Universitätspublikationen
Refine
Year of publication
- 2011 (111) (remove)
Document Type
- Conference Proceeding (42)
- Doctoral Thesis (25)
- Article (21)
- Bachelor Thesis (9)
- Master's Thesis (6)
- Diploma Thesis (3)
- Book (2)
- Part of Periodical (2)
- diplomthesis (1)
Has Fulltext
- yes (111)
Is part of the Bibliography
- no (111)
Keywords
- Monte-Carlo-Simulation (2)
- (n (1)
- Beryllium-7 (1)
- Chaostheorie (1)
- Dipol-Dipol-Wechselwirkung (1)
- Dissertation (1)
- Dünnschichttransistor (1)
- FRANZ (1)
- Feldeffekt (1)
- Feldeffekttransistor (1)
Institute
- Physik (111) (remove)
The Frankfurt Neutron Source at the Stern-Gerlach-Zentrum is driven by a 2 MeV proton linac consisting of a 4-rod-radio-frequency-quadrupol (RFQ) and an 8 gap IH-DTL structure. RFQ and IH cavity will be powered by only one radio frequency (RF) amplifier to reduce costs. The RF-amplifier of the RFQ-IH combination is coupled into the RFQ. Internal inductive coupling along the axis connects the RFQ with the IH cavity ensuring the required power transition as well as a fixed phase relation between the two structures. The main acceleration of 120 keV up to 2.03 MeV will be reached by the RFQ-IH combination with 175 MHz and at a total length of 2.3 m. The losses in the RFQ-IH combination are about 200 kW.
A CW RFQ prototype
(2011)
A short RFQ prototype was built for RF-tests of high power RFQ structures. We will study thermal effects and determine critical points of the design. HF-simulations with CST Microwave Studio and measurements were done. The cw-tests with 20 kW/m RF-power and simulations of thermal effects with ALGOR were finished successfully. The optimization of some details of the HF design is on focus now. First results and the status of the project will be presented.
The miniaturization of electronics is reaching its limits. Structures necessary to build integrated circuits from semiconductors are shrinking and could reach the size of only a few atoms within the next few years. It will be at the latest at this point in time that the physics of nanostructures gains importance in our every day life. This thesis deals with the physics of quantum impurity models. All models of this class exhibit an identical structure: the simple and small impurity only has few degrees of freedom. It can be built out of a small number of atoms or a single molecule, for example. In the simplest case it can be described by a single spin degree of freedom, in many quantum impurity models, it can be treated exactly. The complexity of the description arises from its coupling to a large number of fermionic or bosonic degrees of freedom (large meaning that we have to deal with particle numbers of the order of 10^{23}). An exact treatment thus remains impossible. At the same time, physical effects which arise in quantum impurity systems often cannot be described within a perturbative theory, since multiple energy scales may play an important role. One example for such an effect is the Kondo effect, where the free magnetic moment of the impurity is screened by a "cloud" of fermionic particles of the quantum bath.
The Kondo effect is only one example for the rich physics stemming from correlation effects in many body systems. Quantum impurity models, and the oftentimes related Kondo effect, have regained the attention of experimental and theoretical physicists since the advent of quantum dots, which are sometimes also referred to as as artificial atoms. Quantum dots offer a unprecedented control and tunability of many system parameters. Hence, they constitute a nice "playground" for fundamental research, while being promising candidates for building blocks of future technological devices as well.
Recently Loss' and DiVincenzo's p roposal of a quantum computing scheme based on spins in quantum dots, increased the efforts of experimentalists to coherently manipulate and read out the spins of quantum dots one by one. In this context two topics are of paramount importance for future quantum information processing: since decoherence times have to be large enough to allow for good error correction schemes, understanding the loss of phase coherence in quantum impurity systems is a prerequisite for quantum computation in these systems. Nonequilibrium phenomena in quantum impurity systems also have to be understood, before one may gain control of manipulating quantum bits.
As a first step towards more complicated nonequilibrium situations, the reaction of a system to a quantum quench, i.e. a sudden change of external fields or other parameters of the system can be investigated. We give an introduction to a powerful numerical method used in this field of research, the numerical renormalization group method, and apply this method and its recent enhancements to various quantum impurity systems.
The main part of this thesis may be structured in the following way:
- Ferromagnetic Kondo Model,
- Spin-Dynamics in the Anisotropic Kondo and the Spin-Boson Model,
- Two Ising-coupled Spins in a Bosonic Bath,
- Decoherence in an Aharanov-Bohm Interferometer.
