Refine
Language
- English (9)
Has Fulltext
- yes (9)
Is part of the Bibliography
- no (9)
Keywords
- 900 GeV (1)
- ALICE (1)
- Anterior cruciate ligament (1)
- Bone density (1)
- Bone disease (1)
- Computed tomography (1)
- Electron-pion identification (1)
- Fibre/foam sandwich radiator (1)
- Head and neck Cancer (1)
- Ionisation energy loss (1)
Institute
- Frankfurt Institute for Advanced Studies (FIAS) (4)
- Informatik (4)
- Medizin (4)
- Physik (4)
- E-Finance Lab e.V. (1)
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p–Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
The inclusive charged particle transverse momentum distribution is measured in proton–proton collisions at s=900 GeV at the LHC using the ALICE detector. The measurement is performed in the central pseudorapidity region (|η|<0.8) over the transverse momentum range 0.15<pT<10 GeV/c. The correlation between transverse momentum and particle multiplicity is also studied. Results are presented for inelastic (INEL) and non-single-diffractive (NSD) events. The average transverse momentum for |η|<0.8 is 〈pT〉INEL=0.483±0.001 (stat.)±0.007 (syst.) GeV/c and 〈pT〉NSD=0.489±0.001 (stat.)±0.007 (syst.) GeV/c, respectively. The data exhibit a slightly larger 〈pT〉 than measurements in wider pseudorapidity intervals. The results are compared to simulations with the Monte Carlo event generators PYTHIA and PHOJET.
Background: Reports of head and neck ultrasound examinations are frequently written by hand as free texts. Naturally, quality and structure of free text reports is variable, depending on the examiner’s individual level of experience. Aim of the present study was to compare the quality of free text reports (FTR) and structured reports (SR) of head and neck ultrasound examinations.
Methods: Both standard FTRs and SRs of head and neck ultrasound examinations of 43 patients were acquired by nine independent examiners with comparable levels of experience. A template for structured reporting of head and neck ultrasound examinations was created using a web-based approach. FTRs and SRs were evaluated with regard to overall quality, completeness, required time to completion, and readability by four independent raters with different specializations (Paired Wilcoxon test, 95% CI) and inter-rater reliability was assessed (Fleiss’ kappa). A questionnaire was used to compare FTRs vs. SRs with respect to user satisfaction (Mann-Whitney U test, 95% CI).
Results: By comparison, completeness scores of SRs were significantly higher than FTRs’ completeness scores (94.4% vs. 45.6%, p < 0.001), and pathologies were described in more detail (91.1% vs. 54.5%, p < 0.001). Readability was significantly higher in all SRs when compared to FTRs (100% vs. 47.1%, p < 0.001). The mean time to complete a report, however, was significantly higher in SRs (176.5 vs. 107.3 s, p < 0.001). SRs achieved significantly higher user satisfaction ratings (VAS 8.87 vs. 1.41, p < 0.001) and a very high inter-rater reliability (Fleiss’ kappa 0.92).
Conclusions: As compared to FTRs, SRs of head and neck ultrasound examinations are more comprehensive and easier to understand. On the balance, the additional time needed for completing a SR is negligible. Also, SRs yield high inter-rater reliability and may be used for high-quality scientific data analyses.
Background: Dual-energy CT (DECT)-derived bone mineral density (BMD) of the distal radius and other CT-derived metrics related to bone health have been suggested for opportunistic osteoporosis screening and risk evaluation for sustaining distal radius fractures (DRFs).
Methods: The distal radius of patients who underwent DECT between 01/2016 and 08/2021 was retrospectively analyzed. Cortical Hounsfield Unit (HU), trabecular HU, cortical thickness, and DECT-based BMD were acquired from a non-fractured, metaphyseal area in all examinations. Receiver-operating characteristic (ROC) analysis was conducted to determine the area under the curve (AUC) values for predicting DRFs based on DECT-derived BMD, HU values, and cortical thickness. Logistic regression models were then employed to assess the associations of these parameters with the occurrence of DRFs.
Results: In this study, 263 patients (median age: 52 years; interquartile range: 36–64; 132 women; 192 fractures) were included. ROC curve analysis revealed a higher area under the curve (AUC) value for DECT-derived BMD compared to cortical HU, trabecular HU, and cortical thickness (0.91 vs. 0.61, 0.64, and 0.69, respectively; p <.001). Logistic regression models confirmed the association between lower DECT-derived BMD and the occurrence of DRFs (Odds Ratio, 0.83; p <.001); however, no influence was observed for cortical HU, trabecular HU, or cortical thickness.
Conclusions: DECT can be used to assess the BMD of the distal radius without dedicated equipment such as calibration phantoms to increase the detection rates of osteoporosis and stratify the individual risk to sustain DRFs. In contrast, assessing HU-based values and cortical thickness does not provide clinical benefit.
Highlights
• Early reconstruction of injured cruciate ligaments improves functional outcomes.
• Modern CT imaging can be used to rapidly identify patients with injury to the cruciate ligaments and streamline therapeutic pathways.
• Dual-energy CT demonstrates superior diagnostic accuracy compared to single-energy CT.
Abstract
Background: This study aimed to evaluate the clinical utility of modern single and dual-energy computed tomography (CT) for assessing the integrity of the cruciate ligaments in patients that sustained acute trauma.
Methods: Patients who underwent single- or dual-energy CT followed by 3 Tesla magnetic resonance imaging (MRI) or knee joint arthroscopy between 01/2016 and 12/2022 were included in this retrospective, monocentric study. Three radiologists specialized in musculoskeletal imaging independently evaluated all CT images for the presence of injury to the cruciate ligaments. An MRI consensus reading of two experienced readers and arthroscopy provided the reference standard. Diagnostic accuracy parameters and area under the receiver operator characteristic curve (AUC) were the primary metrics for diagnostic performance.
Results: CT images of 204 patients (median age, 49 years; IQR 36 – 64; 113 males) were evaluated. Dual-energy CT yielded significantly higher diagnostic accuracy and AUC for the detection of injury to the anterior (94% [240/255] vs 75% [266/357] and 0.89 vs 0.66) and posterior cruciate ligaments (95% [243/255] vs 87% [311/357] and 0.90 vs 0.61) compared to single-energy CT (all parameters, p <.005). Diagnostic confidence and image quality were significantly higher in dual-energy CT compared to single-energy CT (all parameters, p <.005).
Conclusions: Modern dual-energy CT is readily available and can serve as a screening tool for detecting or excluding cruciate ligament injuries in patients with acute trauma. Accurate diagnosis of cruciate ligament injuries is crucial to prevent adverse outcomes, including delayed treatment, chronic instability, or long-term functional limitations.
For acute and chronic soft tissue infections, radical surgical debridement is required and is considered the gold standard, along with its immediate systemic antibiotic therapy. Treatment with local antibiotics and/or antibiotic-containing materials is commonly used as an additional tool in clinical practice. Spraying with fibrin and antibiotics is a newer technique that has been studied for some antibiotics. However, for gentamicin, data are not yet available on absorption, optimal application, antibiotic fate at the site and transfer of antibiotic into the blood. In an animal study involving 29 Sprague Dawley rats, 116 back wounds were sprayed with gentamicin using either gentamicin alone or one of two possible spray combinations of gentamicin and fibrin. Simultaneous application of gentamicin and fibrin via a spray system to soft tissue wounds resulted in significant antibiotic concentration over a long period of time. The technique is easy and cost-effective. The systemic crossover was significantly minimized in our study, which may have led to fewer side effects in patients. These results could lead to an improvement in local antibiotic therapy.