Refine
Year of publication
Document Type
- Preprint (672)
- Article (455)
- Part of a Book (1)
- Conference Proceeding (1)
- Review (1)
- Working Paper (1)
Has Fulltext
- yes (1131)
Is part of the Bibliography
- no (1131)
Keywords
- Heavy Ion Experiments (20)
- Hadron-Hadron Scattering (11)
- Hadron-Hadron scattering (experiments) (11)
- LHC (9)
- Heavy-ion collision (6)
- ALICE experiment (4)
- Collective Flow (4)
- Jets (4)
- Quark-Gluon Plasma (4)
- ALICE (3)
Institute
- Physik (1067)
- Frankfurt Institute for Advanced Studies (FIAS) (964)
- Informatik (924)
- Medizin (41)
- Geowissenschaften (7)
- Biochemie und Chemie (4)
- Informatik und Mathematik (3)
- Biowissenschaften (2)
- ELEMENTS (2)
- Hochschulrechenzentrum (2)
- Institut für Ökologie, Evolution und Diversität (2)
- Zentrum für Arzneimittelforschung, Entwicklung und Sicherheit (ZAFES) (2)
- Biodiversität und Klima Forschungszentrum (BiK-F) (1)
- Georg-Speyer-Haus (1)
- Geowissenschaften / Geographie (1)
- Neuere Philologien (1)
- Pharmazie (1)
- Senckenbergische Naturforschende Gesellschaft (1)
- Sportwissenschaften (1)
- Wirtschaftswissenschaften (1)
Background: School attendance during the COVID-19 pandemic is intensely debated.
Aim: In November 2020, we assessed SARS-CoV-2 infections and seroreactivity in 24 randomly selected school classes and connected households in Berlin, Germany.
Methods: We collected oro-nasopharyngeal swabs and blood samples, examining SARS-CoV-2 infection and IgG antibodies by RT-PCR and ELISA. Household members self-swabbed. We assessed individual and institutional prevention measures. Classes with SARS-CoV-2 infection and connected households were retested after 1 week.
Results: We examined 1,119 participants, including 177 primary and 175 secondary school students, 142 staff and 625 household members. SARS-CoV-2 infection occurred in eight classes, affecting each 1–2 individuals. Infection prevalence was 2.7% (95% confidence interval (CI): 1.2–5.0; 9/338), 1.4% (95% CI: 0.2–5.1; 2/140), and 2.3% (95% CI: 1.3–3.8; 14/611) among students, staff and household members. Six of nine infected students were asymptomatic at testing. We detected IgG antibodies in 2.0% (95%CI: 0.8–4.1; 7/347), 1.4% (95% CI: 0.2–5.0; 2/141) and 1.4% (95% CI: 0.6–2.7; 8/576). Prevalence increased with inconsistent facemask-use in school, walking to school, and case-contacts outside school. For three of nine households with infection(s), origin in school seemed possible. After 1 week, no school-related secondary infections appeared in affected classes; the attack rate in connected households was 1.1%.
Conclusion: School attendance under rigorously implemented preventive measures seems reasonable. Balancing risks and benefits of school closures need to consider possible spill-over infection into households. Deeper insight is required into the infection risks due to being a schoolchild vs attending school.
Background: School attendance during the SARS-CoV-2 pandemic is intensely debated. Modelling studies suggest that school closures contribute to community transmission reduction. However, data among school-attending students and staff are scarce. In November 2020, we examined SARS-CoV-2 infections and seroreactivity in 24 randomly selected school classes and connected households in Berlin, Germany.
Methods: Students and school staff were examined, oro-nasopharyngeal swabs and blood samples collected, and SARS-CoV-2 infection and IgG antibodies detected by RT-PCR and ELISA. Household members performed self-swabs. Individual and institutional infection prevention and control measures were assessed. Classes with SARS-CoV-2 infection and connected household members were re-tested after one week.
Findings: 1119 participants were examined, including 177 primary and 175 secondary school students, 142 staff, and 625 household members. Participants reported mainly cold symptoms (19·4%). SARS-CoV-2 infection occurred in eight of 24 classes affecting each 1-2 individuals. Infection prevalence was 2·7% (95%CI; 1·2-5·0%; 9/338), 1·4% (0·2-5·1%; 2/140), and 2·3% (1·3-3·8%; 14/611) among students, staff and household members, respectively, including quarantined persons. Six of nine infected students were asymptomatic. Prevalence increased with inconsistent facemask use in school, way to school on foot, and case-contacts outside school. IgG antibodies were detected in 2·0% (0·8-4·1%; 7/347), 1·4% (0·2-5·0%; 2/141) and 1·4% (0·6-2·7%; 8/576), respectively. For three of nine households with infection(s) detected at cross-sectional assessment, origin in school seemed possible. After one week, no school-related, secondary infections appeared in affected classes; the attack rate in connected households was 1·1%.
