Refine
Year of publication
- 2008 (64) (remove)
Document Type
- Doctoral Thesis (21)
- Article (17)
- diplomthesis (6)
- Conference Proceeding (5)
- Diploma Thesis (4)
- Bachelor Thesis (3)
- Book (3)
- Part of Periodical (2)
- Habilitation (1)
- Preprint (1)
Has Fulltext
- yes (64) (remove)
Is part of the Bibliography
- no (64)
Keywords
- LHC (3)
- Spektroskopie (3)
- ALICE <Teilchendetektor> (2)
- CERN (2)
- Datenanalyse (2)
- Elementarteilchen (2)
- Kernphysik (2)
- Quark-Gluon-Plasma (2)
- Schwerionenkollisionen (2)
- Schwerionenphysik (2)
Institute
- Physik (64) (remove)
We present a measurement of e+e− pair production in central PbAu collisions at 158A GeV/c. As reported earlier, a significant excess of the e+e− pair yield over the expectation from hadron decays is observed. The improved mass resolution of the present data set, recorded with the upgraded CERES experiment at the CERN-SPS, allows for a comparison of the data with different theoretical approaches. The data clearly favor a substantial in-medium broadening of the ρ spectral function over a density-dependent shift of the ρ pole mass. The in-medium broadening model implies that baryon induced interactions are the key mechanism to the observed modifications of the ρ meson at SPS energy.
The extrapolation of results obtained on a series of 3 succeeding grids with halved mesh size is tested as a variant of the multigrid approach for solving the Laplace and Poisson equations in 2D. Based on corresponding experience with BEM for electric and magnetic [2] field problems a pure power law is applied instead of the famous Richardson extrapolation [3]. On those grid points, which are common to all 3 grids, the potential values are extrapolated to an arbitrary fine discretization. On the points of the finest grid in between those of the coarser ones the potentials then are obtained by only few iterations to perform the interpolation. Both, the common 5-point discretization and the famous 9-point discretization by E. Kasper [5] are investigated and compared with respect to the possible win of accuracy by extrapolation. As an interesting result of this kind of extrapolation, the accumulated local discretization errors of the 5-point discretization are partially cured and the high accuracy by the 9-point formula of Kasper makes extrapolation inefficient. Like for classical MG (multi grid) [6] the acceleration of potential calculations on grids of large size is substantial.
Dilepton production in pp and Au+Au nucleus–nucleus collisions at s=200GeV as well as in In+In and Pb+Au at 158AGeV is studied within the microscopic HSD transport approach. A comparison to the data from the PHENIX Collaboration at RHIC shows that standard in-medium effects of the ρ,ω vector mesons—compatible with the NA60 data for In+In at 158AGeV and the CERES data for Pb+Au at 158AGeV—do not explain the large enhancement observed in the invariant mass regime from 0.2 to 0.5 GeV in Au+Au collisions at s=200 GeV relative to pp collisions.
We explore the formation of diquark bound states and their Bose–Einstein condensation (BEC) in the phase diagram of three-flavor quark matter at nonzero temperature, T, and quark chemical potential, μ. Using a quark model with a four-fermion interaction, we identify diquark excitations as poles of the microscopically computed diquark propagator. The quark masses are obtained by solving a dynamical equation for the chiral condensate and are found to determine the stability of the diquark excitations. The stability of diquark excitations is investigated in the T–μ plane for different values of the diquark coupling strength. We find that diquark bound states appear at small quark chemical potentials and at intermediate coupling strengths. Bose–Einstein condensation of non-strange diquark states occurs when the attractive interaction between quarks is sufficiently strong.
We propose that the measurement of the transverse momentum dependence of the double ratio of the nuclear modification factors of charm and bottom jets, RAAc(pT)/RAAb(pT), in central nuclear collisions at the LHC will provide an especially robust observable that can be used to differentiate Standard Model perturbative QCD predictions from recently proposed strong coupling string drag models derived using the AdS/CFT conjecture.
Based on the microscopic transport model UrQMD in which hadronic and string degrees of freedom are employed, the HBT parameters in the longitudinal co-moving system are investigated for charged pion and kaon, and Λ sources in heavy ion collisions (HICs) at SPS and RHIC energies. In the Cascade mode, RO and the RL at high SPS and RHIC energies do not follow the mT-scaling, however, after considering a soft equation of state with momentum dependence (SM-EoS) for formed baryons and a density-dependent Skyrme-like potential for “pre-formed” particles, the HBT radii of pions and kaons and even those of Λs with large transverse momenta follow the mT-scaling function R=3/mT fairly well.
We determine the hard-loop resummed propagator in an anisotropic QCD plasma in general covariant gauges and define a potential between heavy quarks from the Fourier transform of its static limit. We find that there is stronger attraction on distance scales on the order of the inverse Debye mass for quark pairs aligned along the direction of anisotropy than for transverse alignment.
It has been suggested that the existence of a non-Gaussian fixed point in general relativity might cure the ultraviolet problems of this theory. Such a fixed point is connected to an effective running of the gravitational coupling. We calculate the effect of the running gravitational coupling on the black hole production cross section in models with large extra dimensions.
Im Rahmen dieser Arbeit wurde der am Frankfurter Institut für Kernphysik verwendete Aufbau zum Test der Front End Elektronik des ALICE Übergangsstrahlungsdetektors fertig gestellt und in Betrieb genommen. Die dazu benötigte Hard- und Software wurde auf entsprechenden Computersystemen installiert und für einen möglichst benutzerfreundlichen Ablauf der FEE-Tests angepasst, modifiziert und ergänzt.
In dieser Arbeit wurde der Aufbau und die Funktionsweise der ALICE TRD Ausleseelektronik beschrieben. Es wurden die einzelnen Testprozeduren, und darüber hinaus wie diese Prozeduren ein Höchstmaß an Funktionalität der FEE gewährleisten, diskutiert. Es wurde weiterhin diskutiert welche qualitativen und quantitativen Kriterien angewendet wurden um eine maximale Zuverlässigkeit der FEE zu garantieren. Die Grundlagen und die Funktionalität des Pulser-Testes wurden dabei besonders beleuchtet.
Die Hauptaufgabe, die mit dieser Diplomarbeit erfüllt werden sollte, stellt die Entwicklung einer graphischen Benutzeroberfläche dar, die alle test-relevanten Informationen zusammenfasst und aufbereitet. Die ALICE TRD Supermodule II bis V wurden über Skripte von der Kommandozeile aus getestet. Mit dem Supermodul VI wurde der Übergang zu diesem PVSS II - basierten graphischen Benutzerinterface vollzogen, so das es nun möglich ist die FEE der Auslesekammern für die Supermodule VII bis XVIII, also mindestens 720 Testdurchläufe, über diese Schnittstelle zu testen.
Die Weiterentwicklung, Verbesserung und Anpassung des graphischen Benutzerinterfaces an die Bedürfnisse des Testers ergibt sich dementsprechend als eine der sich an diese Arbeit anschließenden Aufgaben. Des Weiteren zählen zu diesen Aufgaben die Erweiterung der Tests um neue Komponenten und die Verbesserung der Datenarchivierung. Neben diesen Änderungen am Testsystem stellt sich die Aufgabe, ein möglichst stabiles und zuverlässiges Testsystem aufrecht zu erhalten, um immer einen gleichbleibenden, hohen Qualitätsstandart in vordefinierten Zeitrahmen liefern zu können.
