Refine
Year of publication
Document Type
- Article (36)
- Conference Proceeding (3)
- Part of a Book (1)
- Contribution to a Periodical (1)
- Doctoral Thesis (1)
- Preprint (1)
- Working Paper (1)
Has Fulltext
- yes (44)
Is part of the Bibliography
- no (44)
Keywords
- Access (1)
- Autorensysteme (1)
- COVID-19 (1)
- Europe (1)
- Intensive care (1)
- Medienproduktion (1)
- TGF-beta (1)
- Technologie Enhanced Learning (1)
- Web-based Training (1)
- cholestasis (1)
Institute
- Physik (31)
- Medizin (5)
- Psychologie (2)
- Biochemie und Chemie (1)
- Center for Financial Studies (CFS) (1)
- Georg-Speyer-Haus (1)
- House of Finance (HoF) (1)
- Informatik (1)
- Präsidium (1)
- Sustainable Architecture for Finance in Europe (SAFE) (1)
Die Arbeitsgruppe Generative KI erforscht die Folgen von KI für die Goethe-Universität. Die beiden studiumdigitale-Mitarbeiter*innen der AG Julia Schmitt und Dr. David Weiß, der zugleich auch der Leiter der AG ist, geben Auskunft darüber, warum TechnologieAusrollen allein nicht reicht und es wichtig ist, im KI-Hype nicht die Ruhe zu verlieren.
The radiative capture cross section of 238U is very important for the developing of new reactor technologies and the safety of existing ones. Here the preliminary results of the 238U(n,γ) cross section measurement performed at n_TOF with C6D6 scintillation detectors are presented, paying particular attention to data reduction and background subtraction.
The Cosmological Lithium Problem refers to the large discrepancy between the abundance of primordial 7Li predicted by the standard theory of Big Bang Nucleosynthesis and the value inferred from the so-called “Spite plateau” in halo stars. A possible explanation for this longstanding puzzle in Nuclear Astrophysics is related to the incorrect estimation of the destruction rate of 7Be, which is responsible for the production of 95% of primordial Lithium. While charged-particle induced reactions have mostly been ruled out, data on the 7Be(n,α) and 7Be(n,p) reactions are scarce or completely missing, so that a large uncertainty still affects the abundance of 7Li predicted by the standard theory of Big Bang Nucleosynthesis. Both reactions have been measured at the n_TOF facility at CERN, providing for the first time data in a wide neutron energy range.
The membrane proximal external region (MPER) of the HIV-1 glycoprotein gp41 is targeted by the broadly neutralizing antibodies 2F5 and 4E10. To date, no immunization regimen in animals or humans has produced HIV-1 neutralizing MPER-specific antibodies. We immunized llamas with gp41-MPER proteoliposomes and selected a MPER-specific single chain antibody (VHH), 2H10, whose epitope overlaps with that of mAb 2F5. Bi-2H10, a bivalent form of 2H10, which displayed an approximately 20-fold increased affinity compared to the monovalent 2H10, neutralized various sensitive and resistant HIV-1 strains, as well as SHIV strains in TZM-bl cells. X-ray and NMR analyses combined with mutagenesis and modeling revealed that 2H10 recognizes its gp41 epitope in a helical conformation. Notably, tryptophan 100 at the tip of the long CDR3 is not required for gp41 interaction but essential for neutralization. Thus bi-2H10 is an anti-MPER antibody generated by immunization that requires hydrophobic CDR3 determinants in addition to epitope recognition for neutralization similar to the mode of neutralization employed by mAbs 2F5 and 4E10.
Purpose: The coronavirus disease 2019 (COVID-19) poses major challenges to health-care systems worldwide. This pandemic demonstrates the importance of timely access to intensive care and, therefore, this study aims to explore the accessibility of intensive care beds in 14 European countries and its impact on the COVID-19 case fatality ratio (CFR).
Methods: We examined access to intensive care beds by deriving (1) a regional ratio of intensive care beds to 100,000 population capita (accessibility index, AI) and (2) the distance to the closest intensive care unit. The cross-sectional analysis was performed at a 5-by-5 km spatial resolution and results were summarized nationally for 14 European countries. The relationship between AI and CFR was analyzed at the regional level.
