Refine
Year of publication
Document Type
- Article (69) (remove)
Has Fulltext
- yes (69)
Is part of the Bibliography
- no (69)
Keywords
- Magnetic resonance imaging (6)
- CT (4)
- Hepatocellular carcinoma (4)
- MRI (4)
- Artificial intelligence (3)
- Cancer (3)
- microwave ablation (3)
- Algorithms (2)
- Bone density (2)
- DSM (2)
- Dynamic MRI (2)
- Microwave ablation (2)
- Multidetector computed tomography (2)
- Neoplasms (2)
- Osteoporosis (2)
- Radiomics (2)
- Spine (2)
- Tomography (x-ray computed) (2)
- Transarterial chemoembolization (2)
- breast cancer (2)
- computed tomography (2)
- hepatocellular carcinoma (2)
- liver (2)
- 16 segment AHA model (1)
- Ablation Techniques (1)
- Age determination by skeleton (1)
- Anemia (1)
- Angiography (1)
- Aromatase Inhibitors (1)
- Automated Tube Potential Selection (1)
- Awareness campaign (1)
- Berci needle (1)
- Biopsy (1)
- Blood (1)
- Bone diseases, Metabolic (1)
- Bone marrow (1)
- Breast tumors (1)
- COVID-19 (1)
- CT dual-energy computed tomography (1)
- CT pulmonary angiography (1)
- CT radiation exposure (1)
- CT-guidance (1)
- CT-guided interventions (1)
- Calcium (1)
- Cancer Staging (1)
- Cancer check up (1)
- Cancer staging (1)
- Carcinoma, Ductal, Breast (1)
- Cardiovascular diseases (1)
- Cardiovascular magnetic resonance (1)
- Cell binding (1)
- Cell staining (1)
- Chemoembolization (1)
- Children (1)
- Chondral Lesion (1)
- Cochlear implantation (1)
- Cohort studies (1)
- Colchicum (1)
- Computed tomography imaging (1)
- Computed tomography pulmonary angiography (CTPA) (1)
- Computed tomography, X-ray (1)
- Cone-beam computed tomography (1)
- Congenital (1)
- Contrast agent (1)
- Diagnostic differentiation (1)
- Diagnostic imaging (1)
- Diagnostic markers (1)
- Diffusion magnetic resonance imaging (1)
- Dual-Source CT (1)
- Dual-energy computed tomography (1)
- Dumon stents (1)
- Edema (1)
- Electric stimulation (1)
- Estrogen Receptor Modulators (1)
- Exudates and transudates (1)
- Facial nerve (1)
- Feasibility studies (1)
- Fetal heart (1)
- First experience with patients (1)
- Flow cytometry (1)
- Gadobutrol (1)
- Gadopentate dimeglumine (1)
- Goserelin (1)
- Groin pain (1)
- HCC (1)
- Heart defects (1)
- Herniated disk (1)
- Image processing (1)
- Image processing (computer-assisted) (1)
- In-TIPS thrombosis (1)
- Inguinal hernia (1)
- Inguinal pain (1)
- Intensive care units (1)
- Interventional oncological treatment (1)
- Intervertebral disc displacement (1)
- Kupffer cells (1)
- LNS (1)
- Laser interstitial thermal therapy (1)
- Laser navigation system (1)
- Lateral recess stenosis (1)
- Lipidol (1)
- Lipiodol (1)
- Liver (1)
- Local control (1)
- Low back pain (1)
- Lumbar spinal canal stenosis (1)
- Lumbar spine (1)
- Lung neoplasms (1)
- Lymphangioleiomyomatosis (1)
- MEDIC (1)
- Machine learning (1)
- Macrophages (1)
- Mastoiditis (1)
- Medical Oncology (1)
- Medical research (1)
- Metastasis (1)
- Mitomycin C (1)
- Mouse models (1)
- Multidetector Computed Tomography (1)
- Multiparametric MRI (1)
- Myocardial perfusion (1)
- Myocardial segmentation (1)
- Myocarditis (1)
- Necrotic area (1)
- Noninferiority (1)
- Nonpenetrating (1)
- Oncology (1)
- Osteoporotic fractures (1)
- Oswestry Disability Score (1)
- PSA screening (1)
- PSA-Screening (1)
- Patellofemoral Joint (1)
- Percutaneous (1)
- Phantom study (1)
- Phantoms (imaging) (1)
- Physics (1)
- Portal (1)
- Positron emission tomography (1)
- Preclinical research (1)
- Predictive markers (1)
- Preventive medicine (1)
- Prognostic markers (1)
- Prostata-specific antigen (1)
- Prostataspezifisches Antigen (1)
- Prostate cancer (1)
- Prävention (1)
- Quantitative Imaging (1)
- Radiology (1)
- Renal lesions (1)
- Response (1)
- Retrospective studies (1)
- Retrospective study (1)
- STIR (1)
- Shunt (1)
- Spinal fractures (1)
- Spinal injuries (1)
- Static MRI (1)
- Sub-segmentation (1)
- Survival (1)
- Survival data (1)
- TACE (1)
- TIPS (1)
- Temporomandibular joint (1)
- Temporomandibular joint dysfunction (1)
- Thrombosis (1)
- Tomography (1)
- Transjugular Intrahepatic Portosystemic Shunt (1)
- Translational research (1)
- Treatment outcome (1)
- Truncus arteriosus (1)
- Tumor volume (1)
- UWB diagnostics (1)
- Vaccination (1)
- Vasculitis (1)
- Vertebral body (1)
- Virtual noncalcium reconstructions (1)
- Vorsorgeuntersuchung (1)
- Wounds (1)
- X-ray computed (1)
- abdominal imaging (1)
- airway (1)
- amino acids (1)
- aortic stenosis (1)
- beads (1)
- biopsy (1)
- cardiac magnetic resonance (1)
- cardiac remodeling (1)
- chronic liver disease (CLD) (1)
- cisplatin (1)
- colorectal cancer (1)
- colorectal cancer (CRC) (1)
- colorectal cancer liver metastases (CRLM) (1)
- computer tomography (1)
- computer-assisted (1)
- cone-beam computed tomography (CBCT) (1)
- cone-beam computer tomography (1)
- conventional/traditional transarterial chemoembolization (cTACE) (1)
- critical care unit (1)
- critical ill patients (1)
- denervation (1)
- diagnostic imaging (1)
- drug-eluting beads TACE (DEB-TACE) (1)
- dual-energy (1)
- electromagnetic navigation bronchoscopy (EMN, ENB) (1)
- heart failure (1)
- hepatocellular carcinoma (HCC) (1)
- high-pitch (1)
- imaging (1)
- interventional radiology (1)
- intraarterial therapy (1)
- intratumoral (1)
- irinotecan-loaded drug-eluting beads TACE (DEBIRI-TACE) (1)
- laser-induced thermotherapy (1)
- lipiodol (1)
- liver metastases (1)
- livermetastases of colorectal cancer (1)
- locoregional chemotherapy (1)
- low-dose imaging (1)
- lung cancer (1)
- mantle cell lymphoma (1)
- microwave breast imaging (1)
- multidetector computed tomography (1)
- myocardial fibrosis (1)
- non‑Hodgkin's lymphoma (1)
- oval split ring resonator (1)
- overall survival (OS) (1)
- papilloma (1)
- patient study (1)
- percutaneous thermal ablation (1)
- peripheral blood stem cell transplant (1)
- portal vein (1)
- progression-free survival (PFS) (1)
- pulmonary hypertension (1)
- radiation (1)
- radiomics (1)
- rats (1)
- retuximab (1)
- scar (1)
- sepsis (1)
- sex‑determining region Y-box 11 (1)
- skin involvement (1)
- solitary pulmonary nodule (1)
- spine (1)
- stent (1)
- theranostics (1)
- thrombosis (1)
- tracheobronchomalacia (1)
- transarterial chemoembolization (TACE) (1)
- transbronchial biopsy (TBB) (1)
- tumor response (1)
- vertebroplasty (1)
- Öffentlichkeit (1)
Institute
- Medizin (69)
- Informatik und Mathematik (2)
- Informatik (1)
- Physik (1)
- Sonderforschungsbereiche / Forschungskollegs (1)
The exact pathophysiology of contrast-induced nephropathy (CIN) is not fully clarified, yet the osmotic characteristics of contrast media (CM) have been a significant focus in many investigations of CIN. Osmotic effects of CM specific to the kidney include transient decreases in blood flow, filtration fraction, and glomerular filtration rate. Potentially significant secondary effects include an osmotically induced diuresis with a concomitant dehydrating effect. Clinical experiences that have compared the occurrence of CIN between the various classes of CM based on osmolality have suggested a much less than anticipated advantage, if any, with a lower osmolality. Recent animal experiments actually suggest that induction of a mild osmotic diuresis in association with iso-osmolar agents tends to offset potentially deleterious renal effects of high viscosity-mediated intratubular CM stagnation.
Purpose: To evaluate the effect of chronic liver disease (CLD) in a multivariate analysis of associated risk factors in patients with hepatocellular carcinoma (HCC) using transarterial chemoembolization (TACE). Materials and methods: A total of 145 patients with HCC (99 men, 46 women; mean age: 63 years ±8.1; age range: 46-84 years) underwent 598 TACE procedures. The presence of CLD, number and location of lesions, tumor size, Child-Pugh score, vascularity, portal involvement and alpha fetoprotein value were analyzed using the multivariate regression model. Cox regression was used for survival analysis. Results: The median survival time was 26.7 months, and 78.6% of all treated lesions showed tumor responses. The presence of CLD (OR 2.12, P=0.004), Child-Pugh score B (OR 2.24, P=0.002), alpha fetoprotein >100ng/dl (OR 1.18, P<0.001), multinodularity (≥3 lesions) (OR 4.41, P=0.003), lesion size >5cm (OR 4.12, P=0.002) and hypervascularity (OR 7.94, P=0.003) were significant effective factors for a local response when analyzed using a multivariate logistic model. Multivariate survival analysis using Cox's regression model during the median follow-up period of 25 months (range: 1-42 months) demonstrated a significant difference in survival rates (P values <0.05). No significant difference in responses was noted for males, locations of lesions and portal involvements statistically. Conclusion: The presence of chronic liver disease as well as associated risk factors including Child-Pugh score B, alpha fetoprotein 100ng/dl, multinodularity (≥3 lesions), lesion size >5cm and hypervascularity statistically led to a significant effect in tumor response in HCC patients treated with TACE. Patient gender, location of lesion and involvement of portal vein showed no significant difference in response.
Background: Evaluation of automated attenuation-based tube potential selection and its impact on image quality and radiation dose in CT (computed tomography) examinations for cancer staging.