Die vorliegende Arbeit präsentiert den Aufbau und die Diagnostik eines Niederdruck-HF-Plasmas. Durchgeführt wurden die Messungen in einem Gasgemisch aus Ar/He (50%=50%). Sie dienten dazu, nähere Einblicke in die Plasmaparameter eines HF-Plasmas zu erhalten. Einen Schwerpunkt der vorliegenden Arbeit bildete dabei die Auswirkung unterschiedlicher Antennengeometrien auf die Entladungseigenschaften. Hierfür wurden die Plasmaparameter Elektronentemperatur Te, Elektronendichte ne und HF-Leistung in Abhängigkeit des Gasdruckes bei einer Vorwärtsleistung des HF-Generators von 1kW untersucht. Um eine sinnvolle Diagnostik zu gewährleisten, war es zunächst erforderlich eine induktive HF-Einspeisung zu konzipieren und eine Impedanzanpassung an dem vorhandenen 13,56MHz Generator vorzunehmen. Die Einspeisung der HF-Leistung geschieht über eine Spule, nach dem Transformatorprinzip. Der Aufbau bietet die Möglichkeit einer modularen Gestaltung der verwendeten Antennengeometrie. Hierdurch ist es möglich, sowohl die Länge, die Windungsbreite als auch die Windungsanzahl schnell zu ändern, um experimentell ein Optimum der Plasmaparameter bezüglich der Plasmaanregung zu erreichen.
Für die Bestimmung der Plasmaparameter wurde vorwiegend eine nicht invasive Diagnostiktechnik, die Emissionsspektroskopie, eingesetzt. Sie bietet den Vorteil, ein Plasma unberührt zu lassen und dessen Eigenschaften nicht zu verfälschen. Zusätzlich wurde mit einer Langmuirsonde die Elektronendichte gemessen. Die eingespeiste HF-Leistung wurde mit einem im HF-Generator befindlichen Reflektometer überwacht und dokumentiert. Durch systematisch durchgeführte Messungen konnte die Elektronentemperatur in Abhängigkeit des Gasdruckes für unterschiedliche Spulengeometrien mit Hilfe der Spektroskopie bestimmt werden. Es ergaben sich typische Elektronentemperaturen einer induktiven Entladung zwischen 1 eV und 5 eV. Die Ursache einer höheren Elektronentemperatur bei niedrigen Gasdrücken, unterhalb von 1 Pa, kann durch die stochastische Heizung sowie resonante Heizmechanismen erklärt werden.
Die mit der Langmuirsonde bestimmte Elektronendichte belief sich auf 4 x 10 exp 15 m exp -3 bei niedrigen Gasdrücken und einem Maximum von 4 x 10 exp 17 m exp -3 bei einem Gasdruck von 3 Pa. Elektronendichten dieser Größenordnung sind typisch für induktive Entladungsplasmen, die ein Maximum von 1019 m exp -3 [Lie05] erreichen können.
Die eingespeiste HF-Leistung zeigte dabei eine starke Abhängigkeit von der Antennengeometrie. Durch die Optimierung der Spulenkonfiguration ergab sich eine maximale eingespeisten HF-Leistung von 0,8kW.
Ein Vergleich von HF-Leistung und Elektronendichte bestätigte die theoretische Modellvorstellung, die einen linearen Zusammenhang zwischen diesen beiden Größen postuliert. Somit konnten wichtige Eigenschaften bezüglich einer HF-Entladung sowie Einflüsse der Antennengeometrie auf die Entladungseigenschaften untersucht und umfangreich diskutiert werden.
Mit dieser Arbeit wurde gezeigt, wie sich Störung und Kopplung auf ein System zwei gekoppelter Resonatoren auswirkt. Das Einfahren des Tauchkolbens birgt die Möglichkeit die Eigenfrequenzen des Systems zu verändern und die Feldverteilungen anzupassen. Ein Tauchkolben auf der anderen Seite des Resonators wäre für die Anschauung der Störung praktisch gewesen, hätte jedoch keine weiteren Erkenntnisse geliefert.
Es ist möglich mit zwei verschiedenen eingekoppelten Frequenzen eine Schwebung im Resonator zu erzeugen. Dies könnte theoretisch für eine Hochfrequenzstrahlablenkung nützlich sein. Mit einer speziell auf Strahlablenkung optimierten Resonatorgeometrie gilt es dies praktisch zu überprüfen.
In dem in dieser Arbeit vorgestellten Experiment wurde die Reaktion zwischen molekularem Wasserstoff und hochgeladenen langsamen Ar8+-Ionen untersucht. Ein Augenmerk wurde hierbei auf den Zweifachelektroneneinfang gelegt.
Anhand zwei durchgeführten Messungen mit unterschiedlichen Projektilgeschwindigkeiten 0,2 und 0,36 a.u. und unter zur Hilfenahme des so genannten „over-barrier-Modells“ sollte die Dynamik des H2-Moleküls während des Elektroneneinfangprozesses untersucht werden. Aus den daraus resultierten Ergebnissen sollte die Frage, ob der Einfangsprozess simultan oder sequentiell stattgefunden hat beantwortet werden.
Durch einfache Berechnungen kann mit dem „over-barrier-Modell“ die Distanz, welche das Projektil zwischen dem ersten und dem zweiten Elektroneneinfang zurücklegt, in Abhängigkeit von dem Stoßparameter ermittelt werden. Dieser Wert ist der Hauptbestand aller weiteren Berechnungen.
Die Spektren der Impulsüberträge in Abhängigkeit von der Ausrichtung des Moleküls zu dem Projektilstrahl haben gezeigt, dass das Projektil meist über und unter der Molekülachse streut anstatt links oder rechts am Molekül vorbei zu fliegen.
Die Auftragung der kinetischen Energie der Fragmente gegen den Transversalimpuls des Projektils (Abbildung 5.6) hat ergeben, dass größere Impulsüberträge für den Fall der senkrechten Stellung des Moleküls zu der Strahlachse, zu leicht erhöhten Aufbruchsenegien führt, was durch die Berechnung der Energie zu erklären ist.
Aus der Verteilung der kinetischen Energie (KER), welche die durch Dissoziation entstandenen Wasserstoffionen nach dem Stoß besitzen, kann auf den Verlauf der Reaktion zurück geschlossen werden.
Ein Vergleich der KER-Spektren für unterschiedliche Stoßparameter (Abbildung 5.8 und 5.9) bei festen Geschwindigkeiten hat für die zwei Messungen widersprüchliche Ergebnisse gezeigt. Zu erwarten war eine Verkleinerung der Energiewerte bei ansteigendem Stoßparameter. Dies konnte jedoch nur für den Fall in welchem die Projektilgeschwindigkeit 0,36 a.u. betrug bestätigt werden. Die Abweichung bei der ersten Messung kann durch statistische Fehler kommen, da die Anzahl der Messwerte, die für diese Messungen als „richtige“ angenommen worden, durch das Setzen von verschiedenen Bedingungen stark reduziert wurde.
Letztendlich wurde anhand der Variation der Stoßparameter bei festen Projektilgeschwindigkeiten die Zeitskala während des Stoßes eingeschätzt. Es wurde die Annahme getroffen, dass der Zweifachelektroneneinfang als zweistufiger Prozess abgelaufen ist und die maximal mögliche Zeitspanne zwischen dem ersten und dem zweiten Elektroneneinfang berechnet. Der Vergleich der daraus resultierten Werte mit der Oszillationsdauer des Wasserstoffmoleküls hat die getroffene Annahme widerlegt. Beide Messungen sind laut „over-barrier-Modell“ als einstufiger, schneller Übergang einzuordnen.
Das Ziel dieser Diplomarbeit war die Untersuchung der Reaktion des Zweifachelektroneneinfangs mit einem Augenmerk auf den Unterschied zwischen dem simultanen und dem sequentiellen Verlauf. Die Ergebnisse haben einen zweistufigen Prozess mit hoher Wahrscheinlichkeit ausgeschlossen. Obwohl alle theoretischen Anforderungen für den Einsatz des „over-barrier-Modells“ erfüllt worden sind, hat sich herausgestellt, dass die gemessenen Werte nicht immer eindeutig interpretiert werden konnten. Das lässt darauf schließen, dass das Experiment noch verbessert werden kann, um mögliche Fehlerquellen zu reduzieren. Eine Möglichkeit zur Verbesserung wäre der Einbau eines Elektronendetektors, oder aber die Änderung des Projektilions. Auch längere Messzeiten wären statistisch gesehen von Vorteil. Für die Zukunft sind weitere Experimente mit veränderten Targetgasen und geänderten Projektilgeschwindigkeiten geplant.