A modern linear accelerator of ions is a long chain of different accelerating-focusing structures. The design of new linacs, as well as an upgrade and optimization of operating facilities, requires precise and reliable beam matching with the subsequent sections. Proper matching of the beam to the channel allows to improve the performance of the whole linac and to reduce the specific costs. Additionally it helps to avoide particle loss in high energy high intensity linacs. Generally a matching algorithm combines precisely measured or calculated accelerating-focusing external fields and experimentally obtained details of the beam parameters with an advanced code for beam dynamics simulations including space charge effects. Experimental results are introduced into a code as input data. The described algorithm has already been successfully implemented for several GSI projects: an upgrade of the GSI heavy ion linac UNILAC, an ion linac for the cancer therapy, the proton linac for the FAIR facility, a facility for laser acceleration of ions and others. Measured data and results of beam dynamics simulations leading to an achieved improvement of the linac performance are presented.
Ziel der durchgeführten Experimente war es, die Zerfallsmechanismen Van-der-Waals gebundener Argon- und Neon Di- und Trimere in intensiven Laserfeldern zu untersuchen, um mehr über den Einfluss der schwachen Van-der-Waals Bindung auf die Dynamik des Ionisationsprozesses zu erfahren. Da Dimere aufgrund ihrer elektronischen Struktur sehr stark zwei separaten benachbarten Atomen gleichen, vereinen sie atomare und molekulare Eigenschaften in sich und ihre Untersuchung verspricht ein tieferes Verständnis der Wechselwirkungsmechanismen in starken Laserfeldern. Die Verwendung der Impulsspektroskopie Methode COLTRIMS ermöglichte die koinzidente Messung aller beim Aufbruch entstandener ionischer Fragmente sowie eines elektronischen Impulsvektors. Für die beidseitige Einfachionisation des Argon Dimers, konnten bei der gewählten Intensität (etwa 3.3E14W/cm2) drei unterschiedliche Ionisationsprozesse identifiziert werden, von denen zwei zu einer überraschend hohen kinetischen Gesamtenergie der Ionen führen. Aufgrund der Messung der Winkelverteilung der ionischen Fragmente und eines der emittierten Elektronen für lineare und zirkulare Polarisation gelang es, die den drei Prozessen zugrunde liegende Dynamik im Laserfeld zu entschlüsseln. Der dominierende Zerfallskanal stellt demzufolge eine schnelle sequentielle Doppelionisation des Argon Dimers dar, die noch am Gleichgewichtsabstand des Dimers stattfindet. Für den zweithäufigsten Ionisationsprozess ergaben sich zwei mögliche Erklärungsansätze: Entweder wird das Dimer zunächst einseitig doppelionisiert, so dass es auf einer attraktiven Potentialkurve zusammenläuft, bevor es zu einem späteren Zeitpunkt – wenn das Laserfeld bereits abgeklungen ist – durch eine Umverteilung seiner Ladungen in einer Coulomb Explosion fragmentiert, oder das Dimer wird bei einer beidseitigen Tunnelionisation zugleich angeregt, so dass die Coulomb Explosion von einer Potentialkurve erfolgt, die wesentlich steiler als 1/R verläuft. Der schwächste Zerfallskanal, der sich durch die höchste Gesamtenergie auszeichnet, ist auf eine "Frustrated Triple Tunnel Ionization" zurückzuführen, bei der ein hoch angeregter Rydberg Zustand erzeugt wird. Bei der Untersuchung des Neon Dimers konnte bei der gewählten Intensität (etwa 6.3E14W/cm2) nur die sequentielle beidseitige Einfachionisation identifiziert werden, obwohl die Daten Hinweise auf einen weitern Ionisationsprozess mit sehr geringer Statistik aufweisen. Zudem wurde in dieser Arbeit nach der Methode des Coulomb-Explosion-Imaging aus den in Koinzidenz gemessenen Impulsvektoren aller einfachgeladenen ionischen Fragmente eines Aufbruchs die geometrische Struktur der Cluster im Orts-und Impulsraum rekonstruiert. Die ermittelte Grundzustandswellenfunktion des Argon und Neon Dimers zeigt eine gute Übereinstimmung mit quantenmechanischen Berechnungen. Für das Argon und Neon Trimer konnten aus den gemessenen Impulsvektoren mittels einer numerischen Simulation die Bindungswinkel im Ortsraum bestimmt werden, so dass erstmals gezeigt werden konnte, dass diese Trimere gleichseitige Dreieckskonfigurationen aufweisen. Vergleiche mit theoretischen Berechnungen zeigen für die breite Winkelverteilung des Neon Trimers eine hervorragende Übereinstimmung, während die gemessene Winkelverteilung des Argon Trimers etwas breiter als die berechnete ist.