Methods: A total of 110 (59 men, 51 women) patients underwent chest-abdomen-pelvis CT examinations; 55 using a fixed tube potential of 120 kV/current of 210 Reference mAs (using CareDose4D), and 55 using automated attenuation-based tube potential selection (CAREkV) also using a current of 210 Reference mAs. This evaluation was performed as a single-centre, observer-blinded retrospective analysis. Image quality was assessed by two readers in consensus. Attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured or calculated for objective image evaluation. For the evaluation of radiation exposure, dose-length-product (DLP) values were compared and Size-specific dose estimates (SSDE) values were calculated.
Results: Diagnostic image quality was obtained from all patients. The median DLP (703.5 mGy · cm, range 390–2203 mGy · cm) was 7.9% lower when using the algorithm compared with the standard 120 kV protocol (median 756 mGy · cm, range 345–2267 mGy · cm). A reduction in potential to 100 kV occurred in 32 cases; therefore, these patients received significantly lower radiation exposure compared with the 120 kV protocol.
Conclusion: Automated attenuation-based tube potential selection produces good diagnostic image quality in chest-abdomen-pelvis CT and reduces the patient’s overall radiation dose by 7.9% compared to the standard 120 kV protocol.
Highly promising preclinical data obtained in cultured cells and in nude mice bearing xenografts contrast with the rather modest clinical efficacy of Polo-like kinase 1 (Plk1) inhibitors. In the present study, we investigated if Plk1 might be a suitable target in hepatocellular carcinoma (HCC) and if a genetically engineered mouse tumor model that well reflects the tumor cell and micro-environmental features of naturally occurring cancers might be suitable to study anti-Plk1 therapy. Analysis of Plk1 expression in human HCC samples confirmed that HCC express much higher Plk1 levels than the adjacent normal liver tissue. Inhibition of Plk1 by an adenovirus encoding for a short hairpin RNA against Plk1 or by the small-molecule inhibitor BI 2536 reduced the viability of HCC cell lines and inhibited HCC xenograft progression in nude mice. Treatment of transforming growth factor (TGF) α/c-myc bitransgenic mice with BI 2536 during hepatocarcinogenesis reduced the number of dysplastic foci and of Ki-67-positive cells within the foci, indicating diminished tumorigenesis. In contrast, BI 2536 had no significant effect on HCC progression in the transgenic mouse HCC model as revealed by magnetic resonance imaging. Measurement of BI 2536 by mass spectrometry revealed considerably lower BI 2536 levels in HCC compared with the adjacent normal liver tissue. In conclusion, low intratumoral levels are a novel mechanism of resistance to the Plk1 inhibitor BI 2536. Plk1 inhibitors achieving sufficient intratumoral levels are highly promising in HCC treatment.
This study included 30 patients with diagnosed rheumatoid arthritis (RA) and 30 test subjects without RA (control group). The objective of the study was to examine both groups for the presence of temporomandibular disorders (TMD) and morphological changes of the temporomandibular joint (TMJ). All individuals were examined using a systematic detailed clinical TMD examination as well as magnetic resonance imaging (MRI). The clinical TMD examination yielded significant differences between the RA patients and the control group concerning crepitus of the TMJ, and palpation tenderness of the masticatory muscles as well as the unassisted mandibular opening. The evaluation of the MRI images for the RA group showed significantly more frequent deformations of the condyle, osteophyte formations and erosions in the condylar compacta, and degenerative changes in the spongiosa. Increased intra-articular accumulation of synovial liquid and signs of inflammatory changes of the spongiosa were only found in the RA group. Statistical analysis showed a significant correlation between crepitus and specific osteoarthrotic changes (MRI), respectively, and between crepitus and a complete anterior disk displacement without reduction (MRI). The duration of the RA disease correlated neither with the anamnestic and clinical dysfunction index by Helkimo nor with RA-specific MRI findings.
Tracheomalacia or tracheobronchomalacia (TM or TBM) is a common problem especially for elderly patients often unfit for surgical techniques. Several surgical or minimally invasive techniques have already been described. Stenting is one option but in general long-time stenting is accompanied by a high complication rate. Stent removal is more difficult in case of self-expandable nitinol stents or metallic stents in general in comparison to silicone stents. The main disadvantage of silicone stents in comparison to uncovered metallic stents is migration and plugging. We compared the operation time and in particular the duration of a sufficient Dumon stent fixation with different techniques in a patient with severe posttracheotomy TM and strongly reduced mobility of the vocal cords due to Parkinson’s disease. The combined approach with simultaneous Dumon stenting and endoluminal transtracheal externalized suture under cone-beam computer tomography guidance with the Berci needle was by far the fastest approach compared to a (not performed) surgical intervention, or even purely endoluminal suturing through the rigid bronchoscope. The duration of the endoluminal transtracheal externalized suture was between 5 minutes and 9 minutes with the Berci needle; the pure endoluminal approach needed 51 minutes. The alternative of tracheobronchoplasty was refused by the patient. In general, 180 minutes for this surgical approach is calculated. The costs of the different approaches are supposed to vary widely due to the fact that in Germany 1 minute in an operation room costs on average approximately 50–60€ inclusive of taxes. In our own hospital (tertiary level), it is nearly 30€ per minute in an operation room for a surgical approach. Calculating an additional 15 minutes for patient preparation and transfer to wake-up room, therefore a total duration inside the investigation room of 30 minutes, the cost per flexible bronchoscopy is per minute on average less than 6€. Although the Dumon stenting requires a set-up with more expensive anesthesiology accompaniment, which takes longer than a flexible investigation estimated at 1 hour in an operation room, still without calculation of the costs of the materials and specialized staff that the surgical approach would consume at least 3,000€ more than a minimally invasive approach performed with the Berci needle. This difference is due to the longer time of the surgical intervention which is calculated at approximately 180 minutes in comparison to the achieved non-surgical approach of 60 minutes in the operation suite.
Objective: To evaluate two ultrafast cone-beam CT (UF-CBCT) imaging protocols with different acquisition and injection parameters regarding image quality and required contrast media during image-guided hepatic transarterial chemoembolization (TACE).
Methods: In 80 patients (male: 46, female: 34; mean age: 56.8 years; range: 33–83) UF-CBCT was performed during TACE for intraprocedural guidance. Imaging was performed using two ultrafast CBCT acquisition protocols with different acquisition and injection parameters (imaging protocol 1: acquisition time 2.54 s, and contrast 6 mL with 3 s delay; imaging protocol 2: acquisition time 2.72 s, and contrast 7 mL with 6 s delay). Image evaluation was performed with both qualitative and quantitative methods. Contrast injection volume and dose parameters were compared using values from the literature.
Results: Imaging protocol 2 provided significantly better (P < 0.05) image quality than protocol 1 at the cost of slightly higher contrast load and patient dose. Imaging protocol 1 provided good contrast perfusion but it mostly failed to delineate the tumors (P < 0.05). On the contrary, imaging protocol 2 showed excellent enhancement of hepatic parenchyma, tumor, and feeding vessels.
Conclusion: Tumor delineation, visualization of hepatic parenchyma, and feeding vessels are clearly possible using imaging protocol 2 with ultrafast CBCT imaging. A reduction of required contrast volume and patient dose were achieved due to the ultrafast CBCT imaging.
Objectives: The aim of our study was to find out how much energy is applicable in second-generation dual source high-pitch computed tomography (CT) in imaging of the abdomen.
Materials and methods: We examined an upper abdominal phantom using a Somatom Definition Flash CT-Scanner (Siemens, Forchheim, Germany). The study protocol consisted of a scan-series at 100 kV and 120 kV. In each scan series we started with a pitch of 3.2 and reduced it in steps of 0.2, until a pitch of 1.6 was reached. The current was adjusted to the maximum the scanner could achieve. Energy values, image noise, image quality, and radiation exposure were evaluated.
Results: For a pitch of 3.2 the maximum applicable current was 142 mAs at 120 kV and in 100 kV the maximum applicable current was 114 mAs. For conventional abdominal imaging, current levels of 200 to 260 mAs are generally used. To achieve similar current levels, we had to decrease the pitch to 1.8 at 100 kV - at this pitch we could perform our imaging at 204 mAs. At a pitch of 2.2 in 120 kV we could apply a current of 206 mAs.
Conclusion: We conclude our study by stating that if there is a need for a higher current, we have to reduce the pitch. In a high-pitch dual source CT, we always have to remember where our main focus is, so we can adjust the pitch to the energy we need in the area of the body that has to be imaged, to find answers to the clinical question being raised.
Novel therapies for lung cancer are being explored nowadays with local therapies being the tip of the arrow. Intratumoral chemotherapy administration and local microwave ablation have been investigated in several studies. It has been previously proposed that lipiodol has the ability to modify the microenvironment matrix. In our current study we investigated this theory in BALBC mice. In total 160 BALBC mice were divided in eight groups: a) control, b) cisplatin, c) microwave, d) microwave and lipiodol, e) cisplatin and lipiodol, f) microwave and cisplatin, g) lipiodol and h) lipiodol, cisplatin and microwave. Lewis lung carcinoma cell lines (106) were injected into the right back leg of each mouse. After the 8th day, when the tumor volume was about 100mm3 the therapy application was initiated, once per week for four weeks. Magnetic resonance imaging was performed for each tumor when a mouse died or when sacrificed if they were still alive by the end of the experiment (8-Canal multifunctional spool; NORAS MRI products, Gmbh, Germany). Imaging and survival revealed efficient tumor apoptosis for the groups b,c,d,e and f. However; severe toxicity was observed in group h and no follow up was available for this group after the second week of therapy administration. Lipiodol in its current form does assist in a more efficient way the distribution of cisplatin, as the microwave apoptotic effect. Future modification of lipiodol might provide a more efficient method of therapy enhancement. Combination of drug and microwave ablation is possible and has an efficient apoptotic effect.
Objective: To investigate the accuracy, efficiency and radiation dose of a novel laser navigation system (LNS) compared to those of free-handed punctures on computed tomography (CT).
Materials and methods: Sixty punctures were performed using a phantom body to compare accuracy, timely effort, and radiation dose of the conventional free-handed procedure to those of the LNS-guided method. An additional 20 LNS-guided interventions were performed on another phantom to confirm accuracy. Ten patients subsequently underwent LNS-guided punctures.
Results: The phantom 1-LNS group showed a target point accuracy of 4.0 ± 2.7 mm (freehand, 6.3 ± 3.6 mm; p = 0.008), entrance point accuracy of 0.8 ± 0.6 mm (freehand, 6.1 ± 4.7 mm), needle angulation accuracy of 1.3 ± 0.9° (freehand, 3.4 ± 3.1°; p < 0.001), intervention time of 7.03 ± 5.18 minutes (freehand, 8.38 ± 4.09 minutes; p = 0.006), and 4.2 ± 3.6 CT images (freehand, 7.9 ± 5.1; p < 0.001). These results show significant improvement in 60 punctures compared to freehand. The phantom 2-LNS group showed a target point accuracy of 3.6 ± 2.5 mm, entrance point accuracy of 1.4 ± 2.0 mm, needle angulation accuracy of 1.0 ± 1.2°, intervention time of 1.44 ± 0.22 minutes, and 3.4 ± 1.7 CT images. The LNS group achieved target point accuracy of 5.0 ± 1.2 mm, entrance point accuracy of 2.0 ± 1.5 mm, needle angulation accuracy of 1.5 ± 0.3°, intervention time of 12.08 ± 3.07 minutes, and used 5.7 ± 1.6 CT-images for the first experience with patients.