Die HBT-Interferometrie bietet über die Analyse von Bose-Einstein-Korrelationen geladener Pionen die Möglichkeit, Raumzeit-Dimensionen von Kern-Kern-Reaktionen zu vermessen. Dadurch kann das Ausfrierverhalten der in diesen Reaktionen enstehenden teilchenemittierenden Quelle untersucht werden. Die so gewonnenen Informationen tragen zu einem Verständnis der in den Kollisionen ablaufenden Prozesse und somit zu Erkenntnissen über Kernmaterie unter extremen Bedingungen bei. Von besonderem Interesse ist dabei die Beobachtung der Ausbildung eines QGP-Zustandes. Hierfür sind systematische Studien von verschiedenen Kollisionssystemen und -energien von großer Bedeutung.
Im Rahmen dieser Arbeit wurde eine Analyse von Bose-Einstein-Korrelationen in Pb-Au-Kollisionen bei einer Strahlenergie von 80A GeV durchgeführt. Die hier analysierten Daten wurden mit dem CERES-Detektor am SPS-Beschleuniger des CERN aufgenommen. Diese Analyse stellt eine erneute Untersuchung des Datensatzes unter Verwendung einer verbesserten Kalibrierungsprozedur für den CERES-Detektor dar. Infolgedessen konnte eine Verringerung der systematischen Unsicherheiten erreicht werden. Die neuen Ergebnisse stimmen mit den von der CERES-Kollaboration bereits publizierten HBT-Ergebnissen zufriedenstellend überein. Der Vergleich mit den Ergebnissen des NA49-Experiments, dass Pb-Pb-Kollisionen bei gleicher Strahlenergie unter dem Aspekt der HBT-Interferometrie untersucht hat, zeigt ebenfalls eine Übereinstimmung.
Durch diese Konsistenz und die Minimierung der systematischen Unsicherheiten im Bereich der SPS-Energien wird nun die Interpretation des Ausfrierverhaltens der Quelle besser ermöglicht: In dieser Arbeit wurde eine universelle Ausfrierbedingung von Pionen bei unterschiedlichen Schwerpunktsenergien und für verschiedene Kollisionssysteme untersucht. Diesbezügliche Observablen sind das mittels HBT-Radien bestimmte Ausfriervolumen und die mittlere freie Weglänge von Pionen zum Zeitpunkt des Ausfrierens der Quelle.
Bei dieser Untersuchung in Abhängigkeit von der Schwerpunktsenergie der Kollision zeichnet sich ein Minimum des Ausfriervolumens bei hohen AGS- und niedrigen SPS-Energien ab. Zusätzlich ergibt sich für die mittlere freie Weglänge ein ebenfalls nicht monotones Verhalten in diesem Energiebereich. Aus der dort vergrößerten Weglänge lässt sich auf eine erhöhte Emissiondauer der teilchenemittierenden Quelle gegenüber anderen Energien schließen. Die Emissionsdauer spielt in Verbindung mit dem Nachweis eines QGP-Zustandes eine wichtige Rolle. Ob die beschriebenen Beobachtungen durch ein Ausbilden dieses Zustandes oder auf Grund von anderen unbekannten Mechanismen hervorgerufen werden, kann abschließend noch nicht beurteilt werden. Denn verbleibende systematischen Unsicherheiten bei niedrigen Schwerpunktsenergien lassen derzeit keine weiteren Interpretationen zu. Insbesondere betrifft dies die noch bestehende Diskrepanz der Ergebnisse zwischen CERES und NA49 für eine Strahlenergie von 40A GeV. Daher ist eine Reanalyse der Daten von CERES bei dieser Strahlenergie von Bedeutung. Ebenso würde eine erneute systematische Messung im AGS-Energiebereich weitere grundlegende Interpretationen ermöglichen.
In Zukunft werden am RHIC-Beschleuniger des BNL in den USA und im Rahmen des FAIR-Projektes an der GSI bei Darmstadt Experimente in dieser Energieregion durchgeführt werden. Möglicherweise kann dann anhand dieser Messung ein universelles Ausfrierkriterium für Pionen sowie der Grund für ein verändertes Systemverhalten bei bestimmten Energien festgestellt werden.
Zentralitätsabhängigkeit der Produktion von Protonen und Antiprotonen in Pb+Pb Stößen bei 158A GeV
(2008)
Fachspezifischer Anhang zur SPoL (Teil III): Studienfach Physik in den Studiengängen L2 und L5
(2008)
We report progress in our exploration of the finite-temperature phase structure of two-flavour lattice
QCD with twisted-mass Wilson fermions and a tree-level Symanzik-improved gauge action
for a temporal lattice size Nt = 8. Extending our investigations to a wider region of parameter
space we gain a global view of the rich phase structure. We identify the finite temperature transition/
crossover for a non-vanishing twisted-mass parameter in the neighbourhood of the zerotemperature
critical line at sufficiently high b . Our findings are consistent with Creutz’s conjecture
of a conical shape of the finite temperature transition surface. Comparing with NLO lattice
cPT we achieve an improved understanding of this shape.
We perform a detailed study of the adjoint static potential in the pseudoparticle approach, which is a model for SU(2) Yang-Mills theory. We find agreement with the Casimir scaling hypothesis and there is clear evidence for string breaking. At the same time the potential in the fundamental representation is linear for large separations. Our results are in qualitative agreement with results from lattice computations.
We present the status of runs performed in the twisted mass formalism with Nf =2+1+1 flavours of dynamical fermions: a degenerate light doublet and a mass split heavy doublet. The procedure for tuning to maximal twist will be described as well as the current status of the runs using both thin and stout links. Preliminary results for a few observables obtained on ensembles at maximal twist will be given. Finally, a reweighting procedure to tune to maximal twist will be described.
We investigate the implications of the r-modes instability on the composition of a compact star rotating at a sub-millisecond period. In particular, the only viable astrophysical scenario for such an object, wich might present inside the Low Mass X-ray Binary associated with the x-ray transient XTE J1739-285, is that it has a strangeness content. Since previous analysis indicate that hyperonic stars or stars containing a kaon condensate are unlikely because of the mass-shedding constraint, the only remaining possibility is that such an object is either a strange quark star or a hybrid quark-hadron star.
The possible role of a first order QCD phase transition at nonvanishing quark chemical potential and temperature for cold neutron stars and for supernovae is delineated. For cold neutron stars, we use the NJL model with nonvanishing color superconducting pairing gaps, which describes the phase transition to the 2SC and the CFL quark matter phases at high baryon densities. We demonstrate that these two phase transitions can both be present in the core of neutron stars and that they lead to the appearance of a third family of solution for compact stars. In particular, a core of CFL quark matter can be present in stable compact star configurations when slightly adjusting the vacuum pressure to the onset of the chiral phase transition from the hadronic model to the NJL model. We show that a strong first order phase transition can have strong impact on the dynamics of core collapse supernovae. If the QCD phase transition sets in shortly after the first bounce, a second outgoing shock wave can be generated which leads to an explosion. The presence of the QCD phase transition can be read off from the neutrino and antineutrino signal of the supernova.
P-type ATPases are membrane proteins acting as ion pumps that drive an active transport of cations across the membrane against a concentration gradient. The required energy for the ion transport is provided by binding and hydrolysis of ATP. A reaction mechanism of ion transport and energy transduction is assumed to be common for all P-type ATPases and generally described by the Post-Albers cycle. Transient currents and charge translocation of P-type ATPases were extensively investigated by electrical measurements that apply voltage jumps to initiate the reaction cycle. In this study, we simulate an applied voltage across the membrane by an electric field and perform electrostatic calculations in order to verify the experimentally-driven hypothesis that the energy transduction mechanism is regulated by specific structural elements. Side chain conformational and ionization changes induced by the electric field are evaluated for each transmembrane helix and the selectivity in response is qualitatively analyzed for the Ca2+-ATPase as well as for structural models of the Na+/K+-ATPase. Helix M5 responds with more conformer changes as compared to the other transmembrane helices what is even more emphasized when the stalk region is included. Thus our simulations support experimental results and indicate a crucial role for the highly conserved transmembrane helix M5 in the energy transduction mechanism of P-type ATPases.
