Institutes
Refine
Document Type
- Article (2)
Language
- English (2)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Keywords
- additive manufacturing (1)
- liver cancer (1)
- open-source 3D bioprinting (1)
- organoids (1)
- stereolithography (1)
- tumor microenvironment (1)
- tumor model (1)
Institute
- Buchmann Institut für Molekulare Lebenswissenschaften (BMLS) (2) (remove)
A widespread application of 3D bioprinting in basic and translational research requires accessibility to affordable printers able to produce physiologically relevant tissue models. To facilitate the use of bioprinting as a standard technique in biology, an open-source device based on a consumer-grade 3D stereolithography apparatus (SLA) printer is developed. This SLA bioprinter can produce complex constructs that preserve cell viability and recapitulate the physiology of tissues. The detailed documentation of the modifications apported to the printer as well as a throughout performance analysis allow for a straightforward adoption of the device in other labs and its customization for specific applications. Given the low cost, several modified bioprinters could be simultaneously operated for a parallelized tissue production. To showcase the capability of the bioprinter, constructs consisting of patient-derived cholangiocarcinoma organoids encapsulated in a gelatin methacrylate (GelMA)/polyethylene glycol diacrylate (PEGDA) hydrogel are produced. A thorough characterization of different GelMA/PEGDA ratios reveals that the mechanical properties of the bioprinted tumor model can be accurately fine-tuned to mimic a specific tumor micro-environment. Immunofluorescence and gene expression analyses of tumor markers confirm that the bioprinted synthetic hydrogel provides a flexible and adequate replacement of animal-derived reconstituted extracellular matrix.
Cryo-electron tomography is the only technique that can provide sub-nanometer resolved images of cell regions or even whole cells, without the need of labeling or staining methods. Technological advances over the past decade in electron microscope stability, cameras, stage precision and software have resulted in faster acquisition speeds and considerably improved resolution. In pursuit of even better image resolution, researchers seek to reduce noise – a crucial factor affecting the reliability of the tomogram interpretation and ultimately limiting the achieved resolution. Sub-tomogram averaging is the method of choice for reducing noise in repetitive objects. However, when averaging is not applicable, a trade-off between reducing noise and conserving genuine image details must be achieved. Thus, denoising is an important process that improves the interpretability of the tomogram not only directly but also by facilitating other downstream tasks, such as segmentation and 3D visualization. Here, I review contemporary denoising techniques for cryo-electron tomography by taking into account noise-specific properties of both reconstruction and detector noise. The outcomes of different techniques are compared, in order to help researchers select the most appropriate for each dataset and to achieve better and more reliable interpretation of the tomograms.