Conclusion: Laser navigation system improved accuracy, duration of intervention, and radiation dose of CT-guided interventions.
Microwave sensors in medical environments play a significant role due to the contact-less and non-invasive sensing mechanism to determine dielectric properties of tissue. In this work, a theranostic sensor based on Split Ring Resonators (SRRs) is presented that provides two operation modes to detect and treat tumor cells, exemplary in the liver. For the detection mode, resonance frequency changes due to abnormalities are evaluated, and in the treatment mode, microwave ablation is performed. The planar sensor structure can be integrated into a needle like a surgery tool that evokes challenges concerning size limitations and biocompatibility. To meet the size requirements and provide a reasonable operating frequency, properties of oval shaped SRRs are investigated. By elongating the radius of the SRR in one direction, the resonance frequency can be decreased significantly compared to circular SRR by a factor of two below 12 GHz. In order to validate the detection and treatment characteristics of the sensor, full wave simulations and measurements are examined. Clear resonance shifts are detected for loading the sensor structures with phantoms mimicking healthy and malignant tissue. For treatment mode evaluation, ex vivo beef liver tissue was ablated leading to a lesion zone 1.2 cm × 1 cm × 0.3 cm with a three minute exposure of maximum 2.1 W
Background: Computed tomography (CT) low-dose (LD) imaging is used to lower radiation exposure, especially in vascular imaging; in current literature, this is mostly on latest generation high-end CT systems.
Purpose: To evaluate the effects of reduced tube current on objective and subjective image quality of a 15-year-old 16-slice CT system for pulmonary angiography (CTPA).
Material and Methods: CTPA scans from 60 prospectively randomized patients (28 men, 32 women) were examined in this study on a 15-year-old 16-slice CT scanner system. Standard CT (SD) settings were 100 kV and 150 mAs, LD settings were 100 kV and 50 mAs. Attenuation of the pulmonary trunk, various anatomic landmarks, and image noise were quantitatively measured; contrast-to-noise ratios (CNR) and signal-to-noise ratios (SNR) were calculated. Three independent blinded radiologists subjectively rated each image series using a 5-point grading scale.
Results: CT dose index (CTDI) in the LD series was 66.46% lower compared to the SD settings (2.49 ± 0.55 mGy versus 7.42 ± 1.17 mGy). Attenuation of the pulmonary trunk showed similar results for both series (SD 409.55 ± 91.04 HU; LD 380.43 HU ± 93.11 HU; P = 0.768). Subjective image analysis showed no significant differences between SD and LD settings regarding the suitability for detection of central and peripheral PE (central SD/LD, 4.88; intra-class correlation coefficients [ICC], 0.894/4.83; ICC, 0.745; peripheral SD/LD, 4.70; ICC, 0.943/4.57; ICC, 0.919; all P > 0.4).
Conclusion: The LD protocol, on a 15-year-old CT scanner system without current high-end hardware or post-processing tools, led to a dose reduction of approximately 67% with similar subjective image quality and delineation of central and peripheral pulmonary arteries.
BACKGROUND: Evaluation of latest generation automated attenuation-based tube potential selection (ATPS) impact on image quality and radiation dose in contrast-enhanced chest-abdomen-pelvis computed tomography examinations for gynaecologic cancer staging.
METHODS: This IRB approved single-centre, observer-blinded retrospective study with a waiver for informed consent included a total of 100 patients with contrast-enhanced chest-abdomen-pelvis CT for gynaecologic cancer staging. All patients were examined with activated ATPS for adaption of tube voltage to body habitus. 50 patients were scanned on a third-generation dual-source CT (DSCT), and another 50 patients on a second-generation DSCT. Predefined image quality setting remained stable between both groups at 120 kV and a current of 210 Reference mAs. Subjective image quality assessment was performed by two blinded readers independently. Attenuation and image noise were measured in several anatomic structures. Signal-to-noise ratio (SNR) was calculated. For the evaluation of radiation exposure, CT dose index (CTDIvol) values were compared.
RESULTS: Diagnostic image quality was obtained in all patients. The median CTDIvol (6.1 mGy, range 3.9-22 mGy) was 40 % lower when using the algorithm compared with the previous ATCM protocol (median 10.2 mGy · cm, range 5.8-22.8 mGy). A reduction in potential to 90 kV occurred in 19 cases, a reduction to 100 kV in 23 patients and a reduction to 110 kV in 3 patients of our experimental cohort. These patients received significantly lower radiation exposure compared to the former used protocol.
CONCLUSION: Latest generation automated ATPS on third-generation DSCT provides good diagnostic image quality in chest-abdomen-pelvis CT while average radiation dose is reduced by 40 % compared to former ATPS protocol on second-generation DSCT.
Purpose: To determine the value of the 2D multiple-echo data image combination (MEDIC) sequence relative to the short-tau inversion recovery (STIR) sequence regarding the depiction of chondral lesions in the patellofemoral joint.
Materials and methods: During a period of 6 month patients with acute pain at the anterior aspect of the knee, joint effusion and suspected chondral lesion defect in the patellofemoral joint underwent MRI including axial MEDIC and STIR imaging. Patients with chondral lesions in the patellofemoral joint on at least one sequence were included. The MEDIC and STIR sequence were quantitatively compared regarding the patella cartilage-to-effusion contrast-to-noise ratio (CNR) and qualitatively regarding the depiction of chondral lesions independently scored by two radiologists on a 3-point scale (1 = not depicted; 2 = blurred depicted; 3 = clearly depicted) using the Wilcoxon-Mann-Whitney-Test. For the analysis of inter-observer agreement the Cohen's Weighted Kappa test was used.
Results: 30 of 58 patients (male: female, 21:9; age: 44 ± 12 yrs) revealed cartilage lesions (fissures, n = 5 including fibrillation; gaps, n = 15; delamination, n = 7; osteoarthritis, n = 3) and were included in this study. The STIR-sequence was significantly (p < 0.001) superior to the MEDIC-sequence regarding both, the patella cartilage-to-effusion CNR (mean CNR: 232 ± 61 vs. 40 ± 16) as well as the depiction of chondral lesion (mean score: 2.83 ± 0.4 vs. 1.75 ± 0.7) with substantial inter-observer agreement in the rating of both sequences (κ = 0.76–0.89).
Conclusion: For the depiction of chondral lesions in the patellofemoral joint, the axial STIR-sequence should be chosen in preference to the axial MEDIC-sequence.
Mantle cell lymphoma (MCL) is a unique type of B-cell non-Hodgkin's lymphoma, which very rarely exhibits skin involvement. We herein describe the case of a 55-year-old woman, who initially presented with a nodular mass of the right infraorbital region. On histological analysis of the subcutaneous tissue, a diffuse neoplastic cell infiltration was identified, composed of medium‑sized lymphoid cells with irregular nuclei, which was diagnosed as MCL. The tumor cells were positive for CD5, CD20, CD79a, cyclin D1 and sex‑determining region Y-box 11, but negative for CD10 and CD23. Our patient received six cycles of R‑CHOP chemotherapy and intrathecal methotrexate as central nervous system prophylaxis. However, the patient relapsed 1 year later and was treated with two cycles of R‑DHAP and one cycle of intrathecal methotrexate. After achieving partial remission, the patient was consolidated with peripheral blood stem cell transplantation using the BEAM conditioning regime. While prior case studies suggest that skin invasion by MCL is associated with a poor prognosis, our patient remains alive almost 4 years after the initial presentation. Skin involvement as a first sign of systemic MCL is very rare and must be considered.
Background: Computed-tomography-guided interventions are attractive for tissue sampling of paediatric tumor lesions; however, it comes with exposure to ionizing radiation. The aim of this study was to analyse the radiation dose, accuracy and speed of CT-guided interventions in paediatric patient cohort.
Methods: We retrospectively reviewed CT-guided interventions over a 10 -year period in 65 children. The intervention site consisted of bones in 38, chest (lung) in 15 and abdomen (liver, lymph nodes) in 12 cases. Radiation dose and duration of the procedures were analysed. The statistical analysis was performed using dedicated statistical software (BiAS 8.3.6 software, Epsilon Verlag, North Hasted).
Results: All interventions were performed successfully. Mean target access path to lesion within the patients was 6.0 cm (min 3.5 cm, max 11.2 cm). Time duration to complete intervention was 25:15 min (min 17:03 min, max 43:00 min). The dose-length product (DLP) of intervention scan was 29.5 mGy · cm (min 6 mGy · cm, max 85 mGy · cm) with the lowest dose for biopsies in the region of the chest (p = 0.04).
Conclusions: With justified indications, CT-guided paediatric interventions are safe, effective and can be performed both, with short intervention times and low radiation exposure.
Background: Computed tomography of the head (HCT) is a widely used diagnostic tool, especially for emergency and trauma patients. However, the diagnostic yield and outcomes of HCT for patients on medical intensive care units (MICUs) are largely unknown.
Methods: We retrospectively evaluated all head CTs from patients admitted to a single-center MICU during a 5-year period for CT indications, diagnostic yield, and therapeutic consequences. Uni- and multivariate analyses for the evaluation of risk factors for positive head CT were conducted.
Results: Six hundred ninety (18.8%) of all patients during a 5-year period underwent HCT; 78.7% had negative CT results, while 21.3% of all patients had at least 1 new pathological finding. The main indication for acquiring CT scan of the head was an altered mental state (AMS) in 23.5%, followed by a new focal neurology in 20.7% and an inadequate wake up after stopping sedation in 14.9% of all patients. The most common new finding was intracerebral bleeding in 6.4%. In 6.7%, the CT scan itself led to a change of therapy of any kind. Admission after resuscitation or a new focal neurology were independent predictors of a positive CT. Psychic alteration and AMS were both independent predictors of a higher chance of a negative head CT. Positive HCT during MICU is an independent predictor of lower survival.
Conclusions: New onset of focal neurologic deficit seems to be a good predictor for a positive CT, while AMS and psychic alterations seem to be very poor predictors. A positive head CT is an independent predictor of death for MICU patients.
Correlation of lumbar lateral recess stenosis in magnetic resonance imaging and clinical symptoms
(2017)
Aim: To assess the correlation of lateral recess stenosis (LRS) of lumbar segments L4/5 and L5/S1 and the Oswestry Disability Index (ODI).
Methods: Nine hundred and twenty-seven patients with history of low back pain were included in this uncontrolled study. On magnetic resonance images (MRI) the lateral recesses (LR) at lumbar levels L4/5 and L5/S1 were evaluated and each nerve root was classified into a 4-point grading scale (Grade 0-3) as normal, not deviated, deviated or compressed. Patient symptoms and disability were assessed using ODI. The Spearman’s rank correlation coefficient was used for statistical analysis (P < 0.05).