Das HADES-Experiment (High Acceptance DiElectron Spectrometer) am SIS der GSI wurde zur Messung der e+e−-Paare dileptonischer Zerfälle der leichten Vektormesonen im Energiebereich von 1 − 2 AGeV entwickelt. Eine der Hauptanforderungen an das Spurverfolgungssystem des Spektrometers ist eine Ortsauflösung von 100 μm, die benötigt wird, um die geforderte Massenauflösung von 1 % im Bereich der !-Masse zu erzielen. Das Spurverfolgungssystem besteht aus vier Ebenen mit Vieldrahtdriftkammern (Multi-wire Drift Chambers (MDCs)) niedriger Massenbelegung (low-mass), die aus je 6 Auslesedrahtebenen bestehen. Die primäre Messgröße von Driftkammern ist die Driftzeit der entlang einer Teilchenspur generierten Elektronen der Primärionisation zum Auslesedraht. Um die gemessene Driftzeit in eine Ortskoordinate umrechnen zu können, ist eine genaue Kenntnis der Ort-Zeit-Korrelation der Driftzellen und eine präzise Kalibrierung der gemessenen Zeiten nötig. Im Rahmen dieser Arbeit wurde eine neue Methode zur Bestimmung der Kalibrierungsparameter der Driftzeiten mittels der Einkoppelung eines externen elektrischen Pulses auf die Drahtebenen der Driftkammern entwickelt und mit der herkömmlichen Methode der Kalibrierung verglichen. Zur Kalibrierung wurden elektrische Pulse durch die Hochspannungsverteilung der Driftkammern auf die Potentialdrahtebenen geleitet und somit Signale auf die Signaldrähte induziert. Die Ausbreitungsgeschwindigkeit der Signale auf den Drähten, die zur Berücksichtigung der Laufzeiten benötigt wird, wurde experimentell bestimmt. Die Genauigkeit der Methode zur Bestimmung der Kalibrierungsparameter übertrifft die Auflösung der Driftzeitmessung der Driftkammern. Die Kalibrierung der Driftzeiten benötigt nur wenig Rechen- und Zeitaufwand und stellt die Kalibrierungsparameter in gleich hoher Präzision für alle Driftzellen zur Verfügung. Die Qualität der Kalibrierung wird im Gegensatz zur herkömmlichen Methode prinzipbedingt nicht durch Fluktuationen der Startzeit des jeweiligen Stoßereignisses und die Flugzeit der dabei emittierten Teilchen zu den Driftzellen, sowie des elektronischen Rauschens beeinflusst. Die Qualität der Kalibrierung konnte gegenüber der herkömmlichen Methode signifikant verbessert werden. Die Auswirkung der Kalibrierungsparameter auf die Spurrekonstruktion wurde untersucht und für die beiden Kalibrierungsmethoden verglichen. Die Ergebnisse lassen keinen eindeutigen Schluss auf die Auswirkung der Fehler in der Kalibrierung auf die Qualität der Spurrekonstruktion zu, da die Ergebnisse der Spurrekonstruktion von anderen Effekten dominiert werden.
The influence of visual tasks on short and long-term memory for visual features was investigated using a change-detection paradigm. Subjects completed 2 tasks: (a) describing objects in natural images, reporting a specific property of each object when a crosshair appeared above it, and (b) viewing a modified version of each scene, and detecting which of the previously described objects had changed. When tested over short delays (seconds), no task effects were found. Over longer delays (minutes) we found the describing task influenced what types of changes were detected in a variety of explicit and incidental memory experiments. Furthermore, we found surprisingly high performance in the incidental memory experiment, suggesting that simple tasks are sufficient to instill long-lasting visual memories. Keywords: visual working memory, natural scenes, natural tasks, change detection
In this proceeding the emergence of a composite, adjoint-scalar field as an average over (trivial holonomy) calorons and anti-calorons is reviewed. This composite field acts as a background field to the dynamics of perturbative gluons, to which it is coupled via an effective, gauge invariant Lagrangian valid for temperatures above the deconfinement phase transition. Moreover a Higgs mechanism is induced by the composite field: two gluons acquire a quasi-particle thermal mass. On the phenomenological side the composite field acts as a bag pressure which shows a linear dependence on the temperature. As a result the linear rise with temperature of the trace anomaly is obtained and is compared to recent lattice studies.
ALICE (A Large Ion Collider Experiment), is the dedicated heavy-ion experiment at the Large Hadron Collider (LHC) at CERN. It is optimised to reconstruct and identify the particles created in a lead-lead collision with a centre of mass energy of 5.5TeV. The main tracking detector is a large-volume time-projection chamber (TPC). With an active volume of about 88m^3 and a total readout area of 32.5m^2 it is the most challenging TPC ever build. A central electrode divides the 5m long detector into two drift regions. Each readout side is subdivided into 18 inner and 18 outer multi-wire proportional read-out chambers. The readout area is subdivide into 557568 pads, where each pad is read out by and electronics chanin. A complex calibration is needed in order to reach the design position-resolution of the reconstructed particle tracks of about 200um. One part of the calibration lies in understanding the electronic-response. The work at hand presents results of the pedestal and noise behaviour of the front-end electronics (FEE), measurements of the pulse-shaping properties of the FEE using results obtained with a calibration pulser and measurements performed with the laser-calibration system. The data concerned were taken during two phases of the TPC commissioning. First measurements were performed in the clean room where the TPC was built. After the TPC was moved underground and built into the experiment, a second round of commissioning took place. Noise measurements in the clean room revealed a very large fraction of pads with noise values larger than the design specifications. The unexpected high noise values could be explained by the 'ground bounce' effect. Two modifications helped to reduce this effect: A desynchronisation in the the start of the readout of groups of channels and a modification in the grounding scheme of the FEE. Further noise measurements were carried out after the TPC has been moved to the experimental area underground. Here even a larger fraction of channels showed too large noise values. This could be traced back to a common mode current injected by the electronics power supplies. To study the shaping properties of the FEE a calibration pulser was used. To generate signals in the FEE a pulse is injected to the cathode wires of the read-out chambers. Due to manufacturing tolerances slight channel-by-channel variations of the shaping properties are expected. This effects the determination of the arrival time as well as the measured integral signal of the induced charge and has to be corrected. The measured arrival time variations follow a Gaussian distribution with a width (sigma) of 6.2ns. This corresponds to an error of the cluster position of about 170um. The charge variations are on the level of 2.8%. In order to reach the intrinsic resolution on the measurement of the specific energy loss of the particles (6%) those variations have to be taken into account. The photons of the laser-calibration system are energetic enough to emit photo electrons off metallic surfaces. Most interesting for the detector calibration are photo electrons from the central electrode. The laser light is intense enough to get a signal in all readout channels of the TPC. Since the central electrode is a smooth surface, differences in the arrival time between sectors reveal mechanical displacements of the readout sectors and can be used to correct for this effect. In addition the measurements can be used to determine the electron drift velocity in the TPC gas. The drift velocity measurements have shown a vertical as well as a radial gradient. The first can be explained by the temperature gradient, which naturally builds up in the 5m high detector. The second gradient is most probably caused by a relative conical deformation of the readout plane and the central electrode.
We compare away-side hadron correlations with respect to tagged heavy quark jets computed within a weakly coupled pQCD and a strongly coupled AdS/CFT model. While both models feature similar far zone Mach and diffusion wakes, the far zone stress features are shown to be too weak to survive thermal broadening at hadron freeze-out. Observable away-side conical correlations are dominated by the jet-induced transverse flow in near zone “Neck” region, which differs significantly for both models. Unlike in AdS/CFT, the induced transverse flow in the Neck zone is too weak in pQCD to produce conical correlations after Cooper-Frye freeze-out. The observation of conical correlations violating Mach’s law would favor the strongly-coupled AdS/CFT string drag dynamics, while their absence would favor weakly-coupled pQCD-based hydrodynamics.
