Refine
Year of publication
Document Type
- Article (57)
- Preprint (2)
- Conference Proceeding (1)
Language
- English (60)
Has Fulltext
- yes (60)
Is part of the Bibliography
- no (60)
Keywords
- 140Ce (1)
- Anti-inflammatory (1)
- COVID-19 (1)
- Electromagnetic transitions (1)
- Low-dose radiation therapy (1)
- MACS (1)
- Models & methods for nuclear reactions (1)
- Neutron physics (1)
- Nuclear reactions (1)
- Pneumonia (1)
Institute
- Physik (56)
- Medizin (3)
- Biochemie, Chemie und Pharmazie (1)
- Georg-Speyer-Haus (1)
An accurate measurement of the 140Ce(n,γ) energy-dependent cross-section was performed at the n_TOF facility at CERN. This cross-section is of great importance because it represents a bottleneck for the s-process nucleosynthesis and determines to a large extent the cerium abundance in stars. The measurement was motivated by the significant difference between the cerium abundance measured in globular clusters and the value predicted by theoretical stellar models. This discrepancy can be ascribed to an overestimation of the 140Ce capture cross-section due to a lack of accurate nuclear data. For this measurement, we used a sample of cerium oxide enriched in 140Ce to 99.4%. The experimental apparatus consisted of four deuterated benzene liquid scintillator detectors, which allowed us to overcome the difficulties present in the previous measurements, thanks to their very low neutron sensitivity. The accurate analysis of the p-wave resonances and the calculation of their average parameters are fundamental to improve the evaluation of the 140Ce Maxwellian-averaged cross-section.
Neutron capture on 241Am plays an important role in the nuclear energy production and also provides valuable information for the improvement of nuclear models and the statistical interpretation of the nuclear properties. A new experiment to measure the 241Am(n, γ) cross section in the thermal region and the first few resonances below 10 eV has been carried out at EAR2 of the n_TOF facility at CERN. Three neutron-insensitive C6D6 detectors have been used to measure the neutron-capture gamma cascade as a function of the neutron time of flight, and then deduce the neutron capture yield. Preliminary results will be presented and compared with previously obtained results at the same facility in EAR1. In EAR1 the gamma-ray background at thermal energies was about 90% of the signal while in EAR2 is up to a 25 factor much more favorable signal to noise ratio. We also extended the low energy limit down to subthermal energies. This measurement will allow a comparison with neutron capture measurements conducted at reactors and using a different experimental technique.
In the current dismal situation of the COVID-19 pandemic, effective management of patients with pneumonia and acute respiratory distress syndrome is of vital importance. Due to the current lack of effective pharmacological concepts, this situation has caused interest in (re)considering historical reports on the treatment of patients with low-dose radiation therapy for pneumonia. Although these historical reports are of low-level evidence per se, hampering recommendations for decision-making in the clinical setting, they indicate effectiveness in the dose range between 0.3 and 1 Gy, similar to more recent dose concepts in the treatment of acute and chronic inflammatory/degenerative benign diseases with, e.g., a single dose per fraction of 0.5 Gy. This concise review aims to critically review the evidence for low-dose radiation treatment of COVID-19 pneumopathy and discuss whether it is worth investigating in the present clinical situation.
A randomised, double-blind, placebo-controlled trial of trichuris suis ova in active crohn's disease
(2017)
BACKGROUND AND AIMS To investigate the efficacy and safety of three different dosages of embryonated, viable eggs of Trichuris suis [TSO] versus placebo for induction of remission in mildly-to-moderately active ileocolonic, uncomplicated Crohn's disease [CD].
METHODS Adults with active CD [n = 252] randomly received six fortnightly doses of 250, 2500, or 7500 TSO/15 ml suspension/day [TSO 250, TSO 2500, TSO 7500], or 15 ml placebo solution/day, in a double-blind fashion, with 4 weeks' follow-up. Primary endpoint was the rate of clinical remission [Crohn's Disease Activity Index [CDAI] < 150] at end of treatment, ie at Week 12 or withdrawal. Secondary endpoints included the course of clinical remission, rate of clinical response, change in CDAI, change in markers of inflammation, mucosal healing, and Physician's Global Assessment.
