central hole (ICL V4c) for myopic eyes.
Methods: Retrospective, consecutive case study of patients that uneventfully received a ICL V4c for myopia correction, with a 5-year postoperative follow-up. Department of Ophthalmology, Goethe University Frankfurt, Germany.
Results: From 241 eyes that underwent ICL implantation, we included 45 eyes with a mean age at surgery of 33 years ± 6 (18–48 years), with a 5 years follow-up. CDVA improved from 0.05logMAR ± 0.15 CDVA preoperatively to − 0.00 ± 0,07 at 5 years and did not change significantly from 3 to 5 years’ time (p = 0.266). The mean spherical equivalent (SE) improved from -10.13D ± 3.39 to − 0.45D ± 0.69. The change in endothelial cell count showed a mean decrease of 1.9% per year throughout the follow-up. Safety and efficacy index were 1.16 and 0.78, respectively. Cataract formation was seen in 2 of 241 eyes (0.8%), but in none of the 45 eyes that finished the 5-year follow-up.
Conclusions: Our data show a good intermediate and long-term stability, efficiency, and safety of ICL V4c phakic lenses in myopic eyes comparable to other known literature.
This prospective study sought to evaluate potential savings of radiation dose to medical staff using real-time dosimetry coupled with visual radiation dose feedback during angiographic interventions. For this purpose, we analyzed a total of 214 angiographic examinations that consisted of chemoembolizations and several other types of therapeutic interventions. The Unfors RaySafe i2 dosimeter was worn by the interventionalist at chest height over the lead protection. A total of 110 interventions were performed with real-time radiation dosimetry allowing the interventionalist to react upon higher x-ray exposure and 104 examinations served as the comparative group without real-time radiation monitoring. By using the real-time display during interventions, the overall mean operator radiation dose decreased from 3.67 (IQR, 0.95–23.01) to 2.36 μSv (IQR, 0.52–12.66) (−36%; p = 0.032) at simultaneously reduced operator exposure time by 4.5 min (p = 0.071). Dividing interventions into chemoembolizations and other types of therapeutic interventions, radiation dose decreased from 1.31 (IQR, 0.46-3.62) to 0.95 μSv (IQR, 0.53-3.11) and from 24.39 (IQR, 12.14-63.0) to 10.37 μSv (IQR, 0.85-36.84), respectively, using live-screen dosimetry (p ≤ 0.005). Radiation dose reductions were also observed for the participating assistants, indicating that they could also benefit from real-time visual feedback dosimetry during interventions (−30%; p = 0.039). Integration of real-time dosimetry into clinical processes might be useful in reducing occupational radiation exposure time during angiographic interventions. The real-time visual feedback raised the awareness of interventionalists and their assistants to the potential danger of prolonged radiation exposure leading to the adoption of radiation-sparing practices. Therefore, it might create a safer environment for the medical staff by keeping the applied radiation exposure as low as possible.