Occurrence of vasospasm and infarction in relation to a focal monitoring sensor in patients after SAH: placing a bet when placing a probe?
- Introduction: Vasospastic brain infarction is a devastating complication of aneurysmal subarachnoid hemorrhage (SAH). Using a probe for invasive monitoring of brain tissue oxygenation or blood flow is highly focal and may miss the site of cerebral vasospasm (CVS). Probe placement is based on the assumption that the spasm will occur either at the dependent vessel territory of the parent artery of the ruptured aneurysm or at the artery exposed to the focal thick blood clot. We investigated the likelihood of a focal monitoring sensor being placed in vasospasm or infarction territory on a hypothetical basis. Methods: From our database we retrospectively selected consecutive SAH patients with angiographically proven (day 7–14) severe CVS (narrowing of vessel lumen >50%). Depending on the aneurysm location we applied a standard protocol of probe placement to detect the most probable site of severe CVS or infarction. We analyzed whether the placement was congruent with existing CVS/infarction. Results: We analyzed 100 patients after SAH caused by aneurysms located in the following locations: MCA (n = 14), ICA (n = 30), A1CA (n = 4), AcoA or A2CA (n = 33), and VBA (n = 19). Sensor location corresponded with CVS territory in 93% of MCA, 87% of ICA, 76% of AcoA or A2CA, but only 50% of A1CA and 42% of VBA aneurysms. The focal probe was located inside the infarction territory in 95% of ICA, 89% of MCA, 78% of ACoA or A2CA, 50% of A1CA and 23% of VBA aneurysms. Conclusion: The probability that a single focal probe will be situated in the territory of severe CVS and infarction varies. It seems to be reasonably accurate for MCA and ICA aneurysms, but not for ACA or VBA aneurysms.
Author: | Christian T. Ulrich, Christian Fung, Hartmut VatterORCiDGND, Matthias Setzer, Erdem Özer GüresirORCiDGND, Volker SeifertORCiD, Jürgen Beck, Andreas RaabeORCiDGND |
---|---|
URN: | urn:nbn:de:hebis:30:3-294978 |
DOI: | https://doi.org/10.1371/journal.pone.0062754 |
ISSN: | 1932-6203 |
Parent Title (English): | PLoS One |
Publisher: | PLoS [u.a.] |
Place of publication: | Lawrence, Kan. |
Document Type: | Article |
Language: | English |
Date of first Publication: | 2013/05/02 |
Publishing Institution: | Universitätsbibliothek Johann Christian Senckenberg |
Release Date: | 2013/05/03 |
Volume: | 8 |
Issue: | (5): e62754 |
Page Number: | 6 |
Note: | Copyright: © 2013 Ulrich et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
HeBIS-PPN: | 338742468 |
Institutes: | Medizin / Medizin |
Dewey Decimal Classification: | 6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit |
Sammlungen: | Universitätspublikationen |
Licence (German): | Creative Commons - Namensnennung 3.0 |