Interpretation: These data suggest that school attendance under preventive measures is feasible, provided their rigorous implementation. In balancing threats and benefits of open versus closed schools during the pandemic, parents and society need to consider possible spill-overs into their households. Deeper insight is needed into the infection risks due to being a schoolchild as compared to attending school.
Background: The diagnostic accuracy of the Elecsys® HCV Duo antigen-antibody combination immunoassay (Roche Diagnostics GmbH) was evaluated for the detection of hepatitis C virus (HCV) infection, versus commercially available comparators.
Methods: This multicenter study (August 2020–March 2021) assessed the specificity of the Elecsys HCV Duo immunoassay and comparator assays in blood donor and routine clinical laboratory samples; sensitivity was determined in confirmed HCV-positive samples and seroconversion panels. The Elecsys HCV Duo immunoassay was compared with the Monolisa HCV Ag-Ab ULTRA V2, Murex HCV Ag/Ab Combination and ARCHITECT HCV Ag assays, as well as nucleic acid testing (NAT). The antibody (anti-HCV) module of the Elecsys HCV Duo immunoassay was compared with the Elecsys Anti-HCV II, Alinity s Anti-HCV, ARCHITECT Anti-HCV and RIBA HCV 3.0 SIA assays.
Results: The specificity of the Elecsys HCV Duo immunoassay was 99.94% (95% confidence interval [CI], 99.89–99.97) and 99.92% (95% CI, 99.71–99.99) in blood donor (n = 20,634) and routine clinical laboratory samples (n = 2531), respectively. The specificity of the Elecsys HCV Duo immunoassay was similar or better than comparator assays. The sensitivity of the Elecsys HCV Duo immunoassay in confirmed HCV-positive samples (n = 257) was 99.6%. In seroconversion panels, the Elecsys HCV Duo immunoassay detected infections earlier (2.2–21.9 days) than all but one of the comparator assays and detected HCV 1.8 days later than NAT.
Conclusions: The Elecsys HCV Duo immunoassay shows high diagnostic accuracy, reduces the diagnostic window, and could be used when NAT is not possible.
The study of neutron-induced reactions is of high relevance in a wide variety of fields, ranging from stellar nucleosynthesis and fundamental nuclear physics to applications of nuclear technology. In nuclear energy, high accuracy neutron data are needed for the development of Generation IV fast reactors and accelerator driven systems, these last aimed specifically at nuclear waste incineration, as well as for research on innovative fuel cycles. In this context, a high luminosity Neutron Time Of Flight facility, n_TOF, is operating at CERN since more than a decade, with the aim of providing new, high accuracy and high resolution neutron cross-sections. Thanks to the features of the neutron beam, a rich experimental program relevant to nuclear technology has been carried out so far. The program will be further expanded in the near future, thanks in particular to a new high-flux experimental area, now under construction.
The n_TOF facility operates at CERN with the aim of addressing the request of high accuracy nuclear data for advanced nuclear energy systems as well as for nuclear astrophysics. Thanks to the features of the neutron beam, important results have been obtained on neutron induced fission and capture cross sections of U, Pu and minor actinides. Recently the construction of another beam line has started; the new line will be complementary to the first one, allowing to further extend the experimental program foreseen for next measurement campaigns.
Activation of TRPC6 channels is essential for lung ischaemia–reperfusion induced oedema in mice
(2012)
Lung ischaemia–reperfusion-induced oedema (LIRE) is a life-threatening condition that causes pulmonary oedema induced by endothelial dysfunction. Here we show that lungs from mice lacking nicotinamide adenine dinucleotide phosphate (NADPH) oxidase (Nox2y/−) or the classical transient receptor potential channel 6 (TRPC6−/−) are protected from LIR-induced oedema (LIRE). Generation of chimeric mice by bone marrow cell transplantation and endothelial-specific Nox2 deletion showed that endothelial Nox2, but not leukocytic Nox2 or TRPC6, are responsible for LIRE. Lung endothelial cells from Nox2- or TRPC6-deficient mice showed attenuated ischaemia-induced Ca2+ influx, cellular shape changes and impaired barrier function. Production of reactive oxygen species was completely abolished in Nox2y/− cells. A novel mechanistic model comprising endothelial Nox2-derived production of superoxide, activation of phospholipase C-γ, inhibition of diacylglycerol (DAG) kinase, DAG-mediated activation of TRPC6 and ensuing LIRE is supported by pharmacological and molecular evidence. This mechanism highlights novel pharmacological targets for the treatment of LIRE.