Results: Approximately half of the LR revealed stenosis (grade 1-3; 52% at level L4/5 and 42% at level L5/S1) with 2.2% and 1.9% respectively reveal a nerve root compression. The ODI score ranged from 0%-91.11% with an arithmetic mean of 34.06% ± 16.89%. We observed a very weak statistically significant positive correlation between ODI and LRS at lumbar levels L4/5 and L5/S1, each bilaterally (L4/5 left: rho < 0.105, P < 0.01; L4/5 right: rho < 0.111, P < 0.01; L5/S1 left: rho 0.128, P < 0.01; L5/S1 right: rho < 0.157, P < 0.001).
Conclusion: Although MRI is the standard imaging tool for diagnosing lumbar spinal stenosis, this study showed only a weak correlation of LRS on MRI and clinical findings. This can be attributed to a number of reasons outlined in this study, underlining that imaging findings alone are not sufficient to establish a reliable diagnosis for patients with LRS.
Background: The management of intraductal papilloma without atypia (IDP) in breast needle biopsy remains controversial. This study investigates the upgrade rate of IDP to carcinoma and clinical and radiologic features predictive of an upgrade. Methods: Patients with a diagnosis of IDP on image-guided (mammography, ultrasound, magnetic resonance imaging) core needle or vacuum-assisted biopsy and surgical excision of this lesion at a certified breast center between 2007 and 2017 were included in this institutional review board-approved retrospective study. Appropriate statistical tests were performed to assess clinical and radiologic characteristics associated with an upgrade to malignancy at excision. Results: For 60 women with 62 surgically removed IDPs, the upgrade rate to malignancy was 16.1% (10 upgrades, 4 invasive ductal carcinoma, 6 ductal carcinoma in situ). IDPs with upgrade to carcinoma showed a significantly greater distance to the nipple (63.5 vs. 36.8 mm; p = 0.012). No significant associations were found between upgrade to carcinoma and age, menopausal status, lesion size, microcalcifications, BI-RADS descriptors, initial BI-RADS category, and biopsy modality. Conclusion: The upgrade rate at excision for IDPs diagnosed with needle biopsy was higher than expected according to some guideline recommendations. Observation only might not be appropriate for all patients with IDP, particularly for those with peripheral IDP.
Background: To evaluate survival data and local tumor control after transarterial chemoembolization in two groups with different embolization protocols for the treatment of HCC patients.
Methods: Ninty-nine patients (mean age: 63.6 years), 78 male (78.8%) with HCC were repeatedly treated with chemoembolization in 4-week-intervals. Eighty-eight patients had BCLC-Stage-B and in 11 patients, chemoembolization was performed for bridging (BCLC-Stage-A). In total, 667 chemoembolization treatments were performed (mean 6.7 treatments/patient). The administered chemotherapeutic agent included mitomycin. For embolization, lipiodol only (n = 51;51.5%; mean age 63.8 years; 38 male), or lipiodol plus degradable starch microspheres (DSM) (n = 48; 48.5%; mean age 63.4 years; 40 male) were used. The local tumor response was assessed by MRI using Response Evaluation Criteria in Solid Tumors 1.1 (RECIST 1.1). Patient survival times were evaluated using Kaplan-Meier curves and log-rank tests.
Results: The local tumor control in the lipiodol-group was: PR (partial response) in 11 (21.6%), SD (stable disease) in 32 (62.7%) and PD (progressive disease) in 8 cases (15.7%). In the lipiodol-DSM-group, PR was seen in 14 (29.2%), SD in 22 (45.8%), and PD in 12 (25.0%) individuals (p = 0.211). The median survival of patients after chemoembolization with lipiodol was 25 months and in the lipiodol-DSM-group 28 months (p = 0.845).
Conclusion: Our data suggest a slight benefit of the use of lipiodol and DSM in comparison of using lipiodol only for chemoembolization of HCC in terms of local tumor control and survival data, this trend did not reach the level of significance.
Tumor progression largely depends on the presence of alternatively polarized (M2) tumor-associated macrophages (TAMs), whereas the classical M1-polarized macrophages can promote anti-tumorigenic immune responses. Thus, selective inhibition of M2-TAMs is a desirable anti-cancer approach in highly resistant tumor entities such as hepatocellular carcinoma (HCC) or breast cancer. We here examined whether a peptide that selectively binds to and is internalized by in vitro-differentiated murine M2 macrophages as compared to M1 macrophages, termed M2pep, could be used to selectively target TAMs in HCC and breast carcinoma. We confirmed selectivity of M2pep for in vitro M2 polarized macrophages. Upon incubation of suspended mixed 4T1 tumor cells with M2pep, high amounts of the TAMs were found to be associated with M2pep, whereas in mixed tumor cell suspensions from two HCC mouse models, M2pep showed only low-degree binding to TAMs. M2pep also showed low-degree targeting of liver macrophages. This indicates that the TAMs in different tumor entities show different targeting of M2pep and that M2pep is a very promising approach to develop selective M2-TAM-targeting in tumor entities containing M2-TAMs with significant amounts of the so far elusive M2pep receptor(s).
Hemispherical and cylindrical antenna arrays are widely used in radar-based and tomography-based microwave breast imaging systems. Based on the dielectric contrast between healthy and malignant tissue, a three-dimensional image could be formed to locate the tumor. However, conventional X-ray mammography as the golden standard in breast cancer screening produces two-dimensional breast images so that a comparison between the 3D microwave image and the 2D mammogram could be difficult. In this paper, we present the design and realisation of a UWB breast imaging prototype for the frequency band from 1 to 9 GHz. We present a refined system design in light of the clinical usage by means of a planar scanning and compare microwave images with those obtained by X-ray mammography. Microwave transmission measurements were processed to create a two-dimensional image of the breast that can be compared directly with a two-dimensional mammogram. Preliminary results from a patient study are presented and discussed showing the ability of the proposed system to locate the tumor.
A case of Lymphangioleiomyomatosis (LAM) of the lung in a patient with a history of breast cancer
(2019)
Background: Lymphangioleiomyomatosis (LAM) is a rare progressive cystic and nodular disease of the lung characterized by smooth muscle cell proliferation. LAM predominantly affects young premenopausal women. This report is of a case of LAM presenting in a 47-year-old woman with a past history of breast cancer and discusses the possibility of an association between the two conditions.
Case report: A 47-year-old woman presented as an emergency with an exacerbation of a four-month history of shortness of breath and dry cough. Her symptoms began following the start of anti-hormonal treatment with letrozole and goserelin acetate for a moderately differentiated (grade 2) invasive ductal carcinoma of the breast (pT2, pN0, M0) which was positive for expression of estrogen receptor (ER+), progesterone receptor (PR+), and human epidermal growth factor receptor 2 (HER2+). Until the previous four months, she had breast-conserving treatment with radiotherapy and tamoxifen therapy. Following hospital admission, she was found to be in type I respiratory failure. Chest X-ray, lung computed tomography (CT), and positron-emission tomography (PET) showed diffuse cystic and nodular lung lesions, consistent with a diagnosis of LAM, and antihormonal therapy was discontinued. She developed pericarditis that was treated with the anti-inflammatory agent, colchicine. Treatment with letrozole and sirolimus improved her respiratory symptoms.
Conclusions: A rare case of LAM is presented in a woman with a recent history of breast cancer. Because both tumors were hormone-dependent, this may support common underlying gene associations and signaling pathways between the two types of tumor.
Background: Myocardial perfusion with cardiovascular magnetic resonance (CMR) imaging is an established diagnostic test for evaluation of myocardial ischaemia. For quantification purposes, the 16 segment American Heart Association (AHA) model poses limitations in terms of extracting relevant information on the extent/severity of ischaemia as perfusion deficits will not always fall within an individual segment, which reduces its diagnostic value, and makes an accurate assessment of outcome data or a result comparison across various studies difficult. We hypothesised that division of the myocardial segments into epi- and endocardial layers and a further circumferential subdivision, resulting in a total of 96 segments, would improve the accuracy of detecting myocardial hypoperfusion. Higher (sub-)subsegmental recording of perfusion abnormalities, which are defined relatively to the normal reference using the subsegment with the highest value, may improve the spatial encoding of myocardial blood flow, based on a single stress perfusion acquisition. Objective: A proof of concept comparison study of subsegmentation approaches based on transmural segments (16 AHA and 48 segments) vs. subdivision into epi- and endocardial (32) subsegments vs. further circumferential subdivision into 96 (sub-)subsegments for diagnostic accuracy against invasively defined obstructive coronary artery disease (CAD). Methods: Thirty patients with obstructive CAD and 20 healthy controls underwent perfusion stress CMR imaging at 3 T during maximal adenosine vasodilation and a dual bolus injection of 0.1mmol/kg gadobutrol. Using Fermi deconvolution for blood flow estimation, (sub-)subsegmental values were expressed relative to the (sub)subsegment with the highest flow. In addition, endo−/epicardial flow ratios were calculated based on 32 and 96 (sub-)subsegments. A receiver operating characteristics (ROC) curve analysis was performed to compare the diagnostic performance of discrimination between patients with CAD and healthy controls. Observer reproducibility was assessed using Bland-Altman approaches. Results: Subdivision into more and smaller segments revealed greater accuracy for #32, #48 and # 96 compared to the standard #16 approach (area under the curve (AUC): 0.937, 0.973 and 0.993 vs 0.820, p<0.05). The #96-based endo−/epicardial ratio was superior to the #32 endo−/epicardial ratio (AUC 0.979, vs. 0.932, p<0.05). Measurements for the #16 model showed marginally better reproducibility compared to #32, #48 and #96 (mean difference± standard deviation: 2.0±3.6 vs. 2.3±4.0 vs 2.5±4.4 vs. 4.1±5.6). Conclusions: Subsegmentation of the myocardium improves diagnostic accuracy and facilitates an objective cutoff-based description of hypoperfusion, and facilitates an objective description of hypoperfusion, including the extent and severity of myocardial ischaemia. Quantification based on a single (stress-only) pass reduces the overall amount of gadolinium contrast agent required and the length of the overall diagnostic study.
Background: Bone age (BA) assessment performed by artificial intelligence (AI) is of growing interest due to improved accuracy, precision and time efficiency in daily routine. The aim of this study was to investigate the accuracy and efficiency of a novel AI software version for automated BA assessment in comparison to the Greulich-Pyle method.
Methods: Radiographs of 514 patients were analysed in this retrospective study. Total BA was assessed independently by three blinded radiologists applying the GP method and by the AI software. Overall and gender-specific BA assessment results, as well as reading times of both approaches, were compared, while the reference BA was defined by two blinded experienced paediatric radiologists in consensus by application of the Greulich-Pyle method.
