Refine
Year of publication
Has Fulltext
- yes (24)
Is part of the Bibliography
- no (24)
Keywords
Institute
Proteins encoded by small open reading frames (sORFs) have a widespread occurrence in diverse microorganisms and can be of high functional importance. However, due to annotation biases and their technically challenging direct detection, these small proteins have been overlooked for a long time and were only recently rediscovered. The currently rapidly growing number of such proteins requires efficient methods to investigate their structure–function relationship. Herein, a method is presented for fast determination of the conformational properties of small proteins. Their small size makes them perfectly amenable for solution-state NMR spectroscopy. NMR spectroscopy can provide detailed information about their conformational states (folded, partially folded, and unstructured). In the context of the priority program on small proteins funded by the German research foundation (SPP2002), 27 small proteins from 9 different bacterial and archaeal organisms have been investigated. It is found that most of these small proteins are unstructured or partially folded. Bioinformatics tools predict that some of these unstructured proteins can potentially fold upon complex formation. A protocol for fast NMR spectroscopy structure elucidation is described for the small proteins that adopt a persistently folded structure by implementation of new NMR technologies, including automated resonance assignment and nonuniform sampling in combination with targeted acquisition.
Aim of the study: Investigation, whether water-filtered infrared-A (wIRA) irradiation during moderate bicycle ergometer endurance exercise has effects especially on local fat reduction and on weight reduction beyond the effects of ergometer exercise alone.
Methods: Randomised controlled study with 40 obese females (BMI 30-40 (median: 34.5), body weight 76-125 (median: 94.9) kg, age 20-40 (median: 35.5) years, isocaloric nutrition), 20 in the wIRA group and 20 in the control group. In both groups each participant performed 3 times per week over 4 weeks for 45 minutes bicycle ergometer endurance exercise with a constant load according to a lactate level of 2 mmol/l (aerobic endurance load, as determined before the intervention period). In the wIRA group in addition large parts of the body (including waist, hip, and thighs) were irradiated during all ergometries of the intervention period with visible light and a predominant part of water-filtered infrared-A (wIRA), using the irradiation unit “Hydrosun® 6000” with 10 wIRA radiators (Hydrosun® Medizintechnik, Müllheim, Germany, radiator type 500, 4 mm water cuvette, yellow filter, water-filtered spectrum 500-1400 nm) around a speed independent bicycle ergometer.
Main variable of interest: change of “the sum of circumferences of waist, hip, and both thighs of each patient” over the intervention period (4 weeks). Additional variables of interest: body weight, body mass index BMI, body fat percentage, fat mass, fat-free mass, water mass (analysis of body composition by tetrapolar bioimpedance analysis), assessment of an arteriosclerotic risk profile by blood investigation of variables of lipid metabolism (cholesterol, triglycerides, high density lipoproteins HDL, low density lipoproteins LDL, apolipoprotein A1, apolipoprotein B), clinical chemistry (fasting glucose, alanin-aminotransferase ALT (= glutamyl pyruvic transaminase GPT), gamma-glutamyl-transferase GGT, creatinine, albumin), endocrinology (leptin, adiponectin (= adipo Q), homocysteine, insulin). All variables were at least measured before and after the intervention period. Ergometry (ECG, blood pressure behaviour, lactate curve with power at 2, 3 and 4 mmol/l) before the intervention period. In addition: nutrition training ahead of and during the intervention period with a nutrition protocol over one week for assessment of the daily energy intake; calculation of basic metabolic rate and total energy requirement. Assessment of undesired effects.
Only methods of non-parametric statistics were used, both descriptive (median, percentiles of 25 and 75 (= interquartile range), minimum, maximum) and confirmatory (two-sided Mann-Whitney U test for unpaired samples for the only one main variable of interest). Total error probability: .05 (5%). An intention to treat analysis ITT with last observed carry forward method was used preferably (presented results) and in addition an on treatment analysis OT. Only 2 (treatment group) and 4 (control group) drop-outs occurred (mostly due to lack of time).
Results: The “sum of circumferences of waist, hip, and both thighs of each patient” decreased during the 4 weeks significantly more (p<.001) in the wIRA group than in the control group: medians and interquartile ranges: -8.0 cm (-10.5 cm/-4.1 cm) vs. -1.8 cm (-4.4 cm/0.0 cm).
As well “body weight of each patient” decreased during the 4 weeks markedly more in the wIRA group than in the control group: medians and interquartile ranges: -1.9 kg (-4.0 kg/0.0 kg) vs. 0.0 kg (-1.5 kg/+0.4 kg); median of body weight changed from 99.3 kg to 95.6 kg (wIRA) vs. 89.9 kg to 89.6 kg (control). A similar effect showed the body mass index BMI.
Blood variables of interest remained unchanged or showed some slight improvements during the treatment period, concerning most variables with no obvious differences between the two groups; insulin showed a slight trend to decrease in the wIRA group and to increase in the control group.