Malignant neoplasms are one of the top causes of death in all developed countries around the world and account for almost one quarter of all deaths. An individual cell based computational model with strong connections to the experimental data through lattice free, newtonian interaction could be used to validate experimental results and eventually make predictions guiding further experiments. This model was build as a part of the thesis and shall be extended to the modelling of the effects of ionic radition on the vascularised tumour as a possible treatment for inoperable tumours.
A novel experimental approach for studying exotic transitions in few-electron high-Z ions was developed. In this approach, few-electron ions with selectively produced single K-shell holes are used for the investigation of the transition modes that follow the decay of the excited ions. The feasibility of the developed approach was confirmed by an experimental study of the production of low-lying excited states in He-like uranium, produced by K-shell ionization of initially Li-like species. It was found that K-shell ionization is a very selective process that leads to the production of only two excited states, namely the 1s2s 21S0 and 1s2s 23S1. This high level of selectivity stays undisturbed by the rearrangement processes. These experimental findings can be explained using perturbation theory and an independent-particle model, and are a result of the very different impact parameter dependencies of K-shell ionization and L- intrashell excitation. The L-shell electron can be assumed to stay passive in the collision, whereas the K-shell electron is ionized. It was stressed that the current result might directly be applied to accurate studies of the two-photon decay in He-like ions. Up to now, the experimental challenge in conventional 2E1 experiments has been the photon-photon coincidence technique, which is required to separate the true 2E1 events from the x-ray background associated with single photon transitions. In contrast, by exploiting K-shell ionization, the spectral distribution of the two-photon decay could be obtained simply by a measurement of the photon emission, using only a single x-ray detector in coincidence with projectile ionization. One further particular advantage arises from the fact that the 1s2p 3P0 state is not populated, and does not contribute to the continuum distribution of the two-photon emission. At high Z, this state also undergoes a two-photon E1M1 decay, which would be indistinguishable from the 2E1 decay of the 1s2s 1S0. The first measurement of the two-photon energy distribution from the decay of 1s2s 1S0 level in He-like tin was performed by adopting the technique developed in this thesis. In this technique, excited He-like heavy ions were formed by K-shell ionization of initially Li-like species in collisions with a low-Z gas target, and x-ray spectra following the decay of the He-like ions were measured in coincidence with the up-charged tin ions. The observed intense production of the 2E1 transitions, and a very high level of selectivity, make this process particularly suited for the study of the two-photon continuum, and thus for a detailed investigation of the structure of high-Z He-like systems. The method allowed for a background-free measurement of the distribution of the two-photon decay (21S0 -> 11S0) in He-like tin. The measured distribution could also be discriminated from that of other He-like ions, and confirmed, for the first time, the fully relativistic calculations. In addition, the feasibility of the method was confirmed by studying another exotic transition, namely the two-electron one-photon transition (TEOP) in Li-like high-Z ions. An experimental investigation of the radiative decay modes of the 1s2s2 state in Li-like heavy ions has been started. In the first dedicated beam time at the ESR, selective population of this state via K-shell ionization of initially Be-like species was achieved. The x-rays produced in this process were measured by a multitude of x-ray detectors, each placed under different observation angles with respect to the ion beam direction. The spectra associated with projectile electron loss consist (in all cases) of one single x-ray transition, which was attributed to the TEOP decay to the 1s2 2p1/2 level, possibly contaminated by the M1 decay to the 1s22s. Thus it was proven that, by adopting the developed approach, one can indeed produce the desired initial state. This makes this method perfectly suited for studies of TEOP transitions in high-Z systems. An extension of this study, by the inclusion of an electron spectrometer, would also allow for measurements of the autoionization channel, which would provide complete information on the various decay modes of the 1s2s2 state.
In der vorliegenden Arbeit wird ein schnelles Choppersystem für einen hochintensiven niederenergetischen Protonenstrahl untersucht. Das Choppersystem wird in der Niedrigenergiesektion (LEBT) der Frankfurter Neutronenquelle FRANZ eingesetzt. Der Treiberstrahl hat dort eine Energie von 120 keV und eine Intensität von bis zu 200 mA Protonen. Gefordert ist die Erzeugung eines gepulsten Strahls mit einem 50 bis 100 ns langen Pulsplateau und einer Wiederholrate von 250 kHz. Nach der Diskussion verschiedener Chopperkonzepte wird der Einsatz eines Kickersystems vorgeschlagen. Magnetische und elektrische Kicker werden im Hinblick auf Geometrie, Ablenkfelder, Strahldynamik, Emittanzwachstum, Leistungsbedarf sowie Betrieb im Schwingungs- oder im Pulsmodus untersucht. Die Realisierung des Choppersystems wird mit Hilfe von numerischen Simulationen und Vorexperimenten geprüft. Ein eigens dazu entwickelter Particle-in-cell (PIC)-Code wird vorgestellt. Er erlaubt die Simulation von Vielteilchen-Prozessen in zeitabhängigen Kickerfeldern unter Berücksichtigung der Effekte der Sekundärelektronen. Die Vorexperimente für die Ansteuerung des Kickers werden präsentiert. Für den magnetischen Kicker wurde eine niederinduktive Testspule und für den elektrischen Kicker ein Transformator bestehend aus einem nanokristallinen Ringbandkern aufgebaut. Abschließend werden die beiden Systeme miteinander verglichen. Ein magnetischer Kicker ist auch bei hohen Strahlintensitäten weniger anfällig für Strahlverluste und kann ohne die Gefahr von Spannungsdurchschlägen betrieben werden. Bei den geforderten hohen Wiederholraten ist jedoch der Leistungsbedarf nicht annehmbar, so dass im Ausblick die Weiterentwicklung eines elektrischen Kickersystems vorgeschlagen wird.
We study the line shapes of radiative φ-decays with a direct coupling of the φ meson to the f0(980) and a0(980) scalar mesons. The latter couple via derivative interactions to π0π0 and π0η, respectively. Although the kaon-loop mechanism is usually regarded as the dominant mechanism in radiative φ decays, here we test a different possibility: we set the kaon-loop to zero and we fit the theoretical curves to the data by retaining only the direct coupling. Remarkably, satisfactory fits can be achieved, mainly due to the effects of derivative interactions of scalar with pseudoscalar mesons.
The mechanism by which the enzyme pyruvate decarboxylase from yeast is activated allosterically has been elucidated. A total of seven three-dimensional structures of the enzyme, of enzyme variants or of enzyme complexes from two yeast species (three of them reported here for the first time) provide detailed atomic resolution snapshots along the activation coordinate. The prime event is the covalent binding of the substrate pyruvate to the side chain of cysteine 221, thus forming a thiohemiketal. This reaction causes the shift of a neighbouring amino acid, which eventually leads to the rigidification of two otherwise flexible loops, where one of the loops provides two histidine residues necessary to complete the enzymatically competent active site architecture. The structural data are complemented and supported by kinetic investigations and binding studies and provide a consistent picture of the structural changes, which occur upon enzyme activation.
The paper will focus on the early texts of Galileo Galilei (1613~1623) and Daniel Bernoulli (1738) as examples of pure combinatorical analysis and perspectively considerations within the mathematical discipline of probability theory. It is argued that Bernoulli's approach needed to be developed further in order to achieve a successful and satisfactory theory of risk. In modern economy the need for a proper definition of a notion of risk is seen and currently discussed within the frame of ISO standards. But as already mentioned this interest is mainly owed to the governmental demands of the Basel II and Solvency standards and therefore an external demand. On the other hand an intrinsic understanding of the meaning of risk, as could be provided by a conclusive theory, could lead to a better success in modelling various risks and help to achieve better prognosis.