RESULTS Clinical remission at Week 12 occurred in 38.5%, 35.2%, and 47.2% of TSO 250, TSO 2500, and TSO 7500 patients, respectively, and in 42.9% of placebo recipients. TSO induced a dose-dependent immunological response. There was no response regarding laboratory markers of inflammation. Other secondary efficacy variables also showed no advantage of TSO over placebo for treatment of active CD. Administration of TSO did not result in any serious adverse drug reaction. Review of non-serious suspected adverse drug reactions following TSO did not reveal any safety concerns.
CONCLUSIONS Administration of 250-7500 TSO fortnightly over 12 weeks was safe and showed a dose-dependent immunological response, but no TSO dose showed a clinically relevant effect over placebo for induction of clinical remission or response in mildly-to-moderately active, ileocolonic CD.
Although the 12C(n,p)12B and 12C(n,d)11B reactions are of interest in several fields of basic and applied Nuclear Physics the present knowledge of these two cross-sections is far from being accurate and reliable, with both evaluations and data showing sizable discrepancies. As part of the challenging n_TOF program on (n,cp) nuclear reactions study, the energy differential cross-sections of the 12C(n,p)12B and 12C(n,d)11 B reactions have been measured at CERN from the reaction thresholds up to 30 MeV neutron energy. Both measurements have been recently performed at the long flight-path (185 m) experimental area of the n_TOF facility at CERN using a pure (99.95%) rigid graphite target and two silicon telescopes. In this paper an overview of the experiment is presented together with a few preliminary results.
The study of neutron-induced reactions is of high relevance in a wide variety of fields, ranging from stellar nucleosynthesis and fundamental nuclear physics to applications of nuclear technology. In nuclear energy, high accuracy neutron data are needed for the development of Generation IV fast reactors and accelerator driven systems, these last aimed specifically at nuclear waste incineration, as well as for research on innovative fuel cycles. In this context, a high luminosity Neutron Time Of Flight facility, n_TOF, is operating at CERN since more than a decade, with the aim of providing new, high accuracy and high resolution neutron cross-sections. Thanks to the features of the neutron beam, a rich experimental program relevant to nuclear technology has been carried out so far. The program will be further expanded in the near future, thanks in particular to a new high-flux experimental area, now under construction.
High precision measurement of the radiative capture cross section of 238U at the n_TOF CERN facility
(2017)
The importance of improving the accuracy on the capture cross-section of 238U has been addressed by the Nuclear Energy Agency, since its uncertainty significantly affects the uncertainties of key design parameters for both fast and thermal nuclear reactors. Within the 7th framework programme ANDES of the European Commission three different measurements have been carried out with the aim of providing the 238U(n,γ) cross-section with an accuracy which varies from 1 to 5%, depending on the energy range. Hereby the final results of the measurement performed at the n_TOF CERN facility in a wide energy range from 1 eV to 700 keV will be presented.
Neutron-induced fission cross sections of 238U and 235U are used as standards in the fast neutron region up to 200 MeV. A high accuracy of the standards is relevant to experimentally determine other neutron reaction cross sections. Therefore, the detection effciency should be corrected by using the angular distribution of the fission fragments (FFAD), which are barely known above 20 MeV. In addition, the angular distribution of the fragments produced in the fission of highly excited and deformed nuclei is an important observable to investigate the nuclear fission process.
In order to measure the FFAD of neutron-induced reactions, a fission detection setup based on parallel-plate avalanche counters (PPACs) has been developed and successfully used at the CERN-n_TOF facility. In this work, we present the preliminary results on the analysis of new 235U(n,f) and 238U(n,f) data in the extended energy range up to 200 MeV compared to the existing experimental data.
The n_TOF facility operates at CERN with the aim of addressing the request of high accuracy nuclear data for advanced nuclear energy systems as well as for nuclear astrophysics. Thanks to the features of the neutron beam, important results have been obtained on neutron induced fission and capture cross sections of U, Pu and minor actinides. Recently the construction of another beam line has started; the new line will be complementary to the first one, allowing to further extend the experimental program foreseen for next measurement campaigns.