• Treffer 5 von 6
Zurück zur Trefferliste

Extensive aortic surgery in acute aortic dissection type A on outcome – insights from 25 years single center experience

  • Background: This single center study compares the different surgical techniques used in the treatment of acute aortic dissection type A (AADA) analyzing the influence of the extent of the surgical approach on outcome. Methods: From 1988 to 2012, 407 patients were operated for AADA. The cohort was divided into subgroups according to the surgical approach. These groups were compared with the supracommissural replacement group (SCR; n = 141). Groups included aortic valve sparing techniques (AVS; n = 29), Composite replacement (COMP; n = 119), COMP with total arch replacement (COMP+TAR; n = 27) and SCR with TAR (n = 75). Results: Compared to SCR alone, operation (p = 0.005), bypass-, cross-clamp and circulatory arrest times were longer in SCR + TAR (all p < 0.001). Moreover, operation, bypass and cross clamp times were longer in COMP+TAR (p = 0.003, p = 0.002 and p < 0.001 respectively). COMP alone and AVS required longer cross-clamp time, too (p < 0,001 and p = 0.002, respectively). Overall 30-day mortality was 21% with the observed lowest rate after AVS (14%, SCR 18%, COMP 25%) but differences in 30-day mortality were not statistically significant. The estimated 10-year survival was 42%, especially AVS demonstrated a good 10-year survival (69%). David technique was superior to Yacoub technique concerning incidence of redo interventions (p = 0.036). Risk factors for early mortality included age, circulatory arrest, general malperfusion, bypass and operation time. Circulatory arrest per se was revealed as risk factor for long-term survival. Conclusions: Within our single center retrospective study concomitant aortic root repair or aortic arch replacement for AADA demonstrated acceptable early and long-term survival. Circulatory arrest, long bypass and operation times per se might be important risk factors for early mortality. AVS techniques can be performed safely and have good outcomes in acute aortic dissection repair.

Volltext Dateien herunterladen

Metadaten exportieren

Metadaten
Verfasserangaben:Bashar Dib, Philipp SeppeltORCiDGND, Rawa Arif, Alexander WeymannGND, Gábor I. VeresORCiD, Bastian SchmackGND, Carsten J. Beller, Arjang Ruhparwar, Matthias Karck, Klaus KallenbachORCiD
URN:urn:nbn:de:hebis:30:3-529744
DOI:https://doi.org/10.1186/s13019-019-1007-7
ISSN:1749-8090
Pubmed-Id:https://pubmed.ncbi.nlm.nih.gov/31694667
Titel des übergeordneten Werkes (Englisch):Journal of cardiothoracic surgery
Verlag:BioMed Central
Verlagsort:London
Dokumentart:Wissenschaftlicher Artikel
Sprache:Englisch
Jahr der Fertigstellung:2019
Datum der Erstveröffentlichung:06.11.2019
Veröffentlichende Institution:Universitätsbibliothek Johann Christian Senckenberg
Datum der Freischaltung:02.03.2020
Freies Schlagwort / Tag:Aortic arch replacement; Aortic dissection; Aortic valve sparing; David technique
Jahrgang:14
Ausgabe / Heft:1, Art. 187
Seitenzahl:10
Erste Seite:1
Letzte Seite:10
Bemerkung:
Open Access: This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
HeBIS-PPN:46142259X
Institute:Medizin / Medizin
DDC-Klassifikation:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Sammlungen:Universitätspublikationen
Lizenz (Deutsch):License LogoCreative Commons - Namensnennung 4.0