Refine
Year of publication
Has Fulltext
- yes (1085)
Is part of the Bibliography
- no (1085)
Keywords
- Heavy Ion Experiments (20)
- Hadron-Hadron Scattering (11)
- Hadron-Hadron scattering (experiments) (11)
- LHC (9)
- Heavy-ion collision (6)
- ALICE experiment (4)
- Collective Flow (4)
- Jets (4)
- Quark-Gluon Plasma (4)
- ALICE (3)
- Heavy Ions (3)
- Jets and Jet Substructure (3)
- pp collisions (3)
- Beauty production (2)
- Charm physics (2)
- Diagnostik (2)
- Electroweak interaction (2)
- Experimental nuclear physics (2)
- Experimental particle physics (2)
- Früherkennung (2)
- Heavy Quark Production (2)
- Lepton-Nucleon Scattering (experiments) (2)
- Mammakarzinom (2)
- Nachsorge (2)
- Particle Correlations and Fluctuations (2)
- Particle and resonance production (2)
- Particle correlations and fluctuations (2)
- Pb–Pb collisions (2)
- QCD (2)
- Richtlinie (2)
- Single electrons (2)
- breast cancer (2)
- diagnosis (2)
- follow‑up (2)
- guideline (2)
- screening (2)
- 900 GeV (1)
- ALICE detector (1)
- Anti-kaon–nucleon physics (1)
- Anti-nuclei (1)
- Boosted Jets (1)
- Branching fraction (1)
- Centrality Class (1)
- Centrality Selection (1)
- Climate-change ecology (1)
- Collective Flow, (1)
- Community ecology (1)
- Comparison with QCD (1)
- Ecological modelling (1)
- Ecological networks (1)
- Electron-pion identification (1)
- Elliptic flow (1)
- Femtoscopy (1)
- Fibre/foam sandwich radiator (1)
- Gender reassigning surgery (1)
- HBT (1)
- Hadron production (1)
- Hadron-Hadron Scattering Heavy (1)
- Hadron-hadron interactions (1)
- Hadronization (1)
- Hard Scattering (1)
- Heavy Ion Experiment (1)
- Heavy flavor production (1)
- Heavy flavour production (1)
- Heavy ion collisions (1)
- Heavy ions (1)
- Heavy-flavour decay muons (1)
- Heavy-flavour production (1)
- Heavy-ion collisions (1)
- Inclusive spectra (1)
- Intensity interferometry (1)
- Invariant Mass Distribution (1)
- Ionisation energy loss (1)
- Jet Physics (1)
- Jet Substructure (1)
- Kaonic nuclei (1)
- Lemperle (1)
- Leptonic, semileptonic & radiative decays (1)
- Low energy QCD (1)
- Mastectomy (1)
- Material budget (1)
- Mid-rapidity (1)
- Minimum Bias (1)
- Monte Carlo (1)
- Multi-Parton Interactions (1)
- Multi-strange baryons (1)
- Multi-wire proportional drift chamber (1)
- Net-charge correlations (1)
- Net-charge fluctuations (1)
- Neural network (1)
- Nuclear modification factor (1)
- PYTHIA (1)
- Partial wave analysis (1)
- Particle and Resonance Production (1)
- Particle decays (1)
- Particle phenomena (1)
- Pb–Pb (1)
- Production Cross Section (1)
- Properties of Hadrons (1)
- Proton–proton (1)
- Quark Deconfinement (1)
- Quark Gluon Plasma (1)
- Quark Production (1)
- Quark gluon plasma (1)
- Quarkonium (1)
- Rapidity Range (1)
- Relativistic heavy ion physics (1)
- Relativistic heavy-ion collisions (1)
- Resolution Parameter (1)
- Single muons (1)
- Systematic Uncertainty (1)
- TR (1)
- Time Projection Chamber (1)
- Tracking (1)
- Transgender (1)
- Transition radiation detector (1)
- Transverse momentum (1)
- Trigger (1)
- Vector Boson Production (1)
- Xenon-based gas mixture (1)
- antihelix shaping (1)
- dE/dx (1)
- detector (1)
- experimental results (1)
- heavy ion experiments (1)
- otoplasty (1)
- ppK − (1)
- protruding ear (1)
- quark gluon plasma (1)
- spectra (1)
- ventral otoplasty (1)
- √sN N = 2.76 TeV (1)
Institute
We report results on the ratio of midrapidity antiproton-to-proton yields in Au+Au collisions at sqrt[sNN] = 130 GeV per nucleon pair as measured by the STAR experiment at RHIC. Within the rapidity and transverse momentum range of | y|<0.5 and 0.4<pt<1.0 GeV/c, the ratio is essentially independent of either transverse momentum or rapidity, with an average of 0.65±0.01(stat)±0.07(syst) for minimum bias collisions. Within errors, no strong centrality dependence is observed. The results indicate that at this RHIC energy, although the p-p-bar pair production becomes important at midrapidity, a significant excess of baryons over antibaryons is still present.
Elliptic flow from nuclear collisions is a hadronic observable sensitive to the early stages of system evolution. We report first results on elliptic flow of charged particles at midrapidity in Au+Au collisions at sqrt(s_NN)=130 GeV using the STAR TPC at RHIC. The elliptic flow signal, v_2, averaged over transverse momentum, reaches values of about 6% for relatively peripheral collisions and decreases for the more central collisions. This can be interpreted as the observation of a higher degree of thermalization than at lower collision energies. Pseudorapidity and transverse momentum dependence of elliptic flow are also presented.