Results: Mean absolute deviation (MAD) and root mean square deviation (RSMD) were significantly lower between AI-derived BA and reference BA (MAD 0.34 years, RSMD 0.38 years) than between reader-calculated BA and reference BA (MAD 0.79 years, RSMD 0.89 years; p < 0.001). The correlation between AI-derived BA and reference BA (r = 0.99) was significantly higher than between reader-calculated BA and reference BA (r = 0.90; p < 0.001). No statistical difference was found in reader agreement and correlation analyses regarding gender (p = 0.241). Mean reading times were reduced by 87% using the AI system.
Conclusions: A novel AI software enabled highly accurate automated BA assessment. It may improve efficiency in clinical routine by reducing reading times without compromising the accuracy compared with the Greulich-Pyle method.
Objectives: To analyze the performance of radiological assessment categories and quantitative computational analysis of apparent diffusion coefficient (ADC) maps using variant machine learning algorithms to differentiate clinically significant versus insignificant prostate cancer (PCa). Methods: Retrospectively, 73 patients were included in the study. The patients (mean age, 66.3 ± 7.6 years) were examined with multiparametric MRI (mpMRI) prior to radical prostatectomy (n = 33) or targeted biopsy (n = 40). The index lesion was annotated in MRI ADC and the equivalent histologic slides according to the highest Gleason Grade Group (GrG). Volumes of interest (VOIs) were determined for each lesion and normal-appearing peripheral zone. VOIs were processed by radiomic analysis. For the classification of lesions according to their clinical significance (GrG ≥ 3), principal component (PC) analysis, univariate analysis (UA) with consecutive support vector machines, neural networks, and random forest analysis were performed. Results: PC analysis discriminated between benign and malignant prostate tissue. PC evaluation yielded no stratification of PCa lesions according to their clinical significance, but UA revealed differences in clinical assessment categories and radiomic features. We trained three classification models with fifteen feature subsets. We identified a subset of shape features which improved the diagnostic accuracy of the clinical assessment categories (maximum increase in diagnostic accuracy ΔAUC = + 0.05, p < 0.001) while also identifying combinations of features and models which reduced overall accuracy. Conclusions: The impact of radiomic features to differentiate PCa lesions according to their clinical significance remains controversial. It depends on feature selection and the employed machine learning algorithms. It can result in improvement or reduction of diagnostic performance.
hintergrund: Männer in Deutschland sterben früher als Frauen und nehmen weniger häufig Krebsvorsorgeuntersuchungen wahr.
Fragestellung: Ziel war die prospektive Evaluation einer „Movember-Gesundheitsinitiative“ am Universitätsklinikum Frankfurt (UKF) im November 2019.
Methoden: Im Rahmen der „Movember-Gesundheitsinitiative“ wurde allen männlichen Mitarbeitern des UKF ab dem 45. Lebensjahr und bei erstgradiger familiärer Vorbelastung eines Prostatakarzinoms ab dem 40. Lebensjahr im November 2019 gemäß S3-Leitlinien der Deutschen Gesellschaft für Urologie (DGU) eine Prostatakarzinom-Vorsorgeuntersuchung angeboten.
Ergebnisse: Insgesamt nahmen 14,4 % der Mitarbeiter teil. Eine familiäre Vorbelastung gaben insgesamt 14,0 % Teilnehmer an. Das mediane Alter betrug 54 Jahre. Der mediane PSA(prostataspezifisches Antigen)-Wert lag bei 0,9 ng/ml, der mediane PSA-Quotient bei 30 %. Bei 5 % (n = 6) zeigte sich ein suspekter Tastbefund in der DRU (digital-rektale Untersuchung). Nach Altersstratifizierung (≤ 50 vs. > 50 Lebensjahre) zeigten sich signifikante Unterschiede im medianen PSA-Wert (0,7 ng/ml vs. 1,0 ng/ml, p < 0,01) und der bereits zuvor durchgeführten urologischen Vorsorge (12,1 vs. 42,0 %, p < 0,01). Vier Teilnehmer (3,3 %) zeigten erhöhte Gesamt-PSA-Werte. Bei 32,2 % der Teilnehmer zeigte sich mindestens ein kontrollbedürftiger Befund. Insgesamt wurden 6 Prostatabiopsien durchgeführt. Hierbei zeigte sich in einem Fall ein intermediate-risk Prostatakarzinom (Gleason 3 + 4, pT3a, pPn1, pNx, R0).
Schlussfolgerungung: Im Rahmen der UKF-Movember-Gesundheitsinitiative 2019 konnten durch ein Vorsorgeangebot 121 Männer für eine Prostatakrebs-Vorsorge inklusive PSA-Testung gewonnen werden. Auffällige/kontrollbedürftige Befunde zeigten sich bei 32,2 %. Bei einem Mitarbeiter wurde ein therapiebedürftiges Prostatakarzinom entdeckt und therapiert.
The aim of the study was to obtain volumetric data of the components of the inner ear using three-dimensional reconstruction of high-resolution cone-beam computed tomography (CBCT) images. Two hundred three CBCT image series of the temporal bone from 118 anatomically normal patients (55 women and 63 men; mean age: 49.4 ± 20.4 years) with different suspected disorders were included in this study. Normative volumetric measurements of the inner ear, the cochlea, the semicircular canals (SSC), and the vestibule were determined using a semi-automated reconstruction method of the Workstation. Volumetric measurements were successfully completed in all 118 patients. Mean inner ear, cochlear, and vestibule volumes were statistically significantly larger in males than in females on both sides (p < 0.001). Regarding the semicircular canals, no statistically significant (p = 0.053) volume difference was found. The difference between the volumes on both sides was not significant. No correlation between the patient’s age and the volume of the compartments was seen (p > 0.05). There was no significant difference between mean bony inner ear volumes when the clinical diagnoses were compared (p > 0.05 for all clinical diagnoses and volumes). Our study concluded that three-dimensional reconstruction and assessment of the volumetric measurements of the inner ear can be obtained using high-resolution CBCT imaging.
Simple Summary: Early and accurate diagnosis of breast cancer that has spread to other organs and tissues is crucial, as therapeutic decisions and outcome expectations might change. Computed tomography (CT) is often used to detect breast cancer’s spread, but this method has its weaknesses. The computer-assisted technique “radiomics” extracts grey-level patterns, so-called radiomic features, from medical images, which may reflect underlying biological processes. Our retrospective study therefore evaluated whether breast cancer spread can be predicted by radiomic features derived from iodine maps, an application on a new generation of CT scanners visualizing tissue blood flow. Based on 77 patients with newly diagnosed breast cancer, we found that this approach might indeed predict cancer spread to other organs/tissues. In the future, radiomics may serve as an additional tool for cancer detection and risk assessment.
Abstract: Dual-energy CT (DECT) iodine maps enable quantification of iodine concentrations as a marker for tissue vascularization. We investigated whether iodine map radiomic features derived from staging DECT enable prediction of breast cancer metastatic status, and whether textural differ- ences exist between primary breast cancers and metastases. Seventy-seven treatment-naïve patients with biopsy-proven breast cancers were included retrospectively (41 non-metastatic, 36 metastatic). Radiomic features including first-, second-, and higher-order metrics as well as shape descriptors were extracted from volumes of interest on iodine maps. Following principal component analysis, a multilayer perceptron artificial neural network (MLP-NN) was used for classification (70% of cases for training, 30% validation). Histopathology served as reference standard. MLP-NN predicted metastatic status with AUCs of up to 0.94, and accuracies of up to 92.6 in the training and 82.6 in the validation datasets. The separation of primary tumor and metastatic tissue yielded AUCs of up to 0.87, with accuracies of up to 82.8 in the training, and 85.7 in the validation dataset. DECT iodine map-based radiomic signatures may therefore predict metastatic status in breast cancer patients. In addition, microstructural differences between primary and metastatic breast cancer tissue may be reflected by differences in DECT radiomic features.
Dual-energy CT (DECT) has emerged into clinical routine as an imaging technique with unique postprocessing utilities that improve the evaluation of different body areas. The virtual non-calcium (VNCa) reconstruction algorithm has shown beneficial effects on the depiction of bone marrow pathologies such as bone marrow edema. Its main advantage is the ability to substantially increase the image contrast of structures that are usually covered with calcium mineral, such as calcified vessels or bone marrow, and to depict a large number of traumatic, inflammatory, infiltrative, and degenerative disorders affecting either the spine or the appendicular skeleton. Therefore, VNCa imaging represents another step forward for DECT to image conditions and disorders that usually require the use of more expensive and time-consuming techniques such as magnetic resonance imaging, positron emission tomography/CT, or bone scintigraphy. The aim of this review article is to explain the technical background of VNCa imaging, showcase its applicability in the different body regions, and provide an updated outlook on the clinical impact of this technique, which goes beyond the sole improvement in image quality.
Background: Dual-source dual-energy computed tomography (DECT) offers the potential for opportunistic osteoporosis screening by enabling phantomless bone mineral density (BMD) quantification. This study sought to assess the accuracy and precision of volumetric BMD measurement using dual-source DECT in comparison to quantitative CT (QCT). Methods: A validated spine phantom consisting of three lumbar vertebra equivalents with 50 (L1), 100 (L2), and 200 mg/cm3 (L3) calcium hydroxyapatite (HA) concentrations was scanned employing third-generation dual-source DECT and QCT. While BMD assessment based on QCT required an additional standardised bone density calibration phantom, the DECT technique operated by using a dedicated postprocessing software based on material decomposition without requiring calibration phantoms. Accuracy and precision of both modalities were compared by calculating measurement errors. In addition, correlation and agreement analyses were performed using Pearson correlation, linear regression, and Bland-Altman plots. Results: DECT-derived BMD values differed significantly from those obtained by QCT (p < 0.001) and were found to be closer to true HA concentrations. Relative measurement errors were significantly smaller for DECT in comparison to QCT (L1, 0.94% versus 9.68%; L2, 0.28% versus 5.74%; L3, 0.24% versus 3.67%, respectively). DECT demonstrated better BMD measurement repeatability compared to QCT (coefficient of variance < 4.29% for DECT, < 6.74% for QCT). Both methods correlated well to each other (r = 0.9993; 95% confidence interval 0.9984–0.9997; p < 0.001) and revealed substantial agreement in Bland-Altman plots. Conclusions: Phantomless dual-source DECT-based BMD assessment of lumbar vertebra equivalents using material decomposition showed higher diagnostic accuracy compared to QCT.
