Refine
Year of publication
Document Type
- Article (10)
- Preprint (3)
- Contribution to a Periodical (2)
- Report (1)
Has Fulltext
- yes (16)
Is part of the Bibliography
- no (16)
Keywords
- Bioaccumulation (1)
- Cabozantinib (1)
- Canopy height model (1)
- Cerebral toxoplasmosis HIV (1)
- Deutschland (1)
- Diagnosis (1)
- ETS (1)
- EU (1)
- Electron-pion identification (1)
- Endocrine-disrupting compounds (1)
Institute
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p–Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
Der deutsche und französische Innenminister haben eine Initiative gestartet um gegen Verschlüsselung vorzugehen. Ihr Argument, was von mehr oder weniger allen Geheimdiensten/Strafverfolgungsbehörden unisono vorgetragen wird lautet, dass verschlüsselte Kommunikation die Arbeit der Behörden behindere. Bereits im Jahr 1993 wurde die gleiche Debatte geführt, endete aber mit dem Konsens, dass die Vorteile von Verschlüsselung die Nachteile deutlich überwiegen. Dieser Konsens, getragen von Industrie, Datenschützern und Politik (sowohl Liberale als auch Konservative) schien sicher, war er doch die vernünftigste Antwort auf ein komplexes Problem. Heute stellen die von Rechtspopulisten getriebenen Innenminister wieder einmal die Verschlüsselung in Frage. Warum das eine schlechte Idee ist, soll dieser Beitrag klären.NSA Chef Inman argumentierte bereits 1980: “There is
a very real and critical danger that unrestrained public discussion of crypto-logic matters will seriously damage the ability of this government to conduct signals intelligence and the ability of this government to carry out its mission of protecting national security information from hostile exploitation” (1980). Kern dieses “going dark” Arguments ist also, dass digitale Überwachung schwerer würde, wenn alle verschlüsseln. Terroristen und andere bad guys könnten also nicht mehr gefangen werden. Die Debatte ist also gar nicht so neu und überraschend wie immer behauptet wird....
Bewegung im Satz : Remnant Movement – Syntaktische Grundlagenforschung am Institut für Linguistik
(2013)
Background: Chronic particulate matter (PM) exposure is correlated to various health effects, even at low amounts. WHO has defined PM concentration limits as daily and annual mean values which were made legally binding in the European Union. While many studies have focused on PM concentrations in special environments, little is known about the average PM- exposure for both employees and passengers in the German public transportation system.
Methods: Particulate matter (PM10, PM2.5, PM1) - concentrations were monitored for 30 minutes at 15 different areas in Frankfurt am Main with major public traffic. Maximum and mean concentrations and, as a surrogate for the inhaled dosage, the Area Under the Curve (AUC) for 15 minutes of exposure were calculated.
Results: The WHO limits for PM10 and PM2.5 were exceeded at nearly all times and areas. Highest maximum concentrations were found at underground stations, subterranean railway stations and subterranean shopping arcades with much lower values obtained at surface points. In one measurement at a surface test point smokers who neglected the non-smoking policy could be identified as a major cause for a at least temporary strong increase of PM-load as seen in high maximum values and normal averages.
Conclusions: Subterranean areas have high particulate matter contamination exceeding WHO limits. Improvement may be achieved by increased ventilation. Subterranean shops and kiosks, being workplaces with long term exposure, should be equipped with external air supply. The non- smoking policy of the "Deutsche Bahn" for public spaces should be enforced.