The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis.
In this paper we describe in detail the design considerations for this detector for operation in the extreme multiplicity environment of central Pb–Pb collisions at LHC energy. The implementation of the resulting requirements into hardware (field cage, read-out chambers, electronics), infrastructure (gas and cooling system, laser-calibration system), and software led to many technical innovations which are described along with a presentation of all the major components of the detector, as currently realized. We also report on the performance achieved after completion of the first round of stand-alone calibration runs and demonstrate results close to those specified in the TPC Technical Design Report.
Invasive fungal disease (IFD) in hematopoietic stem cell transplantation is associatedwith high morbidity and mortality. As the antifungal host response determines risk and outcomeof IFD, there is growing interest in adoptive immunotherapy using T cells or natural killer (NK)cells. Although the NK-92 cell line has been tested as anticancer therapy in clinical trials, data onthe antifungal activity of NK-92 cells are lacking. Here, we show that the NK-92 cell line exhibitsconsiderable fungal damage on all medically important fungi tested, such as different species ofAspergillus,Candida, mucormycetes, andFusarium. The extent of fungal damage differs acrossvarious species of mucormycetes andFusarium, whereas it is comparable across different species ofAspergillusandCandida. Interferon (IFN)-γlevels in the supernatant were lower when NK-92 cells areco-incubated withAspergillus fumigatus,Candida albicans, orRhizopus arrhizuscompared to the levelswhen NK-92 cells are incubated alone. Different to primary human NK cells, no increase of perforinlevels in the supernatant was observed when the fungi were added to NK-92 cells. Ourin vitrodatademonstrated that the NK-92 cell line could be a feasible tool for antifungal immunotherapy, butdata of animal models are warranted prior to clinical trials.
Previously we reported modulation of endothelial prostacyclin and interleukin-8 production, cyclooxygenase-2 expression and vasorelaxation by oleoyl-lysophosphatidylcholine (LPC 18:1). In the present study, we examined the impact of this LPC on nitric oxide (NO) bioavailability in vascular endothelial EA.hy926 cells. Basal NO formation in these cells was decreased by LPC 18:1. This was accompanied with a partial disruption of the active endothelial nitric oxide synthase (eNOS)-dimer, leading to eNOS uncoupling and increased formation of reactive oxygen species (ROS). The LPC 18:1-induced ROS formation was attenuated by the superoxide scavenger Tiron, as well as by the pharmacological inhibitors of eNOS, NADPH oxidases, flavin-containing enzymes and superoxide dismutase (SOD). Intracellular ROS-formation was most prominent in mitochondria, less pronounced in cytosol and undetectable in endoplasmic reticulum. Importantly, Tiron completely prevented the LPC 18:1-induced decrease in NO bioavailability in EA.hy926 cells. The importance of the discovered findings for more in vivo like situations was analyzed by organ bath experiments in mouse aortic rings. LPC 18:1 attenuated the acetylcholine-induced, endothelium dependent vasorelaxation and massively decreased NO bioavailability. We conclude that LPC 18:1 induces eNOS uncoupling and unspecific superoxide production. This results in NO scavenging by ROS, a limited endothelial NO bioavailability and impaired vascular function.
Seven different instruments and measurement methods were used to examine the immersion freezing of bacterial ice nuclei from Snomax® (hereafter Snomax), a product containing ice active protein complexes from non-viable Pseudomonas syringae bacteria. The experimental conditions were kept as similar as possible for the different measurements. Of the participating instruments, some examined droplets which had been made from suspensions directly, and the others examined droplets activated on previously generated Snomax particles, with particle diameters of mostly a few hundred nanometers and up to a few micrometers in some cases. Data were obtained in the temperature range from −2 to −38 °C, and it was found that all ice active protein complexes were already activated above −12 °C. Droplets with different Snomax mass concentrations covering 10 orders of magnitude were examined. Some instruments had very short ice nucleation times down to below 1 s, while others had comparably slow cooling rates around 1 K min−1. Displaying data from the different instruments in terms of numbers of ice active protein complexes per dry mass of Snomax, nm, showed that within their uncertainty the data agree well with each other as well as to previously reported literature results. Two parameterizations were taken from literature for a direct comparison to our results, and these were a time dependent approach based on a contact angle distribution Niedermeier et al. (2014) and a modification of the parameterization presented in Hartmann et~al.~(2013) representing a time independent approach. The agreement between these and the measured data were good, i.e. they agreed within a temperature range of 0.6 K or equivalently a range in nm of a factor of 2. From the results presented herein, we propose that Snomax, at least when carefully shared and prepared, is a suitable material to test and compare different instruments for their accuracy of measuring immersion freezing.