The production of quarkonia, the bound state of an heavy quark with its anti-particle, has for a long time been seen as a key process to understand the properties of nuclear matter in a relativistic heavy-ion collision. This thesis presents studies on the production of quarkonia in heavy-ion collisions at the new Large Hadron collider (LHC). The focus is set on the decay of J/Psi and Upsilon-states into their di-electronic decay channel, measured within the central detectors of the ALICE detector.
This work presents the study on the suitability of single-crystal CVD diamond for particle-detection systems in present and future hadron physics experiments. Different characterization methods of the electrical and the structural properties were applied to gain a deeper understanding of the crystal quality and the charge transport properties of this novel semiconductor material. First measurements regarding the radiation tolerance of diamond were performed with sensors heavily irradiated with protons and neutrons. Finally, detector prototypes were fabricated and successfully tested in various experiments as time detectors for minimum ionizing particles as well as for spectroscopy of heavy ions at the energy ranges available at the SIS and the UNILAC facilities of GSI. ...
We calculate low-energymeson decay processes and pion-pion scattering lengths in a two-flavour linear sigma model with global chiral symmetry, exploring the scenario in which the scalar mesons f0(600) and a0(980) are assumed to be ¯qq states.
We argue that Clustering in heavy ion collisions could be the missing element in resolving the socalled HBT puzzle, and briefly discuss the different physical situations where clustering could be present. We then propose a method by which clustering in heavy ion collisions could be detectedin a model-independent way.
Diese Arbeit beschreibt wie mit physikalischen Methoden die Glukosekonzentration gemessen werden kann. Die Infrarot-Spektroskopie bietet eine Möglichkeit da die Energie der meisten Molekülschwingungen Photonenenergien im infraroten Spektralbereich entspricht. Hier zeigen Glukosemoleküle charakteristische Absorptionsspektren, die mit spektroskopischen Methoden gemessen werden. Um nicht invasiv zu messen, wurde eine photoakustische Messmethode gewählt. Die Grundidee ist, dass die durch Licht angeregten Moleküle ihre Anregungsenergie teilweise in Form von Wärme abgeben. Da die anregende Strahlung intensitätsmoduliert ist, wird auch die Wärmeentwicklung periodisch verlaufen wodurch periodische Volumenänderungen hervorgerufen werden, die eine Druckwelle erzeugen, die sich durch empfindliche Mikrofone oder Schallwandler erfassen lässt. So kann im MIR auf Grund der hohen Spezifizität, der Glukosegehalt mit sehr hoher Genauigkeit bestimmt werden. Die Wellenlänge der Glukoseabsorptionsbanden im MIR Bereich sind im Wesentlichen gekoppelte C=O Streck- und O–H Biegeschwingungen. Im MIR-Bereich zeigen Spektren zwischen 8,3µm bis 11,1µm fünf glukoserelevanten Banden. Der photoakustische Effekt wird durch die Rosencwaig-Gersho Theorie beschrieben. Die Absorption des Lichtes in der Probe bewirkt eine Temperaturerhöhung, die als Wärme an Umgebung abgegeben wird. Da das eingestrahlte Licht gepulst ist, wird auch die Wärme periodisch abgegeben. Durch die Absorption eines Laserpulses in der Haut entsteht ein Temperaturgradient, die abhängig vom Absorptionskoeffizienten und der Glukosekonzentration ist. Der führt zu einer Diffusion von Wärme im Absorptionsvolumen. Die Hautoberfläche und damit eine dünne Luftschicht über der Hautoberfläche werden durch die Diffusionswärme periodisch mit der Modulationsfrequenz der Laser aufgeheizt, was als Druckschwankungen in Messkammer mit Mikrofon detektiert wird. Im Mitteinfrarot geben Quantenkaskadenlaser die beste Lichtquelle, wegen ihre gute Strahlqualität und hohe optische Leistung. Die verwendete photoakustische(PA) Resonanzzelle ist nach dem Prinzip des Helmholtz-Resonators konzipiert. Der Vorteil des Verstärkungsverhaltens einer resonanten PA-Zelle kann unter Umständen durch Verwendung Volumenreduzierten und mit empfindlichen Mikrofonen ausgestatteten nicht-resonanten PA-Zelle erreicht werde. Zum Erfassung der PA Signale wird eine Kombination aus einen Analog-Digital Wandlerkarte verwendet, die eine gemeinsame Zeitbasis mit der synchronen Lasersteuerung und der Datenerfassung liefert und phasenechte Fourieranalyse der photoakustischen Signale ermöglicht. Es wurde ein Modellsystem entwickelt um photoakustischen Glukosemessungen in vitro zu testen. Dieses „Phantommodell“ besteht aus einer dünnen Polymermembran befestigt in eine Gefäß von nur paar ml Volumen die mit verschiedenen Glukosekonzentrationen gefüllt wurde. Die modulierte Laserstrahlung passiert die Messzelle und dringt durch die Folie in die wässerige Glukoselösung ein. Das Folienmaterial und Dicke wurde so gewählt, dass keineAbsorption im verwendeten MIR-Bereich entsteht. Als Lösung für die jeweiligen Glukosekonzentrationen wurde ein Wasser-Albumin Gemisch verwendet mit einen 10%igen Albuminanteil, die verwendet wurde, um den Proteingehalt der Haut zu imitieren und zu zeigen, dass Eiweiß keinen Störeinfluss im Glukosefingerprintbereich hat. Messungen wurden bei steigenden und fallenden Glukosekonzentration durchgeführt damit gezeigt könnte, dass das Messsignal in der PA- Zelle nicht von der Lufterwärmung in der Zelle stammt, sondern vom PA-Signale der Glukose. Die Glukoseschwankungen in der extrazellulären Flüssigkeit der Epidermis spiegeln die Glukoseschwankungen im Blut gut wider, bei einer Messung am Arm entsteht eine Verzögerung von paar Minuten. Im Daumenballenbereich findet aufgrund der guten Durchblutung ein schneller Austausch der Glukosekonzentration der von uns gemessenen interstitiellen Flüssigkeit mit der Blutzuckerkonzentration statt. Deshalb wurden die in-vivo Messungen am Daumenballen durchgeführt. Das Stratum spinosum ist für uns von Bedeutung, da dies das interstitielle Wasser enthält, in dem der Glukosegehalt mit dem Glukosegehalt im Blut gut übereinstimmt. Die photoakustische Messmethode wird nicht-invasiv durchgeführt. Probanden wird Zucker verabreichet und danach in Abständen von 5 Minuten der Blutzucker konventionell bestimmt und gleichzeitig mittels der photoakustischen Messung am Daumenballen durchgeführt. Mit diesen Daten kann die Korrelation zwischen beiden Methoden bestimmt werden. In vielen in vivo Messreihen zeigen sich bereits in direkter Korrelation zu invasiv genommenen Blutzuckerwerten Korrelationskoeffizienten bis zu R=0,8 und eine damit deutliche Evidenz für einen glukoserelevanten Effekt. Trotz der versprechenden Ergebnisse wird deutlich, dass weitere Entwicklungen notwendig sind, damit das System zu einer direkten Konkurrenz zu der vorhandenen invasiven Meßsystemen werden kann.
The current performance of a 4π barium fluoride gamma detector consisting of 41 modules is evaluated. It will be used to measure neutron capture events in different samples that are exposed to a neutron beam that is expected to contain up to 10^7 neutrons/(cm^2 sec). The capture cross-sections acquired in this experiment will be relevant to a multitude of different areas, for example to s-process studies, or accelerator-driven systems. The detector array was re-mounted after having been moved from Karlsruhe to Frankfurt and in the course of this process, the detector modules have been checked for their current detection properties. Every module consists of a BaF2 crystal, a photomultiplier tube connected to the crystal by sillicon oil and a voltage divider to drive the PMT, so each of them is already an individual gamma detector. Using Cobalt-60 and Caesium-137 test sources the energy resolution and - more importantly - the time resolution of every module has been determined; the results are presented in this work and compared to previous data taken at the time the detector was built initially in the mid-1980s.