Mastectomy in female-to-male transgender patients: A single-center 24-year retrospective analysis
(2019)
Background: Mastectomy in male transgender patients is an important (and often the first) step toward physical manhood. At our department, mastectomies in transgender patients have been performed for several decades.
Methods: Recorded data were collected and analyzed for all male transgender patients undergoing mastectomy over a period of 24 years at our department.
Results: In total, 268 gender-reassigning mastectomies were performed. Several different mastectomy techniques (areolar incision, n=172; sub-mammary incision, n=96) were used according to patients’ habitus and breast features. Corresponding to algorithms presented in the current literature, certain breast qualities were matched with a particular mastectomy technique. Overall, small breasts with marginal ptosis and good skin elasticity allowed small areolar incisions as a method of access for glandular removal. In contrast, large breasts and those with heavy ptosis or poor skin elasticity often required larger incisions for breast amputation. The secondary correction rate (38%) was high for gender reassignment mastectomy, as is also reflected by data in the current literature. Secondary correction frequently involved revision of chest wall recontouring, suggesting inadequate removal of the mammary tissue, as well as scar revision, which may reflect intense traction during wound healing (36%). Secondary corrections were performed more often after using small areolar incision techniques (48%) than after using large sub-mammary incisions (21%).
Conclusions: Choosing the suitable mastectomy technique for each patient requires careful individual evaluation of breast features such as size, degree of ptosis, and skin elasticity in order to maximize patient satisfaction and minimize secondary revisions.
Ecological networks are more sensitive to plant than to animal extinction under climate change
(2016)
Impacts of climate change on individual species are increasingly well documented, but we lack understanding of how these effects propagate through ecological communities. Here we combine species distribution models with ecological network analyses to test potential impacts of climate change on >700 plant and animal species in pollination and seed-dispersal networks from central Europe. We discover that animal species that interact with a low diversity of plant species have narrow climatic niches and are most vulnerable to climate change. In contrast, biotic specialization of plants is not related to climatic niche breadth and vulnerability. A simulation model incorporating different scenarios of species coextinction and capacities for partner switches shows that projected plant extinctions under climate change are more likely to trigger animal coextinctions than vice versa. This result demonstrates that impacts of climate change on biodiversity can be amplified via extinction cascades from plants to animals in ecological networks.
Ziele: Das Ziel dieser offiziellen Leitlinie, die von der Deutschen Gesellschaft für Gynäkologie und Geburtshilfe (DGGG) und der Deutschen Krebsgesellschaft (DKG) publiziert und koordiniert wurde, ist es, die Früherkennung, Diagnostik, Therapie und Nachsorge des Mammakarzinoms zu optimieren.
Methoden: Der Aktualisierungsprozess der S3-Leitlinie aus 2012 basierte zum einen auf der Adaptation identifizierter Quellleitlinien und zum anderen auf Evidenzübersichten, die nach Entwicklung von PICO-(Patients/Interventions/Control/Outcome-)Fragen, systematischer Recherche in Literaturdatenbanken sowie Selektion und Bewertung der gefundenen Literatur angefertigt wurden. In den interdisziplinären Arbeitsgruppen wurden auf dieser Grundlage Vorschläge für Empfehlungen und Statements erarbeitet, die im Rahmen von strukturierten Konsensusverfahren modifiziert und graduiert wurden.
Empfehlungen: Der Teil 1 dieser Kurzversion der Leitlinie zeigt Empfehlungen zur Früherkennung, Diagnostik und Nachsorge des Mammakarzinoms: Der Stellenwert des Mammografie-Screenings wird in der aktualisierten Leitlinienversion bestätigt und bildet damit die Grundlage der Früherkennung. Neben den konventionellen Methoden der Karzinomdiagnostik wird die Computertomografie (CT) zum Staging bei höherem Rückfallrisiko empfohlen. Die Nachsorgekonzepte beinhalten Untersuchungsintervalle für die körperliche Untersuchung, Ultraschall und Mammografie, während weiterführende Gerätediagnostik und Tumormarkerbestimmungen bei der metastasierten Erkrankung Anwendung finden.
Purpose: The aim of this official guideline coordinated and published by the German Society for Gynecology and Obstetrics (DGGG) and the German Cancer Society (DKG) was to optimize the screening, diagnosis, therapy and follow-up care of breast cancer.
Methods: The process of updating the S3 guideline dating from 2012 was based on the adaptation of identified source guidelines which were combined with reviews of evidence compiled using PICO (Patients/Interventions/Control/Outcome) questions and the results of a systematic search of literature databases and the selection and evaluation of the identified literature. The interdisciplinary working groups took the identified materials as their starting point to develop recommendations and statements which were modified and graded in a structured consensus procedure.
Recommendations: Part 1 of this short version of the guideline presents recommendations for the screening, diagnosis and follow-up care of breast cancer. The importance of mammography for screening is confirmed in this updated version of the guideline and forms the basis for all screening. In addition to the conventional methods used to diagnose breast cancer, computed tomography (CT) is recommended for staging in women with a higher risk of recurrence. The follow-up concept includes suggested intervals between physical, ultrasound and mammography examinations, additional high-tech diagnostic procedures, and the determination of tumor markers for the evaluation of metastatic disease.