Background: This prospective randomized trial is designed to compare the performance of conventional transarterial chemoembolization (cTACE) using Lipiodol-only with additional use of degradable starch microspheres (DSM) for hepatocellular carcinoma (HCC) in BCLC-stage-B based on metric tumor response. Methods: Sixty-one patients (44 men; 17 women; range 44–85) with HCC were evaluated in this IRB-approved HIPPA compliant study. The treatment protocol included three TACE-sessions in 4-week intervals, in all cases with Mitomycin C as a chemotherapeutic agent. Multiparametric magnetic resonance imaging (MRI) was performed prior to the first and 4 weeks after the last TACE. Two treatment groups were determined using a randomization sheet: In 30 patients, TACE was performed using Lipiodol only (group 1). In 31 cases Lipiodol was combined with DSMs (group 2). Response according to tumor volume, diameter, mRECIST criteria, and the development of necrotic areas were analyzed and compared using the Mann–Whitney-U, Kruskal–Wallis-H-test, and Spearman-Rho. Survival data were analyzed using the Kaplan–Meier estimator. Results: A mean overall tumor volume reduction of 21.45% (± 62.34%) was observed with an average tumor volume reduction of 19.95% in group 1 vs. 22.95% in group 2 (p = 0.653). Mean diameter reduction was measured with 6.26% (± 34.75%), for group 1 with 11.86% vs. 4.06% in group 2 (p = 0.678). Regarding mRECIST criteria, group 1 versus group 2 showed complete response in 0 versus 3 cases, partial response in 2 versus 7 cases, stable disease in 21 versus 17 cases, and progressive disease in 3 versus 1 cases (p = 0.010). Estimated overall survival was in mean 33.4 months (95% CI 25.5–41.4) for cTACE with Lipiosol plus DSM, and 32.5 months (95% CI 26.6–38.4), for cTACE with Lipiodol-only (p = 0.844), respectively. Conclusions: The additional application of DSM during cTACE showed a significant benefit in tumor response according to mRECIST compared to cTACE with Lipiodol-only. No benefit in survival time was observed.
Myocardial fibrosis and inflammation by CMR predict cardiovascular outcome in people living with HIV
(2021)
Objectives_: The goal of this study was to examine prognostic relationships between cardiac imaging measures and cardiovascular outcome in people living with human immunodeficiency virus (HIV) (PLWH) on highly active antiretroviral therapy (HAART).
Background: PLWH have a higher prevalence of cardiovascular disease and heart failure (HF) compared with the noninfected population. The pathophysiological drivers of myocardial dysfunction and worse cardiovascular outcome in HIV remain poorly understood.
Methods: This prospective observational longitudinal study included consecutive PLWH on long-term HAART undergoing cardiac magnetic resonance (CMR) examination for assessment of myocardial volumes and function, T1 and T2 mapping, perfusion, and scar. Time-to-event analysis was performed from the index CMR examination to the first single event per patient. The primary endpoint was an adjudicated adverse cardiovascular event (cardiovascular mortality, nonfatal acute coronary syndrome, an appropriate device discharge, or a documented HF hospitalization).
Results: A total of 156 participants (62% male; age [median, interquartile range]: 50 years [42 to 57 years]) were included. During a median follow-up of 13 months (9 to 19 months), 24 events were observed (4 HF deaths, 1 sudden cardiac death, 2 nonfatal acute myocardial infarction, 1 appropriate device discharge, and 16 HF hospitalizations). Patients with events had higher native T1 (median [interquartile range]: 1,149 ms [1,115 to 1,163 ms] vs. 1,110 ms [1,075 to 1,138 ms]); native T2 (40 ms [38 to 41 ms] vs. 37 ms [36 to 39 ms]); left ventricular (LV) mass index (65 g/m2 [49 to 77 g/m2] vs. 57 g/m2 [49 to 64 g/m2]), and N-terminal pro–B-type natriuretic peptide (109 pg/l [25 to 337 pg/l] vs. 48 pg/l [23 to 82 pg/l]) (all p < 0.05). In multivariable analyses, native T1 was independently predictive of adverse events (chi-square test, 15.9; p < 0.001; native T1 [10 ms] hazard ratio [95% confidence interval]: 1.20 [1.08 to 1.33]; p = 0.001), followed by a model that also included LV mass (chi-square test, 17.1; p < 0.001). Traditional cardiovascular risk scores were not predictive of the adverse events.
Conclusions: Our findings reveal important prognostic associations of diffuse myocardial fibrosis and LV remodeling in PLWH. These results may support development of personalized approaches to screening and early intervention to reduce the burden of HF in PLWH (International T1 Multicenter Outcome Study; NCT03749343).
Objectives: To compare radiation dose and image quality of single-energy (SECT) and dual-energy (DECT) head and neck CT examinations performed with second- and third-generation dual-source CT (DSCT) in matched patient cohorts. Methods: 200 patients (mean age 55.1 ± 16.9 years) who underwent venous phase head and neck CT with a vendor-preset protocol were retrospectively divided into four equal groups (n = 50) matched by gender and BMI: second (Group A, SECT, 100-kV; Group B, DECT, 80/Sn140-kV), and third-generation DSCT (Group C, SECT, 100-kV; Group D, DECT, 90/Sn150-kV). Assess- ment of radiation dose was performed for an average scan length of 27 cm. Contrast-to-noise ratio measure- ments and dose-independent figure-of-merit calcu- lations of the submandibular gland, thyroid, internal jugular vein, and common carotid artery were analyzed quantitatively. Qualitative image parameters were evalu- ated regarding overall image quality, artifacts and reader confidence using 5-point Likert scales. Results: Effective radiation dose (ED) was not signifi- cantly different between SECT and DECT acquisition for each scanner generation (p = 0.10). Significantly lower effective radiation dose (p < 0.01) values were observed for third-generation DSCT groups C (1.1 ± 0.2 mSv) and D (1.0 ± 0.3 mSv) compared to second-generation DSCT groups A (1.8 ± 0.1 mSv) and B (1.6 ± 0.2 mSv). Figure-of- merit/contrast-to-noise ratio analysis revealed superior results for third-generation DECT Group D compared to all other groups. Qualitative image parameters showed non-significant differences between all groups (p > 0.06). Conclusion: Contrast-enhanced head and neck DECT can be performed with second- and third-generation DSCT systems without radiation penalty or impaired image quality compared with SECT, while third-generation DSCT is the most dose efficient acquisition method. Advances in knowledge: Differences in radiation dose between SECT and DECT of the dose-vulnerable head and neck region using DSCT systems have not been evaluated so far. Therefore, this study directly compares radiation dose and image quality of standard SECT and DECT protocols of second- and third-generation DSCT platforms.
Objectives: To determine the diagnostic accuracy of dual-energy CT (DECT) virtual noncalcium (VNCa) reconstructions for assessing thoracic disk herniation compared to standard grayscale CT. Methods: In this retrospective study, 87 patients (1131 intervertebral disks; mean age, 66 years; 47 women) who underwent third-generation dual-source DECT and 3.0-T MRI within 3 weeks between November 2016 and April 2020 were included. Five blinded radiologists analyzed standard DECT and color-coded VNCa images after a time interval of 8 weeks for the presence and degree of thoracic disk herniation and spinal nerve root impingement. Consensus reading of independently evaluated MRI series served as the reference standard, assessed by two separate experienced readers. Additionally, image ratings were carried out by using 5-point Likert scales. Results: MRI revealed a total of 133 herniated thoracic disks. Color-coded VNCa images yielded higher overall sensitivity (624/665 [94%; 95% CI, 0.89–0.96] vs 485/665 [73%; 95% CI, 0.67–0.80]), specificity (4775/4990 [96%; 95% CI, 0.90–0.98] vs 4066/4990 [82%; 95% CI, 0.79–0.84]), and accuracy (5399/5655 [96%; 95% CI, 0.93–0.98] vs 4551/5655 [81%; 95% CI, 0.74–0.86]) for the assessment of thoracic disk herniation compared to standard CT (all p < .001). Interrater agreement was excellent for VNCa and fair for standard CT (ϰ = 0.82 vs 0.37; p < .001). In addition, VNCa imaging achieved higher scores regarding diagnostic confidence, image quality, and noise compared to standard CT (all p < .001). Conclusions: Color-coded VNCa imaging yielded substantially higher diagnostic accuracy and confidence for assessing thoracic disk herniation compared to standard CT.
Objectives: To correlate the radiological assessment of the mastoid facial canal in postoperative cochlear implant (CI) cone-beam CT (CBCT) and other possible contributing clinical or implant-related factors with postoperative facial nerve stimulation (FNS) occurrence. Methods: Two experienced radiologists evaluated retrospectively 215 postoperative post-CI CBCT examinations. The mastoid facial canal diameter, wall thickness, distance between the electrode cable and mastoid facial canal, and facial-chorda tympani angle were assessed. Additionally, the intracochlear position and the insertion angle and depth of electrodes were evaluated. Clinical data were analyzed for postoperative FNS within 1.5-year follow-up, CI type, onset, and causes for hearing loss such as otosclerosis, meningitis, and history of previous ear surgeries. Postoperative FNS was correlated with the measurements and clinical data using logistic regression. Results: Within the study population (mean age: 56 ± 18 years), ten patients presented with FNS. The correlations between FNS and facial canal diameter (p = 0.09), wall thickness (p = 0.27), distance to CI cable (p = 0.44), and angle with chorda tympani (p = 0.75) were statistically non-significant. There were statistical significances for previous history of meningitis/encephalitis (p = 0.001), extracochlear-electrode-contacts (p = 0.002), scala-vestibuli position (p = 0.02), younger patients’ age (p = 0.03), lateral-wall-electrode type (p = 0.04), and early/childhood onset hearing loss (p = 0.04). Histories of meningitis/encephalitis and extracochlear-electrode-contacts were included in the first two steps of the multivariate logistic regression. Conclusion: The mastoid-facial canal radiological assessment and the positional relationship with the CI electrode provide no predictor of postoperative FNS. Histories of meningitis/encephalitis and extracochlear-electrode-contacts are important risk factors.