Gegenstand dieser Arbeit ist die Entwicklung, der Aufbau und die Charakterisierung sowie Messung einer anwendungsspezifischen integrierten Schaltung (engl.: Application Specific Integrated Circuit, ASIC). Sie dient der Auslese der im elektromagnetischen Kalorimeter des PANDA-Experiments eingesetzten Lawinenfotodioden. Jeder Auslesekanal beinhaltet in der Eingangsstufe einen ladungsempfindlichen Vorverstärker, gefolgt von einem Pulsformer sowie zwei Ausgangstreibern. Am Beginn der Entwicklung steht die Machbarkeitsstudie einer integrierten Ausleseelektronik, welche die anspruchsvollen Anforderungen des PANDA-Experiments erfüllt. Aus rauschtheoretischen Untersuchungen resultieren erste Entwurfsparameter für die Schaltung, die mit Hilfe umfangreicher Simulationen verbessert und ergänzt werden. Die technische Umsetzung der Schaltung erfolgt in einem 0,35 Micrometer-CMOS-Prozess der Firma Austria Mikrosysteme. Die Charakterisierung der integrierten Ausleseelektronik ergibt bei einer Umgebungstemperatur von T = - 20° C eine Shapingzeit des Signalpulses von tr = (124 ± 2) ns. Mit dem äquivalenten Rauschwert von ENC = (4456 ± 35) e- und einer maximal möglichen Eingangsladung von 7,84 pC folgt ein dynamischer Bereich von über 10 000. Der ratenunabhängige Leistungsbedarf eines einzelnen Auslesekanals beträgt P = (52, 4 ± 0, 2)mW. Damit erfüllt der in dieser Arbeit beschriebene ASIC Prototyp alle Anforderungen, die vom Experiment an die Ausleseelektronik gestellt werden.
Motiviert durch aktuelle atomphysikalische Fragestellungen zur Struktur und Dynamik der Materie im Bereich hochgeladener Schwerionen entstand der Bedarf zur Weiterentwicklung bestehender und zur Entwicklung neuartiger ortsauflösender Detektorsysteme. Die Untersuchung der Struktur ist hauptsächlich durch die hochauflösende spektroskopische Vermessung einzelner Energieniveaus der atomaren Hülle bestimmt und liefert grundlegende Einblicke in den atomaren Aufbau. Dabei stellen diese Resultate gerade bei schweren hochgeladenen Ionen eine exzellente Testmöglichkeit der QED in extrem starken Feldern dar. Die Dynamik der Materie zeigt sich in der Teilchendynamik (hier der Atomhülle) in extrem starken und extrem kurzen elektromagnetischen Feldern, wie sie bei Ion-Atom-Stößen auftreten. Beobachtet werden können hier vor allem Teilchen und Photonen-Polarisationsphänomene. Solche Polarisationseffekte sind jedoch nicht auf das Gebiet der atomaren Hülle beschränkt. Als ein Beispiel sei die Untersuchung laserbeschleunigter Teilchen genannt. Hier kann die Polarimetrie von Röntgenstrahlung, die durch Thomson-Streuung optischer Photonen an den zuvor auf relativistische Geschwindigkeiten beschleunigten Teilchen erzeugt wird, Aufschluß über die Natur des Beschleunigungsprozesses geben. Einblick in die lineare Polarisation der Röntgenphotonen im für unsere Arbeit interessanten Energiebereich von einigen 10 keV bis einigen 100 keV können mit Compton-Polarimetern gewonnen werden. Kommerziell sind Detektorsysteme, die eine ausreichende Granularität in Kombination mit hinreichender Detektordicke besitzen, um hohe Nachweiseffizienzen zu erreichen, jedoch nicht verfügbar. Im Rahmen der vorgelegten Arbeit, die sich mit Techniken der hochaufgelösten Röntgenspektroskopie und der Röntgenpolarimetrie an hochgeladenen Schwerionen befasst, wurden vielfältige Arbeiten an und mit orts-, zeit- und energieauflösenden planaren Ge(i)-Detektorsystemen durchgeführt. Wesentliches Ziel der Arbeit war es, ein zweidimensional ortsauflösendes planares Halbleiterdetektorsystem, das für den Einsatz im Kristallspektrometer FOCAL und als Compton-Polarimeter angepasst ist, bereitzustellen. Hierzu wurde ein 2D-µ-Streifendetektorsystem aufgebaut, das eine Ortsauflösung von 250µm, bzw. 1167µm in orthogonaler Richtung, bei einer Detektordicke von 11mm und eine Energieauflösung von etwa 2 keV für jeden einzelnen Streifen bei 60 keV Photonenenergie gewährleistet. Durch Messungen an der Synchrotronquelle ESRF, Grenoble (Frankreich), wurde die Eignung des Systems als bildgebendes Element im FOCAL Kristallspektrometer bei einer Photonenenergie von 60 keV und als Compton-Polarimeter bei einer Photonenenergie von 210 keV untersucht. Der große Vorteil in FOCAL ein ortsauflösendes Detektorsystem einzusetzen, liegt darin, dass alle interessanten Beugungswinkel simultan beobachtet werden können. Im herkömmlichen Ansatz würde man mit einer einfachen Diode und einem Kollimator den Bereich abfahren. Wegen der geringen Ereignisrate und dem hohen Untergrund ist dies jedoch nicht praktikabel. Herkömmliche Systeme wie CCD oder Gasdetektoren haben nicht die nötige Effizienz oder eine zu hohe Dunkelrate. Zur Untersuchung der für FOCAL wichtigen Eigenschaften wurden mehrere Positionen auf dem Detektor bei niedriger Energie mit einem fein kollimierten Photonenstrahl (50 x 50 µm2) gescannt. Neben der guten Energieauflösung des Detektorsystems von durchschnittlich 2.2 keV bei 60 keV, zeigen die Ergebnisse das homogene Verhalten der Detektoreffizienz, welche essentiell für den spektographischen Einsatz in FOCAL ist. Es konnten keine Hinweise auf messbare Ladungsverluste im Bereich des aktiven Detektorvolumens festgestellt werden. Ebenso konnte die Multiplizität (Anzahl der Streifen einer Detektorseite, die auf ein Ereignis reagieren), mit der ein Photon nachgewiesen wird, eindeutig mit der Strukturierung der Kontakte auf der Kristalloberfläche in Verbindung gebracht werden. Es stellte sich heraus, dass die Ereignisse der Multiplizität zwei dazu verwendet werden können um Ortsauflösungen deutlich unterhalb einer Streifenbreite zu erreichen. Diese Methode kann jedoch nur auf eine größere Anzahl von Ereignissen angewendet werden, nicht jedoch auf einzelne Ereignisse. Um das 2D-Ge(i)-µ-Streifendetektorsystem auf seine Eignung als Compton-Polarimeter zu testen, wurden Daten mit einem nahezu vollständig linear polarisierten Photonenstrahl (98% linear polarisiert) bei einer Energie von 210 keV aufgenommen. Die Daten zeigen die erwartete Dipol-ähnliche Asymmetrie im Ortsbild und dienen als Kalibrationsgrundlage zur Interpretation zukünftiger Experimente zur Polarimetrie in diesem Energiebereich. Parallel hierzu wurde an Simulationsprogrammen auf Basis der etablierten Monte Carlo Software EGS4 gearbeitet. Hiermit wurden Vorhersagen bezüglich des Nachweisverhaltens des Detektors auf linear polarisierte Röntgenstahlung gemacht. Ferner wurde für ein 4x4-Pixel-Polarimeter, das bei der ersten Bestimmung der linearen Polarisation der K-REC Strahlung von U92+ am Speichering ESR der GSI eingesetzt wurde, im Rahmen der Datenanalyse mit den auf EGS4-basierenden Programmen die Detektoreffizienz für linear polarisierte Strahlung einer bestimmten Energie simuliert. Mit diesen Simulationsergebnissen konnten die selbstentwickelten Methoden zur Korrektur der Nachweiswahrscheinlichkeit eines Compton-Ereignisses als Funktion des Wechselwirkungspunkts innerhalb des Detektorkristalls und der Energie erfolgreich verifiziert werden. Die detektorbezogenen Resultate dieser Arbeit fanden ihre erste Anwendung in der FOCAL-Spektrometer Strahlzeit 2006, deren genaue Beschreibung jedoch über den Umfang dieser Arbeit hinausgeht. Ebenso flossen die Erfahrungen, die mit den Detektorsystemen, im speziellen dem 2D-Ge(i)-µ-Streifendetektor, gemacht wurden in die Realisierung eines Si(Li)-Detektors mit 32+32 Streifen zur Compton-Polarimetrie bei niedrigeren Energien (ab 60 keV) ein, der gegenwärtig in ersten Experimenten am ESR eingesetzt wird.