Neutroneneinfangquerschnitte werden häufig mithilfe der Aktivierungsmethode bestimmt. Hierbei wird die zu untersuchende Probe mit Neutronen der gew¨unschten Energie bestrahlt und danach in einem untergrundoptimierten Labor ausgezählt. Am Institut für Angewandte Physik der Goethe Universität Frankfurt wurde ein solcher Aufbau realisiert. Er besteht aus zwei Clover Detektoren, die gegenüberliegend in enger Geometrie angeordnet sind. Die aktivierte Probe wird mittels spezieller Probenhalter reproduzierbar und zentriert zwischen den Detektoren platziert. Die Clover Detektoren sind mit passiven Schilden (Pb) und einer aktiven Abschirmung (BGO) umgeben. Die unterschiedlichen Abschirmungen wirken sich in verschieden Energiebereichen jeweils anders aus.
Diese Arbeit befasst sich mit der astrophysikalischen Motivation und dem Aufbau, mit dem später die Ausbeute einer neutronenaktivierten Probe bestimmt werden kann. Außerdem werden die Ergebnisse der verschiedenen Untergrundmessungen miteinander verglichen.
Beam test of the direct plasma injection scheme (DPIS) is carried out successfully for the first time in China, by setting up a comprehensive test and research platform of RFQ and laser ion source. The C6+ beam is accelerated successfully, and the peak beam current reaches more than 6mA which is measured by a Faraday cup of unique structure. The RF power coupled into the RFQ cavity is also examined, and results reveal that it is the RF power of about 195kW that can produce the peak beam current.
The ARMADILLO bunch compressor currently being designed at IAP is capable of reaching a longitudinal pulse compression ratio of 45 for proton beams of 150 mA at 2 MeV. It will provide one nanosecond proton pulses with a peak current of 7.7 A. The system guides nine linacμbunches deflected by a 5 MHz rf kicker and uses four dipole magnets - two homogeneous and two with field gradients - to merge them on the target. For longitudinal focusing and an energy variation of ±200 keV two multitrack rf cavities are included. ARMADILLO will be installed at the end of the Frankfurt Neutron Source FRANZ making use of the unique 250 kHz time structure. This contribution will provide an overview of the layout of the system as well as recent advances in component design and beam dynamics of the compressor.
Beam measurements with the new RFQ beam matching section at the Frankfurt Funneling Experiment
(2011)
Funneling is a method to increase low energy beam currents in multiple stages. The Frankfurt Funneling Experiment is a model of such a stage. The experiment is built up of two ion sources with electrostatic lens systems, a Two-Beam-RFQ accelerator, a funneling deflector and a beam diagnostic system. The two beams are bunched and accelerated in a Two-Beam RFQ. A funneling deflector combines the bunches to a common beam axis. A new beam transport system between RFQ accelerator and deflector has been constructed and mounted. With these extended RFQ-electrodes the drift between the Two-Beam-RFQ and the rf-deflector will be minimized and therefore unwanted emittance growth reduced. After first rf measurements current work are beam tests with the improved Two-Beam-RFQ. First results will be presented.
Mit der hier vorliegenden Arbeit ist das Entladungsverhalten einer Dielektrischen Barriere Entladung anhand der elektrischen Parameter untersucht worden. Dazu wurde ein planparallele Elektrodenkonfiguration entwickelt und aufgebaut, die mit einer Sinus-Spannungs von maximal 5000 Vss und einer Frequenz von 5 kHz-20 kHz angesteuert wurde. Als Arbeitsgas wurde Argon im Druckbereich von 100 mbar - 1000 mbar verwendet. Auf diese Weise konnte ein Plasma erzeugt werden, in das bei einer maximalen Transfereffiienz von 96%, eine mittlere Leistung von bis zu 845 mW eingekoppelt werden konnte.