Background: Glucagon-like peptide-1 receptor agonists may be a treatment option in patients with non-alcoholic fatty liver disease (NAFLD). Aims: To investigate the effects of semaglutide on liver stiffness and liver fat in subjects with NAFLD using non-invasive magnetic resonance imaging (MRI) methods. Methods: This randomised, double-blind, placebo-controlled trial enrolled subjects with liver stiffness 2.50-4.63 kPa by magnetic resonance elastography (MRE) and liver steatosis ≥10% by MRI proton density fat fraction (MRI-PDFF). The primary endpoint was change from baseline to week 48 in liver stiffness assessed by MRE. Results: Sixty-seven subjects were randomised to once-daily subcutaneous semaglutide 0.4 mg (n = 34) or placebo (n = 33). Change from baseline in liver stiffness was not significantly different between semaglutide and placebo at week 48 (estimated treatment ratio 0.96 (95% CI 0.89, 1.03; P = 0.2798); significant differences in liver stiffness were not observed at weeks 24 or 72. Reductions in liver steatosis were significantly greater with semaglutide (estimated treatment ratios: 0.70 [0.59, 0.84], P = 0.0002; 0.47 [0.36, 0.60], P < 0.0001; and 0.50 [0.39, 0.66], P < 0.0001) and more subjects achieved a ≥ 30% reduction in liver fat content with semaglutide at weeks 24, 48 and 72, (all P < 0.001). Decreases in liver enzymes, body weight and HbA1c were also observed with semaglutide. Conclusions: The change in liver stiffness in subjects with NAFLD was not significantly different between semaglutide and placebo. However, semaglutide significantly reduced liver steatosis compared with placebo which, together with improvements in liver enzymes and metabolic parameters, suggests a positive impact on disease activity and metabolic profile. ClinicalTrials.gov identifier: NCT03357380
Objectives: To evaluate the predictive value of volumetric bone mineral density (BMD) assessment of the lumbar spine derived from phantomless dual-energy CT (DECT)-based volumetric material decomposition as an indicator for the 2-year occurrence risk of osteoporosis-associated fractures. Methods: L1 of 92 patients (46 men, 46 women; mean age, 64 years, range, 19–103 years) who had undergone third-generation dual-source DECT between 01/2016 and 12/2018 was retrospectively analyzed. For phantomless BMD assessment, dedicated DECT postprocessing software using material decomposition was applied. Digital files of all patients were sighted for 2 years following DECT to obtain the incidence of osteoporotic fractures. Receiver operating characteristic (ROC) analysis was used to calculate cut-off values and logistic regression models were used to determine associations of BMD, sex, and age with the occurrence of osteoporotic fractures. Results: A DECT-derived BMD cut-off of 93.70 mg/cm3 yielded 85.45% sensitivity and 89.19% specificity for the prediction to sustain one or more osteoporosis-associated fractures within 2 years after BMD measurement. DECT-derived BMD was significantly associated with the occurrence of new fractures (odds ratio of 0.8710, 95% CI, 0.091–0.9375, p < .001), indicating a protective effect of increased DECT-derived BMD values. Overall AUC was 0.9373 (CI, 0.867–0.977, p < .001) for the differentiation of patients who sustained osteoporosis-associated fractures within 2 years of BMD assessment. Conclusions: Retrospective DECT-based volumetric BMD assessment can accurately predict the 2-year risk to sustain an osteoporosis-associated fracture in at-risk patients without requiring a calibration phantom. Lower DECT-based BMD values are strongly associated with an increased risk to sustain fragility fractures.
Key Points: Dual-energy CT–derived assessment of bone mineral density can identify patients at risk to sustain osteoporosis-associated fractures with a sensitivity of 85.45% and a specificity of 89.19%. The DECT-derived BMD threshold for identification of at-risk patients lies above the American College of Radiology (ACR) QCT guidelines for the identification of osteoporosis (93.70 mg/cm 3 vs 80 mg/cm 3 ).
Objectives: To compare dual-energy CT (DECT) and MRI for assessing presence and extent of traumatic bone marrow edema (BME) and fracture line depiction in acute vertebral fractures. Methods: Eighty-eight consecutive patients who underwent dual-source DECT and 3-T MRI of the spine were retrospectively analyzed. Five radiologists assessed all vertebrae for presence and extent of BME and for identification of acute fracture lines on MRI and, after 12 weeks, on DECT series. Additionally, image quality, image noise, and diagnostic confidence for overall diagnosis of acute vertebral fracture were assessed. Quantitative analysis of CT numbers was performed by a sixth radiologist. Two radiologists analyzed MRI and grayscale DECT series to define the reference standard. Results: For assessing BME presence and extent, DECT showed high sensitivity (89% and 84%, respectively) and specificity (98% in both), and similarly high diagnostic confidence compared to MRI (2.30 vs. 2.32; range 0–3) for the detection of BME (p = .72). For evaluating acute fracture lines, MRI achieved high specificity (95%), moderate sensitivity (76%), and a significantly lower diagnostic confidence compared to DECT (2.42 vs. 2.62, range 0–3) (p < .001). A cutoff value of − 0.43 HU provided a sensitivity of 89% and a specificity of 90% for diagnosing BME, with an overall AUC of 0.96. Conclusions: DECT and MRI provide high diagnostic confidence and image quality for assessing acute vertebral fractures. While DECT achieved high overall diagnostic accuracy in the analysis of BME presence and extent, MRI provided moderate sensitivity and lower confidence for evaluating fracture lines.
Objectives: To investigate the diagnostic accuracy of color-coded contrast-enhanced dual-energy CT virtual noncalcium (VNCa) reconstructions for the assessment of lumbar disk herniation compared to unenhanced VNCa imaging.
Methods: A total of 91 patients were retrospectively evaluated (65 years ± 16; 43 women) who had undergone third-generation dual-source dual-energy CT and 3.0-T MRI within an examination interval up to 3 weeks between November 2019 and December 2020. Eight weeks after assessing unenhanced color-coded VNCa reconstructions for the presence and degree of lumbar disk herniation, corresponding contrast-enhanced portal venous phase color-coded VNCa reconstructions were independently analyzed by the same five radiologists. MRI series were additionally analyzed by one highly experienced musculoskeletal radiologist and served as reference standard.
Results: MRI depicted 210 herniated lumbar disks in 91 patients. VNCa reconstructions derived from contrast-enhanced CT scans showed similar high overall sensitivity (93% vs 95%), specificity (94% vs 95%), and accuracy (94% vs 95%) for the assessment of lumbar disk herniation compared to unenhanced VNCa images (all p > .05). Interrater agreement in VNCa imaging was excellent for both, unenhanced and contrast-enhanced CT (κ = 0.84 vs κ = 0.86; p > .05). Moreover, ratings for diagnostic confidence, image quality, and noise differed not significantly between unenhanced and contrast-enhanced VNCa series (all p > .05).
Conclusions: Color-coded VNCa reconstructions derived from contrast-enhanced dual-energy CT yield similar diagnostic accuracy for the depiction of lumbar disk herniation compared to unenhanced VNCa imaging and therefore may improve opportunistic retrospective lumbar disk herniation assessment, particularly in case of staging CT examinations.
Key Points
• Color-coded dual-source dual-energy CT virtual noncalcium (VNCa) reconstructions derived from portal venous phase yield similar high diagnostic accuracy for the assessment of lumbar disk herniation compared to unenhanced VNCa CT series (94% vs 95%) with MRI serving as a standard of reference.
• Diagnostic confidence, image quality, and noise levels differ not significantly between unenhanced and contrast-enhanced portal venous phase VNCa dual-energy CT series.
• Dual-source dual-energy CT might have the potential to improve opportunistic retrospective lumbar disk herniation assessment in CT examinations performed for other indications through reconstruction of VNCa images.
Objective: To determine the early treatment response after microwave ablation (MWA) of inoperable lung neoplasms using the apparent diffusion coefficient (ADC) value calculated 24 h after the ablation.
Materials and methods: This retrospective study included 47 patients with 68 lung lesions, who underwent percutaneous MWA from January 2008 to December 2017. Evaluation of the lesions was done using MRI including DWI sequence with ADC value calculation pre-ablation and 24 h post-ablation. DWI-MR was performed with b values (50, 400, 800 mm2/s). The post-ablation follow-up was performed using chest CT and/or MRI within 24 h following the procedure; after 3, 6, 9, and 12 months; and every 6 months onwards to determine the local tumor response. The post-ablation ADC value changes were compared to the end response of the lesions.
Results: Forty-seven patients (mean age: 63.8 ± 14.2 years, 25 women) with 68 lesions having a mean tumor size of 1.5 ± 0.9 cm (range: 0.7–5 cm) were evaluated. Sixty-one lesions (89.7%) showed a complete treatment response, and the remaining 7 lesions (10.3%) showed a local progression (residual activity). There was a statistically significant difference regarding the ADC value measured 24 h after the ablation between the responding (1.7 ± 0.3 × 10−3 mm2/s) and non-responding groups (1.4 ± 0.3 × 10−3 mm2/s) with significantly higher values in the responding group (p = 0.001). A suggested ADC cut-off value of 1.42 could be used as a reference point for the post-ablation response prediction (sensitivity: 66.67%, specificity: 84.21%, PPV: 66.7%, and NPV: 84.2%). No significant difference was reported regarding the ADC value performed before the ablation as a factor for the prognosis of treatment response (p = 0.86).
Conclusion: ADC value assessment following ablation may allow the early prediction of treatment efficacy after MWA of inoperable lung neoplasms.
Key Points
• ADC value calculated 24 h post-treatment may allow the early prediction of MWA efficacy as a treatment of pulmonary tumors and can be used in the early immediate post-ablation imaging follow-up.
• The pre-treatment ADC value of lung neoplasms is not different between the responding and non-responding tumors.
Purpose: To stratify differences in visual semantic and quantitative imaging features in intensive care patients with nonspecific mastoid effusions versus patients with acute mastoiditis (AM) requiring surgical treatment. Methods: We included 48 patients (male, 28; female, 20; mean age, 59.5 ± 18.1 years) with mastoid opacification (AM, n = 24; control, n = 24) who underwent clinically indicated cerebral CT between 12/2007 and 07/2018 in this retrospective study. Semantic features described the extend and asymmetry of mastoid and middle-ear cavity opacification and complications like erosive changes. Minimum, maximum and mean Hounsfield unit (HU) values were obtained as quantitative features. We analyzed the features employing univariate testing. Results: Compared to intensive care patients, AM patients revealed asymmetric mastoid or middle-ear cavity opacification (likelihood-ratio (LR) < 0.001). Applying a dedicated threshold of the extent of opacification, AM patients reached significance levels of LR = 0.042 and 0.002 for mastoid and middle-ear cavity opacification. AM cases showed higher maximum and mean HU values (p = 0.009, p = 0.024). Conclusions: We revealed that the extent and asymmetry of mastoid and middle-ear cavity opacification differs significantly between AM patients and intensive care patients. Multicenter research is needed to expand our cohort and possibly pave the way to build a non-invasive predictive model for AM in the future.
Background: To assess the potential of radiomic features to quantify components of blood in intraaortic vessels to non-invasively predict moderate-to-severe anemia in non-contrast enhanced CT scans. Methods: One hundred patients (median age, 69 years; range, 19–94 years) who received CT scans of the thoracolumbar spine and blood-testing for hemoglobin and hematocrit levels ± 24 h between 08/2018 and 11/2019 were retrospectively included. Intraaortic blood was segmented using a spherical volume of interest of 1 cm diameter with consecutive radiomic analysis applying PyRadiomics software. Feature selection was performed applying analysis of correlation and collinearity. The final feature set was obtained to differentiate moderate-to-severe anemia. Random forest machine learning was applied and predictive performance was assessed. A decision-tree was obtained to propose a cut-off value of CT Hounsfield units (HU). Results: High correlation with hemoglobin and hematocrit levels was shown for first-order radiomic features (p < 0.001 to p = 0.032). The top 3 features showed high correlation to hemoglobin values (p) and minimal collinearity (r) to the top ranked feature Median (p < 0.001), Energy (p = 0.002, r = 0.387), Minimum (p = 0.032, r = 0.437). Median (p < 0.001) and Minimum (p = 0.003) differed in moderate-to-severe anemia compared to non-anemic state. Median yielded superiority to the combination of Median and Minimum (p(AUC) = 0.015, p(precision) = 0.017, p(accuracy) = 0.612) in the predictive performance employing random forest analysis. A Median HU value ≤ 36.5 indicated moderate-to-severe anemia (accuracy = 0.90, precision = 0.80). Conclusions: First-order radiomic features correlate with hemoglobin levels and may be feasible for the prediction of moderate-to-severe anemia. High dimensional radiomic features did not aid augmenting the data in our exemplary use case of intraluminal blood component assessment.