Im Rahmen dieser Arbeit sind Experimente zur Bestimmung der 1s Lamb-Verschiebung in wasserstoffartigen Schwerionen und zur Bestimmung des Innerschalenübergangs 2 3P2 --> 2 3S1 in heliumartigen Schwerionen durchgeführt worden. Diese Untersuchungen sind interessant, da es sich hierbei um die Überprüfung der Quantenelektrodynamik im Bereich sehr starker Coulombfelder handelt. Neben den reinen QED-Effekten spielen in diesen schweren Systemen auch relativistische Effekte eine immer bedeutendere Rolle. Es ist erstmals gelungen, eine direkte Messung des Innerschalenübergangs 2 3P2 --> 2 3S1 in einem schweren Z-System durchzuführen. Während in bisherigen Experimenten lediglich leichtere Ionen bis zu einer Kernladungszahl Z = 54 untersucht wurden, sind wir mit unserem Experiment an U90+-Ionen in den Bereich schwerer Systeme vorgedrungen. Zur Energiebestimmung sind am Gastarget des Experimentier-speicherrings (ESR) ein Kristallspektrometer unter einem Beobachtungswinkel von 90° und ein einfacher planarer Germaniumdetektor unter einem Winkel von 35° aufgebaut worden. Das Kristallspektrometer ermöglicht eine hohe Energieauflösung, während der Germaniumdetektor einen breiten Energiebereich abdeckt und somit eine eindeutige Identifizierung der Übergänge ermöglicht. Ein Fit des aufgenommenen Energiespektrums mit einer Simulation zeigt, wie gut die theoretischen Vorhersagen die Übergangsdynamik in diesem Zwei-Elektronen-System beschreiben. Der Innerschalenübergang kann eindeutig von benachbarten Übergängen unterschieden werden. Mit dem Kristallspektro-meter ergibt sich eine Übergangsenergie von 4510,31 ± 0,51 eV, mit dem Germanium-detektor 4509,6 ± 1,5 eV. Beide stimmen gut mit den theoretischen Vorhersagen überein. Durch den geringen Fehler von 0,51 eV stellt diese Messung auch im Vergleich mit den vorhergehenden Experimenten in leichten Systemen eine der genauesten Messungen des Innerschalenübergangs in He-artigen Ionen dar. Zusätzlich dazu kann die Differenz der Innerschalenübergangsenergie von Li-artigem und He-artigem Uran ermittelt werden: 50,94 ± 0,45 eV. Mit dieser Genauigkeit ist unser Experiment empfindlich auf die Zwei-Elektronen-QED und ermöglicht erstmal eine experimentelle Überprüfung dieses Beitrags, der von Kozhedub et al. mit 1,18 eV angegeben wird. Zur Untersuchung der 1s Lamb-Verschiebung von wasserstoffartigen Schwerionen sind bereits eine Vielzahl an Experimenten durchgeführt worden, mit einer maximalen Genauigkeit von 4,6 eV. Die theoretische Auswertung von Korrekturtermen höherer Ordnung erfordert jedoch neue experimentelle Methoden, mit denen sich Genauigkeiten auf dem Niveau von 1 eV und besser erzielen lassen. Dazu hat es ein Nachfolge-experiment zur bisher genauesten Messung der 1s Lamb-Verschiebung in U91+ und des Zwei-Elektronen-Beitrags zum Grundzustand in U90+ am Elektronenkühler gegeben. Hierzu ist das Experiment bei einer niedrigeren Strahlenergie durchgeführt worden. Dabei hat sich allerdings gezeigt, Ionenstrahlen mit einer Energie unterhalb von 20MeV/u besitzen zu kurze Lebensdauern, da bei den niedrigeren Energien die Rekombinationsverluste mit dem Restgas sehr hoch werden und der Ionenstrahl aus technischen Gründen noch einmal umgebuncht werden muss, wobei zusätzlich Zeit und Intensität verloren gehen. Als weiterer Schritt auf dem Weg zu höherer Präzision ist eine Kombination aus einem hochauflösenden Kristallspektrometer (FOCAL) und einem neuartigen orts- und energieauflösenden 2dimensionalen Germaniumdetektor getestet worden. Mit diesem Detektor ist es möglich, mehrere Reflexe gleichzeitig zu messen und somit die Effizienz des Experimentes deutlich zu steigern. Allerdings ist die maximale Energieauflösung bisher über die 250 µm Streifenbreite des Detektors definiert, das entspricht etwas weniger als 200 eV. Tests mit Kalibrationsquellen und das Verfahren des Detektors entlang der Dispersionsachse haben jedoch gezeigt, dass eine Auflösung kleiner als ein Streifen erreichbar ist. Dadurch soll eine Genauigkeit von 1 eV erreicht werden. Die Bewegung der Detektoren, die bei der letzten Strahlzeit einen erheblichen systematischen Fehler verursacht hat, kann mit neuen Detektorplattformen und kontinuierlicher Stickstofffüllung deutlich reduziert werden. Bei den alternativen Methoden Mikrokalorimeter und Absorptionskantenspektroskopie scheinen Mikrokalorimeter eine vielversprechend Entwicklung zu sein, da sie sowohl eine hohe Energieauflösung bieten als auch einen breiten Energiebereich abdecken. Dagegen beinhaltet die Absorptionskantenspektroskopie im Vergleich zu den anderen Methoden zu große systematische Fehler. Aus den Ergebnissen des Experimentes zum Innerschalenübergang und des FOCAL-Commissioning-Experimentes zeigt sich, wie erfolgsversprechend der Einsatz von Kristallspektrometern auf dem Weg zu neuen hochpräzisen Experimenten ist.
Schon seit längerer Zeit wird die Verwendung sogenannter Gabor-Plasmalinsen, in denen ein einkomponentiges also Nichtneutrales Plasma eingeschlossen wird, zur Fokussierung von Teilchenstrahlen untersucht. Um eine gute Fokussierqualität zu erreichen, wird ein hoher Füllgrad der Linse, sowie ein lineares elektrisches Feld benötigt. Während die Gabor-Plasmalinse innerhalb ihres Arbeitsbereiches, in dem das Plasma als thermalisiert angenommen wird, gute Abbildungseigenschaften aufweist, kommt es außerhalb der Arbeitsfunktion der Raumladungslinse zu einem starken Verlust der Strahlqualität. Die Gabor-Plasmalinse dient als Instrument, doch um ihre Anwendung zu optimieren, müssen die wesentlichen Prozesse in Nichtneutralen Plasmen verstanden werden. In der vorliegenden Arbeit wurden Diagnosemethoden zur Bestimmung der Plasmaparameter eines Nichtneutralen Plasmas untersucht, deren Anwendung sich im Bereich der elektrisch neutralen Plasmen bewährt haben. Es wurden desweiteren neue Methoden entwickelt, um die wichtigen Parameter wie Elektronendichte und Elektronentemperatur bestimmen zu können. Die Ergebnisse der Messungen werden numerischen Simulationen vergleichend gegenübergestellt.