Refine
Year of publication
Language
- English (726)
Has Fulltext
- yes (726) (remove)
Is part of the Bibliography
- no (726)
Keywords
- Heavy Ion Experiments (14)
- Hadron-Hadron Scattering (9)
- Hadron-Hadron scattering (experiments) (8)
- LHC (5)
- ALICE experiment (4)
- Heavy-ion collision (4)
- Quark-Gluon Plasma (4)
- Collective Flow (3)
- Heavy Ions (3)
- Jets and Jet Substructure (3)
Institute
How long does it take to emit an electron from an atom? This question has intrigued scientists for decades. As such emission times are in the attosecond regime, the advent of attosecond metrology using ultrashort and intense lasers has re-triggered strong interest on the topic from an experimental standpoint. Here, we present an approach to measure such emission delays, which does not require attosecond light pulses, and works without the presence of superimposed infrared laser fields. We instead extract the emission delay from the interference pattern generated as the emitted photoelectron is diffracted by the parent ion’s potential. Targeting core electrons in CO, we measured a 2d map of photoelectron emission delays in the molecular frame over a wide range of electron energies. The emission times depend drastically on the photoelectrons’ emission directions in the molecular frame and exhibit characteristic changes along the shape resonance of the molecule.
Background: Simultaneous pancreas kidney transplantation (SPK), pancreas transplantation alone (PTA) or pancreas transplantation after kidney (PAK) are the only curative treatment options for patients with type 1 (juvenile) diabetes mellitus with or without impaired renal function. Unfortunately, transplant waiting lists for this indication are increasing because the current organ acceptability criteria are restrictive; morbidity and mortality significantly increase with time on the waitlist. Currently, only pancreas organs from donors younger than 50 years of age and with a body mass index (BMI) less than 30 are allocated for transplantation in the Eurotransplant (ET) area. To address this issue we designed a study to increase the available donor pool for these patients.
Methods/Design: This study is a prospective, multicenter (20 German centers), single blinded, non-randomized, two armed trial comparing outcome after SPK, PTA or PAK between organs with the currently allowed donor criteria versus selected organs from donors with extended criteria. Extended donor criteria are defined as organs procured from donors with a BMI of 30 to 34 or a donor age between 50 and 60 years. Immunosuppression is generally standardized using induction therapy with Myfortic, tacrolimus and low dose steroids. In principle, all patients on the waitlist for primary SPK, PTA or PAK are eligible for the clinical trial when they consent to possibly receiving an extended donor criteria organ. Patients receiving an organ meeting the current standard criteria for pancreas allocation (control arm) are compared to those receiving extended criteria organ (study arm); patients are blinded for a follow-up period of one year. The combined primary endpoint is survival of the pancreas allograft and pancreas allograft function after three months, as an early relevant outcome parameter for pancreas transplantation.
Discussion: The EXPAND Study has been initiated to investigate the hypothesis that locally allocated extended criteria organs can be transplanted with similar results compared to the currently allowed standard ET organ allocation. If our study shows a favorable comparison to standard organ allocation criteria, the morbidity and mortality for patients waiting for transplantation could be reduced in the future.
Trial registered at: NCT01384006
A central motivation for the development of x-ray free-electron lasers has been the prospect of time-resolved single-molecule imaging with atomic resolution. Here, we show that x-ray photoelectron diffraction—where a photoelectron emitted after x-ray absorption illuminates the molecular structure from within—can be used to image the increase of the internuclear distance during the x-ray-induced fragmentation of an O2 molecule. By measuring the molecular-frame photoelectron emission patterns for a two-photon sequential K-shell ionization in coincidence with the fragment ions, and by sorting the data as a function of the measured kinetic energy release, we can resolve the elongation of the molecular bond by approximately 1.2 a.u. within the duration of the x-ray pulse. The experiment paves the road toward time-resolved pump-probe photoelectron diffraction imaging at high-repetition-rate x-ray free-electron lasers.