Diagnostic value of dynamic magnetic resonance imaging of temporomandibular joint dysfunction
(2021)
Background: To estimate the diagnostic value of dynamic magnetic resonance imaging (MRI) for the assessment of the temporomandibular joint (TMJ) compared to standard static MRI sequences in patients with TMJ dysfunction (TMD).
Methods and materials: This retrospective study included 71 patients with clinical diagnose of TMD. We acquired 5 static T1- and T2-weighted sequences in parasagittal and paracoronal views and one dynamic sequence (trueFISP) in parasagittal view for each TMJ. Image analysis included evaluation of morphology and function of intra-articular structures and rating of the dynamic images as more, equally, or less informative compared to static MRI sequences.
Results: Mean age was 35.0 ± 14.7 years and 50/71 (70.4%) were female. 127/142 (89.4%) TMJs were of diagnostic quality. 42/127 (33.1%) TMJs showed no disc displacement (DD), 56 (44.1%) had DD with disc reduction (DDwR), and 29 (22.8%) had DD without disc reduction (DDwoR). In 38/127 (29.9%) TMJs, dynamic images were rated “more informative”, in 84/127 (66.2%) “equally informative”, and in 5/127 (3.9%) “less informative” compared to solely static images. Overall, 27/71 (38.0%) patients benefited from additional dynamic sequences compared to solely static images. Dynamic images were “more informative” in TMJs with DDwR (23/56 [41.1%], p < 0.001) and in TMJs with DDwoR (13/29 [44.8%], p = 0.007), while it had no beneficial value for TMJ without DD. For evaluation of joint effusion, static T2-weighted images were rated better in 102/127 (80.3%) TMJs compared to dynamic images (<0.001).
Conclusion: Dynamic MRI sequences are beneficial for the evaluation of morphology and function of the TMJ compared to static sequences, especially in patients with temporomandibular disc displacement.
Background: Various studies have been made about the most effective and safest type of treatment for vertebral compression fractures (VCFs). Long-term results are needed for qualitative evaluation.
Purpose: The purpose of the study is to evaluate the effectiveness of percutaneous vertebroplasty (PVP) and percutaneous kyphoplasty (PKP) procedures for VCFs.
Materials and Methods: Forty-nine patients who received either PVP or PKP between 2002 and 2015 returned a specially developed questionnaire and were included in a cross-sectional outcome analysis. The questionnaire assessed pain development by use of a visual analog scale (VAS). Imaging data (CT scans) were retrospectively analyzed for identification of cement leakage.
Results: Patients’ VAS scores significantly decreased after treatment (7.0 ± 3.4 => 3.7 ± 3.4), (p < 0.001). The average pain reduction in patients treated with PVP was −3.3 ± 3.8 (p < 0.001) (median −3.5) and −4.0 ± 3.9 (p < 0.001) (median −4.5) in patients treated with PKP. Fifteen Patients (41.7%) receiving PVP and four patients (30.7%) receiving PKP experienced recurrence of pain. Cement leakage occurred in 10 patients (22.73%). Patients with cement leakage showed comparable VAS scores after treatment (6.8 ± 3.5 => 1.4 ± 1.6), (p = 0.008). Thirty-nine patients reported an increase in mobility (79.6%) and 41 patients an improvement in quality of life (83.7%).
Conclusion: Pain reduction by means of PVP or PKP in patients with VCFs was discernible over the period of observation. Percutaneous vertebroplasty and PKP contribute to the desired treatment results. However, the level of low pain may not remain constant.
Our purpose was to analyze the robustness and reproducibility of magnetic resonance imaging (MRI) radiomic features. We constructed a multi-object fruit phantom to perform MRI acquisition as scan-rescan using a 3 Tesla MRI scanner. We applied T2-weighted (T2w) half-Fourier acquisition single-shot turbo spin-echo (HASTE), T2w turbo spin-echo (TSE), T2w fluid-attenuated inversion recovery (FLAIR), T2 map and T1-weighted (T1w) TSE. Images were resampled to isotropic voxels. Fruits were segmented. The workflow was repeated by a second reader and the first reader after a pause of one month. We applied PyRadiomics to extract 107 radiomic features per fruit and sequence from seven feature classes. We calculated concordance correlation coefficients (CCC) and dynamic range (DR) to obtain measurements of feature robustness. Intraclass correlation coefficient (ICC) was calculated to assess intra- and inter-observer reproducibility. We calculated Gini scores to test the pairwise discriminative power specific for the features and MRI sequences. We depict Bland Altmann plots of features with top discriminative power (Mann–Whitney U test). Shape features were the most robust feature class. T2 map was the most robust imaging technique (robust features (rf), n = 84). HASTE sequence led to the least amount of rf (n = 20). Intra-observer ICC was excellent (≥ 0.75) for nearly all features (max–min; 99.1–97.2%). Deterioration of ICC values was seen in the inter-observer analyses (max–min; 88.7–81.1%). Complete robustness across all sequences was found for 8 features. Shape features and T2 map yielded the highest pairwise discriminative performance. Radiomics validity depends on the MRI sequence and feature class. T2 map seems to be the most promising imaging technique with the highest feature robustness, high intra-/inter-observer reproducibility and most promising discriminative power.
Purpose: To investigate the diagnostic performance of noise-optimized virtual monoenergetic images (VMI+) in dual-energy CT (DECT) of portal vein thrombosis (PVT) compared to standard reconstructions. Method: This retrospective, single-center study included 107 patients (68 men; mean age, 60.1 ± 10.7 years) with malignant or cirrhotic liver disease and suspected PVT who had undergone contrast-enhanced portal-phase DECT of the abdomen. Linearly blended (M_0.6) and virtual monoenergetic images were calculated using both standard VMI and noise-optimized VMI+ algorithms in 20 keV increments from 40 to 100 keV. Quantitative measurements were performed in the portal vein for objective contrast-to-noise ratio (CNR) calculation. The image series showing the greatest CNR were further assessed for subjective image quality and diagnostic accuracy of PVT detection by two blinded radiologists. Results: PVT was present in 38 subjects. VMI+ reconstructions at 40 keV revealed the best objective image quality (CNR, 9.6 ± 4.3) compared to all other image reconstructions (p < 0.01). In the standard VMI series, CNR peaked at 60 keV (CNR, 4.7 ± 2.1). Qualitative image parameters showed the highest image quality rating scores for the 60 keV VMI+ series (median, 4) (p ≤ 0.03). The greatest diagnostic accuracy for the diagnosis of PVT was found for the 40 keV VMI+ series (sensitivity, 96%; specificity, 96%) compared to M_0.6 images (sensitivity, 87%; specificity, 92%), 60 keV VMI (sensitivity, 87%; specificity, 97%), and 60 keV VMI+ reconstructions (sensitivity, 92%; specificity, 97%) (p ≤ 0.01). Conclusions: Low-keV VMI+ reconstructions resulted in significantly improved diagnostic performance for the detection of PVT compared to other DECT reconstruction algorithms.
Purpose: The aim of this study was to prospectively compare the therapy response and safety of microwave (MWA) and radiofrequency ablation (RFA) for the treatment of liver metastases using a dual ablation system.
Methods: Fifty patients with liver metastases (23 men, mean age: 62.8 ± 11.8 years) were randomly assigned to MWA or RFA for thermal ablation using a one generator dual ablation system. Magnetic resonance imaging (MRI) was acquired before treatment and 24 h post ablation. The morphologic responses to treatment regarding size, volume, necrotic areas, and diffusion characteristics were evaluated by MRI. Imaging follow-up was obtained for one year in three months intervals, whereas clinical follow-up was obtained for two years in all patients.
Results: Twenty-six patients received MWA and 24 patients received RFA (mean diameter: 1.6 cm, MWA: 1.7 cm, RFA: 1.5 cm). The mean volume 24 h after ablation was 37.0 cm3 (MWA: 50.5 cm3, RFA: 22.9 cm3, P < 0.01). The local recurrence rate was 0% (0/26) in the MWA-group and 8.3% (2/24) in the RFA-group (P = 0.09). The rate of newly developed malignant formations was 38.0% (19/50) for both groups (MWA: 38.4%, RFA: 37.5%, P = 0.07). The overall survival rate was 70.0% (35/50) after two years (MWA: 76.9%, RFA: 62.5%, P = 0.60). No major complications were reported.
Conclusion: In conclusion, MWA and RFA are both safe and effective methods for the treatment of liver metastases with MWA generating greater volumes of ablation. No significant differences were found for overall survival, rate of neoplasm, or major complications between both groups.
Colorectal cancer (CRC) is one of the most common tumor entities worldwide and a common cause of cancer-associated death. Colorectal cancer liver metastases (CRLM) thereby constitute a severe life-limiting factor. The therapy of CRLM presents a major challenge and surgical resection as well as systemic chemotherapy remain the first-line treatment options. Over the years several locoregional, vascular- and image-based treatments offered by interventional radiologists have emerged when conventional therapies fail, or metastases recurrence occurs. Among such options is the conventional/traditional transarterial chemoembolization (cTACE) by local injection of a combination of chemotherapeutic- and embolic-agents. A similar treatment is the more recent irinotecan-loaded drug-eluting beads TACE (DEBIRI-TACE), which are administered using the same approach. Numerous studies have shown that these different types of chemoembolization can be applied in different clinical settings safely. Furthermore, such treatments can also be combined with other local or systemic therapies. Unfortunately, due to the incoherent patient populations of studies investigating TACE in CRLM, critics state that the definite evidence supporting positive patient outcomes is still lacking. In the following article we review studies on conventional and DEBIRI-TACE. Although highly dependent on the clinical setting, prior therapies and generally the study population, cTACE and DEBIRI-TACE show comparable results. We present the most representative studies on the different chemoembolization procedures and compare the results. Although there is compelling evidence for both approaches, further studies are necessary to determine which patients profit most from these therapies. In conclusion, we determine TACE to be a viable option in CRLM in different clinical settings. Nevertheless, a multidisciplinary approach is desired to offer patients the best possible care.
Case report of rare congenital cardiovascular anomalies associated with truncus arteriosus type 2
(2022)
Truncus arteriosus (TA) is a very rare congenital anomaly with complex cardiovascular anatomy and high lethality also due to severe associated anatomical variants and pathologies. As TA has a massive impact on the survival of a newborn and usually has to be surgically treated. Thus, it is of high importance to understand this congenital cardiovascular disease and associated complications, to improve life expectancy and outcome of these patients. We recently came across a newborn female patient with a rare complex case of persistent TA type 2 associated with further complex cardiovascular anomalies, who received a contrast enhanced CT scan on the 3 rd day post-partum, showing complex cardiovascular abnormalities that were ultimately incompatible with life.