Da die Dielektrische Barriere Entladung auf Grund der Abschirmung der Elektroden vom Gasraum einige Besonderheiten gegenüber eines klassischen kapazitiv eingekoppelten Plasmas aufweist, können keine Rückschlüsse mittels einer einfachen Strom-Spannungsmessung auf die Vorgänge im Plasma gemacht werden.
Um trotzdem Einblick in die Entladung zu erhalten, wurde das von [Tra08] vorgeschlagene Ladungstransportmodel für die Analyse herangezogen und an den hier vorliegenden experimentellen Aufbau angepasst. So konnte unter anderem der Ein
uss der auf den Dielektrika befindlichen Restladungsträger auf die Ausbildung der Entladung untersucht werden. Des Weiteren ist aus den gewonnen Größen die Elektronendichte des Plasmas bestimmt worden. Diese liegt bei der hier untersuchten dielektrischen Glimmentladung, je nach Gasdruck und Frequenz, im Bereich zwischen 5 X 10exp9 - 2 X 10exp10 1/cm3 . Auch konnten in diesem Zusammenhang qualitative Aussagen über die Entwicklung der Elektronentemperatur gemacht werden.
Zusammen mit Kurzzeitaufnahmen, die den Verlauf der Entladung dokumentieren und den in [Sch11] gemachten Untersuchungen zur Excimerstrahlung konnte so ein umfassendes Bild der Vorgänge im Plasma erstellt und Kriterien erarbeitet werden, die den für eine Dielektrische Barriere Entladung typischen Ubergang zwischen einer Glimmentladung zu einer filamentierten Entladung erklären können.
Chromatic, geometric and space charge effects on laser accelerated protons focused by a solenoid
(2011)
We studied numerically emittance and transmission effects by chromatic and geometric aberrations, with and without space charge, for a proton beam behind a solenoid in the laser proton experiment LIGHT at GSI. The TraceWin code was employed using a field map for the solenoid and an initial distribution with exponential energy dependence close to the experiment. The results show a strong effect of chromatic, and a relatively weak one of geometric aberrations as well as dependence of proton transmission on distance from the solenoid. The chromatic effect has an energy filtering property due to the finite radius beam pipe. Furthermore, a relatively modest dependence of transmission on space charge is found for p production intensity below 1011.
Fast thermalization and a strong build up of elliptic flow of QCD matter were investigated within the pQCD based 3+1 dimensional parton transport model BAMPS including bremsstrahlung 2 <-> 3 processes. Within the same framework quenching of gluonic jets in Au+Au collisions at RHIC can be understood. The development of conical structure by gluonic jets is investigated in a static box for the regimes of small and large dissipation. Furthermore we demonstrate two different approaches to extract the shear viscosity coefficient n from a microscopical picture.
Intense ion beams with small phase space occupation (high brilliance) are mandatory to keep beam losses low in high current injector accelerators like those planned for FAIR. The low energy beam transport from the ion source towards the linac has to keep the emittance growth low and has to support the optimization of the ion source tune. The Frankfurt Neutron Source Facility FRANZ is currently under construction. An intense beam of protons (2 MeV, 200 mA) will be used for neutron production using the Li7(p,n)Be7 reaction for studies of the astrophysical s-process. A collimation channel, which can be adjusted to allow the transport of beams with a certain beam emittance, is an ideal tool to optimize the ion source tune in terms of beam brightness. Therefore a collimation channel in the Low Energy Beam Transport section will be used. Through defined apertures and transversal phase space rotation using focusing solenoids the beam halo as well as unwanted H2+ and H3+ fractions will be cut. Theoretical studies which were carried out so far and a first design of the setup will be presented.
An optimized design of a stellarator-type storage ring for low energy ion beams was numerically investigated. The magnetic field variation along the circumference and therefore magnetic heating is suppressed by using simple circular correction coils. Particle-in-Cell (PIC) simulations in a magnetic flux coordinate system show the ability of high current ion beam accumulation in such a configuration with unique features for clockwise and anticlockwise moving beams. Additionally scaled down experiments with two 30 degree room temperature toroidal segments were performed to demonstrate toroidal transport and to develop optical beam diagnostics. Properties of multi-component beams, redistribution of transversal momenta in the non-adiabatic part of the experimental configuration and investigation of strongly confined beam induced electron clouds will be addressed.
We review our knowledge of the phase diagram of QCD as a function of temperature, chemical potential and quark masses. The presence of tricritical lines at imaginary chemical potential m = i p 3 T, with known scaling behaviour in their vicinity, puts constraints on this phase diagram, especially in the case of two light flavors. We show first results in our project to determine the finite-temperature behaviour in the Nf = 2 chiral limit.