Background: Reports of head and neck ultrasound examinations are frequently written by hand as free texts. Naturally, quality and structure of free text reports is variable, depending on the examiner’s individual level of experience. Aim of the present study was to compare the quality of free text reports (FTR) and structured reports (SR) of head and neck ultrasound examinations.
Methods: Both standard FTRs and SRs of head and neck ultrasound examinations of 43 patients were acquired by nine independent examiners with comparable levels of experience. A template for structured reporting of head and neck ultrasound examinations was created using a web-based approach. FTRs and SRs were evaluated with regard to overall quality, completeness, required time to completion, and readability by four independent raters with different specializations (Paired Wilcoxon test, 95% CI) and inter-rater reliability was assessed (Fleiss’ kappa). A questionnaire was used to compare FTRs vs. SRs with respect to user satisfaction (Mann-Whitney U test, 95% CI).
Results: By comparison, completeness scores of SRs were significantly higher than FTRs’ completeness scores (94.4% vs. 45.6%, p < 0.001), and pathologies were described in more detail (91.1% vs. 54.5%, p < 0.001). Readability was significantly higher in all SRs when compared to FTRs (100% vs. 47.1%, p < 0.001). The mean time to complete a report, however, was significantly higher in SRs (176.5 vs. 107.3 s, p < 0.001). SRs achieved significantly higher user satisfaction ratings (VAS 8.87 vs. 1.41, p < 0.001) and a very high inter-rater reliability (Fleiss’ kappa 0.92).
Conclusions: As compared to FTRs, SRs of head and neck ultrasound examinations are more comprehensive and easier to understand. On the balance, the additional time needed for completing a SR is negligible. Also, SRs yield high inter-rater reliability and may be used for high-quality scientific data analyses.
Highlights
• Three ecological groups were identified based on distributional patterns.
• Old assessments were confirmed with the latest occurrence data.
• For each group, we derived different population trends in times of global change.
• Global change elevates importance of vector-borne diseases.
• Our results serve as base for effective Simuliidae monitoring.
Abstract
The black fly genus Simulium includes medically and ecologically important species, characterized by a wide variation of ecological niches largely determining their distributional patterns. In a rapidly changing environment, species-specific niche characteristics determine whether a species benefits or not. With aquatic egg, larval and pupal stages followed by a terrestrial adult phase, their spatial arrangements depend upon the interplay of aquatic conditions and climatic-landscape parameters in the terrestrial realm. The aim of this study was to enhance the understanding of the distributional patterns among Simulium species and their ecological drivers. In an ecological niche modelling approach, we focused on 12 common black fly species with different ecological requirements. Our modelling was based on available distribution data along with five stream variables describing the climatic, land-cover, and topographic conditions of river catchments. The modelled freshwater habitat suitability was spatially interpolated to derive an estimate of the adult black flies' probability of occurrence. Based on similarities in the spatial patterns of modelled habitat suitability we were able to identify three biogeographical groups, which allows us to confirm old assessments with current occurrence data: (A) montane species, (B) broad range species and (C) lowland species. The five veterinary and human medical relevant species Simulium equinum, S. erythrocephalum, S. lineatum, S. ornatum and S. reptans are mainly classified in the lowland species group. In the course of climatic changes, it is expected that biocoenosis will slightly shift towards upstream regions, so that the lowland group will presumably emerge as the winner. This is mainly explained by wider ecological niches, including a higher temperature tolerance and tolerance to various pollutants. In conclusion, these findings have significant implications for human and animal health. As exposure to relevant Simulium species increases, it becomes imperative to remain vigilant, particularly in investigating the potential transmission of pathogens.
The ALICE Zero Degree Calorimeter system (ZDC) is composed of two identical sets of calorimeters, placed at opposite sides with respect to the interaction point, 114 meters away from it, complemented by two small forward electromagnetic calorimeters (ZEM). Each set of detectors consists of a neutron (ZN) and a proton (ZP) ZDC. They are placed at zero degrees with respect to the LHC axis and allow to detect particles emitted close to beam direction, in particular neutrons and protons emerging from hadronic heavy-ion collisions (spectator nucleons) and those emitted from electromagnetic processes. For neutrons emitted by these two processes, the ZN calorimeters have nearly 100% acceptance.