Recently, the potent antiandrogen 4-methyl-7-diethylaminocoumarin (C47) and its potential transformation products 4-methyl-7-ethylaminocoumarin (C47T1) and 4-methyl-7-aminocoumarin (C47T2) were identified as novel environmental contaminants. We assessed for the first time the sources, distribution, and fate of these compounds in aquatic systems using the Holtemme River (Saxony-Anhalt, Germany), which is a hotspot for these contaminants. To this end, wastewater-treatment plant (WWTP) influent and effluent samples, surface water samples over 3 years, and the longitudinal profiles in water, sediment, and gammarids were analyzed. From the longitudinal profile of the river stretch, the WWTP of Silstedt was identified as the sole point source for these compounds in the River Holtemme, and exposure concentrations in the low micrograms per liter range could be recorded continuously over 3 years. Analysis of WWTP influent and effluent showed a transformation of approximately half of the C47 into C47T1 and C47T2 but no complete removal. A further attenuation of the three coumarins after discharge into the river could be largely attributed to dilution, while transformation was only approximately 20%, thus suggesting a significant persistence in aquatic systems. Experimentally derived partitioning coefficients between water and sediment organic carbon exceeded those predicted using the OPERA quantitative structure–activity relationship tools and polyparameter linear free-energy relationships by up to 93-fold, suggesting cation binding as a significant factor for their sorption behavior. Near-equilibrium conditions between water and sediment were not observed close to the emitting WWTP but farther downstream in the river. Experimental and predicted bioaccumulation factors for gammarids were closely matching, and the concentrations in field-sampled gammarids were close to steady state with exposure concentrations in the water phase of the river. Environ Toxicol Chem 2021;40:3078–3091. © 2021 The Authors. Environmental Toxicology and Chemistry published by Wiley Periodicals LLC on behalf of SETAC.
Background: Second hand smoke (ETS)-associated particulate matter (PM) contributes considerably to indoor air contamination and constitutes a health risk for passive smokers. Easy to measure, PM is a useful parameter to estimate the dosage of ETS that passive smokers are exposed to. Apart from its suitability as a surrogate parameter for ETS-exposure, PM itself affects human morbidity and mortality in a dose-dependent manner. We think that ETS-associated PM should be considered an independent hazard factor, separately from the many other known harmful compounds of ETS. We believe that brand-specific and tobacco-product-specific differences in the release of PM matter and that these differences are of public interest. Methods: To generate ETS of cigarettes and cigarillos as standardized and reproducible as possible, an automatic second hand smoke emitter (AETSE) was developed and placed in a glass chamber. L&M cigarettes ("without additives", "red label", "blue label"), L&M filtered cigarillos ("red") and 3R4F standard research cigarettes (as reference) were smoked automatically according to a self-developed, standardized protocol until the tobacco product was smoked down to 8 mm distance from the tipping paper of the filter. Results: Mean concentration (Cmean) and area under the curve (AUC) in a plot of PM2.5 against time were measured, and compared. CmeanPM2.5 were found to be 518 μg/m3 for 3R4F cigarettes, 576 μg/m3 for L&M "without additives" ("red"), 448 μg/m3 for L&M "blue label", 547 μg/m3 for L&M "red label", and 755 μg/m3 for L&M filtered cigarillos ("red"). AUCPM2.5-values were 208,214 μg/m3·s for 3R4F reference cigarettes, 204,629 μg/m3·s for L&M "without additives" ("red"), 152,718 μg/m3·s for L&M "blue label", 238,098 μg/m3·s for L&M "red label" and 796,909 μg/m3·s for L&M filtered cigarillos ("red"). Conclusion: Considering the large and significant differences in particulate matter emissions between cigarettes and cigarillos, we think that a favorable taxation of cigarillos is not justifiable.
Background: Anemia is a common condition in the elderly and a significant risk factor for increased morbidity and mortality, reducing not only functional capacity and mobility but also quality of life. Currently, few data are available regarding anemia in hospitalized geriatric patients. Our retrospective study investigated epidemiology and causes of anemia in 405 hospitalized geriatric patients.
Methods: Data analysis was performed using laboratory parameters determined during routine hospital admission procedures (hemoglobin, ferritin, transferrin saturation, C-reactive protein, vitamin B12, folic acid, and creatinine) in addition to medical history and demographics.
Results: Anemia affected approximately two-thirds of subjects. Of 386 patients with recorded hemoglobin values, 66.3% were anemic according to WHO criteria, mostly (85.1%) in a mild form. Anemia was primarily due to iron deficiency (65%), frequently due to underlying chronic infection (62.1%), or of mixed etiology involving a combination of chronic disease and iron deficiency, with absolute iron deficiency playing a comparatively minor role.
Conclusion: Greater awareness of anemia in the elderly is warranted due to its high prevalence and negative effect on outcomes, hospitalization duration, and mortality. Geriatric patients should be routinely screened for anemia and etiological causes of anemia individually assessed to allow timely initiation of appropriate therapy.