Within the present work, photodissociation reactions on 100Mo, 93Mo and 92Mo isotopes were studied by means of the Coulomb dissociation method at the LAND setup at GSI. Experimental data on these isotopes are important to explain the problem of the underproduction of the lighter p-nuclei - 92; 94Mo - within the models of the p-process nucleosynthesis. The reaction rates used in the nucleosynthesis calculations are usually obtained within the framework of the statistical model. In order to verify the model predictions and reduce the uncertainties, experimental measurements of the reaction cross sections are required. In particular, the data on (γ,n) reactions are of interest, since these reactions were shown to dominate the p-process flow in the molybdenum mass region.
As a result of the analysis of the present experiment, integrated Coulomb excitation cross sections of the 100Mo(γ,n), 100Mo(γ,2n), 93Mo(γ,n) and 92Mo(γ,n) reactions were determined. The measurement of the 93Mo isotope is particularly important, since this nucleus is unstable, and the corresponding cross section has not been measured before.
It should be emphasized that Coulomb dissociation is a unique tool to study photoninduced reactions on unstable nuclei, which is especially relevant in the context of nucleosynthesis network calculations. However, because of to the complexity of the data analysis procedure and a number of model assumptions that are required in order to extract the Coulomb excitation cross section from the data, one of the main aspects of this thesis was to verify the method by comparing the results with the previously published data obtained with real photon beams. Integrated cross sections of the 100Mo(γ,n) and 100Mo(γ,2n) reactions were directly compared to the data by Beil et al., obtained at Saclay with photons from positron annihilation, while an indirect comparison could be performed with a recent photoactivation measurement by Erhard and co-workers. A reasonable agreement was observed for the 1n channel: a scaling factor of 0.8 ± 0.1 between our result and Beil et al. data is consistent with the scaling factor of 0.89±0.09 reported by Erhard et al. between their data and Beil et al. data. Both results are in agreement with the scaling factor of 0.85 ± 0.03 recommended by Berman et al. for the data measured at Saclay on nuclei in the respective mass region. A somewhat lower factor of 0.61 ± 0.09 between the present data and Beil et al. data was obtained for the 2n channel. The discrepancy might be explained by both the substantial efficiency correction that has to be applied to the LAND data in the two-neutron case, as well as by an insufficiently accurate assumption that the Saclay neutron detector efficiency is energy- and multiplicity- independent.
A second important topic of the present thesis is the investigation of the efficiency of the CsI gamma detector. The calorimetric information that it delivers is essential to reconstruct the energy-differential cross section from the present measurement. The data taken with the gamma calibration sources shortly after the experiment were used for the investigation. In addition, a test experiment in refined conditions was conducted within the framework of this thesis. Numerous GEANT3 simulations of the detector were performed in order to understand various aspects of its performance. As a result, the efficiency of the detector was determined to be approximately a factor of 2 lower than the efficiency expected from the simulation. This result is consistent with several independent investigations, which were performed using different methods. At the same time, a remarkable agreement between the simulated and experimental data was achieved under assumption that the inefficiency of the detector is explained by the loss of data from a number of crystals, which are randomly chosen in each event according to their averaged performance ratio (the ”on-off” effect). The reasons for the observed malfunction are yet not fully clear. Regardless of the exact reason, in the present conditions a deconvolution of the measured data from the CsI response is not possible. Consequently, within the framework of this thesis, the results are presented in terms of integrated cross sections. A search for alternative methods of data interpretation, allowing to extract energy-differential information out of the available data, in currently ongoing.
In the more recent experiments at the LAND setup, where the Crystal Ball gamma detector was used as a calorimeter, the reconstruction of the energy-differential cross section with a reasonable resolution was already shown to be feasible. It means that, even considering the uncertainties of the present experiment of the order of 10%, the uncertainties of the statistical model predictions, which are on average estimated to be within a factor of 1.5-2, can already be constrained.
The analysis of the present experiment is still in progress. As a next step, Coulomb excitation cross section for 94Mo will be obtained. The 94Mo(γ,n) reaction cannot be studied by photoactivation, since the life time of the daughter nucleus is too long (4000 y). At the same time, this reaction plays a key role in the p-process nucleosynthesis.