During the √sNN = 2.76 TeV Pb-Pb data-taking, the ALICE Collaboration studied forward neutron emission with a dedicated trigger, requiring a minimum energy deposition in at least one of the two ZN. By exploiting also the information of the two ZEM calorimeters it has been possible to separate the contributions of electromagnetic and hadronic processes and to study single neutron vs. multiple neutron emission.
The measured cross sections of single and mutual electromagnetic dissociation of Pb nuclei at √sNN = 2.76 TeV, with neutron emission, are σsingle EMD = 187:4 ± 0.2 (stat.)−11.2+13.2 (syst.) b and σmutual EMD = 5.7 ± 0.1 (stat.) ±0.4 (syst.) b, respectively [1]. This is the first measurement of electromagnetic dissociation of 208Pb nuclei at the LHC energies, allowing a test of electromagnetic dissociation theory in a new energy regime. The experimental results are compared to the predictions from a relativistic electromagnetic dissociation model.
The centrality dependence of the charged-particle pseudorapidity density measured with ALICE in Pb–Pb collisions at √sNN=2.76 TeV over a broad pseudorapidity range is presented. This Letter extends the previous results reported by ALICE to more peripheral collisions. No strong change of the overall shape of charged-particle pseudorapidity density distributions with centrality is observed, and when normalised to the number of participating nucleons in the collisions, the evolution over pseudorapidity with centrality is likewise small. The broad pseudorapidity range (−3.5<η<5) allows precise estimates of the total number of produced charged particles which we find to range from 162±22(syst.) to 17170±770(syst.) in 80–90% and 0–5% central collisions, respectively. The total charged-particle multiplicity is seen to approximately scale with the number of participating nucleons in the collision. This suggests that hard contributions to the charged-particle multiplicity are limited. The results are compared to models which describe dNch/dη at mid-rapidity in the most central Pb–Pb collisions and it is found that these models do not capture all features of the distributions.
The centrality dependence of the charged-particle pseudorapidity density measured with ALICE in Pb-Pb collisions at sNN−−−√ over a broad pseudorapidity range is presented. This Letter extends the previous results reported by ALICE to more peripheral collisions. No strong change of the charged-particle pseudorapidity density distributions with centrality is observed, and when normalised to the number of participating nucleons in the collisions, the evolution over pseudorapidity with centrality is likewise small. The broad pseudorapidity range allows precise estimates of the total number of produced charged particles which we find to range from 162±22 (syst.) to 17170±770 (syst.) in 80-90% and 0-5 central collisions, respectively. The total charged-particle multiplicity is seen to approximately scale with the number of participating nucleons in the collision. This suggests that hard contributions to the charged-particle multiplicity are limited. The results are compared to models which describe dNch/dη at mid-rapidity in the most central Pb-Pb collisions and it is found that these models do not capture all features of the distributions.
The centrality dependence of the charged-particle pseudorapidity density measured with ALICE in Pb-Pb collisions at sNN−−−√ over a broad pseudorapidity range is presented. This Letter extends the previous results reported by ALICE to more peripheral collisions. No strong change of the charged-particle pseudorapidity density distributions with centrality is observed, and when normalised to the number of participating nucleons in the collisions, the evolution over pseudorapidity with centrality is likewise small. The broad pseudorapidity range allows precise estimates of the total number of produced charged particles which we find to range from 162±22 (syst.) to 17170±770 (syst.) in 80-90% and 0-5 central collisions, respectively. The total charged-particle multiplicity is seen to approximately scale with the number of participating nucleons in the collision. This suggests that hard contributions to the charged-particle multiplicity are limited. The results are compared to models which describe dNch/dη at mid-rapidity in the most central Pb-Pb collisions and it is found that these models do not capture all features of the distributions.