Undesired effects of the treatment were not seen.
Discussion: The results of the study suggest, that wIRA – during moderate bicycle ergometer endurance exercise as lipolytic stimulus – increases local lipolysis with a local fat reduction (thighs) in the otherwise bradytrophic fatty tissue. The presumably underlying mechanisms of wIRA have already been proven: wIRA acts both by thermal effects and by non-thermal effects. Thermal effects of wIRA are the generation of a therapeutic field of warmth with the increase of tissue temperature, tissue oxygen partial pressure, and tissue blood flow, and by this regional metabolism. As fatty tissue normally has a slow metabolism (bradytrophic and hypothermic tissue) with a low rate of lipolysis, wIRA can increase lipolysis in fatty tissue and the mobilized fats are burned in musculature during the ergometer exercise.
Conclusion: The results of the study indicate, that wIRA irradiation during moderate ergometer endurance exercise can be used – in combination with an appropriate nutrition – to improve body composition, especially local fat distribution, and the reduction of fat and body weight in obese persons.
Keywords: water-filtered infrared-A (wIRA), weight reduction, local fat reduction, bicycle ergometer endurance exercise, lipolysis, randomised controlled study, intervention trial, body weight, body mass index BMI, analysis of body composition, tetrapolar bioimpedance analysis, lactate, lipid metabolism, cholesterol, triglycerides, high density lipoproteins HDL, low density lipoproteins LDL
Two-particle correlation functions of negative hadrons over wide phase space, and transverse mass spectra of negative hadrons and deuterons near mid-rapidity have been measured in central Pb+Pb collisions at 158 GeV per nucleon by the NA49 experiment at the CERN SPS. A novel Coulomb correction procedure for the negative two-particle correlations is employed making use of the measured oppositely charged particle correlation. Within an expanding source scenario these results are used to extract the dynamic characteristics of the hadronic source, resolving the ambiguities between the temperature and transverse expansion velocity of the source, that are unavoidable when single and two particle spectra are analysed separately. The source shape, the total duration of the source expansion, the duration of particle emission, the freeze-out temperature and the longitudinal and transverse expansion velocities are deduced.
We report measurements of Xi and Xi-bar hyperon absolute yields as a function of rapidity in 158 GeV/c Pb+Pb collisions. At midrapidity, dN/dy = 2.29 +/- 0.12 for Xi, and 0.52 +/- 0.05 for Xi-bar, leading to the ratio of Xi-bar/Xi = 0.23 +/- 0.03. Inverse slope parameters fitted to the measured transverse mass spectra are of the order of 300 MeV near mid-rapidity. The estimated total yield of Xi particles in Pb+Pb central interactions amounts to 7.4 +/- 1.0 per collision. Comparison to Xi production in properly scaled p+p reactions at the same energy reveals a dramatic enhancement (about one order of magnitude) of Xi production in Pb+Pb central collisions over elementary hadron interactions.
The directed and elliptic flow of protons and charged pions has been observed from the semi-central collisions of a 158 GeV/nucleon Pb beam with a Pb target. The rapidity and transverse momentum dependence of the flow has been measured. The directed flow of the pions is opposite to that of the protons but both exhibit negative flow at low pt. The elliptic flow of both is fairly independent of rapidity but rises with pt. PACS numbers: 25.75.-q, 25.75.Ld
Using the NA49 main TPC, the central production of hyperons has been measured in CERN SPS Pb - Pb collisions at 158 GeV c-1. The preliminary ratio, studied at 2.0 < y < 2.6 and 1 < pT < 3 GeV c-1, equals ~ (13 ± 4)% (systematic error only). It is compatible, within errors, with the previously obtained ratios for central S + S [1], S + W [2], and S + Au [3] collisions. The fit to the transverse momentum distribution resulted in an inverse slope parameter T of 297 MeV. At this level of statistics we do not see any noticeable enhancement of hyperon production with the increased volume (and, possibly, degree of equilibration) of the system from S + S to Pb + Pb. This result is unexpected and counterintuitive, and should be further investigated. If confirmed, it will have a significant impact on our understanding of mechanisms leading to the enhanced strangeness production in heavy-ion collisions.
Preliminary data on phi production in central Pb + Pb collisions at 158 GeV per nucleon are presented, measured by the NA49 experiment in the hadronic decay channel phi - K+K-. At mid-rapidity, the kaons were separated from pions and protons by combining dE/dx and time-of-flight information; in the forward rapidity range only dE/dx identification was used to obtain the rapidity distribution and a rapidity-integrated mt-spectrum. The mid-rapidity yield obtained was dN/dy = 1.85 ± 0.3 per event; the total phi multiplicity was estimated to be 5.0 ± 0.7 per event. Comparison with published pp data shows a slight, but not very significant strangeness enhancement.