The future of the LAND setup - the R3B setup1 at FAIR2 - will take advantage of a three orders of magnitude higher intensity of the radioactive beams [85], as well as of a completely new detector system. High-resolution measurements of the energy-differential cross sections will be possible for exotic nuclei, which were never accessible in the laboratory before. Such measurements will open great opportunities for nuclear astrophysics, allowing to obtain high-quality experimental data even for regions of the nuclear chart where the statistical model calculations are not applicable.
Für das Helmholtzzentrum für Schwerionenforschung (GSI), in Darmstadt, wurde ein neuer RFQ zur Beschleunigung schwerer Ionen für den Hochladungsinjektor (HLI) entwickelt. Dieser RFQ hat den bereits vorhandenen ersetzt und soll, für die Anpassung des HLI an die neue 28 GHz-ECR-Ionenquelle, den Duty-cycle von 25 % auf 100 % erhöhen, um superschwere Ionen zu erzeugen und die Experimente mit schweren Ionen zu versorgen. Der RFQ hat die Aufgabe schwere, hochgeladene Ionen von 4 keV/u auf 300 keV/u zu beschleunigen. Wichtige Eigenschaften sind ein hoher Strahlstrom, eine hohe Strahl-Transmission, eine kleine Strahlemittanz und eine geringe transversale Emittanzzunahme. Die Erhöhung der Injektionsenergie von 2,5 keV/u auf 4 keV/u ermöglicht eine Verkleinerung des Konvergenzwinkels. Der Aufbau des 4-Rod-RFQs für den HLI ist Thema der vorliegenden Arbeit. Die Auslegung des HLI-RFQs bezieht sich auf ein festgelegtes max. Masse zu Ladungsverhältnis von A/q = 6, bei einer Betriebsfrequenz von 108,408 MHz. Die Ionen sollen bei einem Strahlstrom von 5 mA von 4 keV/u auf 300 keV/u beschleunigt werden. Durch die spezielle teilchendynamische Auslegung konnte die Länge des Tanks von vorher 3 m auf jetzt 2 m verkürzt werden. Dies begünstigt den CW-Betrieb der Struktur. Durch den CW-Betrieb hat man eine hohe Leistungsaufnahme, dies erfordert eine besondere teilchendynamische und hochfrequenztechnische Auslegung der RFQ-Struktur und eine effiziente Kühlung. Zur Simulation der Hochfrequenzeigenschaften wurde ein Modell des RFQ mit dem Programm Microwave Studio (MWS) erstellt. Die Simulationen ergaben einen nur 2 m langen RFQ mit sehr hoher Transmission > 95%. Nach den entsprechenden Simulationsrechnungen bezüglich der Teilchendynamik und der Hochfrequenzeigenschaften wurde der RFQ aufgebaut. Der zeitaufwändige Aufbau lässt sich in drei Abschnitte einteilen. Die Elektroden wurden präzise ausgemessen. Danach wurden Stützen, Elektroden und Tuningplatten an der Bodenplatte montiert und in den Tank eingesetzt. Im Tank wurden die Elektroden justiert, die zuerst außerhalb vermessen wurden. Die korrekte Position der Elektroden zur Referenzfläche wurde berechnet und mit Hilfe eines Faro-Gage im Tank eingemessen. Die maximale Abweichung der Elektrodenposition konnte auf 0,03 mm reduziert werden. Nach der mechanischen Einrichtung folgte die HF-Anpassung des Resonators. Durch das Erhöhen der Tuningplattenpositionen zwischen den Stützen konnte die Resonanzfrequenz von 90,8 MHz auf 108,4 MHz erhöht werden. Als nächstes wurde die Spannungsverteilung im Tank gemessen und mit Hilfe der Tuningplatten konnte sie so eingestellt werden, dass die maximale Abweichung zur mittleren Elektrodenspannung bei nur ± 2% liegt. Zur weiteren Hochfrequenzabstimmung wurde die Wirkung zweier Tauchkolben mit einem Durchmesser von 75 mm untersucht. Die Tauchkolben ermöglichen eine Anpassung der Frequenz im Bereich von 1,4 MHz. Sie sollen die möglichen Frequenzverschiebungen durch beispielsweise thermische Effekte, auf Grund des HF-Betriebs, regulieren. Für die Hochfrequenzabstimmung wurde eine Ankoppelschleife gefertigt und angepasst. Die Güte des Resonators betrug Q0 = 3100, bei einem RP-Wert RP = 100 kΩm, d.h. die zur Versorgung stehende HF-Leistung (50 kW im CW-Betrieb) reicht aus. An der GSI wurde nach dem Transport eine Kontrolle der Elektroden vorgenommen, danach wurde der RFQ erst einzeln, danach als komplette HLI Einheit getestet. Dazu wurden verschiedene Pulsmessungen und Emittanzmessungen mit Argon 7+ und Argon 8+ durchgeführt. Bei der ersten Strahlinbetriebnahme wurden die Transmission, die