Results: We found national-level differences in the levels of access to intensive care beds. The AI was highest in Germany (AI = 35.3), followed by Estonia (AI = 33.5) and Austria (AI = 26.4), and lowest in Sweden (AI = 5) and Denmark (AI = 6.4). The average travel distance to the closest hospital was highest in Croatia (25.3 min by car) and lowest in Luxembourg (9.1 min). Subnational results illustrate that capacity was associated with population density and national-level inventories. The correlation analysis revealed a negative correlation of ICU accessibility and COVID-19 CFR (r = − 0.57; p < 0.001).
Conclusion: Geographical access to intensive care beds varies significantly across European countries and low ICU accessibility was associated with a higher proportion of COVID-19 deaths to cases (CFR). Important differences in access are due to the sizes of national resource inventories and the distribution of health-care facilities relative to the human population. Our findings provide a resource for officials planning public health responses beyond the current COVID-19 pandemic, such as identifying potential locations suitable for temporary facilities or establishing logistical plans for moving severely ill patients to facilities with available beds.
Accurate measurement of the standard 235U(n,f) cross section from thermal to 170 keV neutron energy
(2020)
An accurate measurement of the 235U(n,f) cross section from thermal to 170 keV of neutron energy has recently been performed at n_TOF facility at CERN using 6Li(n,t)4He and 10B(n,α)7Li as references. This measurement has been carried out in order to investigate a possible overestimation of the 235U fission cross section evaluation provided by most recent libraries between 10 and 30 keV. A custom experimental apparatus based on in-beam silicon detectors has been used, and a Monte Carlo simulation in GEANT4 has been employed to characterize the setup and calculate detectors efficiency. The results evidenced the presence of an overestimation in the interval between 9 and 18 keV and the new data may be used to decrease the uncertainty of 235U(n,f) cross section in the keV region.
Above 1 MeV of incident neutron energy the fission fragment angular distribution (FFAD) has generally a strong anisotropic behavior due to the combination of the incident orbital momentum and the intrinsic spin of the fissioning nucleus. This effect has to be taken into account for the efficiency estimation of devices used for fission cross section measurements. In addition it bears information on the spin deposition mechanism and on the structure of transitional states. We designed and constructed a detection device, based on Parallel Plate Avalanche Counters (PPAC), for measuring the fission fragment angular distributions of several isotopes, in particular 232Th. The measurement has been performed at n_TOF at CERN taking advantage of the very broad energy spectrum of the neutron beam. Fission events were recognized by back to back detection in coincidence in two position-sensitive detectors surrounding the targets. The detection efficiency, depending mostly on the stopping of fission fragments in backings and electrodes, has been computed with a Geant4 simulation and validated by the comparison to the measured case of 235U below 3 keV where the emission is isotropic. In the case of 232Th, the result is in good agreement with previous data below 10 MeV, with a good reproduction of the structures associated to vibrational states and the opening of second chance fission. In the 14 MeV region our data are much more accurate than previous ones which are broadly scattered.
Die Volkshochschulen sind der größte Bildungsanbieter in Deutschland. 2013 startete eine VHS-Initiative den vhsMOOC: eine offene Online-Veranstaltung zum Thema selbstbestimmtes Weblernen. Auf mehreren Plattformen wie Google+, Facebook und Twitter wurde gleichzeitig gepostet und kommentiert, auf YouTube entstanden 48 Videos zum vhsMOOC, in denen sich VHS-Mitarbeiterinnen und Mitarbeiter über Weblernen, neue Lehr- und Lernformate, unterstützende Tools und die Entwicklung der Volkshochschulen äußern. Der Band fasst den Verlauf, die Argumente und die Ergebnisse der achtwöchigen Online-Lehrveranstaltung zusammen. Passend zum offenen Format des vhsMOOC sind die Inhalte des Bandes auch auf wbv Open Access verfügbar.
The experimental area 2 (EAR-2) at CERNs neutron time-of-flight facility (n_TOF), which is operational since 2014, is designed and built as a short-distance complement to the experimental area 1 (EAR-1). The Parallel Plate Avalanche Counter (PPAC) monitor experiment was performed to characterize the beam pro↓le and the shape of the neutron 'ux at EAR-2. The prompt γ-flash which is used for calibrating the time-of-flight at EAR-1 is not seen by PPAC at EAR-2, shedding light on the physical origin of this γ-flash.