Ionenenergie und die Emittanz mit verschiedenen Ionen gemessen. Die ersten Tests des HLI-RFQ waren sehr vielversprechend. In den Tests war zu sehen, dass die vorgenommenen Arbeiten, wie Justage und HF-Abstimmung der Resonanzstruktur, erfolgreich waren. Danach wurde der Strahlbetrieb mit Calcium, bei einer Leistung von 50 kW, durchgeführt. Die gemessene Transmission bei einer Spannung von 43 kV lag bei 70 %. Im Mai 2010 gab es eine 14Stickstoff2+ -Strahlzeit mit einer gepulsten Leistung von N = 90 kW. Danach wurde Anpassungstests mit verschiedenen Schwerionen durchgeführt. Im November 2010 wurden neue Tuningplatten mit einer besseren Stützenkontaktierung sowie einer besseren Kühlung eingebaut. Die Elektroden wurden nach diesen Maßnahmen auf ± 0,04 mm einjustiert. Die Flatness liegt bei ± 2,1 %, die Güte beträgt Q0 = 3300. Der RFQ wurde in die Beamline eingebaut und geht im Januar 2011 in Betrieb.
Design and optimization of the lattice of the superconducting synchrotron SIS300 for slow extraction
(2011)
The superconducting synchrotron SIS300 is planned to be built at the new Facility for Antiproton and Ion Research (FAIR), at GSI-Darmstadt [1]. SIS300 will be a versatile machine, which by means of a low-energy stretcher-mode or a high-energy ramped-mode will provide slowly extracted heavy ion beams towards the experimental areas. To reach the required maximum field of 4.5 T, cos(θ) magnets are necessary. Thus, SIS300 will become the first superconducting synchrotron worldwide with cos(θ) magnets providing resonant slow extraction.
Since SIS300 will be installed in the same tunnel as the SIS100 synchrotron, the dipole layout of SIS300 cannot be freely chosen. Thus, a standard lattice cannot be applied. A redesign of the SIS300 lattice accepting compromises concerning the positions and phase advances between the optical elements has been proposed. Using the analytical model of the slow extraction, firstly proposed by Kobayashi, and the analytical description of the resonance driving modes, a multiobjective optimization algorithm has been developed for the optimization of the lattice under the given boundary conditions. The final goal of the lattice optimization is a higher efficiency of the slow extraction. The results are evaluated by means of tracking simulations performed with the code Elegant.
The field quality in superconducting cos(θ) magnets is determined by the positions of the superconducting cable and the static and time-dependent effects of the current in the cable. Furthermore, the fast ramp rates of 1 T/s in the dipoles, which are fifty times faster than in any other superconducting cos(θ) magnet, together with the fact that the aperture is smaller than in conventional accelerator magnets, makes it extremely difficult to obtain a high-quality magnetic field. The unavoidable field errors affect the beam dynamics and worsen the slow extraction efficiency. Therefore, the field errors in the SIS300 dipoles have been estimated, and their effects have been taken into account in the optimization algorithm. As a result a compensation scheme has been proposed, in which time-dependent gradients in the sextupoles counteract the decay of the sextupole field errors in the dipole magnets during the slow extraction. For the limits where the compensation was no longer possible, tolerances to the magnet field errors have been determined.
MYRRHA is conceived as an accelerator driven system (ADS) for transmutation of high level nuclear waste. The neutron source is created by coupling a proton accelerator of 600 MeV with a 4 mA proton beam, a spallation source and a sub-critical core. The IAP of Frankfurt University is responsible for the development of the 17 MeV injector operated at 176 MHz. The injector consists of a 1.5 MeV 4-Rod-RFQ and six CH-drifttube-structures. The first two CH-structures will be operated at room temperature and the other CH-structures are superconducting cavities assembled in one cryo-module. To achieve the extremely high reliability required by the ADS application, the design of the 17 MeV injector has been intensively studied, with respect to thermal issues, minimum peak fields and field distribution.